Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 110 SADAR BAZAR JHANSI RAJESH BHANDARI 110 SADAR BAZAAR JHANSI SADAR BAZAR JHANSI UTTAR PRADESH 284001 | JHANSI | UTTAR PRADESH | 284001 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
16 Jul 2022, 6:00 pmClosed
AGM-Electrical Main Campus
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
Empanelment of agencies for Annual rates of Electrical and ELV allied Maintenance works at IIM Ahmedabad Campus (Main and New Campus)
2022_IIMA_697577_1
IIMA/Contracts/TW-014/2022-23
Open Tender
Electrical Works
Item Rate
365 days
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10,000
Yes
INDIAN INSTITUTE OF MANAGEMENT AHMEDABAD
29 Jul 2022
28 Jun 2022
18 Jul 2022
28 Jun 2022
16 Jul 2022
6 Jul 2022
28 Jun 2022 - 4 Jul 2022
4 Jul 2022
Amount
SITC of Wiring (Non Modular Type Switch Accessories)
SITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
a)SITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
b)SITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
SITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
SITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch and power saver regulator , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of 5A ON Board Point
SITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - Average Length-3 Mtr Above length measure in Running Mains)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire 4.0 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti Average Length-3 Mtr Above length measure in Running Mains)
SITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of Wiring Modular Type Switch Accessories with Conceal/Close Wiring
SITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
a)SITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
b)SITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
SITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
SITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch and power saver regulator , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of 5A ON Board Point
SITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - Average Length-3 Mtr Above length measure in Running Mains)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire 4.0 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti Average Length-3 Mtr Above length measure in Running Mains)
SITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of Dummy/Blank Point
SITC of Wiring Modular Type Switch Accessories with Open Wiring
a)SITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
b)SITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
SITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
SITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
SITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch and power saver regulator , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
SITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of 5A ON Board Point
SITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
SITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - Average Length-3 Mtr Above length measure in Running Mains)
SITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire 4.0 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti Average Length-3 Mtr Above length measure in Running Mains)
SITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
SITC of Mains Wiring (Without Pipe/Patti)
SITC of 1.5 sqmm Single Phase Mains (3.nos 1.5 sqmm wire P+N+E)
SITC of 2.5 sqmm Single Phase Mains (2.nos 2.5 sqmm wire for (P+N) + 1.nos 1.5 sqmm wire for (E)
SITC of 2.5 sqmm Three Phase Mains (4.nos 2.5 sqmm wire for (R+Y+B+N) + 1.nos 1.5 sqmm wire for (E)
SITC of 4.0 sqmm Single Phase Mains (2.nos 4.0 sqmm wire for (P+N) + 1.nos 2.5 sqmm wire for (E)
SITC of 4.0 sqmm Three Phase Mains (4.nos 4.0sqmm wire for (R+Y+B+N) + 1.nos 2.5sqmm wire for (E)
SITC of 6.0 sqmm Single Phase Mains (2.nos 6.0 sqmm wire for (P+N) + 1.nos 4.0 sqmm wire for (E)
SITC of 6.0 sqmm Three Phase Mains (4.nos 6.0sqmm wire for (R+Y+B+N) + 1.nos 2.5sqmm wire for (E)
SITC of TV Cable (RG-6)
SITC of 2 Pair Telephone Wire
SITC of CAT-6 UTP Cable(Without Pipe)
SITC of CAT-6 UTP Cable (With 32mm HDPE Pipe)
SITC of CAT-6A UTP Cable(Without Pipe)
SITC of CAT-6A UTP Cable (With 32mm HDPE Pipe)
SITC of CAT-6 UTP Armoured Cable (Without Pipe)
SITC of CAT-6 UTP Armoured Cable (With 32mm HDPE Pipe)
SITC of PVC Pipe /Casing Caping Patti including all accessories(Coupler, Elbow, Band, Tee, End Cap ,4-way)
SITC of 20mm PVC CASSING Patti
SITC of 20mm MMS PVC Pipe
SITC of 25mm PVC CASSING Patti
SITC of 25mm MMS PVC Pipe
SITC of PVC Trunking Raceway including all accessories(Coupler, Elbow, Band, Tee, End Cap,4-way)
SITC of 38 x 16mm PVC Trunking Raceway
SITC of 38 x 25mm PVC Trunking Raceway
SITC of 38 x 38mm PVC Trunking Raceway
SITC of 25 x 16mm PVC Trunking Raceway
SITC of 50 x 50mm PVC Trunking Raceway
SITC of 100 x 50mm PVC Trunking Raceway
SITC of 75 x 50mm PVC Trunking Raceway
ITC of Wiring - Non Modular Type Switch Accessories
ITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
ITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
ITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
ITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch and power saver regulator , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of 5A ON Board Point
ITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - Average Length-3 Mtr Above length measure in Running Mains)
ITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire 4.0 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti Average Length-3 Mtr Above length measure in Running Mains)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of Wiring Modular Type Switch Accessories with Conceal/Close Wiring
a)ITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
b)ITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
ITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
ITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
ITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , Power Saver Regulator-2M with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of 5A ON Board Point
ITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - Average Length-3 Mtr Above length measure in Running Mains)
ITC of 25A DP MCB With PVC Double Pole MCB Box for AC Point Point, Mains Wire 4.0 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti Average Length-3 Mtr Above length measure in Running Mains)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of Dummy/Blank Point
ITC of Wiring Modular Type Switch Accessories with Open Wiring
ITC of Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
a)ITC of Secondary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
b)ITC of Primary Light Point with 1.5 sqmm wire (Phase) with individual phase from switch, and remaining Neutral & earth need to be loop from nearest light & fan point. with 25mm PVC Pipe or 25mm Casing Caping Patti , 6A One Way Switch (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Secondary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti (Average Length-3 Mtr Above length measure in Running Mains)
ITC of Two way Primary Light Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 6A Two Way Switch , Box , Plate (Average Length-7 Mtr Above length measure in Running Mains)
ITC of Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , Power Saver Regulator-2M with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Bell Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , 1M 6A Bell Push Switch ,Box, Plate (Average Length-5 Mtr Above length measure in Running Mains) (Without Bell Buzzer)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains)
ITC of Exhaust Fan Point with 1.5 sqmm wire (P+N+E) & 25mm PVC Pipe or 25mm Casing Caping Patti , with 6A Switch , Box , Plate (Average Length-5 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of 5A ON Board Point
ITC of 1.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 3.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 4.Nos of 5A Power Point Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 1.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 2.5 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of 2.Nos of 15A Power Point for Freezer, Geyser, Oven etc. Including Switch, Socket , Box & Plate (Without Mains Wire- 4 Sqmm (P+N+E) & 25mm PVC Pipe / Casing Caping Patti)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 4 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of AC/Geyser Point Including Switch, Socket , Box & Plate ,Mains Wire- 2.5 Sqmm (P+N+1.5sqmm E) & 25mm PVC Pipe / Casing Caping Patti - (Average Length-3 Mtr Above length measure in Running Mains) (Socket & Switch are at different Location)
ITC of Telephone Point Including Telephone Jack , Box & Plate (Without 2-pair Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O), Box & Plate (Without CAT-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Lan Point Including Data Jack (I/O) , Box & Plate (Without CAT-6A Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of TV Point Including TV Socket , Box & Plate (Without RG-6 Wire & 25mm PVC Pipe / Casing Caping Patti)
ITC of Dummy/Blank Point
ITC of Mains Wiring (Without Pipe/Patti)
ITC of 1.5 sqmm Single Phase Mains (3.nos 1.5 sqmm wire P+N+E)
ITC of 2.5 sqmm Single Phase Mains (2.nos 2.5 sqmm wire for (P+N) + 1.nos 1.5 sqmm wire for (E)
ITC of 2.5 sqmm Three Phase Mains (10.nos 2.5 sqmm wire for (R+Y+B+N) + 1.nos 1.5 sqmm wire for (E)
ITC of 10.0 sqmm Single Phase Mains (2.nos 10.0 sqmm wire for (P+N) + 1.nos 2.5 sqmm wire for (E)
ITC of 10.0 sqmm Three Phase Mains (10.nos 10.0sqmm wire for (R+Y+B+N) + 1.nos 2.5sqmm wire for (E)
ITC of 6.0 sqmm Single Phase Mains (2.nos 6.0 sqmm wire for (P+N) + 1.nos 10.0 sqmm wire for (E)
ITC of 6.0 sqmm Three Phase Mains (10.nos 6.0sqmm wire for (R+Y+B+N) + 1.nos 2.5sqmm wire for (E)
ITC of TV Cable (RG-6)
ITC of 2 Pair Telephone Wire
ITC of CAT-6 UTP Cable(Without Pipe)
ITC of CAT-6 UTP Cable (With 32mm HDPE Pipe)
ITC of CAT-6A UTP Cable(Without Pipe)
ITC of CAT-6A UTP Cable (With 32mm HDPE Pipe)
ITC of CAT-6 UTP Armoured Cable (Without Pipe)
ITC of CAT-6 UTP Armoured Cable (With 32mm HDPE Pipe)
ITC of Mains Wiring (Without Pipe/Patti)
ITC of 20mm PVC CASSING Patti
ITC of 20mm MMS PVC Pipe
ITC of 25mm PVC CASSING Patti
ITC of 25mm MMS PVC Pipe
ITC of Light Fixture & Fans (Light Fixture & Fans Provide By IIMA)
ITC of Tubelight Fixture
ITC of 18/20/28/36W Surface/Recess Downlight
ITC of 1200mm Ceiling Fan
ITC of 900mm Ceiling Fan
ITC of 300mm PVC/Metal Exhaust Fan
ITC of 200mm PVC/Metal Exhaust Fan
ITC of Bell Buzzer
ITC of Milky Dom Light
SITC Rate - DBs & MCBs
6 Way TPN DB
8 Way TPN DB
12 Way TPN DB
6 Way SPN DB
8 Way SPN DB
12 Way SPN DB
Metal Box for DP MCB
Metal Box for FP/TPN MCB
6 to 32 A SP MCB
6 to 32 A DP MCB
6 to 32 A TP MCB
6 to 32 A FP MCB
40 to 63A FP MCB
40 to 63A DP MCB
80A TPN MCB
100A TPN MCB
40 to 63A FP Isolator
18"(W) x 36"(H) x 8"(D) TPN DB Enclosure Box with door (IP 42) - Metal Body
ITC Rate - DBs & MCBs- (Material Supplied by IIMA)
6 Way TPN DB
8 Way TPN DB
12 Way TPN DB
6 Way SPN DB
8 Way SPN DB
12 Way SPN DB
Metal Box for DP MCB
Metal Box for FP/TPN MCB
6 to 32 A SP MCB
6 to 32 A DP MCB
6 to 32 A TP MCB
6 to 32 A FP MCB
40 to 63A FP MCB
40 to 63A DP MCB
80A TPN MCB
100A TPN MCB
40 to 63A FP Isolator
ITC - Switch Accessories (Non-Modular Type) (Material Provide by IIMA)
6A One Way Switch
6A Socket
16A One Way Switch
16A Socket
6A Two Way Switch
6A Bell Push Switch
Fan Regulator (100W- 1 Modules) - Humming Free
Fan Regulator (100W- 2 Modules)
6A Switch socket Combined
16A Switch socket Combined
Telephone Jack (RJ-11) 1-Modul
TV Socket 1-Modul
Data Jack (RJ-45) 1-Modul
Wooden Plat for Switch Board With Suitable Wooden Box
Wooden Plat for Switch Board
Only Labour Rate -Switch Accessories (Modular Type) (Material Provide by IIMA)
6A One Way Switch
6A Socket
16A One Way Switch (With Light)
16A Socket
20/25A One Way Switch(With Light)
20/25A Socket
6A Two Way Switch
6A Bell Push Switch
Fan Regulator (100/250W- 1 Modules) - Humming Free
Fan Regulator (100/250W- 2 Modules)
Telephone Jack (RJ-11) 1-Module
TV Socket 1-Module
Data Jack (RJ-45) 1-Module
Dummy Switch Blank Plate
1 or 2 Module Plate
3 Module Plate
4 Module Plate
6 Module Plate
8 Module Plate
12 Module Plate
1 or 2 Module Conceal MS Box
3 Module Conceal MS Box
4 Module Conceal MS Box
6 Module Conceal MS Box
8 Module Conceal MS Box
12 Module Conceal MS Box
1 or 2 Module Surface Mounted
3 Module Surface Mounted
4 Module Surface Mounted
6 Module Surface Mounted
8 Module Surface Mounted
12 Module Surface Mounted
SITC of different size of cables including clamping of cable (wall, tray, surface, etc. and AL cable tags on both end)
300 sqmm X 3.5Core AL Arm Cable
240 sqmm X 3.5Core AL Arm Cable
185 sqmm X 3.5Core AL Arm Cable
150 sqmm X 3.5Core AL Arm Cable
120 sqmm X 3.5Core AL Arm Cable
95 sqmm X 3.5Core AL Arm Cable
70 sqmm X 3.5Core AL Arm Cable
50 sqmm X 3.5Core AL Arm Cable
35 sqmm X 3.5Core AL Arm Cable
25 sqmm X 3.5Core AL Arm Cable
95 sqmm X 3.5Core CU Arm Cable
70 sqmm X 3.5Core CU Arm Cable
50 sqmm X 3.5Core CU Arm Cable
35 sqmm X 3.5Core CU Arm Cable
120 sqmm X 3.5Core CU Arm Cable
25 sqmm X 4 Core CU Arm Cable
16 sqmm X 4 Core CU Arm Cable
16 sqmm X 3 Core CU Arm Cable
10 sqmm X 4 Core CU Arm Cable
10 sqmm X 3 Core CU Arm Cable
6 sqmm X 4 Core CU Arm Cable
6 sqmm X 3 Core CU Arm Cable
4 sqmm X 4 Core CU Arm Cable
4 sqmm X 3 Core CU Arm Cable
2.5 sqmm X 4 Core CU Arm Cable
2.5 sqmm X 3 Core CU Arm Cable
1.5 sqmm X 4 Core CU Arm Cable
1.5 sqmm X 3 Core CU Arm Cable
ITC of different size of cables including clamping of cable (wall,tray,surface,etc.. and AL cable tags on both end)
300 sqmm X 3.5Core AL Arm Cable
240 sqmm X 3.5Core AL Arm Cable
185 sqmm X 3.5Core AL Arm Cable
150 sqmm X 3.5Core AL Arm Cable
120 sqmm X 3.5Core AL Arm Cable
95 sqmm X 3.5Core AL Arm Cable
70 sqmm X 3.5Core AL Arm Cable
50 sqmm X 3.5Core AL Arm Cable
35 sqmm X 3.5Core AL Arm Cable
25 sqmm X 3.5Core AL Arm Cable
95 sqmm X 3.5Core CU Arm Cable
70 sqmm X 3.5Core CU Arm Cable
50 sqmm X 3.5Core CU Arm Cable
35 sqmm X 3.5Core CU Arm Cable
120 sqmm X 3.5Core CU Arm Cable
25 sqmm X 4 Core CU Arm Cable
16 sqmm X 4 Core CU Arm Cable
16 sqmm X 3 Core CU Arm Cable
10 sqmm X 4 Core CU Arm Cable
10 sqmm X 3 Core CU Arm Cable
6 sqmm X 4 Core CU Arm Cable
6 sqmm X 3 Core CU Arm Cable
4 sqmm X 4 Core CU Arm Cable
4 sqmm X 3 Core CU Arm Cable
2.5 sqmm X 4 Core CU Arm Cable
2.5 sqmm X 3 Core CU Arm Cable
1.5 sqmm X 4 Core CU Arm Cable
1.5 sqmm X 3 Core CU Arm Cable
SITC of Under Ground Cables Excavation and refill the surface as it is
Depth of Excavation -1.5 Feet x 1 Feet (Including sand & Brick/Half Hume Pipe Filling )
Depth of Excavation - 2 Feet x 1 Feet (Including sand & Brick/Half Hume Pipe Filling )
Depth of Excavation - 3 Feet x 1 Feet (Including sand & Brick/Half Hume Pipe Filling )
100mm Half Round RCC Hume Pipe
150mm Half Round RCC Hume Pipe
200mm Half Round RCC Hume Pipe
Sand & Brick/Half Hume Pipe Filling
SITC of Cables Termination with Double compression Cable Gland & relevant Lugs
300 sqmm X 3.5Core AL Arm Cable Termination
240 sqmm X 3.5Core AL Arm Cable Termination
185 sqmm X 3.5Core AL Arm Cable Termination
150 sqmm X 3.5Core AL Arm Cable Termination
120 sqmm X 3.5Core AL Arm Cable Termination
95 sqmm X 3.5Core AL Arm Cable Termination
70 sqmm X 3.5Core AL Arm Cable Termination
50 sqmm X 3.5Core AL Arm Cable Termination
35 sqmm X 3.5Core AL Arm Cable Termination
25 sqmm X 3.5Core AL Arm Cable Termination
95 sqmm X 3.5Core CU Arm Cable Termination
70 sqmm X 3.5Core CU Arm Cable Termination
50 sqmm X 3.5Core CU Arm Cable Termination
35 sqmm X 3.5Core CU Arm Cable Termination
120 sqmm X 3.5Core CU Arm Cable Termination
25 sqmm X 4 Core CU Arm Cable Termination
16 sqmm X 4 Core CU Arm Cable Termination
16 sqmm X 3 Core CU Arm Cable Termination
10 sqmm X 4 Core CU Arm Cable Termination
10 sqmm X 3 Core CU Arm Cable Termination
6 sqmm X 4 Core CU Arm Cable Termination
6 sqmm X 3 Core CU Arm Cable Termination
4 sqmm X 4 Core CU Arm Cable Termination
4 sqmm X 3 Core CU Arm Cable Termination
2.5 sqmm X 4 Core CU Arm Cable Termination
2.5 sqmm X 3 Core CU Arm Cable Termination
1.5 sqmm X 4 Core CU Arm Cable Termination
1.5 sqmm X 3 Core CU Arm Cable Termination
ITC of Cables Termination with Double compression Cable Gland & relevant Lugs (Material Provided by IIMA)
300 sqmm X 3.5Core AL Arm Cable Termination
240 sqmm X 3.5Core AL Arm Cable Termination
185 sqmm X 3.5Core AL Arm Cable Termination
150 sqmm X 3.5Core AL Arm Cable Termination
120 sqmm X 3.5Core AL Arm Cable Termination
95 sqmm X 3.5Core AL Arm Cable Termination
70 sqmm X 3.5Core AL Arm Cable Termination
50 sqmm X 3.5Core AL Arm Cable Termination
35 sqmm X 3.5Core AL Arm Cable Termination
25 sqmm X 3.5Core AL Arm Cable Termination
95 sqmm X 3.5Core CU Arm Cable Termination
70 sqmm X 3.5Core CU Arm Cable Termination
50 sqmm X 3.5Core CU Arm Cable Termination
35 sqmm X 3.5Core CU Arm Cable Termination
120 sqmm X 3.5Core CU Arm Cable Termination
25 sqmm X 4 Core CU Arm Cable Termination
16 sqmm X 4 Core CU Arm Cable Termination
16 sqmm X 3 Core CU Arm Cable Termination
10 sqmm X 4 Core CU Arm Cable Termination
10 sqmm X 3 Core CU Arm Cable Termination
6 sqmm X 4 Core CU Arm Cable Termination
6 sqmm X 3 Core CU Arm Cable Termination
4 sqmm X 4 Core CU Arm Cable Termination
4 sqmm X 3 Core CU Arm Cable Termination
2.5 sqmm X 4 Core CU Arm Cable Termination
2.5 sqmm X 3 Core CU Arm Cable Termination
1.5 sqmm X 4 Core CU Arm Cable Termination
1.5 sqmm X 3 Core CU Arm Cable Termination
SITC of Earthing
Earth wire/strips : Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : a) Fixing accessories, b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.
Providing earthing pit with : 3Mtr long Copper strip with 600*600*6mm CU Plate at bottom and GI pipe charcoal,salt,etc.. & all related accessories with Earthing chamber with marking of earth pit resistance with date on plate.
25 x 3 mm cu. Strip with green sleeve
8 SWG copper Bare wire
Labour Works
Removing of all type Light Fixtures
Removing of all type Fan Fixtures
Removing of all type wiring.
Skilled Labour
Un Skilled Labour
Removing of all type cable.
Removing of all old wiring,fittings,accessories,etc from house
ITC of Street Light Pole
21 Feet Pole including RCC foundation of 60cm(L)*60cm(W)*150cm(D) and earthing with 8 swg CU wire spiral earthing
10 Feet Pole including RCC foundation of 60cm(L)*60cm(W)*60cm(D) and earthing with 8 swg CU wire spiral earthing
15 Feet Pole including RCC foundation of 60cm(L)*60cm(W)*90cm(D) and earthing with 8 swg CU wire spiral earthing
21 Feet Pole without RCC foundation including welding/fabrication works.
10 Feet Pole without RCC foundation including welding/fabrication works.
15 Feet Pole without RCC foundation including welding/fabrication works.
Replacement of non modular switchboard with modular switchboard without wires (Legrand make)
6A One Way Switch
6A Socket
16A One Way Switch (With Light)
16A Socket
20/25A One Way Switch(With Light)
20/25A Socket
6A Two Way Switch
6A Bell Push Switch
Fan Regulator (100/250W- 1 Modules) - Humming Free
Fan Regulator (100/250W- 2 Modules)
Dummy Switch Blank Plate
1 or 2 Module Plate
3 Module Plate
4 Module Plate
6 Module Plate
8 Module Plate
12 Module Plate
1 or 2 Module Conceal MS Box
3 Module Conceal MS Box
4 Module Conceal MS Box
6 Module Conceal MS Box
8 Module Conceal MS Box
12 Module Conceal MS Box
1 or 2 Module Surface Mounted box & plate
3 Module Surface Mounted box & plate
4 Module Surface Mounted box & plate
6 Module Surface Mounted box & plate
8 Module Surface Mounted box & plate
12 Module Surface Mounted box & plate
ELECTRICAL WORKS: Cable Tray ; Supply & Installation of hot dip GI ladder type / GI Perforated cable tray with all accessories like Anchor fastener, coupler, GI nut bolts, bend, tee, reducer,support etc as per specification and drawings complete with all required hardware :
GI ladder type cable tray 150 x 50 made out of 2 mm thick
GI ladder type cable tray 300 x 50 made out of 2 mm thick
GI ladder type cable tray 450 x 100 made out of 2 mm thick
GI Perforated cable tray 150 x 50 made out of 2 mm thick
GI Perforated cable tray 300 x 50 made out of 2 mm thick
GI Perforated cable tray 100 x 50 made out of 2 mm thick
ITC of street light Junction Box (new junction box supply in the scope of IIMA). Work includes fabrication job for removal of old/rusted junction box from the pole, supplying & fixing of MS strips on the pole, installation of the new junction box, cable & earthing connection to the junction box.
Cleaning of solar PV panels installed on roofs of various buildings of IIMA. Work includes cleaning of the panels using a soft rag/soft mop or non-abrasive sponge so that all the dust/debris/bird droppings are removed
SITC of OFC Works
12-cores outdoor single mode OS2 - Unitube Optical Fibber Cable with Corrugated Steel tape Armoured, Loose-tube, Gel-filled, 9/125 μ in 32mm HDPE pipe
12-cores outdoor single mode OS2 - Unitube Optical Fiber Cable with Corrugated Steel tape Armoured, Loose-tube, Gel-filled, 9/125 μ in open wall mounting
ITC of OFC Works
12-cores outdoor single mode OS2 - Unitube Optical Fiber Cable with Corrugated Steel tape Armoured, Loose-tube, Gel-filled, 9/125 μ in 32mm HDPE pipe
12-cores outdoor single mode OS2 - Unitube Optical Fiber Cable with Corrugated Steel tape Armoured, Loose-tube, Gel-filled, 9/125 μ in open wall mounting
SITC of OFC Termination
12F, 1U, LC SM OS2, fully Loaded with Pigtails, Splice Tray, Adapter & splice protectors
Single Mode OFC Splicing with OTDR testing
Multi Mode OFC Splicing with OTDR testing
ITC of OFC Termination
12F, 1U, LC SM OS2, fully Loaded with Pigtails, Splice Tray, Adapter & splice protectors
Single Mode OFC Splicing with OTDR testing
Multi Mode OFC Splicing with OTDR testing
Checking of Network Cabling
End to End testing of Multi Mode/ Single Mode OFC cable
End to End testing of UTP cable (CAT-6 / CAT-6A)
Horizontal road cross boring (without damaging the road) including laying of P.V.C pipe 10 Kg./Cm2 and disposal of remaining earth outside the campus.
100 mm dia. PVC PIPE
150 mm dia. PVC PIPE
200 mm dia. PVC PIPE
300 mm dia. PVC PIPE
Doing Core Cut in Brick wall of
50mm dia
75mm dia
100mm dia
150mm dia
200mm dia
Doing Core Cut in RCC wall/slab of
50mm dia
75mm dia
100mm dia
150mm dia
200mm dia
VAIDEHI ENTERPRISE
R.B.TRADING CO.
Mahi Enterprise
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .