Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H2₹9.2 L−₹1.0 L (10.0%)Accepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | H2 | Accepted-AOC H2 | |
| 2 | H1₹10.3 LRejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | H1 | Rejected-AOC H1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
2 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR OF CHHAJJA, SLAB, BALCONIES AND CONNECTED B/R WORK AT ZONE-I UNDER AGE (I) LANSDOWNE.
2024_MES_681867_1
8939/E8
Open Tender
Civil Works
Item Wise
150 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
30 Dec 2024
29 Oct 2024
4 Dec 2024
30 Oct 2024
2 Dec 2024
13 Nov 2024
Amount
M & L repair to overhang portion of chajja, facia, dropwall etc. for continuous work by providing PCC(1:2:4) Type B-0 and finished with CM(1:3) after taking down of damaged portion of RCC work by maintaining same level and inserting Reinforcement as required and finished the surface to match with the existing surface by providing same finish and making the edge water-dropping grooves complete all as specified and directed. Note:1.Height of work to be considered upto 12m from FFL of Ground Floor. 2.Cost of formwork shall be deemed to be included. 3.Reinforcement required to be provided will be paid separately under relevant item.
M & L for repairing of RCC column by necessary preparation, i.e., scrapping, cutting, chiseling, derusting, and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces and applying one coat of rust remover by brushing to the reinforcement to remove loose rust particles and allowing it for 2 to 3 hours. Insert the new reinforcement to the damaged portion by drilling holes at required distance, fill the epoxy into the hole by 2/3 of the hole and insert the reinforcement in the hole, and bind the reinforcement at the rusted portion of reinforcement. Apply cement slurry on the entire damaged area, and plaster the surfaces with cement, sand, and polymer liquid (in 1:3, 15% of cement by weight) and water as required, mixing properly, and plaster the surface to match with the existing surface by providing same finish.Finish evenly complete all as specified and directed. Note:1.Height of work to be considered upto 12m from FFL of Ground Floor. 2.Cost of formwork shall be deemed to be included. 3.Reinforcement required to be provided will be paid separately under relevant item.
TMT bar 10 mm and over cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
TMT bars 6 to 8 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for repairing of walls/Chhajja upto 12m with and including comprising of the following steps:- (1) Cleaning & drying thoroughly existing surface of walls/Chhajja for all foreign matters such as fungus, moss, dust, etc by wire brushing and removing the existing plaster surface (2) Apply 1st coat of Dr Fixit Raincoat Neo/Equivalent directly from the container (stir content well before use) with brush/roller on the vertical surface in SSD condition diluting 1 Ltr coating with 100mm clean portable water at the rate of 3-4Sqmt/ltr (3). Apply second coats of Dr Fixit raincoat Neo/Equivalent without dilution as waterproof top coat either by railer or brush with force at the rate of 3-4Sqmt/ltr complete all as specified and directed Note: 1.Work shall be carried out through authorised applicator of the product. 2.Qty of different Dr Fixit/Equivalent Compound must be use as the specifications by the company 3.Cost of formwork/scaffolding shall be deemed to be included.
M&L for preparation of old decorated surfaces of wall by removing existing putty/distemper till plaster level and applying two coat of Smartcare Hydroloc(by Asian) or equivalent and subsequent application of 2 Coat of Oil Emulsion Distemper over a coat of 2 mm Acrylic/WaterProofing Wall Putty(each Coat not less than 2mm). Note-1.Apply first coat of Smartcare Hydroloc (no dilution) with a forced coverage of 4-4.5 Sqm/L & allow it to dry for 6-8 hrs. 2.Apply 2nd Coat of Smartcare Hydroloc (no dilution) with coverage of 4-4.5 Sqm/L perpendicular to first coat & allow it to dry for 6-8 hrs. 3.The work of Smartcare Hydroloc treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. 4. Putty shall be measured and paid seperately under relevant Item
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM complete all as specified and directed.
Material & labour for Rendering 10 mm thick CM 1:6 on stone masonry surfaces or concrete surfaces complete all as specified and directed.
M & L plastering in two layers consisting of 10mm thick in CM 1:6 and top layer of 5mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid seperately.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint over one coat of primer on putty(where required)complete all as directed. Note- Putty will be measured and paid seperately.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of distemper oil emulsion using roller all as specified and prescribed by manufacture of paint and as directed . Note- Putty will be measured and paid seperately.
M&L for 2mm thick Acrylic/WaterProofing Wall Putty in two coats (each coat not less than 1mm) and surface finished even and smooth with sand paper complete all as specified and directed.
M & L for repair to sunken floor by provide water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed :- (a) Provide PCC 1 : 1.5 : 3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement. (b) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion. (c) Applying surfaces of bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. on complete sunken surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc including demolition of old sunken complete all as specified and as directed. (d) applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat would be paid separately.)
Demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified.
Mirror polishing on old marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick ( below or above ground level ) complete including removal of debries out side MD land complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in sub base, levelling course, etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed.
M&L for scratch & Joint free Glazed (Porcelain) Vitrified Tiles (GVT)/Polished Glazed Vitrified Tiles (PGVT) 9mm-10mm thick (square or rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36 sqm ie size 600*600 in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. Note : 1.Size and pattern/texture of GVT(Matt Finish)/PGVT(Glossy Finish) must be decide by Engr in charge 2.Glazed Coating on GVT/PGVT must not be less than 1mm.
All as per item No 21 above but as in skirting/ dado etc with and including 10mm thik backing coat in cement mortar 1:4 an wall complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors complete all as specified and as directed.
M & L for machine cut kota stone slab in flooring of steps 20-25mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and laid over and including and polishing complete all as specified and as directed.
Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed.
Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed.
S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets AZ 150 of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed.
M&L Pre- painted galvalume aluminum zinc coating GIbased Plainsteel sheet 0.50mm thick AZ 150 of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Valley Gutter fixed with necessary arrangement complete all as specified and directed.
M&L in for MS steel Hollow ,Joist, channel, angle, tee or tubular Section work in tubular trusses, purlins, rafter, tubuler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and as directed.
S&F SS Railing includng all fixing arrangement complete all as specified and directed.
Dismantaling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L for providing E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and painted with two coats of oil bound distemper incl making good all the disturbed portion complete all as spd & directed by GE/Eng-in-Charge.
Panwar Electrical (BID ID -3174575)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .