Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 34 618 ALINCHUVADU EDAPPALLY P O PADIVATTOM ERNAKULAM KERALA 682024 | ERNAKULAM | KERALA | 682024 | L1 | Accepted-AOC Negotiated Amount | |
| 2 | L2₹7.9 L+₹2.2 L (38.7%)Rejected-Finance KRISHNA SREYAS LANE CHERUPARAMBATH ROAD ELAMKULAM VILLAGE KADAVANTHRA ERNAKULAM ERNAKULAM KERALA 682020 | ERNAKULAM | KERALA | 682020 | L2 | Rejected-Finance L2 |
Tender Value
₹5.7 L
EMD Value
₹8,600
Closing Date
11 Oct 2021, 5:00 pmClosed
University Engineer
Engineering Unit, University of Kerala, Kariavattom Campus
AC Work
2021_KU_440678_1
UE/DB/ (e-GP)/E14/2021-2022
Open Tender
Electrical Works
Item Rate
30 days
PALAYAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,200
₹8,600
13 Dec 2021
20 Sept 2021
13 Oct 2021
20 Sept 2021
11 Oct 2021
20 Sept 2021
20 Sept 2021 - 11 Oct 2021
Amount
Air conditioning
od144256/2021_2022 : Supply, installation, testing and commissioning of 5.5 TR high energy efficient ducted split air conditioner unit (IDU) with inverter scroll compressor (ODU) suitable for continuous operation on 415 V, 3-phase, 50 Hz, AC supply with eco-friendly zero ODP R-410A as refrigerant gas and having features of long distance piping flexibility, wide angle air flow, high ambient temperature range, protection against DLT rise, oil shortage, HP / LP, single phasing / phase loss, over voltage / under voltage, overload / overcurrent, thermal protection for ODU fan motor, reverse rotation protection for inverter compressor, anti-corrosion condenser fin coating, touch screen controller with indications of compressor status, room temperature, ON / OFF timer, error indication and error reset and with necessary vibration isolation arrangement etc complete as per specification. Make:- Blue Star, Daikin, Voltas,Carrier,Mitsubuishi,Panasonic.
od144257/2021_2022 : Supply and providing adequate length of suitable sizes of superior quality hard drawn bright annealed copper refrigerant pipes (for suction and discharge) for connecting the refrigerant piping between ODU and IDU of the ducted AC unit including properly insulating the copper pipes with suitable size closed cell Class "O" elastomeric nitrile rubberized foam sleeve insulation and the joints sealed with self adhesive nitrile rubber insulation with proper mechanical fixing including brazing, pressure check, leak testing etc as required.
od144259/2021_2022 : Supplying and fixing 9 mm thick closed cell elastomeric Nitrile foam rubber having a density of 40-60 Kg/m³ (class "O") insulation on the existing Supply Air Duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation and having Microban certified anti-microbial protection complete as per specifications and as required.
od144261/2021_2022 : Supplying and providing flexible canvass connection for interconnecting IDU and Supply Air Ducts using suitable gauge fabricated at site GSS sheet metal rectangular / round ducting and fire retardant canvass cloth, secured to the galvanized sheet metal on either side by a double lock seam is inserted between the equipment / air duct & the ductwork to provide a wear resistant airtight flexible connection to eliminate vibrations, noise & rattles complete as required as per specifications.<br>
od144262/2021_2022 : Supply, fixing and testing of acoustic insulation for Supply Air Ducts using 10 mm thick open cell processed, fire retardant nitrile rubber having density of 140-180 kg/m³ after applying suitable adhesive for nitrile rubber and with Microban certified anti-microbial protection etc. complete as required and as per specifications.
od144263/2021_2022 : Supplying, fixing, testing and commissioning of Supply Air Diffusers of powder coated extruded aluminum etc as per specifications complete as required.
od144264/2021_2022 : Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications complete as required.
od144266/2021_2022 : Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications complete as required.
od144267/2021_2022 : Supply, conveyance, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.80 mm thick. (22 gauge)
od144268/2021_2022 : Supply, conveyance, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick. (24 gauge)
od144269/2021_2022 : Supply, installation, testing and commissioning of 1.5-Ton, 5-star rated, inverter type, wall mounting, high energy efficient, split air conditioner unit (IDU), fitted with hermetically sealed rotary compressor (ODU) suitable for eco-friendly and energy efficient refrigerant R-32A/R410A conforming to IS: 1391 Part-2 1992 (with latest amendments except power consumption norms) suitable for operation on 230 V, 50 Hz AC supply and capable of performing functions such as cooling, dehumidifying, air circulating, filtering etc and having features of long distance piping flexibility, wide angle air flow, IDU noise level < 43 dB (A) and ODU noise level < 56 dB (A) as per norms. The condensing and evaporating coils should be made of soft drawn bright annealed 100% copper tubes of suitable sizes and a standard length of upto 3 metres should be supplied with the AC unit and the copper pipes should be properly insulated with 10 mm thick closed cell Class 'O' elastomeric nitrile rubberised foam sleeve insulation. A standard length of upto 3 metres of suitable size ISI marked multi-core PVC insulated FRLS round flexible copper control cable for electrically connecting IDU and ODU of AC unit and microprocessor based wireless remote controller with required number of suitable batteries should be supplied along with the AC unit. Total 3 numbers of comprehensive free services should be provided for the AC unit (IDU & ODU) for the first one year, applicable from the date of commissioning. One year replacement warranty should be provided for the entire AC unit (IDU & ODU) along with two years exclusive warranty for PCB (make: Legrand, OBO betterman /MK India/ Clipsan )and nine years exclusive warranty for the compressor. Make: Carrier, Panasonic, Blue Star, Hitachi or Daikin.
od144270/2021_2022 : Supply, installation, testing and commissioning of wall mounting type 4 kVA voltage stabilizer with input voltage range of 170 V - 270 V and having features of high power efficiency, intelligent time delay system, Low & High voltage cut-off protection, built-in thermal overload protection, LED indications etc suitable for single phase 1/1.5-Ton air conditioner unit with three years warranty. Make: V-Guard, V-Stab, Pioneer or equivalent
od144271/2021_2022 : Supply and providing extra length of superior quality soft drawn bright annealed copper refrigerant pipes (suction and discharge) of suitable sizes for extending the refrigerant piping between ODU and IDU of the AC unit and properly insulating the copper pipes with 10 mm thick closed cell Class O elastomeric nitrile rubberised foam sleeve insulation and the joints sealed with black cotton tape with proper mechanical fixing including brazing, pressure check, leak testing etc as required.
od144272/2021_2022 : Supply and fixing good quality powder coated MS frames on wall (mounting brackets) using required numbers of suitable size anchor bolts for mounting the out door unit of AC in position complete with all accessories such as vibration isolating pads, hangers, railing etc as required.
90.6.5.19 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core2.50sqmm
90.6.5.20 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 4 core 4.50sqmm
90.10.3.23 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3pin plug top
MARETEK INDIA PVT LTD
Bidder Name
PERKINS REFRIGERATION AND AIR CONDITIONING
MARETEK INDIA PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_626820.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .