Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹18.5 LAccepted-AOC | l1 | Accepted-AOC accept | |
| 2 | l2₹23.3 L+₹63,500 (2.80%)Rejected-AOC | l2 | Rejected-AOC not accept | |
| 3 | l3₹23.4 L+₹75,000 (3.31%)Rejected-AOC | l3 | Rejected-AOC not accept | |
| 4 | l4₹25.1 L+₹2.4 L (10.7%)Rejected-AOC | l4 | Rejected-AOC not accept | |
| 5 | l5₹26.3 L+₹3.6 L (16.0%)Rejected-AOC | l5 | Rejected-AOC not accept |
Tender Value
₹17.4 L
EMD Value
₹33,540
Closing Date
21 Oct 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er.Anand Blouria
Jal Shakti Division Nurpur
Twell 120 mtr deep at village Bhadroot
2023_HPIPH_80045_1
hp-npr-EA1731 dt 11-10-2023
Open Tender
Civil Works
Item Rate
180 days
Bhadroot
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
Yes
₹33,540
Yes
29 Nov 2023
11 Oct 2023
21 Oct 2023
11 Oct 2023
21 Oct 2023
11 Oct 2023
Amount
Transportation of Rig along-with allied accessories etc.complete including erection and levelling at site through all kind of roads,approaches field etc.in all leads and lifts upto site of work complete in all respect as per the direction of the Engineer in charge.
Drilling of bore as per specifications laid down in IS-2800-1991(Part-I) with uptodate ammendments,if any;with Percussion Rig or combination drilling Rig starting with 650-600mm.dia M.S.Pipe reduced to 450-400mm.dia M.S.pipe confirming to IS-4270-2001 with uptodate ammendments,if any in all kinds of soils,boulders,rocks, collapsible strata,saturated soil, artesian conditions including the cost of all consumables,stores, water, fuel, lubricants and other accessories etc.complete in all respect as per the direction of the Engineer in charge..
Drilling and lowering of M.S.casing pipes 650-600mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 0 to 30 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge.
Drilling and lowering of M.S.casing pipes 600-550mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 30 Metres to 60 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge.
Drilling and lowering of M.S.casing pipes 550-500mm. Dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 60 Metres to 90 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge.
Drilling and lowering of M.S.casing pipes 500-450mm.dia confirming to IS-4270-2001 with uptodate amme dments if any of suitable sizes as mentioned above from 90 to 120 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge.
Collection,preservations and display of suitable size sample box with top lid and locking arrangem,ent till handing over of the Tube-Well to the Department complete in all respect as per the direction of the Engineer in charge.
Supply and lowering of IS-Marked "Electric Resistance Welded Mild Blind Steel Pipe 250mm.nominal size housing, 7.10mm. thick having outside diametre 273.10 mm.(BEVELLED EDGE PLANE ENDED)screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length,welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc. including cost of all cuttings,threading and welding of pipes etc.within all leads and lifts as per the direction of the Engineer in charge.
Supply and lowering of IS-Marked Electric Resistance Welded Mild Steel slotted pipe 250mm.dia nominal size housing, 7.10mm.thick having outside diametre 273.10mm.(BEVELLED EDGE PLANE ENDED) screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length pipe should have 1600 slots per metre as per IS-8110:1985 of 75x1.57mm.slot size, welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc.including cost of all cuttings, threading and welding of pipes etc.complete in all respect as per the direction of the Engineer in charge.
Providing and fixing of M.S.centralized guides at suitable spacing for each Tube-Well as per IS-226-1991 with uptodate ammendments, if any within all leads and lifts complete in all respect as per the direction of the Engineer in charge.
Supply,lowering and fixing in position IS-Marked Mild Steel bail plug of 265mm Diametres with 'U' hooks as per IS-2800-1991 with uptodate ammendments,if any within all leads and lifts complete in all respect as per the direction of the Engineer in charge.
Providing,fixing and lowering in position threaded iron cap with locking arrangements of approved design to prevent foreign matter from getting into bore hole as required complete in all respect as per the direction of the Engineer in charge.
Supply and packing of gravel consisting of hard quartz or other suitable material with an average specific gravity of not less than 2.5, not containing more than 2% by weight of thin flat or elangated pieces shall be of sub rounded to rounded grains with minimum angular features of size 2-3.35mm.shall be free from impurities such as; shafe,shale mica, feldspar, clay, sand, dirt loam hematite and organic materials as per IS-4097-1967 with uptodate ammendments, if any around intake of Tube-Well with minimum thickness of shroud around screen generally 100mm. to the entire depth of the bore as per IS-2800(Part-I):1991 with uptodate ammendments, if any, within all leads and lifts complete in all respect as per the direction of the Engineer in charge
Development of Tube-Well by backwashing method with Air Compressor of minimum 750CFM capacity Pumping pipe of 200mm. Size and Air line of minimum 65mm size or with other suitable method, till the Well is thoroughly developed as per Clause-4.2 of IS-11189:1985, with upto date ammendments, if any; complete in all respect as per the direction of the Engineer in charge.
Development of Tube-Well by continuous over Pumping method with V.T.Pumps/Submersible Pumps of suitable capacity not less than double the discharge established by the Compressor method/design discharge, untill the well sand free as per IS-11189:1985 with uptodate ammendments, if any; complete in all respect as per the directions of the Engineer-in-Charge. The draw-down and discharge to be established by running the VT/Submersible pump continuously for 8 Hours in the presence of the officer not less than the rank of the Assistant Engineer.
Testing the verticality of the Tube-Well as per Clause-4.3 of IS-2800(Part-II)-1979 with uptodate ammendments, if any, using plumb or plunger 6mm.smaller in dia within the inside diameter of the Well casing. The result of the verticality test shall be recorded on proforma shown in Appendix-A of IS:2800(Part-II)-1979 with uptodate ammendments, if any as appended with the tender documents and handed over complete in all respect as per the direction of the Engineer in charge.
Dismantling of Rig or other allied accessories after completion of job within all leads and lifts complete in all respect as per the direction of the Engineer in charge.
JASPREET SINGH
Akarshan Jaswal
H.N.SINGH AND COMPANY
ABTAR SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .