Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC KALLUVALAPPIL HOUSE PERUMUGHAM PO FEROKE 673 631 KOZHIKKODE | FEROKE | KOZHIKODE | KERALA | 673631 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.4 L+₹1.1 L (7.22%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.6 L+₹1.3 L (8.55%)Rejected-Finance TV BUILDING TP 5 81 B OPPOSITE BUS STOP NADUVATH MALAPPURAM | NADUVATH | MALAPPURAM | KERALA | L3 | Rejected-Finance L3 |
Tender Value
₹15.3 L
EMD Value
₹22,902
Closing Date
22 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Senior Manager (SBUB)
STEEL INDUSTRIALS KERALA LTD. Ship Breaking Unit Beypore p.o KOZHIKODE- 673015
Truss Work at Zoology Block in Government Arts and Science College, Kozhikode-18.
2021_SILK_414522_1
SILK/SBU(B)/2020-21/248
Open Tender
Miscellaneous Works
Item Rate
30 days
Kozhikode
As per tender documents
6 documents required · 6 mandatory
₹2,950
₹22,902
Yes
14 Feb 2022
12 Feb 2021
23 Feb 2021
12 Feb 2021
22 Feb 2021
12 Feb 2021
12 Feb 2021 - 22 Feb 2021
90 days
Amount
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.21 Providing and fixing M.S. rivets of sizes in position.
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.4.2 Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2
12.51.2 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Flashings / Aprons (Upto 600 mm)
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
od268942/2020_2021 Providing and fixing 160mm wide, plain PVC half sheet gutter with iron brackets 30x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.<br>4kgf/cm2
12.42.5.2 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5<sup>0</sup>110 mm bend
12.42.1.2 null Coupler110 mm
FORTUNE SOLUTIONS
FLORA AGENCIES
stage.html
html • 0.05 MB
technical_588750.pdf
PDF • 0.71 MB
techsummary_588750.pdf
PDF • 0.70 MB
finance_588750.pdf
PDF • 0.44 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_588750.pdf
PDF • 0.52 MB
414522WO.PDF
PDF • 0.99 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .