Executive_Engineer_NTKMD_PHED
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Overhauling of 11KV substation and allied electrical works at Janaswasthya Karigari Bhavan (Nijalaya) under NTKMD, PHE Dte.
2024_PHED_751426_1
PHE/NTKMD/e-13 of 2024-25
Open Tender
Project Work
Item Wise
20 days
WORK
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
6 Dec 2024
14 Sept 2024
30 Sept 2024
14 Sept 2024
28 Sept 2024
14 Sept 2024
Amount
For HT panel : Thorough testing and calibration of 11KV VCB 3 Panel distribution board at site: A) Disconnection of 11KV HT cables. B) Cleaning of entire panel by carbon cleaner to remove all carbon particles. C) Cleaning of all dismantled components to remove all carbon particles and sulphation to improve insulation resistor (IR). D) 11KV Breaker completely servicing, cleaning by CRC & checking of all parts and make it in proper condition. E) Cable and termination to be cleaned by carbon cleaner. F) After servicing of all switch gear & checking its IR with respect to earth and phase to phase, they are racked in service position & kept at ON condition. At this condition High Voltage testing. G) All over current and earthfall relays tested by secondary injection. H) IR value checking of PT & CT. I) Tripping test of Breaker by primary injection. J) After testing all the HT cables (11KV) reconnected for successfully charging of 11KV supply on put on load condition. For LT PCC panel : A) Thorough cleaning of entire PCC panel & lighting. B) Testing & servicing of Air Circuit Breaker C) Testing of all MCCB, SFU, CT etc. D) All tightness checking. [All reports should be submitted as per Annexure - I, II & III]
GST @18% of Total Value in Amount
CESS @1% of Total Value in Amount
ANJAN ENTERPRISE (BID ID -5636990)
BIJAN ENTERPRISE (BID ID -5637013)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .