Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹34.1 L Quoted ₹36.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹37.7 LRejected-AOC 292 KRISHNA COLONY OLD HAMIDA SAHARANPUR ROAD YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹37.7 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹40.9 LRejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹40.9 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹44.4 LRejected-AOC | ₹44.4 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹44.9 LRejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹44.9 L | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | Ansh Enterprises L5 | Friends fire Engineers L1 | Niyana Innovation Works L6 | M/S Durvish Mourya L2 | M/s Kamal Traders L3 | PARADISE INFRA POWER COMPANY L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as directed. | 832.68 | Cum | 98 ₹81,602.64 | 49 ₹40,801.32 | 110 ₹91,594.80 | 80 ₹66,614.40 | 50 ₹41,634 | 50 ₹41,634 |
| 2.00 | Material and labour for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as directed. | 333.07 | Cum | 355 ₹1.2 L | 249 ₹82,934.93 | 500 ₹1.7 L | 250 ₹83,268 | 300 ₹99,921.60 | 50 ₹16,653.60 |
| 3.00 | Material & labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as directed. | 20,560 | Each | 4 ₹82,240 | 3 ₹61,680 | 5.5 ₹1.1 L | 3 ₹61,680 | 3 ₹61,680 | 5 ₹1.0 L |
| 4.00 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as directed. | 400 | Cum | 20 ₹8,000 | 9 ₹3,600 | 45 ₹18,000 | 20 ₹8,000 | 1 ₹400 | 50 ₹20,000 |
| 5.00 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as directed. | 432.68 | Cum | 20 ₹8,653.60 | 9 ₹3,894.12 | 45 ₹19,470.60 | 20 ₹8,653.60 | 1 ₹432.68 | 50 ₹21,634 |
| 6.00 | Material and labour for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc size of cutting 100mm wide and 600mm deep and removing the excavated materials and disposal at 50 metre distance and making good to the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as directed.
Note:-
(a) Cost of GI/ HDPE pipe shall be measured and paid separately under relevant items. | 45 | RM | 50 ₹2,250 | 49 ₹2,205 | 300 ₹13,500 | 250 ₹11,250 | 50 ₹2,250 | 450 ₹20,250 |
| 7.00 | Material & labour for cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as directed. | 4 | Cum | 2,250 ₹9,000 | 399 ₹1,596 | 5,000 ₹20,000 | 2,000 ₹8,000 | 2,000 ₹8,000 | 3,500 ₹14,000 |
| 8.00 | Material & labour for cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as directed. | 0.15 | Cum | 5,250 ₹787.50 | 999 ₹149.85 | 6,000 ₹900 | 4,000 ₹600 | 10,000 ₹1,500 | 4,500 ₹675 |
| 9.00 | Taking out carefully LT cable of any size or type or make from ground/ poles/ pipes etc and testing for serviceability and laying the same serviceable LT cables under ground/ on poles/ through pipes etc at same or any other location and testing after connections complete all as directed.
Note:-
(a) Item to be measured only when cable is found serviceble for reuse.
(b) Necessary excavation, sand cushioning, cable protection covers, returning, removal etc shall be measured and paid separately under relevant items. | 500 | RM | 40 ₹20,000 | 1 ₹500 | 60 ₹30,000 | 40 ₹20,000 | 1 ₹500 | 50 ₹25,000 |
| 10.00Material and labour for laying, jointing and testing in replacement underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area all as directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. | |||||||||
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Feb 2026, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/ maintenance and improvement of LT network, UG cables, OH lines, LT panels, Feeder pillar boxes and other connected items at MH and Garhi Cantt under AGE E/M-II of GE Dehradun.
2026_MES_752199_1
8133/A/E8
Open Tender
Civil Works
180 days
GE Dehradun
Class D cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹90,000
Yes
13 Mar 2026
11 Feb 2026
2 Mar 2026
11 Feb 2026
28 Feb 2026
16 Feb 2026
Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as directed.
Material and labour for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as directed.
Material & labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Material and labour for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc size of cutting 100mm wide and 300mm deep and removing the excavated materials and disposal at 50 metre distance and making good to the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as directed. Note:- (a) Cost of GI/ HDPE pipe shall be measured and paid separately under relevant items.
Material & labour for cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as directed.
Material & labour for cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as directed.
Taking out carefully LT cable of any size or type or make from ground/ poles/ pipes etc and testing for serviceability and laying the same serviceable LT cables under ground/ on poles/ through pipes etc at same or any other location and testing after connections complete all as directed. Note:- (a) Item to be measured only when cable is found serviceble for reuse. (b) Necessary excavation, sand cushioning, cable protection covers, returning, removal etc shall be measured and paid separately under relevant items.
Material and labour for laying, jointing and testing in replacement underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area all as directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
10.0 Sqmm, 4 core.
16.0 Sqmm, 4 core.
25.0 Sqmm, 4 core.
35.0 Sqmm, 4 core.
50.0 Sqmm, 3.5 core.
70.0 Sqmm, 3.5 core.
95.0 Sqmm, 3.5 core.
120.0 Sqmm, 3.5 core.
150.0 Sqmm, 3.5 core.
185.0 Sqmm, 3.5 core.
240.0 Sqmm, 3.5 core.
300.0 Sqmm, 3.5 core.
Supply & Laying of High density polyethylene pipes (HDPE) of pressure rating PN 6 size laid in trenches/ fixed to poles/ wall/ laid in floor for the protection of UG cable for following bore of pipes:
size 50 mm
size 80 mm
size 100 mm
Supplying, errecting and fixing in replacement steel tubular swaged poles of following type and height, complete with cast iron base plate, heat resistance finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/straps with white and red colour (30cm wide each) epoxy heat resistant paint at a distance 30cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including taking out existing unserviceable pole of any type/ height/ make etc and depositing to MES store yard or for taking credit all as directed. Notes: 1. Excavation, returning, removal, PCC for foundation and coping etc shall be measured and paid separately. 2. Any damage done during erection of pole to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. 3. Cost of T&P required for transporting/ handling/ erection etc of pole is deemed to be included in the rate quoted by the contractor.
Type 410-SP-31, 9.00 metre long
Material & Labour for fixing in replacement cross arms, bracing, supports, clamps and back plates fabricated from structural steel section (flat iron/ angle iron/ MS sheet) including back plate, MS boxes made out of MS sheet, clamps or D clamps made out of MS flat iron made to shape including nuts, bolts, washers, welding, bending hot or cold, drilling holes for bolt in any size or shape as directed inclusive of two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable of any size/ type etc and depositing to MES store yard or for taking credit complete all as directed.
Material and labour for replacement of unserviceable earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/ transformer/ panel all as directed and testing on completion as directed including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, RCC pit cover, charcoal, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note: (i) If the desired earth resistance is not found within permissible limit of less than 5 Ohm, earthing shall be redone by contractor without any extra cost. (ii) Cost of galvanised earth lead upto 7.5 mtr, 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering is included in the rate quoted for this item.
All as per item 14 above but with galvanised iron strip 32x6 mm as earthing lead and protection pipe of dia 50mm.
Material and labour for replacement of unserviceable earthing with maintenance free earthing with copper electrode 50mm dia thick buried directly in ground vertically to a depth not less than 2.10 mtr below ground level filled with highly conductive metalic compound mixture CCM with the permanent sealing of the both end, outer dia pipe 50mm with strip terminal 50x6 with terminal holes including one bag 25 kg of bfc compound, earth connected with copper strip 20 x 3 mm as earth lead by means of bolts, Nuts, check nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board protected by galvanized iron pipe medium 40 mm bore, PVC chamber as per manufacturer instruction and testing on completion. Note: (a) If the desired earth resistance is not found within permissible limit of less than 2 Ohm, earthing shall be redone by contractor without any extra cost. (b) Cost of copper earth lead upto 7.5 mtr, 40mm dia light grade GI pipe is included in the rate quoted for this item. thimbles and other end of the earth wire connected to main switch board protected by galvanized iron pipe medium 40 mm bore, PVC chamber as per manufacturer instruction and testing on completion.
Supply and fixing in replacement MCCB 415 V with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete of following capacities including fixing properly with new suitable size of thimbles, nut - bolt and washers and taking down existing unserviceable of any type/ make etc and depositing to MES store yard or for taking credit all as directed.
MCCB 400 Amps, 4 pole of breaking capacity 36 KA
MCCB 320 Amps, 4 pole of breaking capacity 36 KA
MCCB 250 Amps, 4 pole of breaking capacity 36 KA
MCCB 200 Amps, 4 pole of breaking capacity 25 KA
MCCB 160 Amps, 4 pole of breaking capacity 25 KA
MCCB 125 Amps, 4 pole of breaking capacity 25 KA
MCCB 100 Amps, 4 pole of breaking capacity 25 KA
MCCB 63 Amps, 4 pole of breaking capacity 25 KA
Material and labour for replacement off load change over switch, four pole 415 volts, 50 Hz side handle operated in sheet metal enclosure, powder coated weather proof conforming to IEC 13947-3 inclduing taking out old unserviceable one of following capacities:-
63 Amps, 4 pole.
100 Amps, 4 pole.
200 Amps, 4 pole.
Supply, Installation, commissioning & testing of factory made CPRI approved, LT switch gear panel board, IP-54 (outdoor type), 415 volts, 50 Hz, AC supply, three phase and neutral (4 wire), 400 Amps aluminium busbars 4 pole, duly insulated with heat shrinkable sleeve as per colour code supported on epoxy insulatators, having independent compartment for insulated busbar, incoming feeder & each outgoing feeder i.e. cubicle type, made out of 3.00 mm thick CRCA sheet and 2mm thick inner enclosure CRCA sheet, rigid mild steel angle iron frame of 50x50x6mm with 900mm long extended legs grouting in PCC 1:3:6 type C2 block of size 1000x300x600mm, duly epoxy powder coated internally & externally with approved shade, rubber gasket, hinged front & back openable doors with proper locking arrangements for dust and vermin proof, complete including suitable size cable alley, lugs, cable glands, common earth bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders/wiring with suitable size of single core PVC copper conductor cable, locking arrangements 65mm size and lock with keys, earth work and excavation comprising the following: Incoming :- (a) MCCB 250 Amps 4P, 35 KA, Adjustable thermal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos., Meter set : Digital voltmeter,Ammeter + CT : 400/5, RYB indicating Lamp LED type 240 V, MCB SP 6A, 400 Amp Alluminium Bus Bar Outgoing :- (a) MCCB 100 Amp FP, 25 KA, Adj tharmal & fixed magnetic setting,Ics=100% of Icu with spreader link - 02 Nos. (b) MCCB 63 Amp FP,16 KA, Adj tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 02 Nos.
Description all as per item No 19 here-in before but with following switch gears : Incoming :- (a) 400 Amps 4P, 35 KA , Adjustable tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos. (b) Meter set : Digital voltmeter, Ammeter + CT : 400/5, RYB Indicating Lamp LED type 240 V, MCB SP 6A, 600 Amp Alluminium Bus Bar Outgoing :- (a) MCCB 250 Amp FP,25 KA,,Adj tharmal & fixed magnetic setting,Ics=100% of Icu with spreader link - 01 Nos. (b) MCCB 160 Amp FP,25 KA,,Adj tharmal & fixed magnetic setting,Ics=100% of Icu with spreader link - 01 Nos. (c) MCCB 100 Amp FP,16 KA,Adj tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos.
Dismantling carefully existing steel poles/ struts/ PCC poles of any size/ type for reuse including necessary excavation, demolition of concrete, shifting to a location as directed and removing the old concrete/ PCC rubbish etc complete all as directed. Note - Item to be measured only when pole is found serviceble for reuse at same or any other location.
Labour only for fixing/ erecting only of steel/ PCC poles of any length and type retrieved from demolition/ dismantling of item No 21 here in above of including loading, shifting, unloading and erection in true vertical position complete all as directed.
Supply and fixing in replacement post top lantern LED type of 20 Watt capacity 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp from pole of any height/ pillar/ bldg wall etc CCT not less than 5700K, IP 65 complete including taking down existing unserviceable light fittings all as directed.
Supply and fix in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 90 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 70 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Material and labour for painting of steel pole 09 meter height after preparing the surface by scrapping old paint with sand paper with two coat of aluminium paint over a coat of red oxide primer incuding making 5 nos of alternative strips of black and yellow paint of 30 cm width & numbering of pole as per existing complete all as directed.
Material & Labour and installation in replacement after dismantling of old US bus bar, factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 200 Amps, 4 pole, 16 KA, with adjustable thermal setting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber.
NOTE:- Amount of credit of Rs. 238275.00 for retrieved materials is mentioned in Schedule of Credit Page No 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8133Tenderdocuments.pdf
Tender Documents • 0.90 MB
BOQ_842496.xls
BOQ • 2.01 MB
Download all tender documents and submit your bid