Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹17 L
EMD Value
₹42,500
Closing Date
22 Mar 2025, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SECRETARY,ANAKKAYAM GRAMA PANCHAYAT
ANAKKAYAM GRAMA PANCHAYAT, ANAKKAYAM P.O 676509 Malappuram Dist
Repairing Work of Minimast Lights
2025_DP_751039_1
A1-1071/25
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
ANAKKAYAM GRAMA PANCHAYAT, ANAKKAYAM P.O
Please refer Tender documents
9 documents required · 9 mandatory
₹2,950
Yes
₹42,500
Yes
24 Mar 2025
15 Mar 2025
24 Mar 2025
15 Mar 2025
22 Mar 2025
15 Mar 2025
Amount
Electrical
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD400748/2024-2025:Supply and installation of dust and vermin proof Three-phase sintex motherboard (GS MB?6535) 650*350*250 and to fix kseb meters, fuse unit, CTs, etc. as required including fixing it on the wall, making good the damages, color washing, etc. as required
OD400749/2024-2025:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
OD400747/2024-2025:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD400750/2024-2025:Supply,installation,testing and commissioning of 40A, 2pole , AC1 rated power contactor with 1NO+1NC auxiliary contacts with AC coil and 24Hours timer for operating automatic ON-OFF function suitable for single phase supply
OD400745/2024-2025:Supply and Fixing of 1P+N,40KA,1 module surge protector on existing MCB DB/enclosure/Meter Board etc and giving connection as required. (Schneider A9L40500 or equivalent).
OD400746/2024-2025:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
SUNDAR MOHAN.K.P (BID ID -2166077)
BOSS LIGHT (BID ID -2165222)
Bidder Name
P. R. RIJESH
BOSS LIGHT
SUNDAR MOHAN.K.P
stage.html
html • 0.02 MB
finance_1216486.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .