Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAdmitted-Finance | ₹9.9 L | L1 | Admitted-Finance |
| 2 | L2₹9.9 LAdmitted-Finance | ₹9.9 L | L2 | Admitted-Finance |
| 3 | L3₹10.0 LAdmitted-Finance | ₹10.0 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ms Varsha Construction L3 | Gupta Traders and Engineering Works L1 | M/S GURU KRIPA TRADERS L2 |
|---|---|---|---|---|---|---|
| 1.00fo|qr forj.k [k.M&lfB;kWo] vktex<+ ds vUrxZr 10 vn~n 33@11 ds0oh0 fo|qr midsUnzksa esa yxs 33 ,oa 11 ds0oh0 la;[email protected] ds fizosfUVo esuVsaul dk dk;Z foRrh; o"kZ 2025&26 ¼06 ekg eas 01 ckj½ | ||||||
| 1.01 | budfeax iSusy
Work involved-
1-Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value.
2-Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment contact resistance measurement of Vaccum Interrupter.
3-Checking and testing of closing/tripping machanism of breaker.
4-Replacement of weaker insulation control cables/Wiring.
5-Cleaning of Jaws and its greasing/oiling.
6-Cleaning of Busbar spout and replacement of spout with lesser IR Value.
7-Cleaning of PT,CT an CT spout.
8-Cleaning of Relays through suitable solvent.
9-Adjustment of setting of Relays as required and consequent testing.
10-Tighening of power and control cable connections.
11-Heating of panel through blower. | 16 | tkWc | 11,750 ₹1.9 L | 10,885 ₹1.7 L | 10,934 ₹1.7 L |
| 1.02 | vkmVxksbax iSusy
Work involved-
1-Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value.
2-Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment contact resistance measurement of Vaccum Interrupter.
3-Checking and testing of closing/tripping machanism of breaker.
4-Replacement of weaker insulation control cables/Wiring.
5-Cleaning of Jaws and its greasing/oiling.
6-Cleaning of Busbar spout and replacement of spout with lesser IR Value.
7-Cleaning of CT an CT spout.
8-Cleaning of Relays through suitable solvent.
9-Adjustment of setting of Relays as required and consequent testing.
10-Tighening of power and control cable connections.
11-Heating of panel through blower. | 38 | tkWc | 10,200 ₹3.9 L | 10,390 ₹3.9 L | 10,437 ₹4.0 L |
| 1.03 | 33 ds0oh0 fLop;kMZ dk dk;Z
WWork involved-
1-Meggering of lightening arresters fo all 3 phases of all power transformers of the substations.
2-Mechanical adjustment of bus side and line side TPMO/Isolator,oiling and greasing of moving parts of ensure smooth operation..
3-Mechanical adjustment as required of 33 kv breaker, Oiling and greasing of moving parts to ensure smooth operation.
4-Ensure local and remote operation of 33 KV breaker.
5-Cleaning of all switchgears. | 16 | tkWc | 10,200 ₹1.6 L | 10,885 ₹1.7 L | 10,934 ₹1.7 L |
| 2.00fo|qr forj.k [k.M&lfB;kWo] vktex<+ ds vUrxZr 10 vn~n 33@11 ds0oh0 fo|qr midsUnzksa ds czsdMkmu dks ,VSUM dj fo|qr vkiwfrZ jh&LVksj djus dk dk;Z& | ||||||
| 2.01 | 11 ds0oh0 fLopxh;j dk czsdMkmu esUVhuasl ¼budfeax ,oa vkmVxksbax½
1-Attending flashing caused by any fault or other wise (This includes cleaning through suitable solvent, replacement of damaged CT and spout if required.
2-Work on Jaw contact (This includes mechaical adjustment, cleaning and/or replacement of jaws, as required.
3-Work on Vaccum Interrupter Bottle (This includes mechanical adjustment, cleaning and or replacement of bottles, as required.
4-Work on tripping closing coil (This includes mechanical adjustment, cleaning and or replacement of coil as required.
5-Work on tripping clutch (This includes mechanical adjustment, cleaning and/or replacement of clutch as required.
6-Replacement of tripping and closing shaft, as required.
7-Removal of flashing in Busbar spout and its replacement, as required.
8-Removal of flashing in CT spout and its replacement, as required.
9-Work on rackout gear and/or jack bush. (This includes greasing, Replacement, as required.
10-Replacement of damaged indoor/outdoor cable box of 11 kv cable.
11-Replacement of damaged staright through of 11 kv cable.
Note- Any one Job as per the amount of work description given in the above job will be considrened as 1 job.
All t & p and petty Material/ Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt washer, seals etc shall be arreanged by the firm. | 18 | tkWc | 8,650 ₹1.6 L | 7,916 ₹1.4 L | 7,952 ₹1.4 L |
| 2.02 | 33 ds0oh0 fLopxh;j dk czsdMkmu esUVhusal-
1-Attending breakdown caused by any fault or other wise (This includes.
A-Cleaning/Repair/Replacement of CT,PT LA.
B-Repairing/Replacement of damages line side and/or bus side TPMO.
2-Repairing/Replacement of damaged indoor/outdoor cable box of 33 kv level.
3-Replacement of damaged staright through of 33 kv level.
Note- Any one Job as per the amount of work description given in the above job will be considrened as 1 job.
All t & p and petty Material/ Consumables viz oil, grease, cloth, cleaning solvent, nut , bolt washer, seals etc shall be arreanged by the firm. | 12 | tkWc | 8,650 ₹1.0 L | 8,700 ₹1.0 L | 8,700 ₹1.0 L |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
31 Dec 2025, 12:00 pmClosed
GAURAV TIWARI
RAHUL NAGAR MADYA AZAMGARH
Preventive Maintenance and Breakdown attend Work Under EDD-Sathiyaon
2025_PVVNV_1101237_1
47/EDC-II(A)/2025-26
Open Tender
Electrical Works
180 days
EDD-Sathiaon
See Tender Notice
5 documents required · 5 mandatory
₹1,180
EE ETD-II
₹10,000
31 Dec 2025
23 Dec 2025
31 Dec 2025
23 Dec 2025
31 Dec 2025
23 Dec 2025
23 Dec 2025 - 31 Dec 2025
Amount
fo|qr forj.k [k.M&lfB;kWo] vktex<+ ds vUrxZr 10 vn~n 33@11 ds0oh0 fo|qr midsUnzksa esa yxs 33 ,oa 11 ds0oh0 la;[email protected] ds fizosfUVo esuVsaul dk dk;Z foRrh; o"kZ 2025&26 ¼06 ekg eas 01 ckj½
budfeax iSusy Work involved- 1-Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value. 2-Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment contact resistance measurement of Vaccum Interrupter. 3-Checking and testing of closing/tripping machanism of breaker. 4-Replacement of weaker insulation control cables/Wiring. 5-Cleaning of Jaws and its greasing/oiling. 6-Cleaning of Busbar spout and replacement of spout with lesser IR Value. 7-Cleaning of PT,CT an CT spout. 8-Cleaning of Relays through suitable solvent. 9-Adjustment of setting of Relays as required and consequent testing. 10-Tighening of power and control cable connections. 11-Heating of panel through blower.
vkmVxksbax iSusy Work involved- 1-Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value. 2-Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment contact resistance measurement of Vaccum Interrupter. 3-Checking and testing of closing/tripping machanism of breaker. 4-Replacement of weaker insulation control cables/Wiring. 5-Cleaning of Jaws and its greasing/oiling. 6-Cleaning of Busbar spout and replacement of spout with lesser IR Value. 7-Cleaning of CT an CT spout. 8-Cleaning of Relays through suitable solvent. 9-Adjustment of setting of Relays as required and consequent testing. 10-Tighening of power and control cable connections. 11-Heating of panel through blower.
33 ds0oh0 fLop;kMZ dk dk;Z WWork involved- 1-Meggering of lightening arresters fo all 3 phases of all power transformers of the substations. 2-Mechanical adjustment of bus side and line side TPMO/Isolator,oiling and greasing of moving parts of ensure smooth operation.. 3-Mechanical adjustment as required of 33 kv breaker, Oiling and greasing of moving parts to ensure smooth operation. 4-Ensure local and remote operation of 33 KV breaker. 5-Cleaning of all switchgears.
fo|qr forj.k [k.M&lfB;kWo] vktex<+ ds vUrxZr 10 vn~n 33@11 ds0oh0 fo|qr midsUnzksa ds czsdMkmu dks ,VSUM dj fo|qr vkiwfrZ jh&LVksj djus dk dk;Z&
11 ds0oh0 fLopxh;j dk czsdMkmu esUVhuasl ¼budfeax ,oa vkmVxksbax½ 1-Attending flashing caused by any fault or other wise (This includes cleaning through suitable solvent, replacement of damaged CT and spout if required. 2-Work on Jaw contact (This includes mechaical adjustment, cleaning and/or replacement of jaws, as required. 3-Work on Vaccum Interrupter Bottle (This includes mechanical adjustment, cleaning and or replacement of bottles, as required. 4-Work on tripping closing coil (This includes mechanical adjustment, cleaning and or replacement of coil as required. 5-Work on tripping clutch (This includes mechanical adjustment, cleaning and/or replacement of clutch as required. 6-Replacement of tripping and closing shaft, as required. 7-Removal of flashing in Busbar spout and its replacement, as required. 8-Removal of flashing in CT spout and its replacement, as required. 9-Work on rackout gear and/or jack bush. (This includes greasing, Replacement, as required. 10-Replacement of damaged indoor/outdoor cable box of 11 kv cable. 11-Replacement of damaged staright through of 11 kv cable. Note- Any one Job as per the amount of work description given in the above job will be considrened as 1 job. All t & p and petty Material/ Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt washer, seals etc shall be arreanged by the firm.
33 ds0oh0 fLopxh;j dk czsdMkmu esUVhusal- 1-Attending breakdown caused by any fault or other wise (This includes. A-Cleaning/Repair/Replacement of CT,PT LA. B-Repairing/Replacement of damages line side and/or bus side TPMO. 2-Repairing/Replacement of damaged indoor/outdoor cable box of 33 kv level. 3-Replacement of damaged staright through of 33 kv level. Note- Any one Job as per the amount of work description given in the above job will be considrened as 1 job. All t & p and petty Material/ Consumables viz oil, grease, cloth, cleaning solvent, nut , bolt washer, seals etc shall be arreanged by the firm.
M/S GURU KRIPA TRADERS (BID ID -5782284)
Ms Varsha Construction (BID ID -5781224)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_2029614.xls
BOQ • 0.28 MB
Scheduleds.rar
Tender Documents • 0.87 MB
Termsandconditions.rar
Additional Documents • 1.06 MB
Download all tender documents and submit your bid