Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.0 LAccepted-AOC | 1 | Accepted-AOC AGREEMENT EXECUTED | |
| 2 | 2₹11.0 L+₹727 (0.07%)Rejected-Finance PARUVAYAD W VIILITAITHUNAD ALUVA SRM 600017 | ERNAKULAM | KERALA | 680667 | 2 | Rejected-Finance REJECTED | |
| 3 | Rejected-Technical 21 1307 B ANUPALLAVI PALLURUTHY COCHIN 682006 | COCHIN | ERNAKULAM | KERALA | 682006 | - | Rejected-Technical L3 REJECTED | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-LICENSE |
Tender Value
₹11.0 L
EMD Value
₹27,700
Closing Date
19 Mar 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
Kochi Municipal Corporation, Park Avenue Ernakulam, Kochi 682011
Kochi Municipal Corporation S.877/22 DIV 42-Providing Generator, Lift Electrical connection to various offices and allied works attached to Vennala Mahila Samacham Building in DIV-42 Kochi Municipal Corporation
2022_LSGD_481400_1
Kochi Municipal Corporation S.877/22
Open Tender
Electrical Works
Item Rate
90 days
Ernakulam
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,800
Yes
₹27,700
Yes
4 Aug 2023
11 Mar 2022
21 Mar 2022
11 Mar 2022
19 Mar 2022
11 Mar 2022
30 days
Amount
PART I-Appendix A-(Installation of DG set and Electrification (Materials used for the work shall be as per the List of materials approved by the CCTCE and attached as separate document)
14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.10 : Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
od1671744/2021_2022 : Steel reinforcement for R.C.C work including straightening,cutting,bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more(Data 5.22.6 from civil work)
od1671745/2021_2022 : Supply, Loading, Conveyance, Unloading, Errection, Testing and Commissioning of 40 KVA/32KW DG Set with Acoustic enclosure as per CPCB norms and as detailed below -A. Engine - 1. Make of engine - Kirloskar/ Kumins/ Greens ( a. Type of Engine - Diesel Engine. b. No of Cylinders - As per manufactures standards. c. Method of cooling -Radiator cooled . d. Aspiration - Turbo charged . e. Design - Suitable for generating set operation. f. Output - Suitable for generating set operation. 2. Standard accessories with Diesel Engine( a. Fly wheel. b. Close Coupled.c. Air cleaner. d. Raditor e. Fuel Pump.f. Fuel filter. g. Lubricating oil filter.h Residential type exhaust silencer. 3. Battery Charger and charging Generator 4. Engine Instrument Panel with the following items. Starting switch with key or button ,Lubricating oil pressure gauge, Water temperature gauge, RPM Indicator with hour meter, Battery charging ammeter. 5. Saftey Controls for Engine- Battery control (trip) for low lubricating oil pressure, Battery control (trip) for high water temperature.) B.Alternator Brushless alternator(. Make - Kirloskar/ KEL /Crompton, Type - Self exited and self regulated, Capacity - 40 KVA @ 0.8PF, System of Voltage - 3Phase, 415V, 4Wire System, Speed - 1500 rpm, Frequency - 50Hz, Insulation - Class F/HThe alternator should confirm to IS 4722/IS13365. )..Metallic DNB - 1No, Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection to be provided C.Fuel Tank- Suitable size fitted (built in type) inside the acoustic enclosure . D. Battery Charger-Suitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required. E.Standard control panel, 1No multifunction meter suitable for display of current, voltage , frequency, power factor, KVA, KW etc, 1No separate KWH meter, Necessary measuring CTs of appropriate ratio and burdon for the required meter, Instrument fuse/MCB , 2 years warranty for DG set . F.AMF Panel with power contactor as per standard of Kerala State Electrical inspecterate. Lub Oil & Diesel First full fill of lub oil and Diesel, etc as required. Operation and service manual shall be provided
od1671746/2021_2022 : Errection of 40 KVA DG set on existing platform including commissioning,trail running on load including cost of diesel
od1671748/2021_2022 : Supply and providing 65mm or nearest size C class MS pipe conforming to relevant IS specIfications completewith the heavy gauge specials such as bends, flanges, etc, welded and fixed at appropriate locations ,providing cork sheet in between the flanges at the joints , bolting the flanges together, painting the pipe , flange etc with 2 coats heat resistant paint suitable for outdoor applications , fixing the pipe firmly with fabricated structure, wall / any other mechanical support etc as required.
od1671750/2021_2022 : Fees to be paid to Electrical inspecterate towards prepertion of scheme of the complete electrrical installation for submitting to the Electrical inspecterate ,prepering all the documentation including payment of the statutary fees to be paid to Electrical inspecterate for getting sanction of energisation of the DG set.(Payment will be made as per the paid vouchers received )
5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
od1671751/2021_2022 : Providing and fixing 20mm X 3 mm copper strip from earth electrode to earth bus /generator body/neutral point etc as required.
5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
90.16.5.6 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
od1671753/2021_2022 : Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
od1672302/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).<br>Single control light point without ceiling rose - Short point
90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.2 : Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
od1672489/2021_2022 : Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20 mm 3core round copper conductor flexible chord etc as required.
od1672325/2021_2022 : Supply and installation of 1200mm sweap ceiling fan with standard accessories with out reglator including giving connection with 16/0.20 mm 3core round copper conductor flexible chord etc as required.(Crompton (High speed)/Havells(SS-390)
od1672340/2021_2022 : Supply, and installation of pre-wired surface/Recess mounting Crompton make LCTLRN-36-CDL(Recess 2x2 Tile)POLARIS III Ceiling light on existing down rod/steel chain and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS
od1672342/2021_2022 : Supply of recess mounting type 18 W, LED down panel light fitting 1'x1' size Crompton or -18W-CDL equivalant philips make with Profiled and flat diffuser , complete with all control accessaries dulywired.
od1672305/2021_2022 : Supply and installation of LED tube light fittings (Philips Endura high efficiency BN 308 C 20S CDL white) directly on ceiling/Wall with company made mounting accessaries and giving connection with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS
od1672306/2021_2022 : Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover with 9 W LED to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor fle x wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro /Philips/Crompton/Bajaj make)
od1672307/2021_2022 : Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200mm polished shade with 9W LED and giving connection etc as required
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
od1672308/2021_2022 : Supply and installation of 150 mm medium duty exhaust fan in plastic body Crompton make BRISK AIR NEO with air delivery 275 CMM /Almonard make with same air delivery) in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm 3core round copper conductor flexible chord etc required.
od1672314/2021_2022 : Supply and installation of 250 mm medium duty 2300 rpm ,exhaust fan in metal frame (Almonard/Crompton make) in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm 3core round copper conductor flexible chord etc required.
90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
od1672276/2021_2022 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual <br> current circuit breaker (RCCB), having a sensitivity current up to 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.<br>25 amps
od1672277/2021_2022 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (RCCB), having a sensitivity current up to 30/100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
od1671758/2021_2022 : Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
od1671759/2021_2022 : Supply and providing 150/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5 on panel board assembly
od1671760/2021_2022 : Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Part-II -Remuneration.(As per G.O.No.2996/2018/LSGD dated 25/11/2018 &G.O.(Rt)No.3277/2018/LSGD dated 31/12/2018). Not part of BOQ
Rich Engineers
CHANDRAMOHANAN
Bidder Name
CHANDRAMOHANAN
AJITH
Rich Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .