Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹3.7 Cr+₹17.4 L (4.86%)Rejected-AOC KHASRA NO 265 281 288 VILL PARSAUN DASNA P O JINDAL NAGAR DISTT HAPUR UP 201015 | HAPUR | HAPUR | UTTAR PRADESH | 201015 | ₹3.7 Cr+₹17.4 L (4.86%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹4.5 Cr+₹96.9 L (27.1%)Rejected-AOC 115 118 VIKRANT TOWER 4 RAJENDRA PLACE 4 RAJENDRA PLACE NEW DELHI 110008 INDIA | WEST | DELHI | 110008 | ₹4.5 Cr+₹96.9 L (27.1%) | L3 | Rejected-AOC L3 bidder |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Bid validity declaration (Schedule C) (to be executed on non judicial stamp paper of Rs. 100/-) is not submitted in hard and soft copy. |
Tender Value
Refer Docs
EMD Value
₹6.9 L
Closing Date
17 Aug 2023, 1:00 pmClosed
SE CandP2
SE CANDP 2 PTCUL Dehradun
Construction of 01 no 132 KV Bay at 132 KV Substation Kashipur
2023_PTCU4_59097_1
PTCUL/CandP-II/SS-02/2023-24
Open Tender
Electrical Works
Item Rate
270 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,700
MD PTCUL
₹6.9 L
Dehradun
27 Feb 2024
27 May 2023
18 Aug 2023
27 May 2023
17 Aug 2023
16 Jun 2023
8 Jun 2023
Amount
Price Schedule-A (Supply of Material)
145 KV Horizontal Double Break isolator with earth switch
145 KV Horizontal Double Break isolator without earth switch
145 KV PT (Three metering Core with 0.2s class)132/110V with PT clamp with Rod type bushing (without thread bushing) and junction Box.
120 KV LA (10 KV, Gapless Type)
132 KV control & relay panel for feeder.
145 KV Bus post insulator solid core type.
Lattice type structure with N&B and anchor Bolts.
2.5 Sq.mm. 10 Core armoured copper control cable
2.5 Sq.mm. 06 Core armoured copper control cable
2.5 Sq.mm. 04 Core armoured copper control cable
MS Round 40mm dia
3 mtrs deep driven earth electrode 40mm dia
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Disc Insulator 120 KN
Suspension Fitting for ACSR moose Conductor
Tension Fitting for ACSR moose Conductor
ACSR Moose Conductor
C-wedge clamp suitable for ACSR moose to moose Conductor
CT Clamps suitable for AL Moose conductor
Suppy of 11 kv pole
Supply of 11 kv power cable (3 x 185mm2)
Jointing kit 3x185 Sqmm 11kv XLPE Cable (I/D)
Jointing kit 3x185 Sqmm 11kv XLPE Cable (O/D)
Cable mid joint kit 3x185 Sqmm 11kv XLPE Cable
Chain link fencing/Pale fencing 3.6 mtr high along with gates
Description of Work / Item(s)
Amount
Price Schedule-B (Erection of Material)
132 KV CVT (1Ph.)
132 KV CT (5 Core) (1Ph.), 200/100/1, 0.2S CL with Junction Box.
132 KV CT, 50/1, 0.2 S CL with Junction Box
Line Traps 1250A, 0.5mH
Coupling Device (Phase to Earth)
HF Cable
Carrier Equipment (Speech+Protection)
Carrier Equipment (Speech+Data)
Protection Coupler
AL Power Cable (PVC)-3.5Cx35Sq.mm
2Cx2.5Sq.mm Copper control Cable (PVC)
4Cx2.5Sq.mm Copper control Cable (PVC)
6Cx2.5Sq.mm Copper control Cable (PVC)
10Cx2.5Sq.mm Copper control Cable (PVC)
132 KV Circuit Breaker 3 Phase, SF6 type
LED Lights for Switchyard Lighting with complete fittings, Junction Box & mounting accessories
MS Flat 75 x 12 mm
145 KV Horizontal Double Break isolator with earth switch. work complete in all respect with earthing etc.
145 KV Horizontal Double Break isolator without earth switch work complete in all respect with earthing etc
145 KV PT (Three metering Core with 0.2s class)132/110V with PT clamp with Rod type bushing (without thread bushing) and junction Box.
120 KV LA (10 KV, Gapless Type)
132 KV control & relay panel for feeder with earthing etc.
145 KV Bus post insulator solid core type.
Lattice type structure with N&B and anchor Bolts.
MS Round 40mm dia
3 mtrs deep driven earth electrode 40mm dia
MS Flat 50 x 6 mm for 132kV & 33kV Switchyard
Disc Insulator 120 KN
ACSR Moose Conductor
Dismantling and laying of 11kv power cable work with jointing kit etc. complete in all respect
Dismantling and Erection of 11Kv pole .
Dismantling of chain link fencing/ Pale fencing
Erection of Chain link fencing/Pale fencing
Loading of material (132 KV CT, CVT, CB, LA, communication devices etc.) at 220 KV S/s Mahuakheraganj and then unloading with freight charges at 132 KV S/s Kashipur.
Price Schedule-B (Civil Works) for 132 kV Bay equipment & 132 kV Bus Extension
Supplying of gravels and spreading in switchyard area with 20mm nominal size in required thickness
Supply and Spreading of earth by earth work in excavation by mechanical means (Hydraulic)/manual means over surface area, consolidating each layer by ramming and watering including surface dressing by uprooting of bushes,shrubs etc. and their disposal as directed .
Construction of foundation of following structures including excavation and back filling of earth,sand filling, CC/ RCC works including centering and shuttering, reinforcement, supply & fixing of bolts etc. complete.
Foundation of 132KV Lightning mast Tower
Foundation of 132Kv Tower(Column) for busbar arrangement
Foundation of Circuit Breaker (3ph.)
Foundation of Current Transformer (1 Ph.) with junction box
Foundation of PT (1ph.)
Foundation of CVT(1ph.)
Foundation of Lightening Arrestor
Foundation of Bus post insulator solid core type.
Foundation of 145 KV Horizontal Double Break isolator with earth switch
Foundation of 145 KV Horizontal Double Break isolator without earth switch
Price Schedule-B Civil Work for extension of Pale & Chain link fencing
Earth work in excavation by mechanical means (Hydraulic)/manual means over surface areas including backfilling,disposal of surplus excavated soil as directed. Disposed earth should be neatly levelled and dressed.
Concreting in foundation and above plinth level including CC/RCC works, including cost of centering,shuttering,finishing and reinforcement .complete in all respect
CC in ratio of 1:4:8 ( 1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
CC in ratio of 1:1.5:3 ( 1 Cement : 1 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel bar reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
Bricks work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and superstructure above plinth : Cement mortar 1:4(1 Cement : 4 coarse sand)
12 mm cement plaster of mix. 1:4 (1 cement : 4 fine sand) including paint.
RCC Cable trenches with trench covers ( all sections) including all type of crossing and all metallic work to support cables and trench covers.
400 X 400mm size trench with minimum depth 400mm
600 X 600mm size trench with minimum depth 600mm
1000 X 1000mm size trench with minimum depth 1000mm
Description of Work / Item(s)
Amount
Total Price Schedule-A (Supply of Material) from BoQ1 sheet WITHOUT GST
Total Price Schedule-B (Erection of Material + Civil Works) from BoQ2 sheet WITHOUT GST
Add GST* Amount on (Total of Price Schedule-A + Total of Price Schedule-B above)
SHANZ POWERTECHS PVT LTD
SNS Technocorp Private Limited
SALASAR TECHNO ENGINEERING LIMITED
SNS Technocorp Private Limited
SALASAR TECHNO ENGINEERING LIMITED
SNS Technocorp Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .