Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.6 LAccepted-AOC AT KALINGA VIHAR VIA PATRAPADA DIST KHURDA ODISHA | KHORDHA | ODISHA | 751001 | L1 | Accepted-AOC Contract value excluding GST | |
| 2 | L2₹80.5 L+₹9.9 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Quoted amount excluding GST |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
25 Feb 2023, 5:00 pmClosed
General Manager (Mech.), Erection and Maintenance,
Office of G.M (Mech.), E and M, Rasulgargh, BBSR
Erection and painting of 04sets of H.R Gates of Kanupur Gate Erection Project
2023_OCCL_86005_1
E-Procurement Notice No. 51 /OCCL/2022-23 (on-line
Open Tender
Mechanical Works
Item Rate
150 days
Basudevpur, Keonjhar
Please refer tender Documents
3 documents required · 3 mandatory
₹11,800
₹82,000
Office of G.M (Mech.), E and M, Rasulgargh, BBSR
20 May 2023
10 Feb 2023
27 Feb 2023
10 Feb 2023
25 Feb 2023
10 Feb 2023
10 Feb 2023 - 15 Feb 2023
16 Feb 2023
Amount
Head Regulator Service Gates of size 2300mm x 2800mm. (04 Nos)
Chipping of concrete surface for proper bonding between 1st stage and 2nd stage concreting.
Concrete cutting using chisel and demolition hammer to bring the gate grooves to required size for erection of 2nd stage embedded parts complete.
Fixing of Ø16 mm dowel bars by drilling Ø20 mm drill holes using bond chemical of approved reputed brand.
2nd stage concreting of embedded parts by M25 grade concrete using 20mm and down grade aggregates.
Erection of 2nd stage embedded parts for Head Regulator Service Gates of size 2300mm x 2800mm.
Erection of Head Regulator Service Gates of size 2300mm x 2800mm including light test for proper sealing.
Erection, Commissioning and Testing of 12T rope drum hoist with hoist supporting structures pertaining to Head Regulator service gates.
Head Regulator Emergency gates of size 2300mm x 2800mm. (04 Nos)
Chipping of concrete surface for proper bonding between 1st stage and 2nd stage concreting.
Concrete cutting using chisel and demolition hammer to bring the gate grooves to required size for erection of 2nd stage embedded parts.
Fixing of Ø16 mm dowel bars by drilling Ø20 mm drill holes using bond chemical of approved reputed brand.
2nd stage concreting of embedded parts by M25 grade concrete using 20mm and down grade aggregates.
Erection of 2nd stage embedded parts for Head Regulator Emergency gates of size 2300mm x 2800mm .
Erection of Head Regulator Emergency gates of size 2300mm x 2800mm including light test for proper sealing.
Erection, Commissioning and Testing of 20T rope drum hoist with hoist supporting structures pertaining to Head Regulator emergency gates.
Painting
Painting of Head Regulator service & emergency gates of size 2300mm x 2800mm “after blast cleaning process, performed with sand as per requirements and class ‘A’ of IS14177:1994. After blast cleaning, the surface should be cleaned from loose dust and debris by air blast with help of blower. Over the prepared surfaces, two coats of zinc rich primer should be applied to give a total dry film thickness of 70 ± 5 microns followed by two coats of solvent less black Epoxy Paint applied at an interval of 24 hours between each coat. Each coat should give a minimum dry film thickness of 150 ± 5 microns. The total dry film thickness of all the coats including primer coating should not be less than 350 microns as per IS: 14177:1994 including compressor, paints, thinner, painting equipments, sand, labour, other machinery, scaffolding etc
Painting of hoisting arrangements for head regulator service and emergency gates of 12T & 20T respectively after blast cleaning process,performed with sand as per requirements and class ‘A’ of IS14177:1994. After blast cleaning, the surface should be cleaned from loose dust and debris by air blast with help of blower. Over the prepared surfaces, two coats of zinc rich primer should be applied to give a total dry film thickness of 70 ± 5 microns followed by two coats of aluminum Paint applied at an interval of 24 hours between each coat. Each coat should give a minimum dry film thickness of 150 ± 5 microns. The total dry film thickness of all the coats including primer coating should not be less than 350 microns as per IS: 14177:1994 including compressor, paints, thinner, painting equipments, sand, labour, other machinery, scaffolding” etc
KAMAKSHI ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .