Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80,852.09Accepted-AOC THRISSUR KERALA | THRISSUR | KERALA | 679105 | L1 | Accepted-AOC Accepted Vide Resolution of Kolazhy gp | |
| 2 | L2₹85,852.09+₹5,000 (6.18%)Rejected-AOC | L2 | Rejected-AOC higher value |
Tender Value
₹81,353
EMD Value
₹2,034
Closing Date
4 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NEETHU GOPAL
KOLAZHY GRAMAPANCHAYAT, THIROOR , MGKAVU, 680581, 0487-2200271
Kuzhingara Drinking water project maintenanace wrad 3 pro no 266/24
2023_LSGD_614805_11
06_AE_LSGD_KGP_2023
Open Tender
Civil Works - Roads
Item Rate
180 days
KOLAZHY GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹2,034
Yes
3 Aug 2025
25 Oct 2023
6 Nov 2023
25 Oct 2023
4 Nov 2023
25 Oct 2023
Amount
electrical
OD214950/2023-2024:Supply of 3 phase, 3 hp/2.2 KW bore well submersible motor pump set (100 mm) capable to minimum discharge range of 6800 LPH to 3000 LPH at head range of 40 to 92 meters, 40 mm (1.5 inch) delivery, 415 V, 50 Hz, AC supply. (Makes preferred :- Deccan-ERS45/21, ER43/18, KS4D 4021 Kirloskar /Texmo or equivalent approved make)
OD214232/2023-2024:Supply and providing three phase submersible pump controller with ammeter, voltmeter, push button, indicators, contactor and O/L relay and additional dry run protector (iAD) etc suitable for 3 HP submersible bore well pump. ( L&T, MU-G6 DOL or equivalent make)
90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors.
OD214233/2023-2024:Supply and providing 40 mm size bottom and top adapter set for column pipe of submersible pump as required.
OD214234/2023-2024:Supply and providing 40 mm (1.5") size, standard duty (Red) column pipe of 3 mtr length, for bore well submersible pump as required.
OD215053/2023-2024:Supply of silicon/ rubber C-ring (washer) suitable for 1.5 inch column pipe as required.
OD214235/2023-2024:Supply, threading and providing 50 mm dia medium class G.I. pipe in position with accessories like coupling, x-nipple, reducer etc. for extending as required.
OD214236/2023-2024:Supply and providing 50 mm size screwed end type Gunmetal horizontal Non-return valve in position as required.
OD214237/2023-2024:Supply and providing 50 mm size medium class G.I. bend in position with accessories as required
OD214238/2023-2024:Supply and providing 50 mm size heavy duty GI Union coupling in position as required.
OD214239/2023-2024:Supply and providing 50 mm x 15 mm size medium class G.I. Tee in position with accessories as required
OD214240/2023-2024:Supply and providing industrial type pressure gauge with gun metal / brass vales in position as required.
OD214241/2023-2024:Supply and providing 14 mm size nylon marine rope (white/green) for hanging the pump set in well, tying with an out side object as required.
OD214242/2023-2024:Labour charges for conveyance fixing, lowering and erection of submersible motor pump set in bore well with power cable connections, delivery pipe, nylon rope, trial run etc as required.
OD214243/2023-2024:Supply and providing 4 pole enclosure for independent mounting of MCB/RCCB/Isolator etc. as required.
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD214244/2023-2024:Supply and providing Test joint for earthing made up of 2 nos, 25x5 mm GI strip, 25 cm long placed on either sides of earth leads and watering pipe, bending, drilling and tightening with 4 sets of brass/SS nut, bolt, washer etc as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD214245/2023-2024:Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required.
OD214246/2023-2024:Supply and providing the following size of bolt & nut with washers on the existing MS boxes/ earth bus etc as required including drilling necessary holes as required. 12x3mm brass nut & bolt.
OD217521/2023-2024:Supply and fixing 63A backelite HRC Fuse unit with HRC fuse link in the existing meter board and giving connections as required.
OD214248/2023-2024:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required. (including cost of HRC fuse links in case of SDF/ SDFCO),32 A, 415 V, 50 Hz, AC 23 A duty, TPN switch disconnector unit with fuses
OD214249/2023-2024:Labour charges for dismantling all the existing connections, and pipe line, Lifting the faulty motor pump set from bore well by dismantling the column pipe one by one, with out damages, checking the connections and insulation resistance for fault finding etc as required, conveying the dismantled materials to scrap store etc as required.
SRISAKTHI ELECTRICALS
Bidder Name
SRISAKTHI ELECTRICALS
SURESH K S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_922576.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .