Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.0 LAccepted-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC as per decision cwc 08032024 | |
| 2 | L2₹87.9 L+₹91,103.39 (1.05%)Rejected-Finance 1 BAJRANG NAGAR INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L2 | Rejected-Finance AS PER DECISION CWC MEETING HELD ON 08032024 | |
| 3 | L3₹88.1 L+₹1.1 L (1.27%)Rejected-Finance | L3 | Rejected-Finance AS PER DECISION CWC MEETING HELD ON 08032024 | |
| 4 | L4₹1.0 Cr+₹14.1 L (16.2%)Rejected-Finance | L4 | Rejected-Finance AS PER DECISION CWC MEETING HELD ON 08032024 | |
| 5 | L5₹1.0 Cr+₹15.7 L (18.0%)Rejected-Finance | L5 | Rejected-Finance AS PER DECISION CWC MEETING HELD ON 08032024 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
26 Jan 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr. General Manager, Ordnance Factory Dehuroad, Pu
Ordnance Factory Dehu Road, Pune
Replacement of Overhead Electrical supply system to underground system in TypeI and II SS4 and SS9 area area at OFDR
2024_MIL_180769_1
T. E. NO. GM/OFDR/B/R/687 OF 2023-2024
Open Tender
Electrical Works
Item Rate
240 days
Ordnance Factory Dehu Road
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.9 L
19 Mar 2024
8 Jan 2024
27 Jan 2024
8 Jan 2024
26 Jan 2024
8 Jan 2024
Amount
M & L for XLPE insulated heavy duty electric cable with aluminium conductor,1100 volt grade,cross-sectional area 16 Sq MM,4 core. All as specified in SSR Part-I and as directed by Engg-In-Charge. (Make: Finolex, Havells, Polycab or equivalent) (for Street Light)
M & L for XLPE insulated heavy duty electric cable with aluminium conductor,1100 volt grade,cross-sectional area 35 Sq MM,31/2 (Three and half ) core. All as specified in SSR Part-I and as directed by Engg-In-Charge. (Make: Finolex, Havells, Polycab or equivalent)
M & L for XLPE insulated heavy duty electric cable with aluminium conductor,1100 volt grade,cross-sectional area 70 Sq MM, 31/2 (Three and half core). All as specified in SSR Part-I and as directed by Engg-In-Charge. (Make: Finolex, Havells, Polycab or equivalent)
M & L for XLPE insulated heavy duty electric cable with aluminium conductor,1100 volt grade,cross-sectional area 120 Sq MM, 3 1/2 (Three and half) core. All as specified in SSR Part-I and as directed by Engg-In-Charge. (Make: Finolex, Havells, Polycab or equivalent)
Supply and fixing of Flange type cable gland of brass, strong grip and corrosion resistant, high compressive strength, excellent brass finish, suitable for fixing 3.5 core, aluminium conductor armoured cable 120 Sqmm size for termination in the paenl/FP/Junction box. etc complete. All as directed by Engg-In-Charge. Sample should be got approved before supply.
Supply and fixing of Flange type cable gland of brass, strong grip and corrosion resistant, high compressive strength, excellent brass finish, suitable for fixing 3.5 core, aluminium conductor armoured cable 70 Sqmm size for termination in the paenl/FP/Junction box. etc complete. All as directed by Engg-In-Charge. Sample should be got approved before supply.
Supply and fixing of Flange type cable gland of brass, strong grip and corrosion resistant, high compressive strength, excellent brass finish, suitable for fixing 4 core, aluminium conductor armoured cable 35 Sqmm size for termination in the paenl/FP/Junction box. etc complete. All as directed by Engg-In-Charge. Sample should be got approved before supply.
Supply and fixing of Pole Junction box, 240 mm X 130 mm X 110mm Size, 3 phase with neutral, terminations, with hinged type openable cover and locking arrangement, cable entry form bottom side, PVC/SMC (Equivalent to GS JB 2817 of Sintex make). weather proof outdoor type, Fire retardent Complying to IS 11731 & 10192. With all accessories such as clamps, nuts & bolts etc. and fixing on existing street light pole. All as directed by Engg-In-Charge. Sample approval shall be taken berfore installation at site. (Make: Sintex or equivalent) Sample should be got approved before supply
Supply and laying of Un-reinforced precast concrete cable cover class HVP,Type II flat, size 450mmX 180mmX40mm. All as Specified in SSR Part-I and as directed by Engg-In-Charge.
Dismantling and taking down street light fitting of any size, wattage for replacement or reuse or carrying out to store etc complete. All as specified in SSR Part-I & directed by Engg-In-Charge.
Fixing of LED Street light fitting 35 watt complete with wiring form junction box to the fitting. All as specifed in SSR Part-I and as directed by Engg-In-Charge.
Dismantling of ACSR or AAC conductors, Shifting the dismantled material to store scrap yard in factory etc complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge.
Dismantling insulators any type,any size, Shifting the dismantled material to store scrap yard in factory etc complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge.
Dismantling cross-arms of M S channel or angle sections etc.complete and Shifting the dismantled material to store scrap yard in factory etc complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge.
Supply and fixing of Flange type cable gland of brass, strong grip and corrosion resistant, high compressive strength, excellent brass finish, suitable for fixing 4 core, aluminium conductor armoured cable 16 Sqmm size for termination in the paenl/FP/Junction box. etc complete. All as directed by Engg-In-Charge. Sample should be got approved before supply.
Design,Supply,Fixing,connection and commissioning of Feeder Pillar of size of not less than 1.5 M (L) X 1.0 M (W) X 0.5 M (D) made of MS sheet of gauge 14 SWG minimum, with suitable frame work, stand alone type comforming to IP 55 ( According to index of protection for enclosures of electrical equipment as per IS 2147/1962) complete with two coats of oil primer and two coats of powder coat painting of approved colour. Feeder Pillar should be of all weather proof type and easy for maintenance with internal lighting, Indication lamps for 3 phase indication for incoming supply, Double shutter, with proper locking arrangement, proper insulation to live part, proper ventilation, identification for wires and distribution MCBs, Provision for Double earthing, Danger board of standard size and feeder pillar name plate as directed. Feeder pillar should be mounted on a MS frame of size not less than 1 M Height of MS Angle 45X5 mm Minimum. Feeder Pillar should consisting of following items and all arrangement for accomodating the same. I) Incoming 400Amp, TPN, MCCB- 1 No II) Out going 1) 200Amp, TPN, MCCB- 2 No 2) 63 Amp, TPN, MCCB- 2 Nos 3) 32Amp, TPN, MCBs-15Nos (Make: Havells, Anchor, Legrand, L&T or equivalent) Sample should be got approved before supply
Design,Supply,Fixing,connection and commissioning of Feeder Pillar of size of not less than 1.5 M (L) X 1.0 M (W) X 0.5 M (D) made of MS sheet of gauge 14 SWG minimum, with suitable frame work, stand alone type comforming to IP 55 ( According to index of protection for enclosures of electrical equipment as per IS 2147/1962) complete with two coats of oil primer and two coats of powder coat painting of approved colour. Feeder Pillar should be of all weather proof type and easy for maintenance with internal lighting, Indication lamps for 3 phase indication for incoming supply, Double shutter, with proper locking arrangement, proper insulation to live part, proper ventilation, identification for wires and distribution MCBs, Provision for Double earthing, Danger board of standard size and feeder pillar name plate as directed. Feeder pillar should be mounted on a MS frame of size not less than 1 M Height of MS Angle 45X5 mm Minimum. Feeder Pillar should consisting of following items and all arrangement for accomodating the same. I) Incoming: 200Amp, TPN, MCCB -1 Nos II)Out going 1)100Amp,TPN, MCCB-1No 2)32Amp, TPN, MCBs-12Nos. (Make: Havells, Anchor, Legrand, L&T or equivalent) Sample should be got approved before supply
Excavating over areas exceeding 1.5 m and not exceeding 2.5m in Hard Dense Soil & getting out and returning, filling in, including spreading levelling watering and well ramming in layers not exc 25 cm etc complete. All as specified in SSR Part-I and as directed by Engg-In-Charge (Size of one pit 1 X 1 X 2.5 M).
Excavating over areas not exceeding 1.5 m in Hard rock & getting out and returning, filling in, including spreading levelling watering and well ramming in layers not exc 25 cm etc complete. All as specified in SSR Part-I and as directed by Engg-In-Charge.
M&L for Type B2 C.C. 1:2:4 40 mm graded aggregate) in foundation, filling and mass concrete including compaction curing complete. All as specified in SSR Part-I and as directed by Engg-In-Charge.
M & L for formwork to sides of concrete foundations, sides of soffits and similar work, vertical or batter for flat finished surfaces. All as specified in SSR Part-I and as directed by Engg-In-Charge.
S & F for M.S. plates (plain or chequered) 6 mm thick forming holes etc complete. (Size of plate 300mm X 300mm for one pit). All as specified in SSR Part-I and as directed by Engg-In-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick, buried directly in ground level,(earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 25 X 4 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion. All as specified in SSR Part-I and as directed by Engg-In-Charge.
S & F for Funnel size 1/2" dia, with GI perforated pipe of 1.5 m length for watering purpose with copper lugs etc complete all as directed by Engg-In-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/loose soil; for electric cable laying in trench size of 4700 M X 0.5 M wide X 0.6 deep. All as specified in SSR Part-I and as directed by Engg-In-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Hard/ dense soil; for electric cable laying in trench size of 4700 M X 0.5 M wide X 0.3 deep. All as specified in SSR Part-I and as directed by Engg-In-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Hard Rock; for electric cable laying in trench size of 4700 M X 0.5 M wide X 0.1 deep. All as specified in SSR Part-I and as directed by Engg-In-Charge.
Returning, filling in, inluding spreading, levelling, watering and well ramming in layers not exceeding 25 cm. All as specified in SSR Part-I and as directed by Engg-In-Charge
M&L for earth continuity conductor for pole to pole earthing of size 4 mm dia galvanized iron wire buried in ground or fixed to pole with suitable nut bolts and clamps or any other indicated situation for loop earthing etc as required. All as specified in SSR Part-I and as directed by Engg-In-Charge.
Rough excavation not exceeding 1.5 M deep and getting out in Soft Loose Soil etc complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge. (For FP Foundation)
M & L for Cement Concrete Type 2 C2 1:3:6 (40 mm graded aggregate) in foundations, filling and mass concrete etc complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge. (For FP Foundation)
M & L for Hardcore of gauge not exceeding 63 mm, broken stone or boulder deposited, spread and levelled in layers not exceeding 15 Cm thock, watered and rammed to true surface. All as Specified in SSR Part-I and as directed by Engg-In-Charge. (For FP Foundation)
Supply and laying of Reinforced concrete pipes, Bore 150 mm class NP2 laid in trench complete All as specified in SSR Part-I and as directed by Engg-In-Charge.
M & L for moorum filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering etc. complete. All as Specified in SSR Part-I and as directed by Engg-In-Charge.
Messers Rajesh Gawde
RAMA ELECTRICALS
Joy Construction
BHIRUD ELECTRIC STORES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .