Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹5.8 L+₹80,559 (16.1%)Rejected-AOC PITHORAGARH PIN 900 336 C O 56 APO | 900336 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹5.9 L+₹86,395 (17.3%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹6.3 L+₹1.3 L (26.4%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹7.2 L+₹2.2 L (43.2%)Rejected-AOC | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
7 Jun 2023, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PETTY REPAIR/REWIRING OF INTERNAL ELECTRIC SUPPLY OF BUILDINGS INCLUDING SUBMAIN, DB AND ALLIED MAINT WORKS AT ITM MUSSOORIE UNDER GE (I) RND DEHRADUN
2023_MES_596055_1
GE(I)RND/9236/E8/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹16,000
Yes
17 Jun 2023
17 May 2023
9 Jun 2023
17 May 2023
7 Jun 2023
24 May 2023
17 May 2023 - 24 May 2023
Amount
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as per existing finishes complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch. Make of cable: Gloster/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
All as per Srl item No 2 here in before but for point wiring for one light point controlled by two Nos two way switch complete all as specified and directed.
All as per Srl item No 2 here in before but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent omplete all as specified and directed.
All as per Srl item No 2 here in before but point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 2 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per item No 2 here in before for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed. Note for item 1 to 7 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia Medium grade (v) Make of cable : Gloster/Polycab/L&T (vi) Make of PVC conduit & fittings : AKG / /Plaza/Jindal /Avon/Finolex/ Polycab /Kalinga.
S&F Modular switch single pole one way 6 amp complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F Modular switch single pole one way 16 amp complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F Modular switch , 6 amp, single pole, two way complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F Modular bell push, 6 amp 240 volts complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F door bell, AC, 240 volts, single pole complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete all as specified and directed. Make - Legrand(Wood)/ Anchor(PENTA)/ Crabtree(Havells)
S&F ceiling rose 3 plates polycarbonate, isolated body complete all as specified and directed. Make - Legrand/Anchor/Havells
S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings suitable for one number LED lamp complete all as specified and directed. Make of holder - Legrand / Anchor / Havells.
S&F in replacement of UNSV Compact commercial batten with universal batten fitting suitable for single T8 LED tube complete all as specified and directed. Make:Crompton / Philips/ Havells
S&F in replacement of UNSV fluorescent tube light with LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% complete all as specified and directed. Make : Crompton/Philips/Havells.
S&F in replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as specified and directed. Make : Crompton/Philips/Havells.
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as specified and directed. Make : Crompton/ Philips/Havells.
S&F in replacement of UNSV Decorative, Wall mounting champagne gold finish fixture with plastic body along with 9 W LED lamp B22 base complete all as specified and directed. Make : Crompton/Philips/ Havells. Note: The cost of LED Bulbs are not included in this item.
Supplying, fixing & testing in replacement UNSV recess mounting in built ,24 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- Crompton/Phillips/Havells.
S&F in replacement of UNSV SPN plug and socket enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet complete all as specified and directed Make of SPN DB - Legrand/L&T/C&S as approved by GE.
S&F in replacement UNSV TPN plug and socket enclosure with triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet complete all as specified and directed Make of SPN DB - Legrand/L&T/C&S/Indoasian. as approved by GE.
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2x6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x 6 Sqmm as earth continuity conductor complete all as specified and directed. Make of cable : Gloster/Polycab/L&T & Make of PVC conduit & fittings : AKG / /Plaza/Jindal /Avon/Finolex/Polycab /Kalinga as approved by GE. Notes for item No. 25 (i) Two the run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface / finishes The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs.
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2 x10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed. Make of cable : Gloster/Polycab/L&T Make of PVC conduit & fittings : AKG / /Plaza/Jindal /Avon/Finolex/Polycab /Kalinga as approved by GE. Notes for item No. 26 (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface/ finishs. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs.
M&L in replacement of UNSV sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 4x10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed. Make of cable : Gloster/Polycab/L&T Make of PVC conduit & fittings : AKG / /Plaza/Jindal /Avon/Finolex/Polycab /Kalinga as approved by GE.. Notes for item No. 27 (i) Four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface/ finishs. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs.
S&F in replacement of UNSV VTPN DB with vertical type load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 Amp MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed Make :-Legrand/ Havells/C&S/Indo Asian.
S&F in replacement of unsv MCB distribution board SPN, 240 volts, 4 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’/BOQ. Make: Legrand/ Havells/ C&S /Indoasian as approved by GE.
All as per item No 29 above but SPN, 240 volts, 8 ways complete all as specified and directed Make: Legrand/ Havells/ C&S/Indoasian as approved by GE.
All as per item No 29 above but SPN, 240 volts, 12 ways complete all as specified and directed by GE Make: Legrand/ Havells/ C&S/Indoasian.
Supply and fix in replacement of unsv MCCB with MCCB 4 pole,200 Amps 415 volts, 50 Hz, lcs=100% lcu, option for inbuilt or add on module for earth leakage protection, thermal and magnetic adjustable having breaking capacity 25 KA , with thermal magnetic protection unit and testing on existing panel complete,all as specified and directed. Make: Legrand/L&T/ C&S /Indoasian as approved by GE.
All as per item No 32 above but, MCCB 4 pole ,160 Amps on existing panel complete, all as specified and directed. Make: Legrand/L&T/ C&S /Indoasian as approved by GE.
All as per item No 32 above but MCCB 4 pole,125 Amps on existing panel complete, all as specified and directed. Make: Legrand/L&T/ C&S /Indoasian as approved by GE.
S & F in replacement of unsv MCB SPN with MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 6 to 32 Amps complete all as specified and directed. Make: Legrand/L&T/ C&S /Indoasian as approved by GE.
S & F in replacement of unsv MCB SP with MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified and directed. Make: Legrand/L&T/ C&S /Indoasian as approved by GE.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all necessary excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed NOTE : RCC pit cover shall be provided as pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
S&F as in replacement of UNSV rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of size 25 mm dia complete, all as specified and directe.
S&F as in replacement of switch socket combination 2 in 1, 3 pin, 5 and 15 Amp universal flush type 6/16 Amps with box (2 hole complete with suitable connection with 2x2.5sqmm and 1x2.5sqmm single core cable length upto 01 mtr . Make - Legrand/ Anchor/ Havells as approved by GE.
S & F as in replacement of unsv switch piano single pole flush type 6 amps, 230 volts complete,all as specified and as directed Make - Legrand/ Anchor/ Havells as approved by GE.
S&F as in replacement of unsv socket out let 3 pin 6 Amps flush type complete, all as specified and directed. Make - Legrand/ Anchor/ Havells as approved by GE.
S&F as in replacement of unsv switch piano flush type single pole way 16 Amps complete, all as specified and as directed Make - Legrand/ Anchor/ Havells as approved by GE.
S&F in replacement of unsv socket outlet 2 in 1 3 pin 5/16 Amps flush type complete all as specified and as directed. Make - Legrand/ Anchor/ Havells as approved by GE.
Mahamaya Engineers Services
shivrefrigeration
JS CONSTRUCTION COMPANY
Amit Engineering
Friends fire Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .