AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR AND MAINT OF VRV-III AC PLANT LOCATED IN (NTC BLOCK 1 AND 2) AT DEFENCE LAB JODHPUR
2024_MES_673095_2
8608/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹15,000
Yes
10 Mar 2025
28 Dec 2024
28 Jan 2025
28 Dec 2024
26 Jan 2025
7 Jan 2025
30 Dec 2024 - 6 Jan 2025
Amount
M&L for servicing of Daikin VRF-III including (outdoor and indoor) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge.
Supply and charging of gas R- 410A inside the compressor and testing Complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Remote controller for indoor unit as per sample Complete all as specified and as directed by Engr-in-Charge.
S&F in repair of Printed Circuit Board for indoor unit of any capacity and any type including all connected wiring, connectors, adopter etc required at site complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Printed Circuit Board for indoor unit of any capacity and any type including all connected wiring, connectors, adopter etc required at site complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of inverter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Noise filter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Main control PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Power/ Over Voltage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Fan driver PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Reverse phase PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of earth leakage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Magnetic contactor for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Fan motor for outdoor unit any capacity complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Sheet metal encloseure with 3 pin plug and socket with 20 Amp MCB single pole. Complete all as specified and as directed by Engr-in-Charge.
S&F in sheet metal encloseure suitable for TPN MCB including 63 amp TPN MCB fixed on wall including necessary connections in the existing cable with gland all. Complete all as specified and as directed by Engr-in-Charge.
S&F MCB SP 6 - 32 Amps 230 V including taking down old UNSV MCB Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing MCCB 4 pole 200 Amp rotary type 415 volt breaking capacity 36 KA including spreader, phase barrier, rotary handle and taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge
S&F MCCB 4 pole 415 volts 160 Amp rotary type breaking capacity 36 KA including spreader, rotary handle, phase barrier including taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge .
Supply and Fixing in replacement Scroll Fix Compressor for outdoor of any capacity as per existing size and model complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement inverter Compressor for outdoor of any capacity as per existing size and model complete all as specified and directed by Engineer-in-charge.
Note : (i) The tenderer shall have to replace the U/s material with OEM material only. (ii) In case any accident occur of any Indl like Mechanic/Helper during maintenanc of above mentioned Airconditioner/unit, contractor is liable to pay compensation to the Indl as decided by the competent authority. Department will not be responsible for the same. (iii) If complaint is not attended by contractor with in five hour the penality of Rs 1000/ per hour to be imposed and amount of penality will be deducted from RAR. (iv) The cost of all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site, no extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE every day as a token of complaint attended. (vi) Electrician for Electric related issues in VRV system including connected LT panels/circuits provided by contractor.
Shree Karni Construction (BID ID -3220280)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .