Loading…
Loading…
Tender Value
₹34.2 Cr
EMD Value
₹68.3 L
Closing Date
21 May 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual Contractual Turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Bid CAPACITY The tenderer will be qualified only if its available bid capacity equal to or more than the total value of the present tender. The available bid capacity shall be calculated as under; Available Bid Capacity = [A x N x 2] - 0.33 x N x B Where A = Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender), taking into account the completed as well as works in progress. N = Number of years prescribed for completion of work for which bids has been invited. B = Existing commitments and balance amount of ongoing works with the tenderer as per the prescribed proforma of Railway for statement of all works in progress and also the works which are awarded to the tenderer but not yet started up to the date of inviting tender.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar Nature of work means, "Any signal interlocking works involving EI or RRI or PI or IBS or LC gate interlocking or UFSBI or Track Circuit AFTC or (SSDAC or MSDAC or HA-SSDAC) or Automatic Signaling."
3 conditions · 1 needing a document upload
1. Earnest money deposit (scanned copy of the instrument to be a t t a c h e d ) 2. Experience certificate (scanned copy of the credentials to be attached) 3. Turn over details (scanned copy of the attested certificates from the employer/ client, audited balance sheet duly certified by the chartered accountant etc., to be attached) 4. Details of strength of staff employed
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
All works tenders or service tenders invited by railways through e- tendering on IREPS, having advertised value of Rs 10 lak h and above, contractors are eligible to take payment from Railways through a Letter of credit (LC) arrangement. (Ref: RB letter no.2018/CE-I/CT/9 dated 04.06.18) ( i ) F o r a l l the tenders having advertised cost of Rs 1 0 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement. (ii) This option of taking payment through LC arrangement h a s t o be exercised in !REPS ( I n d i a n Railway Electronic Procurement System - the e-application on which tenders are called by Railways) by the tenderer at the time of bidding itself, and the tenderer shall affirm having read over and agreed to the terms and conditions of the LC option.(iii) The option so exercised, shall be an integral part of the bidder's offer. (iv) The above option of taking payment through L C arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract. (v) In case tenderer opts for payment through LC, necessary procedure for LC mode of payment shall be followed to deal release of payment through LC:
Provision of indoor and outdoor Signalling & Telecommunication arrangements at Thiruvananthapuram Central station, Signalling and interlocking arrangements at LC gates and Indoor and outdoor Signalling & Telecommunication alterations at Thiruvanathapuram South station to suit Twin single line between Thiruvananthapuram Central and Thiruvananthapuram South stations in connection with doubling of track between Thiruvananthapuram Central & Kanniyakumari stations.
ERS-SG-CN-03-2026
ERS-SG-CN-03-2026
Open
Works - General
6 Months
Ernakulam, Kerala
₹0
₹68.3 L
21 May 2026
29 Apr 2026
7 May 2026
354 items across 9 schedules · ₹29,17,97,789.59 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with a l l accessories s u c h a s key board, mouse, antivirus e t c . o f industrial g r a d e as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI | Numbers | 3.00 | 3,75,562.03 | 11,26,686.09 |
| 2 | Supply o f Power Supply arrangement for VDU and Embedded PC. This includes supply of 2Nos o f 110VDC/24DC, 1 0 A DC- DC converter a n d 2 N o s o f 110VDC/110V AC, 500VAInverter in (1+1) configuration. (as per Technical Specification enclosed) | Set | 3.00 | 2,14,096.98 | 6,42,290.94 |
| 3 | Supply of Double Key Lock | Numbers | 2.00 | 481.77 | 963.54 |
| 4 | Supply and Installation of work space as per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement) | Numbers | 1.00 | 9,48,672.1 | 9,48,672.1 |
| 5 | "Training of Railway Personnel in installation, commissioning, testing, troubleshooting and in diagnosing faults using diagnostic tools/flow charts including supply of necessary documents. (Per Unit= 60 Man Days)" | Per Unit | 1.00 | 72,995.54 | 72,995.54 |
| 6 | " C a r r y i n g o u t A u t o m a t i c Factory Acceptance test f o r a n y statio n having Distributed EI configuration" | Station | 1.00 | 3,05,105.92 | 3,05,105.92 |
| 7 | "Carrying out Automatic Site Acceptance test for a n y station having Distributed EI configuration" | Station | 1.00 | 9,73,868.46 | 9,73,868.46 |
| 8 | Preparation o f circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared i n A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad v e r y carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy | Sheet | 400.00 | 218.3 | 87,320 |
| 9 | Preparation o f circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared i n A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad v e r y carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.c)Preparation of soft copy in AUTO CADD from U size hard copy | Sheet | 6.00 | 1,548.45 | 9,290.7 |
| 10 | "Supply, of Datalogger with 512 Digital Input and 3 2 Analog Input a s p e r RDSO specification No. IRS:S-99/2006 Amdt 3 (or) l a t e s t w i t h p o w e r s u p p l y arrangements. (This work does not includes wiring of inputs from Relay to Intermediate tag block & from intermediate t a g b l o c k to Datalogger equipment)" | Numbers | 2.00 | 4,46,627.2 | 8,93,254.4 |
| 11 | "Supply of RTU of Capacity 128 Digital and 16 Analog as per RDSO spec .no IRS-S- 99/2006 or latest including Power Supply and Back- up arrangements" | Numbers | 2.00 | 2,47,800 | 4,95,600 |
| 12 | " S u p p l y o f Fa u l t Analysis Terminal for analysis of fault and generating reports for Datalogger installed a t stations. A s per Technical Specifications." | Numbers | 1.00 | 54,723.27 | 54,723.27 |
| 13 | Supply o f Protocol Converter suitable for Electronic Interlocking system equipment | Numbers | 1.00 | 68,051.41 | 68,051.41 |
| 14 | S u p p l y o f D u a l C a r d R S 2 3 2 t o EI/OFC converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP | Numbers | 1.00 | 45,367.61 | 45,367.61 |
| 15 | Supply of External 4wire leased line modem for enabling RTU connectivity with Dataloggers at Stations | Numbers | 1.00 | 39,622.8 | 39,622.8 |
| 16 | S u p p l y o f isolation transformer 600:470 ohms as per IRS TC 76-2001 amd 1 or latest | Numbers | 20.00 | 791.12 | 15,822.4 |
| 17 | Supply of Opto to USB Ports for Interfacing Datalogger with Data Analyser | Numbers | 1.00 | 7,377.54 | 7,377.54 |
| 18 | "Installation o f Datalogger o f Capacity 512 D i g i t a l a n d 3 2 A n a l o g . T h i s includes transportation o f materials t o Site location a n d provision o f Ladder a n d cable trough arrangements including connection t o the BRC earth. Also includes carrying out of pre- commission checklist a n d Networking of datalogger. (This schedule doesn't cover wiring and preparation of simulation chart)" | Numbers | 2.00 | 29,500 | 59,000 |
| 19 | "Preparation o f Simulation Database which includes chart preparation f o r on-line and off-line simulation f o r display i n V D U for station o r A u t o section. ( P e r U n i t = Per Datalogger)" | Per Unit | 3.00 | 59,000 | 1,77,000 |
| 20 | "Installation of RTU o f Capacity 128 Digital and 16 Analog. This includes transportation of materials to Site location and provision of cable t r o u g h arrangements including connection t o the BRC/Location earth. This also includes carrying out of pre- commission checklist and Networking of datalogger. (This schedule doesn't cover w i r i n g and preparation of Simulation chart)" | Numbers | 2.00 | 23,600 | 47,200 |
| 21 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 1200.00 | 285.86 | 3,43,032 |
| 22 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 96.00 | 285.86 | 27,442.56 |
| 23 | Installation o f Fault Analysis Terminal (for analysis of fault and generating reports for Datalogger installed at stations) | Numbers | 1.00 | 23,452.83 | 23,452.83 |
| 24 | Installation of isolation transformer 600:470 ohms as per IRS TC 76-2001 or latest | Numbers | 20.00 | 339.05 | 6,781 |
| 25 | Preparation of station specific Train Arrival and departure logics for a six road station or less | Numbers | 1.00 | 1,63,559.06 | 1,63,559.06 |
| 26 | C a r r y i n g o u t E m b e d d e d software modification in Datalogger t o communicate with the data entry terminal of the ASM and pass the information through the datalogger network. | Numbers | 1.00 | 32,711.81 | 32,711.81 |
| 27 | C a r r y i n g o u t E m b e d d e d software modification in (1) FEP in control office and ( 2 ) C M U i n control office, t o accept and transfer the relevant station data to a client PC | Numbers | 1.00 | 1,36,299.22 | 1,36,299.22 |
| 28 | Supply and Provision of indicative type Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of t h e Engineer i n charge at site ( OBO, DEHN, PHOENIX, L P I , ZOTUP, H A K E L or better make).All other m i s c e l l a n e o u s m a t e r i a l s required for installation s h a l l b e s u p p l i e d b y the contractor. | Numbers | 15.00 | 6,328.8 | 94,932 |
| 29 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per t h e instructions o f the Engineer in charge a t s i t e ( O B O , DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation shall be supplied by the contractor. | Numbers | 12.00 | 6,830.72 | 81,968.64 |
| 30 | Supply a n d Provision o f Earthing a s per RDSO Specification RDSO/SPN/197/2008 or l a t e s t ( a s p e r Te c h n i c a l Specification enclosed) | Numbers | 22.00 | 28,118.51 | 6,18,607.22 |
| 31 | " S u p p l y a n d p r o v i s i o n o f Earthing arrangements for EI/MSDAC buildings as per RDSO specifications as required for the EI system along with supply o f all required materials. Earthing shall b e carried o u t as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S D t 26.07.2011 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall o f relay room as per the instruction of Site In-charge.(Per unit= Per goomty/station)" | Per Unit | 4.00 | 2,91,723.2 | 11,66,892.8 |
| 32 | Supply o f earth electrodes (GI) a s p e r Drg no SG/CN/02/13 | Numbers | 30.00 | 1,618.75 | 48,562.5 |
| 33 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 150.00 | 1,707.55 | 2,56,132.5 |
| 34 | "Full Location: Supply and fixing of GI Flat of size 1050x25x3mm as given in enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer of 23set. B) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 125.00 | 1,370.66 | 1,71,332.5 |
| 35 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm a s given i n enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer of 23set. B) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 30.00 | 846.75 | 25,402.5 |
| 36 | Supply of 8-Channel Earth Leakage Detector as per RDSO Specifications RDSO/SPN/256/2002 or latest | Numbers | 1.00 | 1,10,759.06 | 1,10,759.06 |
| 37 | S u p p l y o f 1 6 - C h a n n e l E a r t h Leakage D e t e c t o r a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest | Numbers | 2.00 | 1,70,020 | 3,40,040 |
| 38 | Supply a n d Provision o f H RC Fuse ( base and carrier with 4/6/10/16/20A/32 A fuse as p e r t h e loa d condition a t location boxes, c a b l e h u t s e t c . a s p e r approved circuit diagram. This work also includes painting of particulars of HRC fuse block installed in p o w e r p a n e l i n s t r u c t e d b y Railway representative a t s i t e . ( H R C f u s e block, Fu s e s , w i r e s , C u . l u g s a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor.) | Numbers | 60.00 | 459.97 | 27,598.2 |
| 39 | Supply of Power Panel for IPS Room (using phynolic sheet 1200mm x 1200mm x 10mm and erecting i t u s i n g M S angles 2 5 m m x 25mm x 6mm and fixing of meters, stabilizer and ammeter b y pass switches, H RC fuse blocks, P B T terminals 6 0 m m centre and connecting t h e power equipments t o the power p a n e l a s per approved power diagram, in the power room.) | Numbers | 2.00 | 31,873.7 | 63,747.4 |
| 40 | Supply of Stackable type VRLA batteries 2V, 200Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 120.00 | 4,074.88 | 4,88,985.6 |
| 41 | "Supply, installation and wiring of 230/24V - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR" | Numbers | 2.00 | 12,335.32 | 24,670.64 |
| 42 | Supply of IPS t o suit 6 Line R E station as per RDSO Specifications RDSO/SPN/165 or l a t e s t ( T h i s schedule d o e s n o t include Batteries) As per drawing enclosed | Set | 2.00 | 13,07,398.11 | 26,14,796.22 |
| 43 | Supply of Low maintenance secondary cells o f t h e following capacities w ith necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V- 80AH capacity | Numbers | 228.00 | 3,379.2 | 7,70,457.6 |
| 44 | Supply of Low maintenance secondary cells o f t h e following capacities w ith necessary inspection a s p e r specification/ drawing/ description enclosed in this document.d)Supply of Secondary cells - 2V- 200AH capacity | Numbers | 60.00 | 7,040 | 4,22,400 |
| 45 | Supply of track feed battery charger IRS:S 89-2013 | Numbers | 57.00 | 4,375.25 | 2,49,389.25 |
| 46 | Supply of 'B type choke IRS:S 65-83 | Numbers | 104.00 | 2,855.6 | 2,96,982.4 |
| 47 | S u p p l y , i n s t a l l a t i o n a n d w i r i n g of Transformer rectifier 110VAC/24V D C - 2A capacity a t Power room/ apparatus cases and connecting it to the relevant circuit as per approved circuit diagram using wire PVC 3/0.75mm copper and painting of particulars as per Railway practice. (As per IRS Spec. No. IRS:S 91-2014).[Transformer rectifier 110V AC/24VDC - 2A capacity, wire PVC 3/0.75mm copper and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 3.00 | 9,557.1 | 28,671.3 |
| 48 | S u p p l y o f M o d u l a r Te r m i n a l B l o c k of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 3500.00 | 194.95 | 6,82,325 |
| 49 | Supply of DIN channel for the terminal | Metre | 30.00 | 344.87 | 10,346.1 |
| 50 | Supply of END plates for modular terminal block | Numbers | 80.00 | 36.86 | 2,948.8 |
| 51 | Supply of END clamp for modular terminal block | Numbers | 80.00 | 26.35 | 2,108 |
| 52 | Supply o f operating tool, screw driver and stripper f o r modular terminal. These tools shall b e o f Wago/Phoenix make o r similar and model suitable for the modular terminal supplied | Numbers | 1.00 | 12,246.29 | 12,246.29 |
| 53 | "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" | Numbers | 1.00 | 25,774.2 | 25,774.2 |
| 54 | "Installation o f distilled w a t e r p l a n t with provision o f water supply connection from w a t e r t a p t o w a t e r t a n k , w a t e r t a n k to distilled water plant using G.I Pipes 25mm dia and with regulating valves, provision of separate power supply socket a n d wiring. This work includes fixing of 2 Nos. of rails on the wall a n d grouting a s instructed by Railway representative at site. (Cut rails will be supplied by Railways)." | Numbers | 1.00 | 11,745.65 | 11,745.65 |
| 55 | Installation o f 8-Channel E a r t h Leakage Detector. T h i s includes transportation of materials t o Site location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including c o n n e c t i o n t o t h e B R C e a r t h . Also includescarrying out of pre-commission checklist. | Numbers | 1.00 | 11,320 | 11,320 |
| 56 | Installation o f 16-Channel E a r t h Leakage Detector. T h i s includes transportation of materials t o Site location a n d provision of c a b l e t r o u g h a r r a n g e m e n t s including connection to the BRC earth. Also includes carrying out of pre-commission checklist. | Numbers | 2.00 | 17,586.67 | 35,173.34 |
| 57 | Commissioning of IPS, this schedule includes arrangement o f OEM engineer for checking the Installation and carrying out adjustments of IPS modules and submission of Pre- commissioning checklist | Set | 2.00 | 59,000 | 1,18,000 |
| 58 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This w ork includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This a l s o i n c l u d e s w i r i n g o f all modules, proper earthing of equipments and all other works connected f o r testing and commissioning of the same. Necessary p o w d e r e d c o a t e d A l u m i n i u m ladder a rra n g e m e n t s i n c l u d i n g cable trench, pipes, bolts, a n d o t h e r accessories is included in this schedule.[Earthing i s not covered under this schedule] | Set | 2.00 | 77,160.07 | 1,54,320.14 |
| 59 | Fixing of Modular terminal block/fuse block a l o n g w i t h accessories w i t h provision of fixing holes o n hylam sheet/side angles of Location Box and fixing by Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 3500.00 | 28.97 | 1,01,395 |
| 60 | Supply of 2 4 Fibre armoured OFC cable as p e r R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest | Metre | 6000.00 | 95.23 | 5,71,380 |
| 61 | Supply of 4 8 Fibre armoured OFC cable as p e r R D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest | Metre 36000.00 | — | 126.32 | 45,47,520 |
| 62 | Supply o f Polythene Insulated Polythene Sheathed armoured Jelly Filled Telephone Cable with Poly-AL Moisture Barrier, 10 Pairs, 0.63 MM Conductor Diameter as per RDSOSpecification N o . IRS:TC-41/97 with amendment 1 or latest | Metre | 1000.00 | 123.9 | 1,23,900 |
| 63 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R & M o r A M P o r M o l e x o r K r o n e O r D- LinkMakes | Metre | 600.00 | 34.73 | 20,838 |
| 64 | Supply and provision o f normal joint using Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( Re v. 3 ) w i t h amendment N o . 1 & 2 o r l a t e s t . & j o i n t i n g k i t t o be inspected b y R D S O ) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f j o i n t p i t o f s i z e 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. | Numbers | 30.00 | 4,628.91 | 1,38,867.3 |
| 65 | Supply a n d installation o f 2 4 Fi b r e Joint enclosure for armoured optical fibre cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 4.00 | 13,647.37 | 54,589.48 |
| 66 | Supply a n d installation o f 4 8 fi b r e Joint enclosure for armoured optical fibre cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 16.00 | 20,060 | 3,20,960 |
| 67 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" a s p e r t h e in s tru c tio n s o f Railway representative a t s i t e . ) as per drawing enclosed | Numbers | 750.00 | 262.65 | 1,96,987.5 |
| 68 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & L a y i n g in position c e m e n t concrete of specified proportion i n c l u d i n g c o s t of cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade s t o n e a g g r e g a t e 2 5 m m n o m i n a l size) (Cement, M-Sand, stone jelly of 25mm and a l l other m isc materials required f o r the work should be supplied by Contractor). | cum | 100.00 | 9,361.46 | 9,36,146 |
| 69 | L a y i n g o f STP/OFC/Power C a b l e / switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case caping a n d clamping on t h e wall/Roof tops/ Shelters w i t h suitable clamping a n d hose t o b e provided where e v e r b e n d s / c u r v e s ( P V C conduit/ Case capping and other accessories to be supplied by the contractor) | Metre | 600.00 | 37.3 | 22,380 |
| 70 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included in this schedule) | Metre | 2200.00 | 64.1 | 1,41,020 |
| 71 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included in this schedule.) | Metre | 300.00 | 32.05 | 9,615 |
| 72 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m t o accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it a s p e r t h e in s tru c tio n s of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 100.00 | 314.41 | 31,441 |
| 73 | Breaking o f Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a width o f 0.3 Mtr using cutter machine and removal o f R C C s l a b s o n t h e Passenger Platform, trenching t o a depth o f 0.6m to a c c o m m o d a t e t h e a d d i t i o n a l cables, replacing the slabs removed after the cables are l a i d a n d replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 100.00 | 2,224.44 | 2,22,444 |
| 74 | Excavation of trench along route of existing c a b l e d u c t , o p e n i n g t h e s l a b s to accommodate a d d i t i o n a l c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule.)[Cement,M Sand and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 8000.00 | 161.92 | 12,95,360 |
| 75 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site after laying o f DWC/RCC pipes. During excavation o f trench, i t has t o b e ensured that the excavated soil does not mix with the ballast available. T h e d e p t h o f 1m trench shall be from the bottom of sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 600.00 | 385.45 | 2,31,270 |
| 76 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 60.00 | 501.03 | 30,061.8 |
| 77 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 600.00 | 208.54 | 1,25,124 |
| 78 | Construction of Support for the GI pipes laid in RCC Box type bridges | Numbers | 10.00 | 367.41 | 3,674.1 |
| 79 | Provision of G I pipes 50mm/100mm dia on e x c a v a t e d trenches/platforms/over the ground without abutments and supports | Metre | 50.00 | 118.22 | 5,911 |
| 80 | Fabrication and installation of MS clamps on Girder Bridges for the support of GI pipes laid over the girder bridge | Numbers | 30.00 | 570.26 | 17,107.8 |
| 81 | Provision o f G I pipes (50/100mm d i a ) for cable laying in hard rocky area with off sets a t both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes s h a l l b e c l o s e d w i t h b r i c k masonry abutments work so that no cable is exposed, The work shall be carried o u t as p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 1500.00 | 182.87 | 2,74,305 |
| 82 | L a y i n g o f signaling/power/ telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre 187000.00 | — | 18.18 | 33,99,660 |
| 83 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 2200.00 | 15.4 | 33,880 |
| 84 | "Refilling o f cable trench 0 . 5 m depth by 0 . 3 m w i d t h throughout, w i t h e a r t h after laying of cables, and consolidating the trench by ramming and leveling." | Metre | 300.00 | 7.77 | 2,331 |
| 85 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at a n interval of 2 0 Mtrs. within station limits a n d 5 0 Mtrs. outside station limits throughout the cable r o u t e , diversio ns a n d a l s o a t every track/road crossing." | Numbers | 750.00 | 123.35 | 92,512.5 |
| 86 | Excavation o f cable c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f relay rooms/ AFTC huts, apparatus c a s e s e t c . T h e work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 2 2 0 m m x 1 0 0 m m x 6 0 m m (approximately) shall be supplied by the Contractor]. | cum | 20.00 | 949.05 | 18,981 |
| 87 | Cutting of rock up to a depth of 300 mm and width o f 300mm where rock i s visible from surface, concreting t o ground level after laying cables with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size and curing of concrete t o the required number of days, except in bridges, culverts, level crossings, t r a c k crossings, cable pits, rocky soil including marking of cable alignment, clearing o f debris etc., complete to t h e finished ite m o f w ork as d i r e c t e d by site in-charge. Drg.No.SK/CN/NEW/1. All the material is to be arranged by contractor | Metre | 500.00 | 600.96 | 3,00,480 |
| 88 | Cutting of rock t o a depth o f 200 m m and width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width 3 0 0 m m a b o v e r o c k concreting 200mmx200mm after laying of cable with / cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number o f days, refilling with excavated soil ramming and consolidation except i n bridges, culverts, level crossings, track crossings, cable pits, r o c k y soil including m a r k i n g o f cable alignment, clearing of debris etc., complete to the finished item of work as directed by s i t e in charge. D r g No.SK/CN/NEW/3. All thematerial is to be arranged by contractor | Metre | 250.00 | 314.85 | 78,712.5 |
| 89 | " Ro a d crossing/ Tr a c k Crossing through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm d i a HDPE pipe o r a n y other combination a s d i r e c t e d b y t h e site engineer) ( Supply o f H D P E p i p e i s not covered in this schedule)" | Metre | 250.00 | 1,351.45 | 3,37,862.5 |
| 90 | Cutting/Breaking o f R C C p l a t f o r m or concrete t o a width o f 0.5mtrs 0 . 3 mtrs using cutter machine without damaging the platform. And plastering the removed slabs after laying of cables with proper finishing. (required material should be supplied by the contractor). | Metre | 100.00 | 3,764.41 | 3,76,441 |
| 91 | Blowing/Drawing o f O F C cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test f o r s o l i d lubricated H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre 42000.00 | — | 23.43 | 9,84,060 |
| 92 | Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 27.00 | 10,030 | 2,70,810 |
| 93 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 42.00 | 8,850 | 3,71,700 |
| 94 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 33.00 | 9,233.5 | 3,04,705.5 |
| 95 | Supply o f subsidiary Signal Aspect - Route L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 66.00 | 5,703.33 | 3,76,419.78 |
| 96 | Supply of subsidiary Signal Aspect - Calling o n L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 16.00 | 5,726.13 | 91,618.08 |
| 97 | Supply o f subsidiary Signal Aspect - Shunt L E D a s p e r R D S O Specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 46.00 | 5,740.7 | 2,64,072.2 |
| 98 | Supply o f Multi Lamp Route indicator (LED Double Digit) from 1 t o 9 w ith white LED (With Housing) as per technical specification | Numbers | 4.00 | 64,900 | 2,59,600 |
| 99 | S u p p l y a n d p r o v i s i o n o f Screening arrangement for Signals i n R E area a s per standard practice. T h e w ork comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 S W G G I wires from the screening arrangement up to surface base as per t h e instructions o f Railway representative at site.[All materials required for this work shall be supplied by the Contractor]. | Numbers | 5.00 | 1,880.71 | 9,403.55 |
| 100 | Supply o f Colour light Signal pole 140mm d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 9.00 | 5,841 | 52,569 |
| 101 | Supply o f Colour light Signal pole 140mm d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 31.00 | 4,737.7 | 1,46,868.7 |
| 102 | Supply o f surface base t o suit C L S Signal pole 140mm dia with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 40.00 | 6,814.5 | 2,72,580 |
| 103 | Supply of ladder with platform and shoes to s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. a)Supply of ladder with platform (4.6m) for CLS(Galvanised) | Numbers | 9.00 | 5,698 | 51,282 |
| 104 | Supply of ladder with platform and shoes to s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. b)Supply of ladder with platform (3.6m) for CLS(Galvanised) | Numbers | 31.00 | 5,494.5 | 1,70,329.5 |
| 105 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 10.00 | 5,087.5 | 50,875 |
| 106 | S u p p l y o f G r o u n d t y p e s h u n t s i g n a l - complete w i t h surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 7.00 | 7,463.5 | 52,244.5 |
| 107 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 12.00 | 16,874 | 2,02,488 |
| 108 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 30.00 | 14,278 | 4,28,340 |
| 109 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way | Numbers | 7.00 | 15,121.7 | 1,05,851.9 |
| 110 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Junction type route indicator - 2 way | Numbers | 1.00 | 18,691.2 | 18,691.2 |
| 111 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. d)Supply of Junction type route indicator - 4 way | Numbers | 1.00 | 25,960 | 25,960 |
| 112 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 14.00 | 3,663 | 51,282 |
| 113 | Supply o f Off-set brackets - large/ small made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 14.00 | 3,569.5 | 49,973 |
| 114 | Supply o f Off-set brackets - large/ small made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 13.00 | 2,645.5 | 34,391.5 |
| 115 | Supply of Signal post telephone with facility o f paging a n d talk-back including voice communication equipment w i t h suitable switching arrangement a t t h e Signal post a n d a t S M ' s r o o m a s p e r specification enclosed i n t h i s document. T h i s includes drawl o f tail cable through G I pipe 25mm dia and 2 mtrs long duly clamped to Signal p o s t w i t h b e n d a s r e q u i r e d a t site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. T h e wiring shall be d o n e using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire P V C 16/0.20mm a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d b y the Contractor]. | Numbers | 6.00 | 11,897.35 | 71,384.1 |
| 116 | Manufacture a n d s u p p l y o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 24.00 | 4,945.51 | 1,18,692.24 |
| 117 | Manufacture a n d s u p p l y o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 15.00 | 8,786.26 | 1,31,793.9 |
| 118 | Manufacture a n d s u p p l y o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 30.00 | 11,355.02 | 3,40,650.6 |
| 119 | Supply of relay rack to hold 168 relays, with necessary i n s p e c t i o n , a s per specification/drawing | Numbers | 2.00 | 40,700 | 81,400 |
| 120 | S u p p l y o f p o w d e r c o a t e d F T O T o f 500 capacity | Numbers | 6.00 | 50,593.8 | 3,03,562.8 |
| 121 | Concreting and e r e c t i o n o f cable termination r a c k 500/210/140 Terminals capacity o n teakwood base frame o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in t h e cables a n d painting a s per standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation bolts a n d nuts with washers, cement, sand, s t o n e jelly, teak w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity | Numbers | 6.00 | 13,668.26 | 82,009.56 |
| 122 | Fi x i n g o f P B T terminal b l o c k / P B T fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision o f copper bus b a r for supply terminals, w i r i n g , p r o v i s i o n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w ork also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e b l o c k s i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 2600.00 | 167.99 | 4,36,774 |
| 123 | Fi x i n g o f P B T terminal b l o c k / P B T fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision o f copper bus b a r for supply terminals, w i r i n g , p r o v i s i o n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w ork also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T Fu s e b l o c k s i s not covered in the schedule) [Wire P V C 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic sheet 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 250.00 | 201.27 | 50,317.5 |
| 124 | Concreting a n d erection o f Re l a y racks- 168/56 relay capacity using ' J ' type bolts a n d painting o f r e l a y r a c k a s p e r the instructions of Railway representative at site.(Supply of relay rack i s not covered in this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint and all other miscellaneous materials required for the w o r k s h a l l be supplied b y the Contractor]. b)Concreting and erection of relay rack - 56 capacity | Numbers | 6.00 | 3,015.04 | 18,090.24 |
| 125 | Fixing o f p l u g boards, 5 0 w a y terminal blocks w ith 2 B A terminals, a n d wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth m a t e r ia ls like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g o f contacts f o r data logger and terminating them in tag blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips is n o t covered i n this schedule). [Wire PVC 1 6 / 0 . 2 m m c o p p e r , t a g blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm w i t h decolum finish, MS angles o f size 25mmX25mmX6mm, relay fi x i n g b o l t s and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phynolic sheet 6mm thick of s i z e 1200mmX1800mm with aluminium grooved channel f r a m e f o r relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Per Relay | 150.00 | 1,045.76 | 1,56,864 |
| 126 | Fixing o f additional plug boards, 5 0 ways terminal blocks a n d wiring o f additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations t o Re l a y particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining clips and 5 0 way terminal boards i s n o t covere d i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing r e s i s t o r s a n d condensers, soldering materials, bunching thread, wire wound resistance, c o n d e n s e r , wire supporting tray with cover o f suitable size made o f PVC, paint, varnish a n d a l l other miscellaneousmaterials required f o r the work shall be supplied by the Contractor ] | Per Relay | 20.00 | 726.5 | 14,530 |
| 127 | Carrying o u t alterations t o t h e existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire P V C 16/0.2mm copper. T h e w ork includes p a i n t i n g alterations a n d r e le a s in g the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm c o p p e r , soldering materials, bunching t h r e a d s , condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay | 20.00 | 695.67 | 13,913.4 |
| 128 | Supply o f aspiration type smoke detector. Highly sensitive smoke aspiration system for Monitoring of rooms and equipment's for earliest possible fi r e detection F o r Relay r o o m s a s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 2.00 | 7,08,081.12 | 14,16,162.24 |
| 129 | Supply o f single Loop Analog addressable Fi r e Alarm system w i t h l o o p capacity of connecting maximum 50 devices. The panel shall have a built in power supply and b a t t e r y c h a r g e r R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 2.00 | 3,11,682.08 | 6,23,364.16 |
| 130 | Supply of Multi Sensor detector Dual Optical/ Thermal as per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 55.00 | 16,042.23 | 8,82,322.65 |
| 131 | Supply o f Addressable Single action indoor manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 4.00 | 9,494.38 | 37,977.52 |
| 132 | Supply of Sounder having range of 81 dbA to 92 d b A a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 4.00 | 11,420.51 | 45,682.04 |
| 133 | Supply o f Intelligent addressable Monitor m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 8.00 | 9,494.38 | 75,955.04 |
| 134 | Supply o f Intelligent addressable control m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 8.00 | 9,494.38 | 75,955.04 |
| 135 | S u p p l y o f Auto-dialer f o r S M S alarm generation & routing in case of Fire Alarm to concerned p e r s o n s a s p e r RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 43,931.48 | 43,931.48 |
| 136 | Supply o f 2 c o r e 1.5sq.mm F R L S Copper unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 400.00 | 296.94 | 1,18,776 |
| 137 | S u p p l y o f L H S C a b l e R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 200.00 | 2,246.07 | 4,49,214 |
| 138 | Supply of LHS control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 2.00 | 1,55,660.6 | 3,11,321.2 |
| 139 | Supply and Installation of Air sampling CPVC Pipes with all required accessories for Aspiration system) | Set | 2.00 | 76,137.76 | 1,52,275.52 |
| 140 | Supply of BIS listed semi-automatic stainless steel fi r e extinguisher w i t h UL approved clean gas with auto manual reverse stainless steel valve 'NASA 200 MAR' or similar having capacity of 2kg, and made of stainless steel 304 g r a d e with Indian Railway logo put on each unit. | Per Unit | 8.00 | 24,780 | 1,98,240 |
| 141 | S u p p l y o f Re l a y M o d u l e a s p e r RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 2.00 | 9,867.99 | 19,735.98 |
| 142 | Supply of TCIP Module /Networking card for interfacing t h e Fi r e Alarm a n d Detection systems | Numbers | 2.00 | 30,881.44 | 61,762.88 |
| 143 | Installation, t e s t i n g a n d commissioning charges o f fi r e a l a r m s y s t e m including programming of devices and fire alarm panel | Set | 2.00 | 95,933.57 | 1,91,867.14 |
| 144 | S u p e r v i s i o n , p r o g r a m m i n g , t e s t i n g & C o m m i s s i o n i n g o f A s p i r a t i o n smoke detection | Set | 2.00 | 83,751.53 | 1,67,503.06 |
| 145 | Supply o f Coating Thickness Gauge, with accessories, as per Technical specification | Numbers | 1.00 | 29,500 | 29,500 |
| 146 | Supply of Hydrometer | Numbers | 3.00 | 228.94 | 686.82 |
| 147 | Supply o f G I pipes - 5 0 m m d i a -3.65mm thick as per Technical specification | Metre | 150.00 | 457.88 | 68,682 |
| 148 | Supply o f G I p i p e s - 1 0 0 m m dia-4.5mm thick as per Technical specification | Metre | 6500.00 | 1,119.16 | 72,74,540 |
| 149 | Supply o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s per specification N o . I S 4984: 2016 with latest amendments and Material Grade:PE 80 | Metre | 300.00 | 853.55 | 2,56,065 |
| 150 | Supply a n d laying o f P V C Warning Tape colour Orange, width o f 250mm (10") by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 2500.00 | 46.15 | 1,15,375 |
| 151 | Supply of Electronic Cable Route Marker 3M m ak e o r similar, Model: R FID (1421) and installation, cable detection o f capacity to detect the cable upto 5 feet depth. | Numbers | 800.00 | 2,441.72 | 19,53,376 |
| 152 | Supply o f HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre 42000.00 | — | 60.93 | 25,59,060 |
| 153 | S u p p l y a n d Installation o f Wall/Rack mountable 2 4 Fibre management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE m ak e o r better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length (All other materials required for splicing are to be supplied by contractor ) | Numbers | 4.00 | 18,686.74 | 74,746.96 |
| 154 | S u p p l y a n d Installation o f Wall/Rack mountable 4 8 Fibre management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE m ak e o r better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos of Patch cords of required l e n g t h (All other materials required for splicing are to be supplied by contractor) | Numbers | 12.00 | 32,885.01 | 3,94,620.12 |
| 155 | S u p p l y a n d Installation o f surfa c e Wall mountable type 19 inch 12U network Rack w ith front glass d o o r w i t h l o c k a n d rack fi x i n g multipoint A C P o w e r t r i p & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) | Numbers | 2.00 | 6,761.51 | 13,523.02 |
| 156 | Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories | Numbers | 2.00 | 65,734.12 | 1,31,468.24 |
| 157 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 260.00 | 1,622.5 | 4,21,850 |
| 158 | Supply of Track Feed Resistance | Numbers | 57.00 | 287.77 | 16,402.89 |
| 159 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers 18000.00 | — | 61.44 | 11,05,920 |
| 160 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 4100.00 | 93.02 | 3,81,382 |
| 161 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 1500.00 | 103.84 | 1,55,760 |
| 162 | Supply o f 4 wire DTMF based w a y station e q u i p m e n t c o m p l e t e a s p e r RDSO specification No.IRS.TC@45<47@93 a n d 4 wire control telephone with audio visual indication and r e s e t b u t t o n fi t t e d on telephone conforming to specification No.IRS-TC@45&47@97 or latest. | Set | 1.00 | 9,086 | 9,086 |
| 163 | Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool b o x made o f 25mm teak w oo d plank, perspex sheet, a l l t h e tools m e n t i o n e d a b o v e , p a d l o c k a n d other miscellaneous items shall be supplied by the Contractor]. | Set | 1.00 | 29,185.6 | 29,185.6 |
| 164 | Supply a n d installation o f teakwood glass fronted b o x o f s i z e 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall b e supplied by the Contractor]. | Numbers | 5.00 | 7,505.45 | 37,527.25 |
| 165 | "Supply and provision of Rubber mat of not less than 6mm thick and with an insulation t o withstand 650VAC, o n the floor o f relay room etc a t places a s indicated b y railway representative at site." | Square Foot | 100.00 | 144.86 | 14,486 |
| 166 | Installation of combined type point machine-IRS type and connecting all ground connections including wiring and termination in p o i n t m a c h i n e and interconnections between point machine and CT box through PVC hose p i p e with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw b a r lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire P V C 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied by the Contractor]. | Numbers | 26.00 | 16,383.88 | 4,25,980.88 |
| 167 | Painting o f existing colour light Signals as p e r standard practice. T h e w o r k involves scraping of old paint, applying one coat of R e d oxide a n d t w o c o a t s o f Aluminium/ enamel paint o n the Signals - complete as instructed by Railway representative at site.[Aluminium p a i n t , red-oxide a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 5.00 | 2,442 | 12,210 |
| 168 | Filling earth around location boxes/signal foundations for a width of 0.5m on all sides, up t o a l e v e l 1 5 0 m m b e l o w the foundation top. T h i s w o r k includes consolidation of earth by watering and ramming.The e a r t h s h a l l b e t a k e n from Railway premises as instructed by Railway representative at site. | cum | 5.00 | 231.3 | 1,156.5 |
| 169 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection o f colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 40.00 | 9,213.28 | 3,68,531.2 |
| 170 | "Erection o f s u r f a c e b a s e , s i g n a l pole, mounting o f colour l i g h t signal u p t o 4 aspects complete o n Signal pole/ Off-set bracket, ( f o r L E D / filam e nt b u l b s ) with lenses, triple p o l e l a m p holder, filament switching units, C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h p l a t f o r m c o m p l e t e and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d wherever necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3 / 0 . 7 5 m m copper, provision of EWS locks, and painting of one c o a t o f r e d o x i d e a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t s h a l l be provided by drilling a hole in the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, c u r r e n t regulators, l a m p holders, lamps, filam e nt switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, s t o n e jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints P V C / N y l o n sleeves, enameled number p l a t e s . enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 40.00 | 8,287.08 | 3,31,483.2 |
| 171 | "Excavation o f p i t a n d casting concrete foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of g r o u n d t y p e c o l o u r l i g h t s h u n t signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm a n d all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 7.00 | 4,645.17 | 32,516.19 |
| 172 | "Erection o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED a s p e c t s / l e n s e s , b u l b s with holders (whichever i s applicable), fixing of lens guards, number plate, termination of tail cables, wiring o f signal unit w ith PVC wire 3/0.75mm copper, provision o f EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. ( S u p p l y o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n t h i s schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall b e supplied by the Contractor]." | Numbers | 7.00 | 3,170.44 | 22,193.08 |
| 173 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Post type shunt Signals, termination o f tail cables and wiring using w i r e P V C 3/0.75mm copper, provision of EWS lock and painting o f one coat o f red- "oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n the CLS post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 10.00 | 2,306.03 | 23,060.3 |
| 174 | Fi x i n g a n d w i r i n g o f M u l t i l a m p route indicator[Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, PVC/Nylon sleeves, paints and a l l other miscellaneous materials shall be supplied by the Contractor] | Numbers | 3.00 | 4,507.99 | 13,523.97 |
| 175 | Fixing o f junction type route indicators - 1 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Route Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing and wiring o f direction type route indicator - 1 way | Numbers | 7.00 | 2,238.04 | 15,666.28 |
| 176 | Fixing o f junction type route indicators - 1 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Route Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].b)Fixing and wiring o f direction type route indicator - 2 way | Numbers | 1.00 | 2,460.04 | 2,460.04 |
| 177 | Fixing o f junction type route indicators - 1 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Route Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. d)Fixing and wiring o f direction type route indicator - 4 way | Numbers | 1.00 | 4,363.69 | 4,363.69 |
| 178 | Fixing of Offset brackets using 'U' bolts and n u t s , erection o f Calling O n Signals/ 'A' marker lights, termination of tail cables and wiring using w i r e P V C 3/0.75mm copper, provision o f E W S l o c k , n u m b e r plates/ marker boards and painting. The work also includes drilling suitable holes o n t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply o f Calling o n Signal/ ' A ' marker light, L E D aspects/holders & bulbs and Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through bolts with nut, wire PVC 3/0.75mm copper, E W S lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints a n d all other miscellaneous materials shall be supplied by the contractor]. | Numbers | 14.00 | 2,081.25 | 29,137.5 |
| 179 | Excavation of pit in and around the existing s i g n a l s v e r y c a r e f u lly w i t h o u t causing damage to the working cables and shifting t h e S i g n a l s a l o n g w i t h t h e concrete foundations f o r approximately 1 m t o a n e a r b y p o s i t i o n s o a s t o c l e a r the infringement from the nearest track centre a s instructed b y Railway representative at s i t e . T h e e x i s t i n g c a b l e c o i l s s h a l l be released carefully s o a s t o give access for shifting. Necessary masonry work and earth work shall be carried out in and around the signals after s h i f t i n g a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. | Numbers | 4.00 | 4,793.81 | 19,175.24 |
| 180 | "Removal of existing CLS units, fixing of new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision o f E W S locks wherever necessary, termination o f tail cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through t h e signal p o l e s a n d the unwanted cables duly released" | Numbers | 4.00 | 10,296.64 | 41,186.56 |
| 181 | Excavation o f p i t a n d construction of m a s o n r y platform a s p e r d r a w i n g No. SG/CN/02/12 w i t h country bricks o f size 220mmx 100mmx60mm (app) a t t h e foot o f s i g n a l p o s t telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required for the work shall b e supplied by the Contractor]. | Numbers | 6.00 | 5,355.94 | 32,135.64 |
| 182 | Painting o f existing boards l i k e LEGEND boards, warning boards, STOP boards etc., a s p e r standard practice a n d a s p e r the instructions of Railway representative at site.(Supply of boards is not included in this schedule).[Paint and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 6.00 | 1,262.63 | 7,575.78 |
| 183 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 22.00 | 8,914.5 | 1,96,119 |
| 184 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 30.00 | 7,145.44 | 2,14,363.2 |
| 185 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 4.00 | 4,234.65 | 16,938.6 |
| 186 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable b)Alteration t o existing t r a c k circuits at relay end | Numbers | 4.00 | 3,850.31 | 15,401.24 |
| 187 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation and erection o f apparatus case f u l l s i z e a s p e r D r g . No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door a n d another f o r t h e back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 125.00 | 11,333.1 | 14,16,637.5 |
| 188 | " E x c a v a t i o n o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' type l o c k f o r t h e front d o o r and latching arrangement for the back door, and fixing o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]""" | Numbers | 30.00 | 8,787.04 | 2,63,611.2 |
| 189 | Excavatio n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r c a b l e throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints.(Supply of CT boxes is not covered i n this schedule. Rails o f different length shall be supplied b y Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly of size 20/25mm, p a i n t , varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for eac h pipe, fixing bolts a n d nuts with washers, E W S locks, paints a n d all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 5.00 | 4,999.16 | 24,995.8 |
| 190 | Excavation of pit in and around the existing l o c a t i o n b o x e s v e r y c a r e f u l l y without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement a s instructed b y the Railway representative a t site. T h e work includes ensuring the safety of the signaling system, releasing the cable coils t o g i v e a c c e s s for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 5.00 | 5,348.81 | 26,744.05 |
| 191 | Excavation of pit in and around the existing l o c a t i o n b o x e s v e r y c a r e f u l l y without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement a s instructed b y the Railway representative a t site. T h e work includes ensuring the safety of the signaling system, releasing the cable coils t o g i v e a c c e s s for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 5.00 | 3,545.06 | 17,725.3 |
| 192 | Termination of new main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / batte ry b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars are to be r e p a in t e d /corrected o n t h e d o o r s of apparatus c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w ith cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, brick s, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 100.00 | 73.59 | 7,359 |
| 193 | Termination o f m a i n , t a i l , Signaling and p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." a)Termination on 25/60mm P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit 19450.00 | — | 172.14 | 33,48,123 |
| 194 | Termination o f m a i n , t a i l , Signaling and p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." b)Termination o n PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 1230.00 | 209.93 | 2,58,213.9 |
| 195 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base level and the bottom surface shall be sealed w i t h sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 50.00 | 151.09 | 7,554.5 |
| 196 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base level and the bottom surface shall be sealed w i t h sealing compound. b)Termination of cables on PBT fuse block (existing location) (Per Unit = Per Fuse block) | Per Unit | 20.00 | 188.86 | 3,777.2 |
| 197 | "Painting of existing apparatus case (Outside) - Full size" | Numbers | 5.00 | 1,182.15 | 5,910.75 |
| 198 | Painting o f existing apparatus case (Inside and Outside) - Half size | Numbers | 5.00 | 2,263.01 | 11,315.05 |
| 199 | Charging and installation of secondary cells o f t h e following capacities, o n existing battery stand/ R C C s l a b s i n t h e battery r o o m . T h e w o r k i n v o l v e s c h a r g i n g of secondary cells, fixing a n d connecting the batteries with strips, manufacture and fixing of t e a k w o o d t e r m i n a l box, termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e relay room. The particulars shall be digitally using good quality "laminated gum sheet, provision of hydrometer - 1 No. o n a stand and battery tester-1 N o . Charging o f secondary cells shall b e d o n e b y t h e contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [ Te a k w o o d p l a n k 2 5 m m t h i c k for manufacturing termination box with locking facility, wire P V C 7/1.4mm a n d 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, a n d a l l other miscellaneous materials required f o r t h i s w o r k shall be supplied by the contractor]." b)Installation o f 2 V- 2 0 0 A H c e l l o n existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 60.00 | 869.41 | 52,164.6 |
| 200 | Provision of signaling arrangement during Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station | 1.00 | 33,631.06 | 33,631.06 |
| 201 | Provision o f P A s y s t e m a n d Magneto telephone communication at stations/ tents a s p e r t h e in s tru c tio n s o f Railway representative a t site. T h e P A system and magneto telephones will be returned to the contractor a f t e r t h e completion o f NI working. Signalling cables available may be used for the communication.(Hiring o f PA s y s t e m e q u i p m e n t s and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied b y the Contractor]. (Per Unit= Per set per day) | Per Unit | 5.00 | 1,637.25 | 8,186.25 |
| 202 | Installation a n d w i r i n g o f existing Way s t a t i o n e q u i p m e n t D T M F a n d control telephones. T h e w o r k involves fixing the released way station equipment on the wall at an appropriate place in consultation with Railway representative a t site, wiring and interconnecting t h e same with test panel, control telephones and batteries.(Supply of way station equipment, control telephones a n d batteries i s n o t i n c l u d e d in this schedule). [Wire PVC 3/0.75mm & 16/0.2mm copper, MS clamps f o r fixing arrangements, PVC tubes 25mm dia for interconnections and all other miscellaneous items required f o r the work shall be supplied by the Contractor]. | Numbers | 1.00 | 8,016.98 | 8,016.98 |
| 203 | Installation o f magneto telephones with Nicad pack | Numbers | 16.00 | 3,322.6 | 53,161.6 |
| 204 | Installation o f L C c o n t r o l p a n e l cum i l l u m i n a t e d diagram board at Level Crossing gate lodge a n d wiring t h e same including interconnections and painting. (Supply of LC control panel cum illuminated diagram board is not included in this schedule). [Wire PVC 16/0.2mm copper, soldering materials,LEDs, resistances and a l l other required miscellaneous materials shall be supplied by the Contractor.]. | Numbers | 2.00 | 6,359.19 | 12,718.38 |
| 205 | Casting concrete foundation of size 900mmX 900mmX900mm for pedestal, 400mmX400mmX 600mm for meeting post, fixing of lifting barrier boom, contact makers, termination of cables, wiring and painting as per the instructions of Railway representative at site. (Supply of pedestals, meeting posts, contact maker, electric lifting barriers, rail posts, cranks and 'A' type foundation is not covered in this schedule). [Concreting materials, bolts and nuts, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Unit | 6.00 | 20,297.74 | 1,21,786.44 |
| 206 | Fixing and wiring o f Two Nos. o f Electronic G a t e Warning equipment f o r e a c h level crossing gate, o n e o n eac h roa d warning signal, amplifier in the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting.(Electronic G a t e Warning Equipment and amplifier will be supplied by Railways).[All wiring, fixing and painting materials shall be supplied by Contractor]. | Set | 3.00 | 4,491.34 | 13,474.02 |
| 207 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 6.00 | 3,972.14 | 23,832.84 |
| 208 | Painting, erection and concreting o f Goods warning boards on rails as per the Signalling plan. T h e w o r k includes manufacturing of clamps a n d fi x i n g the b o a r d t o t h e rails, supply and fixing of scotch lite reflectors and concreting the rail post to a size of 600mm x 600mmx900mm. (Supply o f goods warning boards a r e not covered i n this schedule. Rails o f different lengths will be supplied by Railways and the Contractor h a s t o c u t t h e m t o the required lengths).[Stone j e l l y o f size 20/25mm dia , M sand, cement, M.S.flats, scotch lite strips (14 Nos) for each board, fixing bolts a n d nuts, paint and a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 4.00 | 5,398.39 | 21,593.56 |
| 209 | Provision of HDPE Pipe of dia 40/33 mm | Metre 42000.00 | — | 26.11 | 10,96,620 |
| 210 | Laying o f DWC/Split D W C Pipes f o r Track Crossing/Road Cutting/Trenches | Metre | 4002.00 | 42.46 | 1,69,924.92 |
| 211 | "Releasing o f existing relay racks/ cable termination r a c k s a l o n g w i t h a l l the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, c a b l e s etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative a t site. After releasing, the fl o o r s h a l l b e l e v e l l e d and cement plastered" | Rack | 20.00 | 1,977.19 | 39,543.8 |
| 212 | Releasing o f existing Route Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 2.00 | 1,541.51 | 3,083.02 |
| 213 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and s t a c k i n g them neatly a t a p l a c e as instructed b y Railway representative at site. Also the resultant pits shall b e re- surfaced and consolidating by ramming and levelling" | Numbers | 2.00 | 1,580.36 | 3,160.72 |
| 214 | Removal o f obstructing sleepers, a n d rails available in the path of cable trench (Above the ground) | Numbers | 20.00 | 235.47 | 4,709.4 |
| 215 | Removal o f obstructing sleepers, a n d rails available in the path of cable trench (buried inside ground) | Numbers | 20.00 | 3,205.7 | 64,114 |
| 216 | Jungle cutting along with the cable route | Metre | 500.00 | 5.84 | 2,920 |
| 217 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stack e d a t a p l a c e as instructed by Railway representative at site. | Numbers | 80.00 | 3,006.71 | 2,40,536.8 |
| 218 | Breaking o f concrete a n d releasing the existing c a b l e termination b o x e s , after releasing the base plank, Terminal blocks, Fu s e Blocks, Terminal Boards, c u t rails, pipes, etc., closing t h e resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 25.00 | 2,004.94 | 50,123.5 |
| 219 | Releasing o f existing S M ' s control panel including b a s e plank, a n d other gadgets connected very carefully without causing any damage t o the panel, accounting and stacking them neatly at a place as instructed by R ailw a y representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered | Set | 1.00 | 5,257.24 | 5,257.24 |
| 220 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling. | Numbers | 15.00 | 3,083.03 | 46,245.45 |
| 221 | Dismantling and releasing o f existing Point m a c h i n e s ( a l l t y p e s ) in c lu d in g ground connections and other accessories available complete w i t h o u t a n y d a m a g e t o the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. | Numbers | 24.00 | 2,698.69 | 64,768.56 |
| 222 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set | 3.00 | 5,550 | 16,650 |
| 223 | Releasing o f Secondary cells a n d battery stands available in the battery room along with connecting strips, wires a n d terminal boxes carefully without causing any damage to t h e batteries, accounting and stacking them n e a t l y a t a p l a c e as instructed by Railway representative at site. After releasing any holes i n the walls/ flooring shall b e filled with cement mortar and plastered. | Set | 1.00 | 5,395.99 | 5,395.99 |
| 224 | Releasing of existing Block Instruments (all types), B l o c k counters, batteries, block filter, block bell equipment etc., carefully w i t h o u t a n y d a m a g e , accounting and stacking them neatly at a place as instructed by Railway representative at site | Numbers | 3.00 | 1,773.23 | 5,319.69 |
| 225 | Releasing o f a l l t h e S & T gadgets a t LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency k e y box , etc a n d concerned w i r i n g , accounting and stacking them neatly at a place as instructed by R ailw a y representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. | Set | 3.00 | 9,557.1 | 28,671.3 |
| 226 | "Releasing o f existing ground t y p e shunt signals along with surface base, signal post e t c c a r e f u l l y w i t h o u t a n y damage, accounting and stacking them neatly a t a p l a c e a s instructed b y Railway representative a t s i t e . T h e w o r k also includes breaking and removal o f concrete foundation and refilling o f the resultant pit by ramming and levelling." | Numbers | 5.00 | 2,196.41 | 10,982.05 |
| 227 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 50.00 | 159.29 | 7,964.5 |
| 228 | Releasing of all power equipments including equipment s t a n d s , terminal boards, power panel e t c . , i n t h e power room carefully without causing any damage t o the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked a t a place as instructed by Railway representative at site. After releasing a n y h o l e s i n the walls/flooring shall b e fi l l e d w i t h cement mortar and plastered. | Set | 1.00 | 12,640.13 | 12,640.13 |
| 229 | Releasing o f existing control equipments - c o m p l e t e including way station equipments, telephones, power supply for w a y station equipment a n d telephones, a l o n g w i t h all wiring, accounting and stacking them neatly at a p l a c e as instructed b y Railway representative at site. | Set | 2.00 | 6,012.04 | 12,024.08 |
| 230 | Survey o f Cable Route a n d Preparation of Cable Route Plan | Kilometre | 8.00 | 716.01 | 5,728.08 |
| 231 | Provision of one skilled and 2 unskilled staff r o u n d t h e c l o c k t o a t t e n d t h e teething trouble of the installation along with SSE/JE after the installation has been brought into commissioning. T h e w ork includes routine maintenance, failure restoration as per the direction of the SSE/JE | Month | 1.00 | 73,903.01 | 73,903.01 |
| 232 | Videography of cable Route | Kilometre | 16.00 | 519.85 | 8,317.6 |
| 233 | Protection adjustments a n d re-instating of S & T gears by deputation of Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 350.00 | 847.59 | 2,96,656.5 |
| 234 | Protection, adjustment a n d reinstating of S & T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer ( S k i l l e d Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination o f cables, minor patch work on damages at location box, Plastering, Concreting b r i c k work, wiring alterations, cable jointing etc a s per instruction of Railway representatives at size. | Man- Days | 200.00 | 1,073.45 | 2,14,690 |
| 235 | Transportation o f Signalling materials by r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes l o a d i n g a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 8000.00 | 22.75 | 1,82,000 |
| 236 | Transportation of Signalling materials more than 100km | MT-Km 20000.00 | — | 13.91 | 2,78,200 |
| 237 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., w i t h a l l leads a n d l i f t s etc., complete and a s p e r t h e instruction of Railway representative at site. | Hour | 50.00 | 1,202.5 | 60,125 |
| Schedule total | ₹6,67,92,657.54 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnxVclarification140520246.pdf
ATTACHMENT
cablecutpenaltyletter4.pdf
ATTACHMENT
GCCApril20226.pdf
ATTACHMENT
GCCcorrectionsslips_compressed.pdf
ATTACHMENT
Policeverificationletter5.pdf
ATTACHMENT
TVC-TVCS-2VolumeIPartII.pdf
ATTACHMENT
TVC-TVCS-3Volume_II_Ch_I__.pdf
ATTACHMENT
TVC-TVCS-4VolumeIICh-IIPVC.pdf
ATTACHMENT
TVC-TVCSStage_IIFinalApprovedSIP.pdf
ATTACHMENT
TVC-TVCS_5_Volume_II_Ch_III_S_compressed.pdf
ATTACHMENT
TVC-TVCS__6_Volume_II_Ch_IV_Technical_conditions.pdf
ATTACHMENT
TVC-TVCS-1VolumeIPartI_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .