BSNL Electrical Division, CTO Building, Trichy
SH Providing MCCBs in Main MV panel Emergency panel AC panel and servicing of Panels VCBs ACBs in Substation
2023_BSNL_167859_1
20 / EEE BSNL ED/TR/ 2023-2024
Open Tender
Electrical Works
Works
30 days
Trichy
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (CASH), BSNL
₹8,537
26 Sept 2023
16 Sept 2023
26 Sept 2023
16 Sept 2023
25 Sept 2023
16 Sept 2023
Supplying and fixing of 630 Amps 4 Pole MCCB with release range (500 A-630A) with breaking capacity not less than 36 KA with spreader terminals (Ics =100 % Icu) on both side, including providing rotary front handle arrangement in the existing working MV panel/ Emergency panel, interconnecting the MCCB with the existing bus bar arrangement with suitable size of Aluminium alloy bus bars i/c Modification and alteration if any, testing, commissioning etc., as required.
Supplying and fixing of 250 Amps 4 Pole MCCB with breaking capacity not less than 25 KA with spreader terminals (Ics= 100 % Icu) on both side including providing rotary front handle arrangement in the existing AC plant MV panel, interconnecting the MCCB with the existing bus bar arrangement with suitable size of Aluminium alloy bus bars i/c Modification and alteration if any, testing, commissioning etc., as required.
Providing Mechanical interlock arrangement for the existing 250Amps 4 pole MCCB and 400 Amps 4 pole MCCB with key lock (2 lock + 1 key set) including modification work in the existing MV panel, testing and commissioning etc as required.
Removal of 250 Amps 4 Pole MCCB from the existing Emergency panel and refixing of the same in the existing MV panel, i/c Providing new front handle arrangement, interconnecting the MCCB with the existing bus bar arrangement with suitable size of Aluminium alloy bus bars i/c Modification and alteration if any required, testing, commissioning etc., as required.
SITC of 63 A TPN Switch Disconnector Fuse unit interior suitable for panel mounting, with 3 Nos. 32 A HRC Fuses in the existing MV Panel including removing the existing faulty switch, testing and commissioning etc as required.
Supplying and making digital type meter measuring integrated voltage, current, frequency measuring meter of size 96 mm.sq in the existing AC plant panel with suitable control fuses, wiring with the existing CTs, testing and commissioning etc as required. (Make: L&T Model 4110 series or similar superior make)
Supplying and fixing Recess mounted LED type Round/Square light fitting with 15W i/c Providing interconnections, testing and commissioning etc., as required (Make: Crompton /Philips/ Wipro (or) similar superior make)
Complete cleaning of the existing 1250 KVA rating 11KV / 433V Dry type Cast resin Transformer by using the vacuum cleaner/ blower and tightening of the HT Cable end termination in Primary side and tightening of bus bar in Secondary side etc., as reqd.
Servicing of 630A rating 11 KV Vacuum Circuit Breakers, Overhauling, verifying ON/OFF/TRIP operations, Cleaning the terminals, verifying proper functioning of Electrical and Mechanical joints/points, Verifying IR values with suitable Megger, testing and commissioning etc. as reqd. HT Switch Board Panel: Make: Kirloskar, Type : A12VCB, Systems Voltage : 11 KV, 50 Hz, Control supply 230 V AC / 24 V DC. (Excluding the cost of spares) NOTE: This work shall be carried out by authorized dealer of the equipments in the presence of Engineer-in charge/representative
Servicing of following rating Air Circuit Breakers, Overhauling, verifying ON/OFF operations, cleaning the terminals, cleaning the air chute arrangement, verifying proper functioning of Electrical and Mechanical joints/points, Cleaning the dust, testing the tripping arrangement buy using the suitable test kit, testing and commissioning but excluding etc. as reqd..(NOTE: This work shall be carried out by authorized dealer of the equipments mentioned below in the presence of Engineer-in charge/representative
2000A ACB, Make : L&T, Model: CN-CS 2000 C
2000A ACB, Make : SIEMENS Model: 3VV18
Servicing and Testing of 3 element IDMT relays in the HT panels by injection method with suitable test kit and verify the tripping condition for all settings i/c Cleaning the fixed and moving parts, rectifying physical movments, lapping, transportation of the test kit as per requirement etc., as reqd.
Complete checking and servicing of all MV panels /Emergency panels associated with substation including cleaning with the Vacuum cleaner/Blower and tightening of all incoming and outgoing bus bar terminals connected to TPN switches, complete checking of metering compartments, replacing the worn-out rubber beading etc; as required.
a) Main MV Panel Consisting of two nos. of 630A MCCBs and 21 Nos. of TPN switchgear of various capacities but excluding ACBs b) New LT Panel Consisting of 10 Nos. of TPN switchgear of various capacities c) Emergency supply Panel (Old) Consisting of 8 Nos. of TPN switchgear of various capacities d) Emergency Panel (New) Consisting of 3 Nos. of 630A MCCBs and 4 Nos. of TPN switchgear of various capacities but excluding ACBs. /All the above consist of one Job/
Complete checking of the existing Power Factor Capacitor Panel (220 KVAR ) including cleaning and tightening of all bus bar terminals, incoming and outgoing terminals, healthiness of capacitor by measuring load current of each capacitors, replacing the worn-out rubber feedings and submission of the report of the status/condition of the capacitor etc as required.
Checking the insulation value of standby 3 x 185 sq.mm 11KV HT Cable by using suitable Megger etc., as reqd.
Supplying and laying of rubber mat of class "B" type suitable for MV supply etc., as required. ( ISI marked)
Supplying of the following materials for safe handling of electrical works as required.
Hand Gloves suitable for 11 KV supply
Earth discharge rod with insulation handle arrangement suitable for 11 KV supply.
RRK ENTERPRISES
stage.html
html • 0.02 MB
finance_183796.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .