Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 CrAccepted-AOC LANE NO4 INDUSTRIAL AREA BARI BRAHMANA JAMMU 181 133 | BARI BRAHMANA | SAMBA | JAMMU AND KASHMIR | 181133 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹7.4 Cr+₹23.6 L (3.28%)Rejected-Finance 108AD GREEN BELT PARK GANDHI NAGAR JAMMU 180 004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L2 | Rejected-Finance Not being the lowest bid | |
| 3 | L3₹7.5 Cr+₹27.3 L (3.80%)Rejected-Finance TAHAKUR COMPLEX NEAR JANTA FLOUR MILL GANGYAL JAMMU J K 180010 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180010 | L3 | Rejected-Finance Not being the lowest bid | |
| 4 | L4₹7.5 Cr+₹31.7 L (4.41%)Rejected-Finance | L4 | Rejected-Finance Not being the lowest bid |
| Sl No | Description | Qty | Unit | Ace Engineering Infratech India L1 | TawiTech Enterprises Private Limited L2 | SHER-E-KASHMIR CONSTRUCTION PRIVATE LIMITED L4 | EXACTEL L3 |
|---|---|---|---|---|---|---|---|
| 1.00Supply & Construction of Ammunition Storage Tunnel | |||||||
| 1.01 | Supply & Construction of Ammunition Storage Tunnel with portal of Size 9mtr height & width, all along the length of the tunnel. Tunnel Support System: Temporary and permanent support system including rock bolts, steel ribs, lattice girder and Shortcrete to follow IS 13365 (Part 1-3). The Bureau of Indian Standards (BIS) Code for rock mass classification and selection of support system to be followed. Sesmic Zone. The tunnel should be constructed following norms of analysis for structures passing through zone (v) as it is crucial to tunnels in the Himalayan belt (IS 1893 (Part-1): 2016). Concrete Lining. The tunnel will be constructed using design mix, durability requirements, and structural calculations for the final cast in place concrete lining (IS Code 456: 2000 (or updated)). . Note: - Only approved makes to be used in the confirming relevant IS codes. | 37.5 | Mtrs | 19,01,000 ₹7,12,87,500 Lowest | 19,62,666.67 ₹7,36,00,000 | 19,73,333.33 ₹7,39,99,999.99 | 19,72,480 ₹7,39,68,000 |
| 1.02 | Ventilation. IRC:SP :91-2019
(a) Reversible axial jet fan, tunnel type, minimum 315–400 mm dia., high-thrust type, suitable for longitudinal ventilation, complete with mounting brackets and vibration isolators | 4 | Nos | 16,000 ₹64,000 Lowest | 16,500 ₹66,000 | 33,000 ₹1,32,000 | 16,852 ₹67,408 |
| 1.03 | Jet fan electric motor, IE3/IE4, 3-phase, 415 V, complete with accessories | 4 | Set | 14,000 ₹56,000 Lowest | 14,500 ₹58,000 | 27,000 ₹1,08,000 | 14,572 ₹58,288 |
| 1.04 | Jet-fan VFD/control starter suitable for reversible operation | 4 | Nos | 6,500 ₹26,000 Lowest | 6,800 ₹27,200 | 13,500 ₹54,000 | 6,834 ₹27,336 |
| 1.05 | Fire-resistant cabling for jet fans, complete with cable tray/supports | 100 | Mtrs | 40 ₹4,000 Lowest | 50 ₹5,000 | 78 ₹7,800 | 50.5 ₹5,050 |
| 1.06 | CO detector, tunnel type, with local indication and 4–20 mA/RS-485 output | 4 | Nos | 550 ₹2,200 Lowest | 580 ₹2,320 | 1,100 ₹4,400 | 583 ₹2,332 |
| 1.07 | Visibility/smoke detector/transmissometer | 2 | Nos | 650 ₹1,300 Lowest | 700 ₹1,400 | 1,350 ₹2,700 | 705 ₹1,410 |
| 1.08 | Tunnel ventilation control panel with PLC, auto/manual operation, fan sequencing, fault indication and emergency override | 2 | Set | 6,500 ₹13,000 Lowest | 6,800 ₹13,600 | 13,500 ₹27,000 | 6,834 ₹13,668 |
| 1.09 | Local jet-fan isolator/control station | 4 | Nos | 2,500 ₹10,000 Lowest | 2,750 ₹11,000 | 5,000 ₹20,000 | 2,764 ₹11,056 |
Tender Value
Refer Docs
EMD Value
₹22.5 L
Closing Date
17 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CO, 8 ENGINEER REGIMENT
CO, 8 ENGINEER REGIMENT
SUPPLY AND CONSTRUCTION OF AMMUNITION STORAGE TUNNEL
2026_ARMY_787920_1
OT/NC/16/16CAB/6956/(II)
Limited
Civil Works
Item Rate
NARIAN
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
CO, 8 ENGINEER REGT
₹22.5 L
28 Sept 2026
5 Sept 2026
19 Sept 2026
5 Sept 2026
17 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply & Construction of Ammunition Storage Tunnel | |||||
| 1.01 | Supply & Construction of Ammunition Storage Tunnel with portal of Size 9mtr height & width, all along the length of the tunnel. Tunnel Support System: Temporary and permanent support system including rock bolts, steel ribs, lattice girder and Shortcrete to follow IS 13365 (Part 1-3). The Bureau of Indian Standards (BIS) Code for rock mass classification and selection of support system to be followed. Sesmic Zone. The tunnel should be constructed following norms of analysis for structures passing through zone (v) as it is crucial to tunnels in the Himalayan belt (IS 1893 (Part-1): 2016). Concrete Lining. The tunnel will be constructed using design mix, durability requirements, and structural calculations for the final cast in place concrete lining (IS Code 456: 2000 (or updated)). . Note: - Only approved makes to be used in the confirming relevant IS codes. | 37.5 | Mtrs | - | - |
| 1.02 | Ventilation. IRC:SP :91-2019
(a) Reversible axial jet fan, tunnel type, minimum 315–400 mm dia., high-thrust type, suitable for longitudinal ventilation, complete with mounting brackets and vibration isolators | 4 | Nos | - | - |
| 1.03 | Jet fan electric motor, IE3/IE4, 3-phase, 415 V, complete with accessories | 4 | Set | - | - |
| 1.04 | Jet-fan VFD/control starter suitable for reversible operation | 4 | Nos | - | - |
| 1.05 | Fire-resistant cabling for jet fans, complete with cable tray/supports | 100 | Mtrs | - | - |
| 1.06 | CO detector, tunnel type, with local indication and 4–20 mA/RS-485 output | 4 | Nos | - | - |
| 1.07 | Visibility/smoke detector/transmissometer | 2 | Nos | - | - |
| 1.08 | Tunnel ventilation control panel with PLC, auto/manual operation, fan sequencing, fault indication and emergency override | 2 | Set | - | - |
| 1.09 | Local jet-fan isolator/control station | 4 | Nos | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
FINALRFP.pdf
Tender Documents • 4.91 MB
BOQ_883094.xls
BOQ • 0.30 MB
Corrigendum1.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .