Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹30.5 L+₹1.5 L (5.34%)Rejected-Finance BLOCK NO 11 VIMLNATH APARTMENT PRATAP VILAS ROAD NEAR SATYA SAI SCHOOL JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹30.7 L+₹1.7 L (5.92%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹30.8 L+₹1.8 L (6.16%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹30.8 L+₹1.8 L (6.33%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L5 | Rejected-Finance Not lowest |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE (AF) Jamangar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE CEILING FAN, EXHAUST FAN AND OTHER APPLIANCES ALONG WITH CERTAIN CONNECTED REPAIR WORKS AT AIR FORCE STATION JAMNAGAR UNDER GE (AF) JAMNAGAR NO.2
2021_MES_466902_1
8304/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamangar No.2
₹55,000
Yes
4 Oct 2021
10 Aug 2021
1 Sept 2021
10 Aug 2021
31 Aug 2021
24 Aug 2021
Amount
Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted pedestal fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified and directed. Note:- Repairing such as rewinding, replacement of defective spare part, connecting wire,Over hauling and painting etc will be measured & paid separately under subsequent items.
M & L for rewinding of ceiling fan of any make by dismantling the ceiling fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multistranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of ceiling fan:-
1200mm sweep
1400 mm sweep
M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc. and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as directed. Rewinding should be carried out for the following size of exhaust fan :-
450mm sweep
300mm sweep
200mm sweep
M & L for rewinding of Pedestal fan motor of any make by dismantling the Pedestal fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete.Testing of fan should be carried out to entire satisfaction of Engr-in-charge. The size of pedestal fan for rewinding shall be as under:-
300 mm sweep.
450 mm sweep.
600 mm sweep.
All as per item No 4 above, but wall mounted fan / Air circulators of size 450 mm sweep.
All as per item No 4 above, but wall mounted fan / Air circulators of size 600 mm sweep.
Supply and fix in repair ball bearing of any size suitable for ceiling fan 1200 mm/1400 mm sweep complete all as specified and directed.
Supply and fix in repair Gun metal bush of any size suitable for ceiling fan of 1200mm/1400mm sweep complete all as specified and directed.
Supply and fix in repair Gun metal bush of any size suitable for exhaust fan 300/450mm sweep complete all as specified and directed.
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, for ceiling fans complete all as specified and directed.
Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust/bracket fan any size complete all as specified and directed.
Supply and fix in repair bolt, nuts, washer and split pin for the down rod of ceiling fan complete all as specified and directed.
Supply and connection in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete all as specified and directed.
Material and labour for painting of ceiling fan including blades by scrapping of old paint, filling of cavities formed, preparation/cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES/SM No with appropriate size letters using black paint complete all as specified and directed.
Material and labour for painting of exhaust fan including blades by scrapping of old paint ,filling of cavities formed,preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES /SM No with appropriate size letters using black paint complete all as specified and directed.
Assembling & fixing only ceiling fan 1200/1400 mm sweep complete with blades, down rod canopy etc including hanging in position and connecting including taking down old fan and deposited in Store yard of AGE E&M complete all as specified and directed.
Comprehensive maintenance of storage type electric water heater (geyser) comprising of the following checks/test including repair to unsv parts/components at different locations under GE (AF) Jamnagar-02. (i) Taking down geysers from existing position after disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of inner tank with descaling solution & water leakage testing of tank & rectification of leakage.Testing of thermostat for serviceability. (iv) Checking of pressure release valves & non return valve etc to ensures free movement / smooth operation of these components. (v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (vi) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified & directed.
Note: All major defective unserviceable components such as thermostat, storage tank, heating elements, safety valves etc required for replacement shall be measured and paid separately as supply only under respective items of this BOQ, however quoted rates shall be deemed to includes for minor spare parts such as nut- bolts, screw, glands, packing etc.The following capacity of storage water heater are catered for as under:-
25 Ltr Capacity
50 Ltr Capacity
Supply only thermostats ISI marked suitable for 25 / 50 litres capacity geyser (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only of safety valve / high pressure release valve ISI marked suitable for geyser of any capacity (as per existing make)
Supply only heating element of 1 or 1.5 KW capacity including rubber washers ISI marked. (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only heating element of 2 KW capacity including rubber washers ISI marked (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only storage tank made out of copper sheet and confirming to IS-2082 (1973), suitable for 25 litres capacity geysers (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only storage tank made out of copper sheet and confirming to IS-2082 (1973), suitable for 50 litres capacity geysers. (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only apparatus plate suitable for 25 litres capacity geysers (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only apparatus plate suitable for 50 litres capacity geysers (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
Supply only 15 mm dia PVC flexible connection pieces with PTMT hexagonal adopters and washer at both sides, 450 mm long.
Supply only brass chromium plated connection pieces with brass hexagonal adopters and washer at both side, suitable for 15 mm dia pipe and 450 mm long.
Supply only brass non return valve 15 mm dia, ISI marked suitable for geysers (as per existing make from the following) Make : ABC / Speer Hot / Crown / Power Pack
M&L for insulation material (Glass wool) for geysers of any capacity including removing old insulating material all as per manufacture instruction.
Material and labour painting of Geyser outer body cover blades by scrapping of old paint, filling of cavities formed, preparation/cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES/SM No. with appropriate size letters using black paint complete all as specified and directed. The painting shall be carried out to following cap of geysers:-
25 Litre cap
50 Litre cap
S&F in repair round cable PVC insulated, PVC sheathed, with 3 core copper conductor of size 2.5 Sqmm, ISI marked & connecting complete all as specified and directed.
Supply and fix on wall/ceiling/roof or laying in trenches 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc and excavation & earth work where required complete and connecting to water supply pipe line including taking down old tubing, all as specified and as directed.
Supply and fix in repair 15 mm size Angular cock, cast copper alloy chromium plated, screwed down high pressure with capstan head, screwed both ends for iron pipe or unions, all as specified and directed. Make: Jaquar Cat No.CON-053K or equivalent Cat No of Plumber / Hindware
Supply and fix in repair 15 mm size bib cock, cast copper alloy chromium plated , screwed down high pressure with capstan head, screwed both ends for iron pipe or unions, all as specified and directed. Make: Jaquar Cat No.CON-037KN or equivalent cat No of Plumber / Hindware
Periodical maintenance / servicing of solar water heater,flat plate collector type/ glass tube collector type, storage type with electrical backup of capacity 100 - 300 litres, as per manufacturer instruction comprising of the following works at different locations as per Engr-in-Charge directions. (a) Complete cleaning of solar system, removing of dirt dust etc. (b) Cleaning of heating surface glass with glass cleaning solution.(c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water. (d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection.(e) Checking of glass holding tube joint & rectification of leakage. (g) Replacement of unserviceable spare part. Note:-(i) Preventive maintenance shall be carried as per direction.(ii) Unserviceable spares parts will be measured & paid separately as supply only.(iii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta./Red ren(iv) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work.
Supply only solar glass tube suitable for glass tube collector of following size and cap
58 mm dia and 1800 mm long
58 mm dia and 2100 mm long
48 mm dia and 1800 mm long
Supply only Electrical back of capacity 2 KW, 230 V supply, with thermostat suitable for glass tube collector type solar water heater as per existing make.
Supply only Electrical back of capacity 3 KW, 230 V supply, with thermostat suitable for glass tube collector type solar water heater as per existing make.
Supply only outer side solar washer (black) "O" ring glass tube type suitable for glass tube collector type solar water heater as per existing make.
Supply only outer side solar tube cap for collector ( Plastic ) suitable for tube type solar water heater as per existing make.
Supply only Inner side solar tube cap for collector ( Plastic ) suitable for tube type solar water heater as per existing make.
Supply only Hot water tank for glass tube collector type water heating system of following capacity
100 Ltr cap solar water geyser as per existing make.
200 Ltr cap solar water geyser as per existing make.
300 Ltr cap solar water geyser as per existing make.
Supply only Back support for following sizes
100 Ltr cap solar water geyser as per existing make.
200 Ltr cap solar water geyser as per existing make.
300 Ltr cap solar water geyser as per existing make.
Supply only stand for following size
100 Ltr cap solar water geyser as per existing make.
200 Ltr cap solar water geyser as per existing make.
300 Ltr cap solar water geyser as per existing make.
M&L for Chemical cleaning of tube by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and directed.
M&L for Chemical cleaning of tank by providing chemical & removing all scale / dirt / dust etc as per manufacturer's instruction complete all as specified and directed.
M&L for fabrication of staging for fixing of tank on roof for solar water heater up to 2.5 metre height from roof top, fabricated with mild steel angle, flat, tee etc (using steel section of grade Fe-290 Grade 165) confirming to including nuts, bolts, washers, welding, drilling holes for bolts, painting over all two coats of synthetic enamel paint over one coat of primer including taking down / dismantling of old staging complete all as specified & directed.
S&F in repair 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to water tank. (Minimum weight 455 grams) complete.
Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150 c/c with both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I (2009) complete all as specified and directed.
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 10 Amp MCB SP, Legrand cat part No : 607841 or equivelent of L & T / Schneider
M&L Sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed for the following sizes of cables. .
Using two run of single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and one run of 4.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Using two run of single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and one run of 6.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Using two run of single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and one run of 2.5 sqmm copper conductor insulated cable using as earth wire Note : 2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including PVC casing and capping shall be measured as one unit
Supply and fix 500 ltr Rotational moulded polyethylene water storage tanks triple layered, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position etc complete all as specified and directed.
Supply and fix 250 ltr Rotational moulded polyethylene water storage tanks triple layered, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position etc complete all as specified and directed.
S&F in repair 15 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to HDPE water tank complete all as specified and directed.
S&F in repair 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed to HDPE water tank complete all as specified and directed.
Supplying and laying in replace of CPVC pipes SDR 11 & plain CPVC SDR 11 of 20 mm dia fittings with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, including clamps and all fittings and fixtures complete all as specified and directed. Make Supreme/Prince.
S&F in repair 20 Amp three pin top metal clad suitable for industrial socket Make-Havells / Crabtree / Anchor / Legrand.
S&F in repair 20 Amp three pin metal Plug suitable for industrial socket Make-Havells / Crabtree / Anchor / Legrand.
S&F in repair PVC plug top 15 Amps, single phase, 240 Volts. Make-Havells / Crabtree / Anchor / Legrand.
M&L for MCB single pole,5 to 32 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
Nirmal Construction
High Tech Consruction
jitendra c joisar
Vijay Construction Co
Pooja Enterprise
suvidhiconstruction
EVEREST BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .