Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹13.0 L
Closing Date
30 Jun 2026, 2:30 pm
Improvement of working spaces in plant, Ancillary buildings, store depot and staff amenity buildings at RWP/Bela
05_RWP_Engg_26_27_WT_Open
05_RWP_Engg_26_27_WT_Open
Open
12 Months
Hamirpur, Himachal Pradesh
₹0
₹13.0 L
30 May 2026
30 May 2026
16 Jun 2026
8 Jun 2026
Item Breakup - B-Schedule-B
Item Breakup - A1-Schedule-A1
Providing & fixing superior quality of Square Blinds for windows of approved make as Foot per the director of engineer -in-charge including fixing of red and all necessary hardware, as a complete job Total 525000.00
Item Breakup - A2-Schedule-A2
Supplying, fitting & fixing Consisting the Sqm following main items for sound proofing/acoustic effect. (a) MiS Channel/ Frame 25X25 mm (Thickness 26 SWG) in wall for securing of acoustic panel/sheet material as mentioned in the item b& c below channels spacing will be 600 X 600mm minimum in any direction.(b) Glass wool layer average thickness 50mm, density =36.0kg/cum for acoustic insulation with aluminum foil and other fittings. (c) perforated gypsum board 600X600mm ( 12mm thick) of saint gobin make or similar over the glass wooi layer (d) Superior quality sofa febric Raymond cloth with moulded decorative teak wood beats as per direction of Engineer. Rate is inclusive of cost of ali material, labour, scaffolding, tools& plants, transportation, lead & lift all texes/vat etc. complete in fall respect as per specification of site in charge
WORKSTATION SIZE: 1500L X 600D X Numbers 750HT, TOP WITH 450MM HT SCREEN Specifications Tep: Made of 25mm thick prelaminated particle board of approved shade confirming to E1 norms. All the edges of workstation surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Main Screen: Anodized 30 screen, finishes with fabric magnetic & glass marker tiles. Passage tile fabric only. Under Structure: Top is supported on MS Powder coated Connect Legs constructed by using high pressure die casting connectors, Dia 44.50 ERW Tube - 16g, clear & tough polycarbonate leg bush & swivel type levelers a very tough material. Legs are connected using cross beams made of 40 x 20 16 gauge rectangular tube and connected to legs with aluminium die cast wing connectors. Wire Management: The Raceways are provided below the work surface for carrying wires from one end to other end of the cluster, Size offered is 250mm Ht, Thickness 70mm. Provided with separator for data and power cables. Designed to accommodate 50-60 CAT-6 cables. With vertical wire entry cover & 450mm Anodised flip up Made of Aluminum in anodised finish, which has
PLB COMPOSITE STORAGE 2D1F - Fixed Numbers with above workstation SIZE: 1050W X 450D X 640MM HT Specifications: The storage top 25mm thick, shutter & sides panel are made of 18mm thick & back panle is made of 18mm thick prelaminated particle board of approved shade .. Ali the edges of storage surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Adjustable shelves, auto closing hinges, locking mechanism, finger groove handles and 2D+1F Drawer unit with Regular locking system.
Providing Metal CPU, Trolley with Wheels Numbers RWPBELA HQ-ENGINEERING/RWP/BELA
Providing Keyboard tray
CABIN STATION: 1500L X 750D X 750HT TABLE TOP SIDE COMP STORAGE 2D1F: 1200L X 450D X 640HT Specifications: Top: Made of 25mm thick prelaminated particle board of approved shade confirming to El norms. All the edges of cabin table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Modesty Panel: 18mm thick 450mm ht PLT modesty panel is considered. Which is machine pressed 2mm thick imported PVC lipping giued with hotmelt Eva glue free from any VOC. Under Structure: Table top is supported on MS Powder coated Connect Legs constructed by using high pressure die casting connectors, Dia 44.50 ERW Tube - 16g, clear & tough polycarbonate leg bush & swivel type levelers a very tough materiai. Legs are connected using cross beams made of 40 x 20 16 gauge rectangular tube and connected to legs with aluminium die cast wing connectors. Wire Management: 350mm Anodised flip up Made of Aluminum in anodised finish, which has soft closure and three way wire acess & FVC cable dump. Vertebra for wire entry. Side Composite Storage 2D1F: Storage is made of 25mm thick top, 18mm
Premium Executive Desk with glass top Numbers Main Table: W 2100 x D 1000 x H 750mm Extention: W 1400 x D 550 x H 750mm
Mid Back Revolving Chair Self Calibrating Numbers 150.00 Multilock Mechanism Adjustable Lumbar Support One Way Adjustable Arms (Height) Nylon Base Fabric Uphoister Cushion Seat
U-shape Conference Table 21 seater:- Numbers description :- Length of Each Seat of Work Top +/-20 mm*-600 MM for singhle, Depth of Work Top +/- 20mm* 650 MM, Height of Work Top +/-20 mm*-750 MM, length of one side 4800 MM, size, size of the width 2400 MM, Table top finish - Vaneer face coated with lacquer in cheery colour, Material of work top - 38mm calibrated BWP plywood board, Material of Gable end and modesty panel- Teak carved wook, provide buffer 08 number at ehe bottom, provide microphone setting, provide switch socket board in each work top users ACCEPTED MAKE- WELLFIN (Warranty Period: Upto 12 months from the dated of delivery.)
SIZE: 1200 LX 750 D X 750 HT TABLE Numbers T O P Specification: Top: Made of 25mm thick prelaminated particle board of approved shade confirming to El norms. All the edges of meeting table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC.
Cafe chair with polypropylene seat & Numbers backrest with powder coated 4 legs. RWPBELA HQ-ENGINEERING/RWP/BELA
Providing and fixing storage cabinet of Numbers size 2975(w) x 750(h) x 450(d) Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 1975(w) x 750(h) x 450(d) Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 5300(w) x 2400(h) x 450(d) Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 1800(w) x 750(h) x 450(d) Made of pre laminated HDHMR beard.
Providing and fixing storage cabinet of Numbers size 3150(w) x 750(h) x 450(d) Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 1800(w) x 2400(h) x 450(d). Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 3600(w) x 2400(h) x 450(d). Made of pre laminated HDHMR board.
Providing and fixing wardrobe of size Numbers 750(w) x 2400(h) x 450[d). Made of pre laminated HDHMR board.
Providing and fixing wardrobe of size Numbers 1050(w) x 2400(h) x 450(d) Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 2400(w) * 2400(h) * 450(d). Made of pre laminated HDHMR beard.
Providing and fixing storage cabinet of Numbers size 4150 y(w) x 2400(h) x 450(d). Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 4500(w) x 2400(h) x 450(d). Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 2100(w) x 2400(h) x 450(d). Made of pre laminated HDHMR board.
Providing and fixing storage cabinet of Numbers size 2100 (W) x 2400 (h) x 450(d). Made of pre laminated HDHMR board. Total 23628072.30
Item Breakup - E1-Schedule-E1
Supply of 3.5 C X 25 mm2 PVC insulated Metre and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.
Supply of 4 C X 16 mm2 PVC insulated Metre and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.
Supply of 4 C X 10 mm2 PVC insulated Metre and PVC sheathed XLPE Armored Aluminum power cable of 1.1 KV.
Supply of 4 C X 6 mm2 PVC insulated and Metre PVC sheathed XLPE Armored copper power cable of 1.1 KV.
Supply of 3 C X 10 mm2 PVC insulated Metre and PVC sheathed XLPE Armored copper power cable of 1.1 KV.
Supply of 1 C X 16 mm2 PVC insulated Metre and PVC sheathed XLPE Armored copper power cable of 1.1 KV. RWPBELA HQ-ENGINEERING/RWP/BELA
Supplying and making indoor end Each termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i)3½ X 240 sq. mm (50mm)
(ii)3½ X 25 sq. mm (25 mm)
(iii)4 X 16 sq. mm (28mm)
(iv)4 X 10 sq. mm (25 mm)
(v)3 X 10 sq. mm (22 mm)
Laying and fixing of one number PVC Metre insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and installing following size of Metre perforated Hot Dipped, Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling / shaft with G.I. suspenders including G.I. bolts & nuts, etc. as required & approved by the Engineer Incharge. (Quantity shall be confirmed at site as per final layout/ route/ application etc. & to be executed accordingly.) (i)100 mm width X 50 mm depth X 1.6 mm thickness
(ii)300 mm width X 50 mm depth X 1.6 Metre mm thickness
Supplying and installing following size of Each perforated Hot Dipped, Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling / shaft with G.I. suspenders including G.I. bolts & nuts, etc. as required. (i)100 mm width X50 mm depth X 1.6 mm thickness
(ii)300 mm width X 50 mm depth X 1.6 Each mm thickness
Supplying, Receiving, Unloading, Storing, Metre Handling, Shifting to its location and Laying of 16 SWG single compartment Aluminium / GI Trunking with 16 SWG openable covers at regular intervals along with necessary cable support system as directed including providing & fixing accessories like suitable Clamps, Dash Fasteners, Cable Ties, Gaskets etc. complete in all respects (All Trunking is to be cleaned thoroughly before pulling any wires / cables); including earthing of trunking with 4 sq. mm FR-LSH PVC insulated Yellow + Green Copper Earth Wire with proper thimbles. All joints of Al / GI Trunking shall be provided with Suitable size of the Junction Box. as required. The rate shall be inclusive of 'Floor /wall cutting ,chipping, removal of debris, plastering in the floor/wall to make good finish and to match with the original surface etc. (i)300 x 38MM GI Trunking RWPBELA HQ-ENGINEERING/RWP/BELA
(ii)200 x 38 MM GI Trunking
(iii)150 x 38MM GI Trunking
(iv)100 x 38MM GI Trunking
(v)50 x 38MM GI Trunking
Supply and installation of Junction boxes Numbers as per the following requirement and specs. The Job include the necessary covering of JB with thermocoal. Job also includes the necessary identification of JB at the time of tiling or wire pulling as per requirement. The rate shall be inclusive of 'Floor /wall cutting, chipping, removal of debris, plastering in the floor/wall to make good finish and to match with the original surface etc. (i)315 x 315 x 50 GI Junction box (14 SWG) with 2mm cover plate
(ii)215 x 215 x 50 GI junction box (14 Numbers SWG) with 2mm cover plate
(iv)115 x 115 x 50 GI junction box (14 Numbers SWG) with 2mm cover plate
(v)65 x 65 x 50 GI junction box (14 SWG) Numbers with 2mm cover plate
DISTRIBUTION BOARDS Supplying and Each fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Size:6 way, Double door
Supplying and fixing following way, Each horizontal type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) (i)8 way (4 +24), Double door
(ii)6 way (4 + 18), Double door
Supplying and fixing 40A rating, double Each pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 40 Amps rating, Each double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 Amps rating, four Each pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of Single pole, 5 Each amps to 32 amps rating, 240/415 volts,10KA, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. RWPBELA HQ-ENGINEERING/RWP/BELA
POINT WIRING Wiring for light point/ fan Point point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group-C
Supplying and fixing suitable size GI box Each with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box Each with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying & fixing suitable size GI box Each wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (For Geyser/AC etc.)
Supply, commissioning of 1.5 ton, Wall mount type, 5 Star, inverter variable speed Split type Air conditioners.
Wiring for circuit/ submain wiring Metre alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. (i)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
(ii)2 X 4 sq. mm + 1 X 4 sq. mm earth Metre wire
(iii)2 X 6 sq. mm + 1 X 6 sq. mm earth Metre wire
(iv)2 X 10 sq. mm + 1 X 6 sq. mm earth Metre wire
LIGHT installation, testing & commissioning of 36W Recessed SMD LED 2'x2' luminaire delivering an initial system lumen of 3600 lumens & the luminaire shall be with system efficacy 100 lm / W. Housing: CRCA powder coated. Optics: HET Plastic Diffuser, IP20 Protection, Dim: 595mm X 595mm. The operating CCT shall be 5700K with CRI of 80, . The luminaire shall be BIS Registered with electronic driver with input voltage range of 140 to 300V , THD 10% & PF 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. Luminaire shall have minimum surge protection of 3KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture RWPBELA HQ-ENGINEERING/RWP/BELA
Supply, Commissioning of 15W Surface DownLight Luminaire with Aluminium Alloy heat Sink for efficient heat dissipation and diffuser made up of High quality polycarbonate diffuser to enhance the aesthic of the fixture and to provide glare free uniform light distribution, Powered by an independent output electronic LED driver (SMPS based constant current supply) with Output Short- circuit protection, Surge Voltage protection & other safety test as per IS:15885 Part 2/Sec 13. Power Consumption not greater than 18W and System Efficacy not less than 100 Lumens/Watt, CCT 5700K PF>0.95, CRI>80 ,THD<=10%. LED Average life L70B50: 50000 hours.Operating temperature: -10 °C to +35 °C , Operating voltage range: 140 V - 270 V,. Luminaire Should conform to IP20 Classification. Test report to be submitted; photo biological safety norms: IS15885, test certificate to be submitted; certification: LM 79 for luminaire and LM80 for led source, Driver and Fixture to be BIS certified
Supply, Commissioning of of exhaust fans/ wall fan/Ceiling Fans of following sizes including making the holes to suit the size of the fan and making good the damages, including providing and fixing of louvers/ shutters, connection, testing and commissioning Ceiling BLDC Fan 600 mm, ISI Marked . Make:-Orient, Havells, Atomberg,
Supply, Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, commissioning of following sizes Exhaust fan with Louver suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. 8 inches Louver Type exhaust fan suitable for operation on 1- Phase. Crompton, Almonard, Usha, Havells:- Smart ventilair Model no. (FHVTMDXWHT08). RWPBELA HQ-ENGINEERING/RWP/BELA
Supplying and fixing two module stepped Each type fan regulator on existing modular plate switch box including connections but excluding modular plate.
GI PIPE Supplying & embedding GI pipe in Metre pole collar for cable entry including bedding the pipe to required shape as required. 40 mm dia
UPS & INVERTER Supply & Installation of Set 40kVA UPS system with battery, with battery backup of 30 minutes.
EARTHING EARTHING & EARTH WORK Set Supplying, Installation, testing & commissioning of long life, Maintenance Free Electrolytic Earthing System with 10 feet rod, 25mm dia. The system should be stable operation for at least 15 Years. The electrode shall be 250 micron cu coated MS rod ,UL Listed and CPRI tested. The electrode shall be surrounded by at least 50 kgs (25kg x 2bags) of Ground Enhancing material reslow to provide maximum contact between the electrode and the backfill. The product should meet the requirement as per IS-3043 or any equivalent international specification (UL). Chemicals used should be environmental friendly. (The Installation procedures should be followed as instructed by the Earth Electrode Supplier). Providing masonry enclosure with heavy duty SFRC cover having locking arrangement, disconnecting / testing links, including excavation and backfilling etc. complete as required.
Providing and fixing 25 mm X 5 mm G.I. Metre strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire Metre on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
MISCELLANEOUS WORKS Supply and Each Installation of First aid box conforming to IS : 2217-1963.
Supply treatment chart in Hindi and English duly mounted on a wooden frame with glass.
Supply and Installation of Rubber mat 1m Each x 2m x 3mm. thick to withstand 1.1 KV dielectric strength as per IS : 5424 - 1969.
Supply and Installation of Rubber gloves Each of 1.1 KV grade as per IS 4770-68.
Supply, commissioning of Mannual Call Point.
Supply, commissioning of Control Module (Output).
Supply, commissioning of Conventional Strove (Hooter).
Supply, commissioning of 2 core 1.5 Sq mm fire alarm grade copper conductor cable conforming to relevant standards. RWPBELA HQ-ENGINEERING/RWP/BELA
Supply, installation & commissioning of Metre 20mm PVC conduit
Supply, installation & commissioning of Numbers 20mm Elbow.
Supply, installation & commissioning of Numbers 20mm Tee.
Supply, installation & commissioning of Numbers 320.00 2-way circular.
Supply, installation & commissioning of Numbers 400.00 3-way circular
Supply, installation & commissioning of Numbers 160.00 4-way circular.
Supply, commissioning of alarm Panel (4 Loop).
Supply, installation & commissioning of Numbers China saddle.
INTERNAL ELECTRICAL WORKS SUB- Set HEAD-1 L.T. PANELS Design, Fabrication, Supply, Installation, Testing and Commissioning of L.T. Panels manufactured out of 14 S.W.G. C.R.C.A. sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components. 1. MAIN L.T. PANEL Supply, unloading, installation, testing and commissioning of the following cubical type panels made of 2.0 CRCA structure, base channel SMC, doors & sheet metal partitions complete with, Moulded Case Circuit Breakers, meters, indicating lamps, current transformer, control MCB etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve, supported on FRP / SMC supports in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. & comprising of compartments with hinged door for each feeder & its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket, attractively powder coated with Approved Paint shade. The panel shall be free standing type/ wall mounted type as per drawing and comprising with foundation & Masonary works including ducting. Note:- MCCB's upto 250A shall be with Adjustable thermal-magnetic release with O/C & S/C protection of 25kA. All MCCB's shall be provided with front door operating handle, Phase Spreaders & Phase Barriers. TPN MCCB Shall mean 3 Pole MCCB with Adequate size of heavy duty separate neutral link. Metering CTs burden shall be 15VA & accuracy class 1.0. CTs shall be "Cast Resin" type. All indication lights shall be LED type. All meters shall be "DIGITAL" type. Degree of Protection for Indoor panels shall be IP-54. Degree of Protection for Outdoor panels shall be IP-55 with canopy and double door. Outdoor panel cable entry shall be from bottom only. Panel space heaters with control MCB & Thermostat, covered CFL lamp controlled by door RWPBELA HQ-ENGINEERING/RWP/BELA switch for each panel bay. Gland plates shall be 2mm thick for LT. Panels upto 400A Incomer Panel Manufacturer should have Type Test Certificates for Short Time withstand current test of 50KA for 1.0 Sec from CPRI. "ON" & "OFF" Indicating lamp with control MCB shall be provided for all MCCB out going feeders unless otherwise specified. Control SP MCB's of 2 /4A Rating shall be provided for each metering circuit. 1.1MDB- 1(LIGHT + POWER) Incoming 1 No. 200 Amp FP,36kA MCCB with O/C, S/C protection. Bus bars 1 Set of 250-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Copper bus- bars with colour coded PVC heat shrinkable sleeves. Metering & Indication One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi-Function Meters features (A/V/kW/kWh) display ON/OFF/TRIP indication lamp for incomer Outgoing 3 Nos. 125 Amp TP,16kA MCCB with O/C, S/C protection with energy meter, ON OFF TRIP indication lamp. 10 Nos. 63 Amp FP MCB of 10kA. 6 Nos. 40 Amp FP MCB of 10kA . MDB-1(Light + Power) Panel as mentioned above should be complete in all respect with internal wiring, copper bus bar and all other required hardware and accessories.
UPS OUTPUT PANEL Incoming 2 No. 125 Metre Amp FP MCCB with O/C, S/C protection. Bus bars 1 Set of 160-Amps, 3-Phase, 4- wire, 415 volts, 50 Hz Copper bus- bars with colour coded PVC heat shrinkable sleeves. Metering & Indication One set of R/Y/B phase indication Lamp & MCB. 1 No. Multi-Function Meters features (A/V/kW/kWh) display ON/OFF/TRIP indication lamp for incomer Outgoing 15 Nos. 63 Amp FP MCB of 10 kA. UPS output Panel as mentioned above should be complete in all respect with internal wiring, copper bus bar and all other required hardware and accessories.
Supply of following size of 1.1KV grade Metre multicore XLPE insulated & PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988 complete as required. 3.5 core, 240 Sq.mm. Al Cable
Fire Alarm and smoke Detection System Numbers 320.00 Fire Alarm and smoke Detection System Supply, installation, connection & commissioning of SMOKE DETECTOR - A) 1st Floor 150 Nos. B) Ground Floor 170 Nos.
Supply and installation of Junction boxes Numbers as per the following requirement and specs. The Job include the necessary covering of JB with thermocoal. Job also includes the necessary identification of JB at the time of tiling or wire pulling as per requirement. The rate shall be inclusive of 'Floor /wall cutting, chipping, removal of debris, plastering in the floor/wall to make good finish and to match with the original surface etc. (v)65 x 65 x 50 GI junction box (14 SWG) with 2mm cover plate Total 15228192.56
Item Breakup - E2-Schedule-E2
Supplying and fixing following size/ Each modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm), Make- Reputed
WIRING FOR DATA SYSTEM Supplying Metre and drawing of UTP 4 Pair CAT 6 Cable in the existing surface/ recessed Steel/ PVC conduit as required. (For Data/Voice) CAT 6 Cable, Make- FFC/ Similar
IT COMPONENT & WIRING Supply, Numbers 575.00 Installation, Testing & Commissioning of following IT components Cat-6 information outlet RJ45 , Make- Reputed
Supply of 9U rack indoor/outdoor for Set switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit. Make- Reputed. Total 1333875.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Annexure-J.pdf
ATTACHMENT
CorrigenduminGCCforGST1.pdf
ATTACHMENT
Process_080218_1.pdf
ATTACHMENT
2018_CE-I_CT_9Date04_06_2018LC_1.pdf
ATTACHMENT
CorrigenduminGCCforGST_2.pdf
ATTACHMENT
DSRAORSpecification-HorticultureLandscaping2020.pdf
ATTACHMENT
GCC-2022AdvanceCorrectionSlipon14.07.2022.pdf
ATTACHMENT
AdoptionofCPWD06.12.2019.pdf
ATTACHMENT
BGFormatAnnexure-IV.pdf
ATTACHMENT
ACTAnnexure-VIB.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
BidsecurityAsBankGuaranteeAnnexure-VIA.pdf
ATTACHMENT
DSRVol_-22021.pdf
ATTACHMENT
DSRVolo_12021C.pdf
ATTACHMENT
GCC-2022AdvanceCorrectionSlipno.01.pdf
ATTACHMENT
AdvanceCorrectionSlip4_1.pdf
ATTACHMENT
GCC2022AdvanceCorrectionNo.05.pdf
ATTACHMENT
GCC2022AdvanceCorrectionNo.02.pdf
ATTACHMENT
Correctionslip7.pdf
ATTACHMENT
GCC2022AdvanceCorrectionNo.03.pdf
ATTACHMENT
GCCCorrectionslip-9_1.pdf
ATTACHMENT
Correctionslip8.pdf
ATTACHMENT
IncreasedGSTDated04.001.2023.pdf
ATTACHMENT
Annexure-V.pdf
ATTACHMENT
GCC2022AdvanceCorrectionNo.06.pdf
ATTACHMENT
Annexure-XVII.pdf
ATTACHMENT
TenderDocument1.pdf
ATTACHMENT
RailwayBoardletterdated06.04.2023.pdf
ATTACHMENT
Download all tender documents and submit your bid