Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹49.7 L+₹3.3 L (7.14%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹50.1 L+₹3.7 L (7.95%)Rejected-Finance AKASHGANGA SUKANTA MARG MONIRAMPORE BARRACKPORE WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹50.3 L+₹3.9 L (8.47%)Rejected-Finance RAMAKRISHNA COLONY PO MAJHIPARA DIST 24 PARGANAS NORTH PIN 743145 STATE WEST BENGAL | 24 PARAGANAS NORTH | WEST BENGAL | 743145 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹51.0 L+₹4.6 L (9.81%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹47.6 L
EMD Value
₹95,300
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIRS TO BLDG NO. OLD-3 AT RCTC OTM ACCN UNDER GE BARRACKPORE
2022_MES_547385_2
8698/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹95,300
Yes
22 Oct 2022
29 Sept 2022
15 Oct 2022
29 Sept 2022
13 Oct 2022
8 Oct 2022
Amount
PART-I Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
S&F for compound girders and stanchions, lattice girders, areial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset paltes etc complete all as specified and directed.
S&F of erection and fixing in any position of steel frame work including flat iron MS plates etc in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St-240 including one shop coat of zinc chromate primer paint (including preparation of surfaces) at contractors worksop before fabrication complete all as specified and directed
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 25mm (avg) thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof padding / levelling course complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions including 20mm thick screed bed in cement mortar (1:4) on concrete surface of roof as levelling course mixed with WPC @200ml/50Kg of cement or as per manufacturer instructions complete all as specified and directed. (Note: WPC shall be measured and paid separately under relevant item)
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frames) not exceeding 1.50 Sqm complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed.
Taking down of shutter of any description not exceeding 1 Sqm each complete all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and refixing in same opening after easing and adjusting completed all as specified and directed.
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
S&F of 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F of 35mm thick (factory made) second class hard wood glazed/ gauge & skeleton shutters for door & windows, open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing divided into square with plain, chamfered or rounded, fitted with cut & mitered rebated sash bars, any numbers for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section-8, Clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F of 35mm thick (factory made) second class hard wood glazed/ gauge & skeleton shutters for door & windows, open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing divided into square with plain, chamfered or rounded, fitted with cut & mitered rebated sash bars, any numbers for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section-8, Clause 8.24 (b) (larger size to be provided) complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in window and door shutter complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) used as in brick or concrete wall surfaces complete all as specified and directed.
S&F of mild steel hold fast made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in old window and door complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane including hacking out old brorken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 3mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
S&F for 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in flooring finish the surface even and smooth without using extra cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 25mm thick screed bed of cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10mm cement plastering in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable pipe complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F in repairs of 20mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc complete all as specified and directed.
S&F of aluminium bracket (heavy duty), powder coated of best quality as approved suitable for fixing 20mm bore curtain rod fixed in wall complete all as specified and directed.
M&L for 50mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & paving including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions, finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for applying two coats of acrylic antifungal exterior emulsion paint over a coat of acrylic primer on newly pastered wall surfaces as directed as per site condition after preparation of surfaces complete all as specified and directed .
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick putty on ceiling surfaces after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint over a coat of acrylic primer on old pastered wall surfaces as directed as per site condition after complete removal of existing paint and preparation of surfaces complete all as specified and directed .
Dismantling boarding any description fixed in any position with screw complete all as specified and directed.
M&L for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminum frame work for cupboard shutter complete all as specified and directed.
S&F in repairs of continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 40mm complete all as specified and directed.
S&F of 40 mm dia cupboard knobs fixed with nut, screw and washer of brass bright finished complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred, sopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part there of over or under 30 cm complete all as specified and directd. (Note: For adjustment purpose only)
S&F of 300mm mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
PART-II Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.74.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
Ditto-all as per Item No.74.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4.0 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 5 pin, 16 Amps socket outlet on independent board complete all as specified and directed .
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F of red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 6 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable DB complete all as specified and as directed.
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat including taking down old unserviceable DB complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, four pole, 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete as in repair all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed . Note: (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
S&F in repairs of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after and including taking down of unserviceable one complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unservicebale earthing complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
S&F of ceiling fan with blades, down rods and all accessories, 230 volts, 1400 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) type and including hanging GI hook with necessary suitable MS clamp and connecting cable three core, 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed.
M&L for galvanized iron tubing 40mm dia (medium grade) in any length including embedded in wall two ends duly welded MS holdfast at two ends of GI pipe and providing PCC in wall and making good disturbed surfaces including taking down old unserviceable tubing complete all as specified and directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down existing cable of any type and any size complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable one complete all as specified and directed.
S&F of 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable including taking down old unserviceable one complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
BEE ROMEN
SREE GURU CONSTRUCTION CO
R.S. COMPANY
BHASKAR SUPPLY AGENCY
N C DUTTA
FALCONS INDIA
M/S. ARUP KUMAR DEY
K. K. CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .