ASSISTANT ENGINEER,
Assistant Engineer LID and EW section Vaikom Municipality
Electrification of bus bay
2026_LSGD_830847_3
03/AE/LID EW/VKM/2025
Open Tender
Electrical Works
Percentage
180 days
VAIKOM
Please refer Tender documents.
7 documents required · 7 mandatory
₹335
Yes
Yes
23 Feb 2026
23 Feb 2026
3 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
Electrification of Bus Bay
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
OD341890/2025-2026:CHARGES FOR PREPARING DRAWING OF THE COMPLETE ELECTRICAL INSTALLATION AFTER COMPLETION OF THE PRESENT WORK AND PREPARING COMPLETION REPORT WITH KSEB SERVICE CONNECTION APPLICATION FORM AND SUBMITTING TO THE CONSUMER FOR AVAILNG 1 PHASE SERVICE CONNECTION/LOAD REGULARIZATION
OD341891/2025-2026:Earthing with GI earth pipe 1 meter long 40mm dia. medium class including providing 12mm dia. drilled holes minimum 6 Nos along the entire length in alternate arrangement ,Providing test joint using 2 nos 25x3mm GI strip minimum size 25 cm suitable shaped and tightly clamped to the pipe electrode
OD341892/2025-2026:SUPPLY AND INSTALLATION OF DUST AND VERMIN PROOF WALL MOUNDING METER BOX (300X300X170MM) SINTEX MAKE WITH BASE PLATE SUITABLE TO FIX SINGLE PHASE ENERGY METER, ONE SET OF 32 A,415 V HRC BAKELITE FUSE FITTING WITH HRC FUSE LINK, 32 A 2 WAY NEUTRAL LINK ETC
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_1414574.xls
BOQ • 0.31 MB
sbdelectribusbay.pdf
Tender Documents • 1.84 MB
Electrificationnit.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .