Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
28 Sept 2026, 5:00 pm
DGM(CnP)
Uri-II Power Station,Uri,Baramulla,JK
Construction of 05 no. bunkers in residential cum office complex of Uri-II Power Station, JK.
2026_NHPC_925094_1
NH/Uri-II/CnP/26-27/185
Open Tender
Civil Works
Works
365 days
Uri-II Power Station, Nowpora, Uri, JK
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
NHPC Limited
₹2.8 L
Yes
8 Sept 2026
8 Sept 2026
8 Oct 2026
8 Sept 2026
28 Sept 2026
8 Sept 2026
8 Sept 2026 - 17 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. dispose earth to be levelled and neatly dressed. All kinds of soil. | 1,209.87 | Cum | 205.57 | ₹2,48,712.98 |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. dispose earth to be levelled and neatly dressed. Hard Rock (Blasting Prohibited). | 518.51 | Cum | 1,238.83 | ₹6,42,345.74 |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. | 736.47 | Cum | 239.69 | ₹1,76,524.49 |
| 4 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. | 33.3 | Cum | 1,321.98 | ₹44,021.93 |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | 117.26 | Cum | 8,372.35 | ₹9,81,741.76 |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works upto plinth level. | 304.55 | Cum | 9,851.27 | ₹30,00,204.28 |
| 7 | Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC.
(Note:- Cement content considered in M-30 is @ 340 kg/cum). | 304.55 | Cum | 108.44 | ₹33,025.4 |
| 8 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein. | 182.73 | Quintal | 1,032.77 | ₹1,88,718.06 |
| 9 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. | 1,005.02 | Kg | 363.23 | ₹3,65,053.41 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more. | 33,500.5 | Kg | 135.94 | ₹45,54,057.97 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
TenderDocument.pdf
Tender Documents • 9.95 MB
SafetyManual.pdf
Additional Documents • 0.73 MB
BOQ_972203.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .