| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹34.4 L+₹3.2 L (10.1%)Rejected-Finance H NO 74 TILIYAPUR CB GANJ BAREILLY UP 243502 | BAREILLY | BAREILLY | UTTAR PRADESH | 243502 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹35.7 L+₹4.5 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹38.8 L+₹7.6 L (24.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
15 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Air Force, Bareilly
Garrison Engineer (AF) Military Engineer Services Bareilly - 243002
ADDITION ALTERATION IMPROVEMENT TO BLDG NO. P-30 LIVING IN OFFICERS ACCN AT AF STATION BAREILLY
2021_MES_495050_1
8627/E8
Open Tender
Civil Works
Item Rate
60 days
BAREILLY
CLASS D CATEGORY a(i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (AF), Bareilly
₹78,000
Yes
2 Feb 2022
15 Dec 2021
17 Jan 2022
15 Dec 2021
15 Jan 2022
29 Dec 2021
60 days
Amount
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick sub base with moorum/red bajri, rolled to consolidated to required gradient and camber complete all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 50mm thick PCC (1:2:4) type B-1, (using 20mm graded stone aggregate) as in flooring/ hard standing finishing even and smooth without using extra cement all as specified.
M&L for forming construction joint 30 mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and as directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for preparation of new or untreated surface of wall and applying two coats of white wash complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
M&L for steel work in tubular trusses including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240 complete all as specified and as directed.
M&L for mild steel plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe.410-W. (Gde-E-250, Quality-A) complete all as specified.
S&F mild steel screw bolts (machine made), with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of neck 5 to 10mm complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of zinc chrome primer complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for glossy finish chequered rubber moulded cement concrete tiles of size (30cm x 30cm) x 25mm thick, set, jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles laid over and including 20mm thick screed bed in CM 1:6 complete all as specified.
S&F in repairs designer POP cornices of cross sectional area n.exc. 50 sq.cm, finishing the surface smooth & applying one coat of gypsum primer all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L for suspended multi- stepped false ceiling with 12.5mm thick Gypsum board with frame work consisting of GI intermediate channel, perimeter channel, ceiling section of standard sections suspended from soffit / roof with help of rawl plugs, finally joints are filled with jointing compound and paper tape and finishing the surface smooth & applying white cement based putty to achieve true smooth surface complete all as specified and as directed. [Ceiling sections & boards: Gyproc of M/s Saint Gobain or equivalent in Armstrong/ Ramco Hilux]
M&L for preparation of new surface of ceiling and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed.
S&F stainless steel tubing of circular/ square/ rectangular in shape, thickness of wall not less than 3mm of grade AISI-316 (type Austenitic, anticorrosive in nature) as in railings/ grills/ designer work including cutting, bending, welding, fixing in any type of location with suitable SS dash fasteners and finally buffing all as directed by Engineer-in-Charge.
M&L for preparation of new surface of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed.
M&L for applying white cement based wall care putty (min 1.5mm thick) on wall to achieve the true smooth surface complete all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches pillars etc complete all as specified and as directed.
Taking down cement plaster any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar (1:6) on fair face of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete in ground floors and paving (below or above ground level) complete including filling under sunken floor and clean the surface (if any) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding / terrazzo dado etc (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, complete all as specified and as directed. Note:- Measured overall as fixed along the centre line over fittings and accessories.
S&F in repair rotational moulded three layered polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 ltrs capacity, hoisted and fixed in position complete all as specified and as directed in SSR Part I complete all as specified and as directed.
S&F in repair PVC ball valve 20 mm bore high pressure of PTMT with epoxy coating aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. (Min wt =210gms)
S&F 15 mm bore of galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F 20 mm bore of galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing old 20mm bore GI tubing with new fittings and connections in new or old location complete all as specified and as directed. Note:- Old GI pipe shall be retrieved from sol item No. 34 here in before.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with MS clamps complete all as specified and as directed.
S&F PVC (SWR) bends with access door any radius of bore 110 mm complete all as specified and as directed.
S&F PVC (SWR) bends any radius of bore 110 mm complete all as specified and as directed.
S&F cast iron floor trap, long neck type 100 mm dia of outlet without grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F 100 mm dia bore cast iron spun soil, waste and vent pipes in any length with or without ears, with lead joints, laid in trenches or in floors complete all as specified and as directed.
S&F CP grating 125 mm dia with or without hole to match the colour of floor tile complete all as specified and as directed. (Min Wt 40 gms)
M&L for 25 mm thick PCC (1:2:4) type B -0 (using 12.5 mm graded stone aggregates) complete all as specified and as directed.
M&L for PCC (1:5:10) type E-2 (using 40 mm graded stone aggregates) as in filling to sunken floor complete all as specified and as directed.
M&L for Nano polished vitrified tiles, coloured, first quality of size 600x600mm, 9 to 10mm thick as in Floors, set and jointed in cement slurry, finished with flush pointing in coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. [Note: The colour / shade / design of tiles shall be as approved by GE.]
M&L for Nano polished vitrified tiles, coloured, first quality for skirting cut from tiles of size 600x600mm, 9 to 10mm thick, to suit the size of floor tile, set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles over and including backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M&L for Digital printed coloured light shade glazed ceramic tiles of size (300 x 600)mm x 10 mm thick as on vertical surface such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry, and pointed in white and coloured cement to match with and including over 10 mm thick rendering in CM (1:4) complete all as specified and as directed.
M&L for Digital printed coloured dark shade glazed ceramic tiles of size (300 x 600)mm x 10 mm thick as on vertical surface such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry, and pointed in white and coloured cement to match with and including over 10 mm thick rendering in CM (1:4) complete all as specified and as directed.
S&F 18 mm thick single piece perfect Z-black sandwich granite work (table rubbed and polished) in wash hand basin platform, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including rounding exposed edges and making hole for gas pipe or like complete all as specified and as directed.
Removal to existing treatment from roof including brick tiles laid dry etc any thickness or description complete all as specified and as directed .
Demolition of Mud in roof any thickness including plastering & leeping complete all as specified and as directed.
M&L for roughening existing roof surface and provide PCC (1:2:4) type B-1 (using 20 mm graded stone aggregates) as in leveling course complete all as specified and as directed.
M&L for water proofing treatment of approachable roof over leveling course with following specifications:- (a) Average 10mm thick plaster in CM (1:3) mixed with polymer based water proofing compound when leveling coarse is still green. (b) After the surface is fully dried, applying a coat of bituminous primer @ 0.30 liters/Sq.m. (c) After primer, the entire roof surface shall be painted with hot blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg/Sq.m. (d) Over hot bitumen, polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg/Sq.m shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacture’s instruction and strict supervision of manufacture’s technical representation. (e) Laying brick tiles over a bedding layer of 20mm thick screed in cement mortar (1:4). The cement mortar screed shall be mixed with polymer based liquid water proof additive @ 5% by weight of cement or as per manufacturer’s specification /instructions and tiles joints shall be filled with polymer based cement proof joint filler manufactured by approved specification/instructions.
M&L for cutting out cracks to V- section in existing roofs, chajjas or similar work up to 40 mm deep and cleaning the same with water jets to get rid of any loose material and wetting, grouting with cement & sand mortar (1:3) mixed with liquid WPC complete all as specified and as directed .
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregates) as in coping, parapets, bed plates, kerb and the like, rounded or chamfered on edges complete all as specified and as directed.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, self rimming counter top, oval shaped of size 560x400x205mm including waste coupling complete fixed on granite counter complete all as specified and as directed. Note: Granite top shall be measured and paid separately. [Model: S2030103 of make: Cera or equivalent in Hindware/ Jaquar/ Parryware]
S&F in repairs vitreous china ware wash down water closet pan (pedestal pattern) white, single piece with integral vitreous china ware flushing cistern, soft closing PVC seat cover, fixing bolts etc complete all as specified and directed. [Model: C890446 BLAZE of make: Parryware or equivalent in Hindware/ Jaquar]
S&F in repairs angle cock 15mm dia, fancy type cast copper alloy, chromium plated with crutch handle complete all as directed. [Cat No. CON-053KN of make: Jaquar or equivalent in Marc/ Cera]
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. Make: Prayag/ RS Industries.
S&F in repairs Bib taps, 15mm bore, cast copper alloy, chromium plated with crutch handle, long body with wall flange, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed. [Cat No. CON-107KN of make: Jaquar or equivalent in Marc/ Cera]
S&F in repairs 15mm dia Pillar taps, cast copper alloy, with long neck, chromium plated fancy type with aerator, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. [Cat No. CON-021KN of make: Jaquar or equivalent in Marc/ Cera]
S&F stainless steel St 304, CP Grating doom 100mm dia complete all as specified and as directed.
S&F in repairs overhead shower 125mm dia with revolving joints (with body rotation), ABS body with face plate chromium plated with rubit cleaning system with and including 115mm long shower arm complete fixed to 15mm bore pipe with wall flange all as directed. [Cat No. OHS-1709 of make: Jaquar or equivalent in Marc/ Cera]
S&F in repair brass chromium plated Towel rail 600mm long complete all as specified and directed. [Cat No. AQN-7711 of make: Jaquar or equivalent in Marc/ Cera]
S&F in repairs brass chromium plated Towel ring 30mm dia, round complete all as directed. [Cat No. AQN-7721 of make: Jaquar or equivalent in Marc/ Cera]
S&F brass chromium plated Toilet paper holder with flap all as directed. [Cat No. ACN-1153N of make: Jaquar or equivalent in Marc/ Cera]
S&F 3 tier corner glass shelf with brass CP frame & 5.5mm thick toughened glass, 250mm radius complete all as directed.
S&F in repairs hand shower (Health Faucet) (ABS Body) with 1 meter long easy flex tube in chrome finish & wall hook, suitable for EWC complete all as directed. [Cat No. ALD-CHR-585 of make: Jaquar or equivalent in Marc/ Cera]
S&F in repair brass chromium plated Soap dish complete all as directed. [Cat No. AQN-7731 of make: Jaquar or equivalent in Marc/ Cera]
S&F in repair 5.50 mm thick looking mirror of size (600x450) mm size of approved quality fixed to walls with suitable stainless steel brackets and screws complete all as specified and as directed.
S& F hand dryer automatic sensor type, ABS body all as directed [Model: HDR-WHT-M04A of make Jaquar or equivalent as approved by the GE]
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil all as specified.
M&L for Reinforced cement concrete 1:1½:3, Type A1 using 20mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span concrete all as specified.
M&L for Reinforced cement concrete 1:1½:3, Type A1 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like concrete all as specified.
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete all as specified
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete all as specified
S&F high strength deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F high strength deformed TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F high strength deformed TMT steel bars 5mm to 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
M&L for non skid coloured ceramic joint free tiles of size 400x400mm, 7 to 8mm thick in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed in CM (1:4) complete all as specified.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified.
M&L for rendering 5mm thick in CM 1:3 on surfaces of ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for hardcore with broken stone or boulders of gauge n. exc. 63mm, deposited, spread and leveled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 75mm thick cement concrete PCC 1:3:6 type C1 using 20mm graded aggregate as in flooring/ hard standing/ plinth protection finishing even and smooth without using extra cement
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing shown on Sl. Page No. 176 of SSR Part-II-2020.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, supplying & fixing in opening as per specification & drawing shown on Sl. Page No. 180 of SSR Part-II-2020.
S&F 100mm long Butt hinges, extruded aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21 all as specified.
S&F 200mm extruded aluminium alloy tower bolts extruded sections anodized complete all as specified and as directed.
S&F extruded aluminium handle 150mm long fabricated type anodized all as specified.
S&F 250mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S&F 3mm thick figured glass, pin headed type and glazing with oil putty/ glazing clips in any size all as specified and as directed.
S&F Galvanized mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples
M&L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls & applying two coats of cement based paint all as specified and as directed.
S&F Stop valve 20mm dia of PTMT any colour high pressure screwed for iron pipe and fixed all as specified. (Minimum weight 92gms)
S&F PVC valve less, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle, brackets complete including PVC connection and outlet pipe all as directed. [Make: 'Slim line' of M/s Parry ware/ 'Champion' of M/s Hindustan Sanitary ware/ 'Sleek+' of M/s Hindware]
S&F vitreous china white flat back wash hand basin 550 x 440mm size including 15mm dia PVC connection 600mm long, brass CP waste coupling, 32mm dia PVC waste pipe, CI/MS brackets including cutting for and pinning in brackets or fixed with brass screws all as directed.
S&F Salt-glazed stoneware gully traps, 150x150mm size square mouthed, type 'S' all as specified
S&F in repair rotational moulded three layered polyethylene water storage tanks (cylindrical vertical with closed top) of 500 ltrs capacity, hoisted and fixed in position complete all as specified and as directed in SSR Part I complete all as specified and as directed.
S&F 20mm bore gun metal globe or gate valve with iron wheel heads Class-II, screwed both ends for iron pipe all as specified.
S&F vitreous china ware wash down water closet pan (pedestal pattern), white with 'P' or 'S' trap including PVC seat cover with mild steel chromium plated or aluminised hinging device, fixing bolts jointing to flushing cistern and flush pipe anti syphonage pipe etc. complete all as specified and directed
M&L for concrete bed to drain pipes of 150mm bore dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6, type C2 all as specified.
S&F PVC pipe 150mm bore, Schedule-40 laid in trenches and jointing with suitable jointing materials complete all as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking out old sub main copper/aluminium cable of various sizes from existing conduit/ batten complete all as specified and as directed.
Taking down old MCB DB all types including MCBs etc complete all as specified and as directed.
M&L for Point Wiring for one light/ fan/ bell point controlled by one way switch complete with 1.5 Sq.mm (nominal area) FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade drawn in and including concealed non-metallic rigid PVC conduit medium grade with all fittings (ISI Marked) not less than 20 mm external dia with all fittings but shall be increased as per actual site requirement accordance with clause no 19.125 of SSR part I fixed concealed in wall / ceiling etc including decorative modular cover plates (inner and outer) suitable for housing modular pattern switches / sockets / regulators etc along with necessary metal boxes flush mounting in the wall with and including 1.5 Sq.mm FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade as earth continuity wire complete all as specified and as directed. Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar (1:3) and finishing with existing finishes shall be deemed to be included in unit rates.
Description all as per Srl item No. 112 here -in- before but for One 5 pin socket outlet, 5/6 amps, on independent board complete all as specified and as directed.
Description all as per Srl item No. 112 here -in- before but for One 3 pin socket outlet, 5/6 amps, on same board complete all as specified and as directed.
Description all as per Srl item No. 112 here -in- before but point wiring with 2.5 sq.mm (nominal area) FR-LSH, PVC insulated unsheathed copper conductor single core multi stranded cable 650/1100 volts grade duly earthed with same cable as for wiring above and green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
M&L for sub main wiring with two single core 1100 V grade FR-LSH PVC insulated flexible copper conductor cable of size 4 Sq.mm and one single core PVC insulated FR-LSH flexible copper conductor cable green colour of size 4 Sq.mm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces complete all as specified and as directed.
M&L for sub main wiring with two single core 1100 V grade FR-LSH PVC insulated flexible copper conductor cable of size 6 Sq.mm and one single core PVC insulated FR-LSH flexible copper conductor cable green colour of size 6 Sq.mm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces complete all as specified and as directed.
M&L for sub main wiring with two single core 1100 V grade FR-LSH PVC insulated flexible copper conductor cable of size 10 Sq.mm and one single core PVC insulated FR-LSH flexible copper conductor cable green colour of size 10 Sq.mm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces complete all as specified and as directed. Note for Srl item No. 116 to 118:- Two single core cables along with earth wire and PVC conduit shall be measured as one unit length.
S&F modular switch 1 way 6A, 1 module complete all as specified and as directed.
S&F modular socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and as directed.
S&F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F modular fan regulator, step type 120W - 2 module complete all as specified and as directed.
S&F modular bell push 6A, 1 module complete all as specified and as directed.
S&F electric bell, single phase, AC, 230 volts complete all as specified and as directed.
S&F Angle holder (modular Type), insulated body with back plate for batten fittings complete all as specified and directed.
S&F ceiling rose, surface Bakelite, (65 x 50)mm, three terminals complete all as specified and as directed.
S&F concealed type GI Sheet / PVC enclosure for switches / sockets etc. complete with a 25 Amps modular type motor starter (2 Module) with one SPN 'Ç' curve MCB of capacity 25 Amps (2 Module) & a 20 Amps 3 pin socket (2 module) including electrical connections complete all as specified and as directed.
S&F wall/surface mounted type LED light fitting batten type complete with LED 1x 20 watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed. Make:- Philips Cat Part No BN021C LED22S PSU CW GR / Havells Cat Part No ENDURA LINEAR NEO BS 20W LED 865 SPC WH or equivalent of make Wipro.
S&F Wall/surface mounted type LED light fitting batten type complete with LED 1 x 10 watt (2 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed. Make : Philips Cat Part No BN 021 LED12S 6500 PSU GR / Havells Cat Part No ENDURA LINEAR NEO BS 10W 865 SPC WH or equivalent of make Wipro.
Taking down existing LED Bulk Head fitting 10W of any type along with suitable fixing arrangement, keep in safe custody without any damage and re-fixing the fittings in serviceable conditions at same location after necessary re-wiring /repairs as required satisfactorily complete all as specified and as directed.
S&F ceiling mounted recess type LED light fitting high performance low height LED down lighter, Robust PDC housing, narrow rim renders complete with LED lamp 1 x 12 - 15 Watt, extruded aluminium heat sink provide for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed. Make:- Philips Cat Part No DN296B LED20S-6500 PSU WH or Havells Model No INTEGRA GRAND DLR 15W LED 840S or equivalent of make Wipro.
S&F ceiling mounted sleek surface type LED light fitting high performance low height LED down lighter, Robust PDC housing, narrow rim renders complete with LED lamp 1 x 18 - 21 Watt, extruded aluminium heat sink provide for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed. Make:- Philips Cat Part No SM251C LED20S- 6500 PSU WH or Havells Model No ENDURA NEO HE SURFACE DLS 21W LED 857S or equivalent of make Wipro.
S&F Dome light Decorative wall light fixture made up of Polycarbonate, suitable for 9 - 10 W retrofit LED Lamp B22 base with and including lamp 1 x 9 W complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed. Make:- Havells Cat Part No 1 N x 9 W LED Lamp LHDL 06160099 or equivalent of make Philips, Wipro.
S&F LED light fitting 36 Watt, status high lumen output cast aluminium alloy toughened glass, IP 65/66 and wired with all accessories complete with and including GI bracket made out of suitable size GI pipe for fixing bldg security light and making connection by using three core flexible twisted copper wire of 23/0.0076 etc complete all as specified and as directed. Make :- Philips Model No BRP046 LED 36 CW MR S1 PSU GR, Havells Model No ENDURA CITY LITE PLAT PLUS SL35W LED 757 SAS YBOPC, Wipro Model No. Skyline Plus LR13- 501- XXX- 57-XX.
S&F Street Light bracket made of light grade GI pipe 32 mm bore and 1.20 mtr long duly bent to shape including 2 Pairs of MS Clamps made out of 40mm x 5mm with nuts, bolts, washers etc complete all as specified and as directed.
S&F LED Retrofit Lamp 12 Watt complete all as specified and directed. Make :- Philips, Wipro, Havells
S&F Ceiling fan 1200mm sweep, 5 star rated working on single phase, 230 volt, 50 Hz AC supply, white colour complete with down rod and canopy including electric connection from ceiling rose to fan connector with PVC insulated 3 core copper cable of size 0.75 sq.mm complete including taking down existing ceiling fan and handing over to AGE E/M Store all as directed. [Model. 'ES-50 Premium 5*' of make: Havells or equivalent in Crompton Greaves/ Usha/ Orient]
S&F wall mounted Cabin fan 400 mm sweep, , 1350 RPM, single phase, 230 volts AC, 50 Hz, complete with pull cord control for speed and oscillating mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete including taking down old unserviceable Cabin fan complete all as specified and as directed. Make- Orient Model No 400 mm Tornado Wall-50 or equivalent make of Usha or Havells. Note :- Unserviceable Cabin Fan shall be deposited in MES Store yard.
S&F Exhaust Fan of 300 mm sweep metallic body (Heavy duty) single phase 230/240 volts, AC, 900 RPM complete with and including making holes with louvered shutters including mounting frame and connecting the fan to ceiling rose including provision of three core flexible copper conductor cable of size 1.5 Sq.mm copper with not less than 0.5mtr long to connection including to inside out finishing the surface & white wash etc complete including taking down old U/S Exhaust fan complete all as specified and directed. Make :- Orient Model No - Orient 300mm or 12" H.D EX Fan/ Equivalent of Usha, Almonard. Note :- Unserviceable Exhaust Fan shall be deposited in MES Store yard.
Supply, fixing, installation and testing of storage type water heater (Geyser) 25 Ltrs capacity, BEE 5 star rated with steel inner tank and polycarbonate outer body including pressure valve & electric supply connection complete including grouting with nuts & bolts of 15mm dia 100 mm long for hanging the geysers, including PVC connection 15mm dia, 450mm long heavy duty suitable for hot & cold water connections complete including plastering and finishing of disturbed wall surface as per existing finish complete including taking down old U/S Geyser complete all as specified and directed. Note :- Unserviceable Geyser shall be deposited in MES Store yard. Make: AO Smith Model No AO Smith ELJ Series Storage Water Heater ELIV 25 Litre Vertical Type, Havells Model No Monza dx Vertical Type, Racold Model No Racold Platinum Plus Vertical Type.
S&F for flush mounting, factory made VTPN DBs MCCB DB's, IP-43 protection-IK09 with metal door with 160 Amps copper bus bar with 2 neutral bus bar, earth bar cables ties for cable management fully insulated bus bar with set of wires and door earthing for provision of MCCB 160 Amp as incomer and 12 No. MCB's SP as outgoing etc complete all as specified and as directed. Make:- ABB Cat Part No E-SVTDB M 4XT1, Module - Tmax XT1+12, 4 Way, Siemens - Cat Part No 8GB31571RC IP42, 4 Way or Legrand Cat part No. 5077 45 DPX³ 160+12, 4 Way.
Supply and fix in replacement of sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, double door with 100 Amp rated copper bus bar and metal door with IP - 43 and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and as directed. Make :- Legrand/ Schneider/ Siemens.
S&F MCCB 160 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified and directed. Make :- Legrand, Schneider, Siemens
S&F MCCB 100 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified and directed. Make :- Legrand, Schneider, Siemens
S&F MCB SPN (single pole and neutral), 240 volts, 63 Amps breaking capacity 10 kA, ‘C’ Series. etc, complete all as specified and as directed. Make :- Legrand, Schneider, Siemens
S&F MCB Triple pole and neutral, 415 Volts, 63 Amps, 4 Pole, breaking capacity, 10 kA, 'C' series etc complete all specified and as directed. Make :- Legrand, Schneider, Siemens
S & F MCB single pole 240 volts, 'B' curve of rating from 6 to 32 amps, with rupturing capacity 10 kA, including providing thimble for out going cables complete all specified and as directed. Make :- Legrand, Schneider, Siemens
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq.mm 3.5 core complete all as specified and as directed.
Removing excavated material (Soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
M&L for well burnt sub class 'B', modular bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and as directed.
Supply and laying 50mm bore light grade ISI marked GI tubing laid in trenches or inserting in horizontal boring for cable protection including fixing with MS Clamp, nut, bolts etc complete all as specified and as directed.
M&L for Horizontal boring under hard standing/ pavements or roads manually using suitable auger for insertion of medium grade GI pipe 50mm bore and making good the disturbed surface complete all as specified and as directed.
M&L for earthing complete with galvanized steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level) with top edge of the plate not less than 1.50 Mtrs below ground level connected to galvanized iron wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron or steel connected to earthing test point all as specified including 15 mm GI tubing medium grade and necessary fitting for protection of GI wire including laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point including testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site with leveling the ground complete all as specified an as directed.
Taking down safely existing Electric Meters of any size, any rating, and re-fixing the same after necessary repair / re-wiring and connecting the same as required at site satisfactorily complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .