| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-Finance | ₹10.8 L | L1 | Accepted-Finance Due to having the lowest bidder |
| 2 | L2₹11.9 LRejected-Finance | ₹11.9 L | L2 | Rejected-Finance Due to not having the lowest bidder |
| 3 | L3₹13.8 LRejected-Finance 418 KALITALA PARK KOLKATA KOLKATA KOLKATA 700070 | 24 PARAGANAS SOUTH | WEST BENGAL | 700070 | ₹13.8 L | L3 | Rejected-Finance Due to not having the lowest bidder |
| 4 | L4₹14.0 LRejected-Finance ASHOKENAGAR NATNI BERABERY BERABERY 743711 | ASHOKENAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743711 | ₹14.0 L | L4 | Rejected-Finance Due to not having the lowest bidder |
| Sl No | Description | Qty | Unit | GHOSH ENGINEERING L3 | K. P. CONSTRUCTION L4 | M/S T.D.ELECTRIC L1 | PRIYA ELECTRIC L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Survey of cable route as per instruction of site Engineer | 844 | MTR | 2 ₹1,688 | 2 ₹1,688 | 0.5 ₹422 | 2.65 ₹2,236.60 |
| 2.00 | Fixing of Pin Insulator 11KV | 36 | NOS | 72 ₹2,592 | 105 ₹3,780 | 63 ₹2,268 | 65 ₹2,340 |
| 3.00 | Microtunnelling work with laying of HDPE pipe as per instruction of site Engineer and as per site condition including supply of HDPE pipe as per IS 4984: 1995 including preparation and submission of As built drawing with 160mm Dia HODPE pipe, PE 80, PN-6 | 844 | MTR | 1,320 ₹11.1 L | 1,270 ₹10.7 L | 1,050 ₹8.9 L | 1,142 ₹9.6 L |
| 4.00 | Excavation of soil for formation of trial hole having minimum size 1.1x0.5x1.2 M in total cable route as per specification and direction of the site Engineer | 20 | Cum | 48 ₹960 | 67 ₹1,340 | 150 ₹3,000 | 31 ₹620 |
| 5.00Excavation of soil (METAL ASPHALT NORMAL SOIL) for formation of cable trench and reinstatement of the cable trench with the excavated soil after completion of laying and dressing of 1 nos 11KV 3x300 SQMM XLPE UG cable and cable protection work as per specification and direction of the site Engineer. Size of cable trench should be at least 900x500 mm and the depth must not be less than 900 mm with 75 mm sand level at the base filling the space between cable and bricks with yellow sand and protection on sIdes and top by 24 Nos good quality bricks per meter and the rest space should be filled up with excavated soil as per specification and direction of the site Engineer. | |||||||
| 5.10 | Excavation of soil | 25 | Cum | 47 ₹1,175 | 78 ₹1,950 | 150 ₹3,750 | 130 ₹3,250 |
| 5.20 | Supply of kiln burnt brick | 1,296 | NOS | 10 ₹12,960 | 13 ₹16,848 | 8.1 ₹10,497.60 | 8 ₹10,368 |
| 5.30 | Laying of bricks | 1,296 | NOS | 1 ₹1,296 | 2 ₹2,592 | 0.25 ₹324 | 1 ₹1,296 |
| 5.40 | Laying And Dressing Of 01 Nos Cable 12KV Gr. 3CX300 Sqmm XLPE Cable In Excavated/Pucca Trench/HDPE pipe | 975 | MTR | 62 ₹60,450 | 90 ₹87,750 | 52 ₹50,700 | 56 ₹54,600 |
| 6.00 | Arrangement for termination joint/St Joint Jointing kit for end termination joint will be supplied by WBSEDCL and the work of jointing will be done by WBSEDCL's own personnel or other agency But necessary arrangements for properly covering top and all sides of jointing pits with tarpaulin/ Polythene sheet has to be made at the time of jointing. Also required manpower is to be provided to help the cable jointer for straightening the cable at the joint location and re-arrangement of cable loops until completion of jointing and necessary lighting arrangement is to be done if required | 6 | MTR | 1,000 ₹6,000 | 1,400 ₹8,400 | 1,600 ₹9,600 | 2,000 ₹12,000 |
Tender Value
₹11.9 L
EMD Value
₹23,885
Closing Date
13 Mar 2026, 3:00 pmClosed
Divisional Manager
Administrative Building Vivek Nagar B T Road P S Khardah District North 24 Parganas Pin 700119
Augmentation of existing 3CX185sqmm XLPE UG cables by 3CX300sqmm XLPE UG Cables i r o Madhyamgram Sodepur New Barrackpore 11KV feeders under Sajirhat Substation under Barrackpore Division
2026_WBSED_1015418_1
DM/BKPD/TECH/NIT/2025-26/22
Open Tender
MISC ELECTRICAL WORKS
30 days
Sajirhat Sub-Station
Please refer Tender documents
2 documents required · 2 mandatory
₹0
₹23,885
27 May 2026
5 Mar 2026
16 Mar 2026
5 Mar 2026
13 Mar 2026
5 Mar 2026
Survey of cable route as per instruction of site Engineer
Fixing of Pin Insulator 11KV
Microtunnelling work with laying of HDPE pipe as per instruction of site Engineer and as per site condition including supply of HDPE pipe as per IS 4984: 1995 including preparation and submission of As built drawing with 160mm Dia HODPE pipe, PE 80, PN-6
Excavation of soil for formation of trial hole having minimum size 1.1x0.5x1.2 M in total cable route as per specification and direction of the site Engineer
Excavation of soil (METAL ASPHALT NORMAL SOIL) for formation of cable trench and reinstatement of the cable trench with the excavated soil after completion of laying and dressing of 1 nos 11KV 3x300 SQMM XLPE UG cable and cable protection work as per specification and direction of the site Engineer. Size of cable trench should be at least 900x500 mm and the depth must not be less than 900 mm with 75 mm sand level at the base filling the space between cable and bricks with yellow sand and protection on sIdes and top by 24 Nos good quality bricks per meter and the rest space should be filled up with excavated soil as per specification and direction of the site Engineer.
Excavation of soil
Supply of kiln burnt brick
Laying of bricks
Laying And Dressing Of 01 Nos Cable 12KV Gr. 3CX300 Sqmm XLPE Cable In Excavated/Pucca Trench/HDPE pipe
Arrangement for termination joint/St Joint Jointing kit for end termination joint will be supplied by WBSEDCL and the work of jointing will be done by WBSEDCL's own personnel or other agency But necessary arrangements for properly covering top and all sides of jointing pits with tarpaulin/ Polythene sheet has to be made at the time of jointing. Also required manpower is to be provided to help the cable jointer for straightening the cable at the joint location and re-arrangement of cable loops until completion of jointing and necessary lighting arrangement is to be done if required
Making of Straight through joint for cable 3X300sq.mm
Protective duct for cable joint complete as per WBSEDCL approved drawing
Supply & fixing of GI pipe as per ISI of the 150MM dia for cable protection as per instruction of site engineer
Earthing Complete
Installation of 12 KV class gapless LA on the cable termination DP including earthing with G.I.Pipe
Supply and installation cable marker
Supply and installation of Cable Tag
Supply and installation of 11KV ST THR. HS JNT.FOR3x300SMM XLPE CABLE
Supply and installation of 11KVO/D HS Ter.Jnt.FOR3x300SMM XLPE CABLE
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 14.87 MB
BOQ_2494399.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid