Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAdmitted-Finance | ₹5.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.0 Cr+₹18.4 L (3.16%)Admitted-Finance BAKOLA JAMUGURIHAT SONITPUR ASSAM PIN 784182 | SONITPUR | ASSAM | 784182 | ₹6.0 Cr+₹18.4 L (3.16%) | L2 | Admitted-Finance |
| 3 | L3₹6.1 Cr+₹26.5 L (4.54%)Admitted-Finance | ₹6.1 Cr+₹26.5 L (4.54%) | L3 | Admitted-Finance |
| 4 | L4₹6.5 Cr+₹65.5 L (11.2%)Admitted-Finance | ₹6.5 Cr+₹65.5 L (11.2%) | L4 | Admitted-Finance |
| 5 | L5₹6.7 Cr+₹82.1 L (14.1%)Admitted-Finance | ₹6.7 Cr+₹82.1 L (14.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | K B Enterprises L3 | Sri Babul Nath L2 | M/S BERIWAL CONSTRUCTIONS L5 | M/s Zeliezhu & Sons L1 | BIJOY DEORI L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 588.62 | Sqm | 25 ₹14,715.5 | 5 ₹2,943.1 Lowest | 20 ₹11,772.4 | 65 ₹38,260.3 | 12 ₹7,063.44 |
| 2.00 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish,lead upto 50 m and lift up to 1.5 m. All kinds of soil | 588.62 | Sqm | 40 ₹23,544.8 | 25 ₹14,715.5 Lowest | 50 ₹29,431 | 95 ₹55,918.9 | 25 ₹14,715.5 Lowest |
| 3.00 | Carriage charges for removal of excavated Earth ( beyond 5km upto 10km per km) (588x 1.5=882 x 19.35 ) | 882 | Cum | 60 ₹52,920 | 200 ₹1,76,400 | 100 ₹88,200 | 995 ₹8,77,590 | 16 ₹14,112 Lowest |
| 4.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar | 4 | Cum | 1,200 ₹4,800 | 450 ₹1,800 Lowest | 2,000 ₹8,000 | 1,255 ₹5,020 | 1,400 ₹5,600 |
| 5.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 3 | Cum | 1,800 ₹5,400 | 1,000 ₹3,000 Lowest | 3,500 ₹10,500 | 2,225 ₹6,675 | 2,550 ₹7,650 |
| 6.00 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar | 2 | Thousand Nos. | 1,000 ₹2,000 Lowest | 3,000 ₹6,000 | 6,000 ₹12,000 | 1,785 ₹3,570 | 5,500 ₹11,000 |
| 7.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. | 230.25 | Cum | 200 ₹46,050 | 180 ₹41,445 | 230 ₹52,957.5 | 175 ₹40,293.75 Lowest | 200 ₹46,050 |
| 8.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete | 217.51 | Cum | 1,100 ₹2,39,261 | 450 ₹97,879.5 Lowest | 1,400 ₹3,04,514 | 1,345 ₹2,92,550.95 | 1,800 ₹3,91,518 |
| 9.00 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil | 290 | Sqm | 45 ₹13,050 | 35 ₹10,150 Lowest | 125 ₹36,250 | 95 ₹27,550 | 100 ₹29,000 |
| 10.00 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) | 75 | Cum | 5,000 ₹3,75,000 | 5,500 ₹4,12,500 | 8,000 ₹6,00,000 | 1,215 ₹91,125 Lowest | 1,800 ₹1,35,000 |
Tender Value
₹6.9 Cr
Closing Date
17 May 2022, 2:00 pmClosed
GM (C) RA
Neepco Bhawan, Guwahati
Construction of Senior Executive Transit Camp at Ward No. 2, Railway Station Road, Tezpur.
2022_NEEPC_113462_1
NIB No. 01 Dated 19-4-2022
Open Tender
Construction Works
Item Rate
730 days
Tezpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Yes
As per tender document
Exempted
10 Jun 2022
20 Apr 2022
18 May 2022
21 Apr 2022
17 May 2022
21 Apr 2022
21 Apr 2022 - 13 May 2022
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish,lead upto 50 m and lift up to 1.5 m. All kinds of soil
Carriage charges for removal of excavated Earth ( beyond 5km upto 10km per km) (588x 1.5=882 x 19.35 )
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Machine moulded common burnt clay tile bricks of class designation 12.5(1000brick = 2sqm )
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Under Foundation
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level : Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level: Concrete of M25 grade with minimum cement content of 330 kg /cum
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 89.65
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity)
Routine test (Test Load 1.5 times the Safecapacity)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used . : 450 mm dia piles
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6coarse sand) : With F.P.S.(non modular) bricks
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and thelike consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to IS 2645 inrecommended proportions including rounding off junction ofvertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarsesand) mixed with water proofing compound in recommendedproportion including rounding off junction of vertical andhorizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hotat 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at jointsof PVC sheet should be 100 mm wide and pasted to eachother with bitumen @ 1.7 kg/sqm).
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conformingto IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height includingcleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats25 mm to 115 mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoiningwalls upto 300 mm height including rounding of junctions ofwalls and slabs.(c) After two days of proper curing applying a second coat ofcement slurry using 2.75 kg/ sqm of cement admixed withwater proofing compound conforming to IS : 2645 andapproved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortarof mix 1:4 (1 cement :4 coarse sand) admixed with waterproofing compound conforming to IS : 2645 and approved byEngineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishingthe surface with trowel with neat cement slurry and makingpattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test.“Allabove operations to be done in order and as directed andspecified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and applying high performance self leveling epoxy floor coating in 2mm thickness of approved make/brand over one coat of epoxy primer over prepared surface by means of special spike rollers and other tools so as to remove all trapped air bubbles, and achieve smooth, glossy and leveled surface. (for gym)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : for parking :25 mm thick
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of size Tile 600 x 1200 mm
Providing and laying anti skid Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Pool tiles of size 500 x 500 mm
Size of Tile 1000x1000 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
"Wall painting with asian paints apcolite advanced emulsion paint of interior grade, the paint variety offers a rich matt finishwith fungus & mildew resistance, this paint is high washable and burnish-resistant approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. " Two coats
Exterior wall paint: Supply, Providing and applying of asian paints apex ultima, (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 3.28/10 sqm (external wall + compound wall)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (internal wall)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58 60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Frame size 65 x 150 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :1st class teak wood 50 x 20 mm
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia
Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 150x125x27x5 mm
Providing and fixing aluminium tower bolts, ISI marked , anodised (anodic coating not less than AC 10 as per IS:1868) transparent or dyed to required colour or shade,with necessary screws etc. complete : 300 x 10 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour casement/casementcum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.
Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm).
Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completelyfixed ventilator with S.S friction hinges (350 x 19 x 1.9)made of (big series) frame 67 x 60 mm , sash 67 x 80 mm& mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2mm and single glazing bead/double glazing bead ofappropriate dimension. (Area of window above 3.00 sqmupto 5.00 sqm).
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)
Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm).
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm)
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-incharge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with :Decorative veneer facings of approved manufacture
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (front, balconies)
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electrostatically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Acoustical ceiling - CONFERENCE ROOM
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat surface
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
(a) Hot finished welded type tubes. (Gate) (mild steel 10mm = 0.62kg/m)
(a) Hot finished welded type tubes. (compound wall) (112 x 2=224 x 0.62 =138.88 kg)
(b) Hot finished seamless type tubes. (Front Elevation)(front elevation, vertical structure in front of the building)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (for balconies and pergola)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete.(for pergola)
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard sectionaround the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).(louvers area 39.6 sq m)(39.6 sqm x 10 kg =396)
Providing, fixing, testing & Commissioning of uPVC SWR pipes (Type-B) for soil, waste and vent pipe conforming to IS : 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings and making good the floors, beams and walls with cement mortar where required complete of outer diameter.
75 mm O.D. For Vent Pipe
Providing & fixing of uPVC SWR pipes (Type-A) conforming to IS 13592 along with all required fittings like tees, bends, crosses with or without access doors jointed with approved solvent cement fixed to walls and making good the floors and walls with cement mortar where required complete.
110mm O.D. (Rain water - Terrace)
160mm O.D. POOL DRAIN
Providing and fixing uPVC pipes of 6 Kg./cm2 conforming to IS: 4985 including all fittings with or without access door i.e. bends, junctions, cowls, offsets, etc., and jointing with solvent cement, including cutting holes in walls and floors, wherever required and making good the same, complete as directed by the Project-in-Charge.
Providing and fixing uPVC Floor Drain of required size complete in all respects. 110 X 63 mm
Providing & fixing uPVC inlet fitting with one or more inlets fabricated from 110 mm outer dia uPVC pipe and solvent welded sockets and fixed to uPVC Trap and set in cement concrete as per drawing complete
Providing & laying cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm and down gauge) 75 mm in bed and all-round pipe.
For 110mm Pipe
For 63mm Pipe
For 50mm Pipe
For 40mm Pipe
Providing and fixing of 1 mm thick S.S grating of approved make including fixing to the floor trap / drain with cement mortar including cutting and making good of floor in all respect as per instruction & satisfaction of Project Manager complete .
Circular Grating for Floor Trap
Circular Grating for Floor Drain
Providing and fixing Cast Iron grating with frame to the inlet of rain water pipe including cutting holes in walls and floors wherever required and making good the same complete, as directed by the Project-in-Charge. 150 x 150 mm
Providing and fixing UPVC Floor Clean Out/Clean Out Plug(FCO/COP) with end cap for opening, complete in all respects. 100 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore.
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
20 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Excavating trenches of required width for pipes, cables, etc including excavation for sockets also including for cement concrete cradles, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Extra for excavating trenches for pipes, cables, etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m (Rate is over corresponding basic item for depth upto 1.5 m) Pipes, exceeding 300mm dia but not exceeding 600mm dia in all types of soils.
Providing, laying and jointing of UPVC drainage pipe confirming to IS 15328 - 2000 with all fittings such as bends, tees, elbow. The wall thickness of pipe and technical charactersticks confirms to IS 15328 - 2000 type SN 8. The fittings dimentions confirming to BS : EN 140121998. The jointing to be completed with rubber ring / solvent weld joint complete.
450 mm dia RCC pipes
250 mm dia
300 mm dia
450 mm dia
160 mm dia
Providing and laying cement concrete 1:4:8 ( 1 cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size) 100 mm thick alround RCC pipe including centering,shuttering and curing complete as per standard details.
250 mm dia
300 mm dia
Providing and laying cement concrete 1:5:10 ( 1 cement: 5 coarse sand: 10 graded stone aggregate 20 mm nominal size) upto haunches for RCC pipes including 100 mm thick bed concrete centering,shuttering and curing complete as per standard details. 300 mm dia
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply all materials, labour and constructing Septic tank of 1.5Mtr X 2MtrX 2.5Mtr effective depth in brick masonary with RCC baffle walls and making connection to soak pits as shown in drawing.
Supply all materials, labour and constructing rain water harvesting arrangement comprising the following:- a) C.I grating of 450x450mm at the outlet to the de-silting chamber. b) Construction of de-silting chamber of including builtin grease trap with baffle wall, filter chamber of 2000x1000x1800 size along with 3 layers of filter media consisting of 30cm depth silt free coarse sand, 30cm depth aggregate of 10-20mm size, 30 cm depth, boulder of 30 -40 mm size, 200 GSM geotextile layer below coarse sand anchored to wall complete, in 345mm thick brick masonry in cement mortar 1:4, base concrete in CC 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 20mm normal size) with 75mm projection all around, 50mm thick PCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm normal size) inside over the base concrete, neatly finished, internal plaster in cement mortar 1:3 (1 cement: 3 coarse sand) finished with neat cement, 200mm thick cement concrete slab in M-20 concrete with 10mm tor steelFilling pea gravel of 2-4 mm size, 600mm depth inside the dug well and at the annular space between bore and UPVC pipe. both ways @ 150mm C/c, necessary shuttering and curing, SFRC manhole cover and frame of Extra heavy duty, rungs @ 300mm C/c fixed with M-15 cement concrete blocks, necessary excavation, backfilling and disposal of surplus earth as directed and as per drawing. c) 1 Nos. Dug well of 4.5 meter depth with 3 meter dia. pre-cast ring of 1000 mm height and 150mm thick or R.C.C. Pipe NP2 with dry joints, 200mm thick cement concrete slab roof in M-20 concrete with 10mm tor steel both ways @ 150mm C/c, supported on 345mm thick brick wall masonry, necessary shuttering and curing, SFRC manhole cover and frame of heavy duty, necessary excavation, backfilling and disposal of surplus earth as directed and as per drawing. d) Drilling Bore hole of 40 mtr. depth from ground level in each dugwell, supplying and lowering perforated UPVC pipe of 160mm dia., 6 kg/sq.cm conforming to IS: 4985, UPVC blind plug at top and bail plug at bottom. e)Interconnecting pipe for filter chamber and filter bed with dug well with 3 nos. of 160 OD slotted/ plain UPVC pipe of 6 kg/sq.cm plugged at one end wrapped in geo-textile of 150 gsm.
Providing and fixing horizontal single/multistage centrifugal pumping set with CI body, bronze impeller, stainless steel shaft and induction motor mounted on common base frame, vibration pads accessories complete with control panel and level controllers with cabling as per specifications. Quoted rate shall include cost of Valves, piping for suction and delivery header inside pump room. Water Lift Pump To Over Head Tank Type of pump‐Horizontal (End Suction) Capacity ‐ 150 LPM Head ‐ 30 M (H.P. ‐ To suit)1 Set = 1 working + 1 Standby
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing toilet paper holder : (a) C.P. brass
Providing, Storage, Installing, testing and commissioning of "Rimless Single piece-WC with UF soft close seat cover, Hinges, Fixing Accessories, Accessories Set and Cistern fittings, Size:390x710x720 mm,P Trap -180 mm" including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Single Piece WC with UF Soft Close Slim Seat Cover, Fixing Accessories, Accessories set and Cistern Fittings,Size:370x670x720mm, S Trap 220mm"including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of"Hand Shower (Health Faucet) with 8mm Dia 1.2 Meter Long Flexible Tube and Wall Hook" including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of"Table Top Basin,Size : 575x430x175 mm" including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Vessel Basin Without Faucet Hole In Black, Superior material and Glaze : - Long Lasting, Durable Glaze -Easy to Clean Surface, resistant to chemicals and stains Dimension: 563 (L) X 403 (B) X 130 (H) mm, Depth: 114 mm" including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of Vanity 600mm Walnut including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Single Lever 1-Hole Bidet with Popup Waste System with 375mm Long Braided Hoses" Faucet for Wash Basin including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of "Shower Panels (Stainless steel) Stainless steel structure 3 adjustable vertical jets (Square) Moveable ABS top shower Thermostatic mixer with diverter Hand shower with flexible hose Brass Spout Minimum Water Pressure 2 bar Size: 1500 x 200 mm" including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "The combination of elegance and practicality makes the R840L a perfect solution for almost in all the corner positions.,Corner Shower Enclosure with two fixed glass and ,1 openable door fixed on side panel.,Finish: Chrome,Glass : 8mm,H: 1950, W: 1600 - 2000",overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Single Lever High Flow Bath & Shower Mixer (Concealed Body) Wall Mounted Model with Button Spout (Composite One Piece Body)" ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Maze Overhead Shower 300X300mm Square Shape Single Flow (Body & Face Plate Stainless Steel with Chrome Finish) with Rubit Cleaning System" ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Wall to wall shower enclosure with one fixed glass and openable door fixed on glass - 2 part enclosure,Glass: 8mm / 10mm,Finish: Chrome,Size - H: 1950 W: 800-1200" ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Single Lever Wall Mixer With Provision of Hand Shower, But W/O Hand Shower (Stainless Steel)" ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of "Bottle Trap (with Internal Partition) 32mm Size with 300mm & 190mm Long Wall Connection Pipes & Wall Flange Finish: Graphite" ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of Waste coupling 32mm Size Half Thread with 80mm height ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Providing, Storage, Installing, testing and commissioning of Angular Stop Cock with Wall Flange ,overflow arrangement with specials of slandered make and mosquito proof coupling of approved municipal design complete including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of towel rack 600mm long with lower hangers,stainless steel including painting of fitting and brackets ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of Stainless steel kitchen sink - with drain board 510x1040 mm bowl depth 225 mm ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of Two burner indian gas range ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of swivel towel holder twin type ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of Shower Basket Large ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of "Swivel Mirror Size: 630 X 445mm Rectangular Shape" ,cutting and making good the walls and floors wherever required: (washroom, gym and bedrooms)
Receiving, Storage, Installing, testing and commissioning of Glass Shelf 600mm Long,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of "Automatic Soap Dispensers, Capacity : 0.8L, Material: Aluminium/ABS, Finish : Chrome/Black" ,cutting and making good the walls and floors wherever required:
Receiving, Storage, Installing, testing and commissioning of "Soap Dispenser with Glass bottle colour(Black Chrome)",cutting and making good the walls and floors wherever required:
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved qualityconforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing, Storage, Installing, testing and commissioning of S.S braided EPDM lined flexible connector of 450mm long with C.P brass nuts and washers complete.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 m solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
8 way , Double door
12 way , Double door
16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
3 X 10 sq. mm (22mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm
Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage with out any separate power supply from 100 to 270V AC, 50Hz, power factor>0.9. Fixture shall be suitable to operate at ambient temperature range of-10°C to + 50° Cand shall be IP65 and IK06 rated. Lifetime should beat least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BI Sand shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables,water proof connectors etc. as required. 25 W (Delhi Schedule of Rates & Delhi Analysis of Rates (E&M) (Items for FAÇADE LIGHTING)
SITC with Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required.
All Incoming / bus coupler / Outgoings MCCB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site.
All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.
The breaking capacity specified for all MCCB's breakers is Ics value (service rating).
Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose.
All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.
The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.
The maximum height of the panel should not exceed 2100 mm unless specifically approved.
GA drawings shall be got approved from Owners / Architects / Consultants before fabrication.The panel has to be specifically fabricated as per the space available at basement level. The existing column positions will also be considered.
MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL
INCOMERS from Electrical LT Meter
315 AMP Four Pole MCCB (25 KA) with 400 A FP contactor
The MCCB shall be electrically interlocked with the bus coupler, DG incomers .
1 nos.63 amp TP MCCB (25 KA) for Fire Fighting Pump Panel.
Protection releases / relays, Metering & Accessories for each Transformer incomers
Over Voltage / Under Voltage relay / release with timer.
Provision of Restricted earth fault relay.
Reverse Power relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 315/5A, Class 1.0 accuracy 15 VA burden for metering.
INCOMERS from 1 NOS 100 KVA & NOS 50 KVA D G sets
1 nos. 200 AMP. FP MCCB (25 KA) & 1 nos. 250 AMP Four Pole contactor
1 nos. 100 AMP. FP MCCB (25 KA) & 1 nos. 125 AMP Four Pole contactor
MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release with timer.
IDMT earth fault relay.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Reverse power relay.
Voltage restrained over current relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 200/5A & 100/5A Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 200/5A & 100/5A , Class 5P20 accuracy 20 VA each burden for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
9 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for each DG sets 1 nos 100 kVA & 1 nos 50 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically interlocked with the bus coupler and Transformer incomers.
D G Sets shall have controller to start / stop / synchronization facility. The protective relay in DG incomer feerder shall be modified based on the facility avalable in the controller of the respective D G Sets
Bus PT Module 2 Nos., each with Following:
3PH. 415/v3/110/v3 V 100VA with Fuses.
R,Y,B Ind. Light with Control Fuses
Voltage Relay
BUS COUPLER
400 AMP Four Pole , MCCB (25 KA) with 500 A FP contactor
MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL
Protection releases / relays, Metering & Accessories for Bus Coupler (s)
Trip circuit supervision relay
TNC switch.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
BUS BARS
2 sections of 400 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints.
The current density of bus bar up to 1000 Amp shall be minimum 1.00 sq mm / amp & for 1250 / 1600 amp shall be minimum 1.30 sq.mm / amp and for 2000 / 2500 / 3200 Amp shall be minimum 1.60 sq mm / amp.
CHANGE OVER SWITCH
1 Nos. 63 A four pole On Load Change Over switch for Fire Pump feeder.
PLC for load management / automation
Design, manufacturing, testing at works, supply of PLC BASED , AUTOLOAD TRANSFER, AUTOLOAD BALANCING PANEL FOR sets complete as required to acheive the desired functions. (Make : ALLEN BRADLEY / SIEMENS / MITSUBISHI / ABB)
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.
PLC is not envisazed for D G synchronization
In addition to required hardware and software following components shall also be provided.
Based on the load requirement only required no. of DG sets shall be operated.
Monitoring of DG set safeties (mechanical as well as electrical).
PLC Hardware as required
Auxiliary relays/contactor/metering/protection etc as required
230 V AC, UPS of suitable rating alongwith batteries
Annunciators as required
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.
Gas flooding system for fire control nsisde panel du e to short circuit shall be incorporated.
OUTGOINGS -
All feeders shall be provided with energy analyser / electronic dual reading KWHR meter with RS 485 communication port, CT's with accuracy class 1, control circuits and wiring as per SLD.
MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL
4 no. 125 AMPS TP MCCB. (25 KA)
4 no. 63 AMPS TP MCCB. (25 KA)
1 no. 40 AMPS TP MCCB. (25 KA)
Main LT Panel as described above
Supply of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect.The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, flame proof double compression glands, including supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-in-charge. (Make : Universal (Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR) Armoured
2 x 4 sq mm armoured
4 x 2.5 sq mm armoured
6 x 2.5 sq mm armoured
10 x 2.5 sq mm armoured
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. (Make : Universal (Satna) / CCI / Nicco / Finolex / Polycab / Skytone / RR
6 sqmm 2 core
10 sqmm 2 core
16 sqmm 2 core
10 sqmm 3 core
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 4 core
35 sqmm 4 core
50 sqmm 3 1/2 core
70 sqmm 3 1/2 core
95 sqmm 3 1/2 core
150 sqmm 3 1/2 core
Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required.
Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required.
Providing & fixing 50mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. as required.
CCTV 2 Megapixel IP IR Dome Camera :- Supply, installation, testing and commissioning of UL Listed 2 Megapixel,1/3" progressive CMOS Vandal-proof, Network Dome Camera ,Day &Night IR cut filter with auto switch,Digital WDR,3D DNR,Video Compression H.264/MJPEG, ,Minimum Resolution 1920 x 1080:25fps, Built-in Micro SD/SDHC/SDXC card slot, up to 64 GB ,Line Crossing, Intrusion Detection, Motion detection, Dynamic analysis,One-key reset, Flash-prevention, dual stream, heartbeat, mirror,Standard ONVIF, PSIA, CGI, ISAPI,Operating Conditions,-30 °C – 60 °C (-22 °F – 140 °F),PoE (802.3af), IR Range 30 meters, Ingress Protection,Backlight compensation, 0.01Lux @ (F1.2, AGC ON) ,0 Lux with IR, 0.028 Lux @ (F2.0, AGC ON) ,0 Lux with IR,4mm @ F2.0 lens (2.8mm, 6mm optional),including RJ45 connector for connection etc. required for commissioning. (Make: Honeywell / Samsung /Sony/D-link,HIK VISION )
CCTV 2 Megapixel IP IR Box/Bullet Camera :- Supply, installation, testing and commissioning of UL Listed 2 Megapixel,1/3" progressive CMOS Vandal-proof, Network Box/Bullet Camera ,Day &Night IR cut filter with auto switch,Digital WDR,3D DNR,Video Compression H.264/MJPEG,Minimum Resolution 1920 x 1080:25fps, Built-in Micro SD/SDHC/SDXC card slot, up to 64 GB ,Line Crossing, Intrusion Detection, Motion detection, Dynamic analysis,One-key reset, Flash-prevention, dual stream, heartbeat, mirror,Standard ONVIF, PSIA, CGI, ISAPI,Operating Conditions,-30 °C – 60 °C (-22 °F – 140 °F),PoE (802.3af), ,IP66, Impact Protection IK08,IR Range 50 meters, Ingress Protection,Backlight compensation, 0.01Lux @ (F1.2, AGC ON) ,0 Lux with IR, 0.028 Lux @ (F2.0, AGC ON) ,0 Lux with IR,6mm@ F2.0 lens (4mm optional),Including Bracket,including RJ45 connector for connection etc. required for commissioning.(Make: Honeywell / Samsung /Sony/D-link,HIK VISION )
Supply, installation, Testing and Commissioning of UL listed NVR . This shall support minimum 5 clients and include the required hardware cost and the software cost for the same as per the system requirement. APP allows a quick remote access and control via mobile phone, having minimum 25 Mbps Incoming bandwidth & 80Mbps Outgoing bandwidth & recording resolution of video all channel suitable for 1080 realtime /nonrealtime Live view,H.264/MJPEG dual core decoding,Max 240fps@1080p,480fps @720p,960 fps @D1 preview & recording,Up to 5Mp resolution,Support minimum 4 SATA solt for hard disk , 2 USB 2.0,should have 2HDMI ports & 1 VGA port for simultaneous video output,Support Multi-brand Network camera, ONVIF Version 2.0 with input voltage of 240 V AC, suitable Hard disk required for 15 days recording (calculations to be submiited by vendor) complete as per specifications, DVR should be of same make as Cameras .(Make: Honeywell / Samsung /Sony/D-link,HIK VISION ) 16 Channel
Supply,installation,testing and commissioning of 10/100/1000 Fast Ehernet L2 Managed stackable switches- All PoE managable network switch with 2x Giagbit ports or 2xSFP slots for Fiber modules with suitable POE budget for camera rating & upto 4 KV surge protection for camera & POE Port etc required for commisioning.(Make: HP/DIGISOL/D Link/Cisco/HIK VISION ) 24 Port
Supply,installation,testing and commissioning of following port loaded jack panel for CAT6 Cable termination .(Make: HP/DIGISOL/D Link/Cisco/Legrand) 16 Port
Supply,installation,testing and commissioning of following port loaded LIU with adaptor plates , pigtel cables for connections .(Make: HP/DIGISOL/D Link/Cisco/Legrand) 16 Port
Supply , Installtion , Testing and comissioning of CAT6 patch cord 3 feet for rack side switch termination. (Make: HP/DIGISOL/D Link/Cisco/Legrand)
Supply , Installtion , Testing and comissioning of SC-LC Single mode fiber patch cord . (Make: HP/DIGISOL/D Link/Cisco/Legrand)
Supply, Installation, Testing & Commissioning of Fibre Modules 1000BASE-SX SFP connector.
Supply,installation,testing and commissioning of 40" CCTV colour Led Monitor including all accessories complete as required.(Make: Sony/Samsung )
Supply, installation, testing and commissioning of floor standing 19 " communication Rack with front glass door with lock and key arrangement, rear MS door, passive and active mountable space with active switch installable space, horizontal power manager, cable manager, twin fan, cantilever tray and castor wheel fixed complete as required. link,Rittal,Legrand/MTS/APW) 32U
Supply, installation, testing and commissioning of wall mounted Rack with front glass door with lock and key arrangement, rear MS door, passive and active mountable space with active switch installable space, horizontal power manager, cable manager, twin fan, c complete as required. (Dlink,Rittal,Legrand/MTS/APW) 6U
Supply, Installation, Testing & Commissioning of on line UPSas per following details :- [Make : APC-Schneider / Emerson / Eaton]
Technology : Micro processor based controls, True on line, Double conversion type, should have cold start facility.
Input :- (mains / local D G set compatibility)
a) Voltage : 230 V / 1 Phase
b) Voltage Variation : - 20% to + 20%
c) Input Frequency : 50 Hz.
d) Frequency Variation : + 10%
Output :-
a) Voltage : 230 V / 1 Phase
b) Voltage Variation : + 1%
c) Frequency Variation : 50 Hz. + 0.1%
Overall Efficiency : > 90%
Charger : Should have built in charger to suit system requirement.
Battery type : Sealed Maintenance Free - SMF (Global Yuasa / Exide)
Back-up time : 20 Min. with SMF batteries
Rating : 1 KVA
Providing & Fixing of white RJ 45 Cat 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, UL listed, for computer networking complete in all respect suitable to fix in existing modular plate type switch system with connections as required.
1 nos. RJ 45 Data Outlet
2 nos. RJ 45 Data Outlet
Supply, installation, testing and commissioning of enhanced category 5 patch panels suitable to meet or exceed TIA and ISO component performance requirement, universal wiring may be terminated to T568A or T568B standards with lables and suitable for mounting on to 19" communication rack. The complete formation shall be suitable for 480 nodes. 24 ports
Supply, installation, testing and commissioning of enhanced category 5 patch cords exceeding Category 5e performance standards, 4 pair stranded UTP, 24 AWG conductors, non plenum, size 7 ft. and 10 ft.
Supply, installation, testing and commissioning of enhanced category 5e mounting cords 7ft. both side factory fitted RJ 45 connector.
Supply, installation, testing and commissioning of enhanced category 5e mounting cords 3 ft. both side factory fitted RJ 45 connector.
Supply, installation, testing and commissioning of 25 pair riser cable, 24 AWG.
Providing, fixing, connecting & testing of Krone box (Telephone Tag Block) in a thermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive, insulated and shock proof with provision for cable through IP 65 glands complete in all respects. (Make : Hensel)
10 pair krone
50 pair krone
Providing, laying, connecting, testing & commissioning of multi-core telephone unarmoured cables of conductor size 0.5 sq.mm. annealed tinned electrolitic grade copper, PVC insulated, twisted pairs bunched together, wrapped with melinex tape and over all PVC sheathed to be laid in existing conduit/pipe/cable trey as required complete in all respects. (Make : Finolex / RR / Polycab / Skytone)
Providing, laying, connecting, testing & commissioning of multi-core telephone armoured cables of conductor size 0.5 sq.mm. annealed tinned electrolitic grade copper, PVC insulated, twisted pairs bunched together, over all PVC sheathed, GI strip or wire armouring laid on existing cable tray or along the wall or laid in pipes or in trenches including excavation of cable trench, sand filling covering with bricks and back filling complete as required. (Make : Finolex / RR / Polycab / Skytone) 10 pairs
Providing, fixing, connecting & testing of Ceiling LED Lights (15w) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Ceiling LED Lights (5w) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Exhaust fan 450 mm sweep ( USHA crisp air premia as plus) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Convertible 5-in-1 Inverter AC AR18AY5YBTZ, 5.00kW (1.5T) 5 Star Samsung with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Water Heater (Havells Bianca 25 Litre 5 Star Storage Water Heater) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Hand Dryer Machine (DOLPHY Plastic Automatic Hand Dryer) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Providing, fixing, connecting & testing of Kitchen Chimney ( Faber HOOD SUNNY HC SC BK 60 ) with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
KITTLE & BIG TRAY : Supply, Installation, Testing and Commissioning of DOLPHY only kittle 304 ss + matt finish 0.8LTR & high quality melamine big tray with complete accessories including painting of fitting and brackets ,cutting and making good the walls and floors wherever required.
Sri Babul Nath
K B Enterprises
BIJOY DEORI
M/S BERIWAL CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .