Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.7 LAccepted-Finance | 1 | Accepted-Finance 1 | |
| 2 | 2₹10.8 L+₹4,417.52 (0.41%)Rejected-Finance | 2 | Rejected-Finance EMD refund |
| Sl No | Description | Qty | Unit | AAYUSH ELECTRICALS L1 | SANJAY KUMAR SHRIVASTAVA L2 |
|---|---|---|---|---|---|
| 1.00Item | |||||
| 2.00 | Supply Aand Fixing of Pressure Switch 11 TonDX For HVAC System | 16 | NOS | 22,064 ₹22,064 Lowest | 22,076.64 ₹22,076.64 |
| 3.00 | Supply And Fixing AHU 20,000 CFM Filters(610X610mm) | 8 | NOS | 51,220 ₹51,220 Lowest | 51,732.16 ₹51,732.16 |
| 4.00 | Supply And Fixing AHU 20,000 CFM Filter(610x300mm) | 4 | NOS | 25,610 ₹25,610 Lowest | 25,866.08 ₹25,866.08 |
| 5.00 | Supply Fixing Testing and Commissioning of HVAC scrool Compressor of 11 ton, Refrigerant R22,3 Phase, Frequency 50/60 HZ, Voltage 380-415 | 7 | NOS | 4,48,000 ₹4,48,000 Lowest | 6,86,000 ₹6,86,000 |
| 6.00 | Supply and Fixing of Outdoor Motar, Voltage 400V/50 Hz, Phase 3 Phase, 750-900rpm.Suitable for 11ton HVAC System | 7 | NOS | 44,817.5 ₹44,817.5 Lowest | 45,265.64 ₹45,265.64 |
| 7.00 | Supply and Fixing 18 inchs, 3 fin Fan Blade, Number of Blades 3, Usage/Application Industrial/Commertial Fan | 5 | NOS | 8,865 ₹8,865 Lowest | 8,953.65 ₹8,953.65 |
| 8.00 | Supply and fixing of Switch Magnet suitable for mounting in outdoor unit 11 ton DX machine | 5 | NOS | 13,568.35 ₹13,568.35 Lowest | 13,704 ₹13,704 |
| 9.00 | Supply and Fixing of Expansion valve Body material-Brass, Connection material -Copper, Refrigerants-R22 | 5 | NOS | 62,409.6 ₹62,409.6 Lowest | 63,033.65 ₹63,033.65 |
| 10.00 | Supply and Fixing of Contractor Rated Current- 32 Amp, Rated Power-15 kW at 415 V AC, | 4 | NOS | 14,972 ₹14,972 Lowest | 15,121.72 ₹15,121.72 |
Tender Value
Refer Docs
EMD Value
₹8,193
Closing Date
19 May 2025, 5:30 pmClosed
EE Light JMC
EE Light JMC
Maintanance of Manas Bhawan HVAC System
2025_UAD_421182_1
Light/2025-26/PRO/37
Open Tender
Support/Maintenance Service
Item Rate
180 days
Jabalpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹8,193
26 Aug 2025
5 May 2025
22 May 2025
5 May 2025
19 May 2025
10 May 2025
Supply Aand Fixing of Pressure Switch 11 TonDX For HVAC System
Supply And Fixing AHU 20,000 CFM Filters(610X610mm)
Supply And Fixing AHU 20,000 CFM Filter(610x300mm)
Supply Fixing Testing and Commissioning of HVAC scrool Compressor of 11 ton, Refrigerant R22,3 Phase, Frequency 50/60 HZ, Voltage 380-415
Supply and Fixing of Outdoor Motar, Voltage 400V/50 Hz, Phase 3 Phase, 750-900rpm.Suitable for 11ton HVAC System
Supply and Fixing 18 inchs, 3 fin Fan Blade, Number of Blades 3, Usage/Application Industrial/Commertial Fan
Supply and fixing of Switch Magnet suitable for mounting in outdoor unit 11 ton DX machine
Supply and Fixing of Expansion valve Body material-Brass, Connection material -Copper, Refrigerants-R22
Supply and Fixing of Contractor Rated Current- 32 Amp, Rated Power-15 kW at 415 V AC,
Condensing Coil Repair
upplying and Filling of r-22 Gas
Flexible connections Providing & fixing of flexible canvas connectionbetween indoor unit andduct to avoid the vibration transfer (Size 900x900mm)
Copper piping: Supply, installation, testing and commissioning of interconnecting copper refrigerant pipework (19mm /13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lagcoating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3mm thick complete as per specification. 28.6mm O.D.wall thickness ≥ 1.2mm (insulation 19 mm thick)
Copper piping: Supply, installation, testing and commissioning of interconnecting copper refrigerant pipework (19mm /13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lagcoating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3mm thick complete as per specification. 22.2mmO.D.wall thickness ≥ 1.0mm (insulation 19 mm thick)
Duct Leakage Repairring
AHU Repairing Blower+Motar
Nitrogen Testing with nitrogen gas at 500 psi and Vaccume 400 micron, Copper Line Connected AHU With Outdoor
Chemical servicing:- ofwindow/split air conditioning unit 11TR capacity including cleaning of cooling & condensing units, filters, grills etc & all other part soiling & greasing off anmotor, testing of A.C unit etc.
SANJAY KUMAR SHRIVASTAVA (BID ID -1256787)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .