Loading…
Loading…
Tender ID
Tender Value
₹3.9 L
EMD Value
₹7,806
Closing Date
23 Mar 2026, 3:00 pmClosed
AE, Rajarhat Electrical Sub-Division, PWD
Purta Bhawan, Room No 112 ,Salt Lake
Repairing of Electrical wiring and installations of different type light fittings and fixtures and allied Electrical works at Newtown Rajarhat Fire station Kolkata 700156
2026_WBPWD_1022949_1
WBPWD/AE/BESD-I/e-NIT-25/25-26
Open Tender
ELECTRICAL WORKS ORG
Percentage
7 days
Newtown Rajarhat Fire station
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,806
13 May 2026
14 Mar 2026
25 Mar 2026
15 Mar 2026
23 Mar 2026
15 Mar 2026
Supply of BIS approved new generation energy saving, environment friendly and long lasting heat resistant, IP-66 & IK10 rated 150 watt (maximum) LED street light luminaries with pressure diecast aluminium housing and Toughened Glass/PC cover provided with high power LEDs and secondary optics PCIPMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with built in 4 KV surge protection and 10KV external SPD with Efficacy>135 lumen/watt, CRI >70, CCT>5700K. Make:- Wipro,Voyage /Crompton, Falcon Pro I/ Bajaj Hexo J/PHILIPS Urban edge Plus ) Driver Mk.- Philips SigniS/Wipro / Xtanium / Inventronics. LED Chip mk.-Nichia,Cree,Osram, Lumiled.
Fixing only Floodlight/ street light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure as per the direction of EIC.
S&F 240V, IP65, 150W Highbay LED fittings having Luminous flux of 15000lm, efficacy not less than 160lm/W, CCT 5700K with necessary fixing arrangement as per direction of the EIC (Make: Philips Greenperfoem Prime Gen 2/ equivalent of Wipro/ Crompton/ Surya/Magik)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kable/Polycab/KEI/Finolex/Mescab/ Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] i) Average run 8 mtr
S & D of 23 cm (9"), 1370 RPM Exhaust fans (Make- EPC/USHA/Crompton).
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: i) 23 cm (9")
S & D 1200 mm sweep AC ceiling fan without regulator , complete with P-2 burst proof capacitor, Down rod, blades, canopy, safty Tie wire etc Incl. other accessories as necessary. (Make-Orient NEWBREEZE/ Crompton Aura 1200mm/Havells Eo.)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing additional down rod exceeding 30 cm for ceiling fan 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Delivery Twin LED 4ft light fitting complete with all accessories incuding S & D of 2 no.18 Watt LED T8 Lamp 2100 lm [Philips (TMC 502 1 x T-LED 22W with MAS LEDTube 1200mm 18W 865 T8I-2100 lm)/ Wipro as directed by EIC
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing of 18W LED T8 Lamp only directly in existing LED batten/fitting [Philips (MAS LEDTube 1200mm 18W 865 T8I-2100 lm)/as directed by EIC
Supply & Fixing 240V 6A Modular type switch (Brand approved by EIC) on existing Gi Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240V 16A Modular type switch (Brand approved by EIC) on existing Gi Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240V, 6A, 5 pin Modular type plug socket (Brand approved by EIC),without plug top and switch,on existing GI Modular type switch board with top cover plate and makingnecy. Connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240V, 16A, 3pin Modular type plug socket (Brand approved by EIC),without plug top and switch,on existing GI Modular type switch board with top cover plate and makingnecy. Connections with PVC Cu wire and earth continuity wire etc.
SITC of split type AC machines having Cooling Capacity range 2T (5.2 kw - 5.3 kw), with variable specd rotary compressor, refrigerant gas R32/R410 BEE star rating-3 (EER range 3.5 to 3.99), Air flow range CFM (560-600) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to 1S 1391 (Part-I & Part-II) with all amendments Make- Mitsubishi Electric/ Daikin/0-Gencral/Carrier/ Voltas/ Blue Star/LG/Panasonic/Hitachi/ Mitsubishi Heavy) [NS]
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 5/8'' (15.88 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
1/4'' (6.4 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply & laying PVC drain pipe 25 mm dia with 6 mm thick Nitrile Rubber Insulation. (Suprime/oriplast)
Supply & Fixing 240 V, 25 A, OLP 3+ starter (Brand approved by EIC) incl. 4 Module GI Modular type switch board with all accessories as required flushed in wall incl. S&F switch board and making necy. connections with PVC Cu wire and earth continuity wire etc. as per direction of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (for A.C wiring) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as to GS. 2 x 56/0.3 (4 sqmm)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as to GS. 1 x 36/0.3 (2.5 sqmm) ECC.
Supply & Fixing 240 V, 24 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. as to GS.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections as to GS.
Add: GST for works contract@18% on Item Sl. No. 1.00 to 24.00
Add: L.W.Cess @ 1 % on total
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.43 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_2514187.xls
BOQ • 0.38 MB
2911_ii.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .