Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance FLAT NO 203 KADIRIS APURUPA URBAN 2 ND FLOOR LAXMI NAGAR BOTANICAL GARDEN ROAD KONDAPUR HYDERABAD 500084 RANGAREDDI TELANGANA 500084 | HYDERABAD | TELANGANA | 500084 | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹2.1 L (1.15%)Admitted-Finance | ₹1.9 Cr+₹2.1 L (1.15%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹10.2 L (5.50%)Admitted-Finance | ₹2.0 Cr+₹10.2 L (5.50%) | L3 | Admitted-Finance |
| 4 | L4₹2.0 Cr+₹10.6 L (5.70%)Admitted-Finance | ₹2.0 Cr+₹10.6 L (5.70%) | L4 | Admitted-Finance |
| 5 | L5₹2.1 Cr+₹21.7 L (11.7%)Admitted-Finance | ₹2.1 Cr+₹21.7 L (11.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | JAYRAM INDUSTRIES INDIA PRIVATE LIMITED L1 | SHRADDHA ENGINEERING AND FACILITY SERVICES L2 | JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED L3 | CHENNAI ENGINEERING SERVICES L4 | PAN POLAR ENGINEERS PVT. LTD. L5 | JAI ENTERPRISES L6 | ABHISHEK ASSOCIATES L7 | DElite System Engineering (India) Pvt. Ltd. L8 | VOLTAS LIMITED L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Operation and Maintenance of E & M Installations at MSSR building and DVOR Building on Yarada Hills by carrying out preventive maintenance, attending to the complaints & maintaining records by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
(Note: Rs. 1000/- extra to be paid to each employee in addition to the minimum wages towards conveyance charges being remote site). | 24 | Months | - | - | - | - | - | - | - | - | - |
| 2.00 | Operation and Maintenance of E & M Installations at residential colony, WT station & new CISF barracks at new Karasa by carrying out preventive maintenance, attending to the complaints by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required. | 24 | Months | - | - | - | - | - | - | - | - | - |
| 3.00 | Filtration of oil of the following equipments to the required di electric strength, testing the same for the break down voltage. Performing acidity test at site by arranging the oil filtration machine andother testing equipments at site, cleaning and drying out the brether etc including cleanbing the transformer completely and arresting the leak if any by providing gasket and tightening the bolts etc required.
a) 200KVA Transformer Kirloskar make at SSI (250 litre capacity)
(Location of Transformers is at Yarada Hills). | 4 | Job | - | - | - | - | - | - | - | - | - |
| 4.00 | Supply of transformer oil with test report for topping up the transformer including transportation as and when required. | 80 | ltr | - | - | - | - | - | - | - | - | - |
| 5.00 | Supply and replacement of Silica gel crystals for transformer breather including removing the detoriated one and refilling the new crystal etc as required. | 24 | Kg | - | - | - | - | - | - | - | - | - |
| 6.00 | Transportation of HSD oil from Airport power house / petrol bunk to MSSR at yarada hills. Approx. quantity of oil to be transported upto 800 ltrs in a single trip up an down. Approx. distance from the starting point is 20 Km. (approx. 5 Km travelling is on hill). Excluding loading and unloading. | 24 | Job | - | - | - | - | - | - | - | - | - |
| 7.00 | Spray painting of LT panels / feeder pillars with one coat metal primer on rusted surface and two coats approved synthetic enamel paint i/c scraping the surface, lettering etc., as required upto the satisfaction of the Engineer-in-charge as and when required. | 200 | sqm | - | - | - | - | - | - | - | - | - |
| 8.00 | Painting of street light poles with one coat of metal primer on rusted surface and two coats of approved aluminum paint i/c dismantling, re-fixing of fittings and scraping the surface as required to the satisfaction of the Engineer-in-charge as and when required.
(a) Poles of height from 3 mtrs to 9 mtrs | 20 | each | - | - | - | - | - | - | - | - | - |
| 9.00 | Re-winding of following rating sub-mersible pump motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the submersible pump motor set to the site etc as and on when required.
a) upto 5.0 HP | 2 | Job | - | - | - | - | - | - | - | - | - |
| 10.00 | Lifting of following submersible pumps upto 200 feet from the existing bore well / open well along with GI / MS pipe lines, cable and reinstallation of the same after repair / rectification of the defects as and when required.
(Charges for repair / rectification of the pump or motor is not included).
a) upto 5.0 HP | 2 | Job | - | - | - | - | - | - | - | - | - |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
11 Feb 2020, 6:00 pmClosed
AGM ELECTRICAL VISAKAPATANAM
O/o AGM ELECTRICAL AAI VISAKHAPATANAM AIRPORT
ARMO of Electrical and Mechanical Installations 2020-22 at Visakhapatnam Airport
2020_AAI_40717_2
AAI/VZ/ENGG(E)/RM/ENIT14/19-20
Open Tender
Electrical Works
Item Rate
730 days
VISAKHAPATNAM
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
Yes
AIRPORTS AUTHORITY OF INDIA
₹4.4 L
Yes
24 Feb 2020
30 Jan 2020
18 Feb 2020
30 Jan 2020
11 Feb 2020
30 Jan 2020
30 Jan 2020 - 11 Feb 2020
Amount
Operation and Maintenance of E & M Installations at MSSR building and DVOR Building on Yarada Hills by carrying out preventive maintenance, attending to the complaints & maintaining records by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required. (Note: Rs. 1000/- extra to be paid to each employee in addition to the minimum wages towards conveyance charges being remote site).
Operation and Maintenance of E & M Installations at residential colony, WT station & new CISF barracks at new Karasa by carrying out preventive maintenance, attending to the complaints by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
Filtration of oil of the following equipments to the required di electric strength, testing the same for the break down voltage. Performing acidity test at site by arranging the oil filtration machine andother testing equipments at site, cleaning and drying out the brether etc including cleanbing the transformer completely and arresting the leak if any by providing gasket and tightening the bolts etc required. a) 200KVA Transformer Kirloskar make at SSI (250 litre capacity) (Location of Transformers is at Yarada Hills).
Supply of transformer oil with test report for topping up the transformer including transportation as and when required.
Supply and replacement of Silica gel crystals for transformer breather including removing the detoriated one and refilling the new crystal etc as required.
Transportation of HSD oil from Airport power house / petrol bunk to MSSR at yarada hills. Approx. quantity of oil to be transported upto 800 ltrs in a single trip up an down. Approx. distance from the starting point is 20 Km. (approx. 5 Km travelling is on hill). Excluding loading and unloading.
Spray painting of LT panels / feeder pillars with one coat metal primer on rusted surface and two coats approved synthetic enamel paint i/c scraping the surface, lettering etc., as required upto the satisfaction of the Engineer-in-charge as and when required.
Painting of street light poles with one coat of metal primer on rusted surface and two coats of approved aluminum paint i/c dismantling, re-fixing of fittings and scraping the surface as required to the satisfaction of the Engineer-in-charge as and when required. (a) Poles of height from 3 mtrs to 9 mtrs
Re-winding of following rating sub-mersible pump motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the submersible pump motor set to the site etc as and on when required. a) upto 5.0 HP
Lifting of following submersible pumps upto 200 feet from the existing bore well / open well along with GI / MS pipe lines, cable and reinstallation of the same after repair / rectification of the defects as and when required. (Charges for repair / rectification of the pump or motor is not included). a) upto 5.0 HP
Lifting of following submersible pumps upto 200 feet from the existing bore well / open well along with GI / MS pipe lines, cable and reinstallation of the same after repair / rectification of the defects as and when required. (Charges for repair / rectification of the pump or motor is not included). b) above 5.0 HP and upto 7.5 HP
Re-winding of following rating monoblock pump motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the monoblock pump motor set to the site etc as and on when required. a) upto 5.0 HP
Operation of Lifts & Escalators in Integrated Terminal building by providing trained manpower including keeping the machines in neat and tidy condition by cleaning, monitoring and co-ordinating with OEM service persons for ensuring serviceability/ satisfactory working, rescue of users in case of requirement, maintaining the records etc. in two shifts per day including Sundays & holidays etc. as per enclosed Special conditions of contract, Particular specifications, and as per the instructions of Engineer-in-Charge or his authorised representative from time to time complete as required.
Operation and Maintenance of Sewage Treatment Plant System by carrying out preventive maintenance, attending to the complaints, maintaining records by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
Supply of following Chemicals for day to day operation of Sewage Treatment Plant. a) Chlorine
Supply of following Chemicals for day to day operation of Sewage Treatment Plant. b) Urea
Supply of following Chemicals for day to day operation of Sewage Treatment Plant. c) DAP
Supply of following Chemicals for day to day operation of Sewage Treatment Plant. d) Nutrients
Carrying out of following tests of sewage Inlet & treated water sample in reputed testing lab and submitting of bimonthly report including to & fro transportation to the site., etc complete job as required. (a) PH (b) TDS (c) TSS (d) BOD (e) COD (f) Chlorides (g) Sulphates
Replacement of sand and stone aggregate (20 mm) in the filter bed once in year by providing river sand stone aggregate and disposing of digged out sand / agreegate within a lead of 50 metre as direction of Engineer-In-Charge.
Rewinding of 7.5KW, 415V, 3 Ph induction motor by dismantling, cutting of burnt out wire rewinding with new winding with suitable guage enamelled copper wire, varnishing, baking, re-assembling of set including to and fro transportation to the site etc., complete job as on when required.
Complete repair & overhauling of Twin lobe blower of capacity 230 cfm,6 psi suitable to work on 7.5KW, 415V, 3 Ph induction motor by dismantling, replacement of neccessary spares such as , shaft, blades, bushes,..etc if required including lubricating on the parts wherever required and re-assembling of set including to and fro transportation to the site,dremoving & Refixing, testing,commissioning etc., complete job as on when required.
Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required. a) 1 HP , 1- Phase Submersible motor
Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required. b) 3 HP , 3-Phase submersible motor
Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required. c) 5 HP , 3- Phase submersible motor
Replacement of worn out / broken pully rubber belt of size B60 of blower motor etc., complete as on when required.
Annual Maintenance contract of Solar Powered Obstruction lighting system at 11 different locations on hill tops around Visakhapatnam Airport by carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule, Special conditions of contract and Particular specifications etc. complete as required. (Spares shall be supplied by AAI).
Supply of 12 V Flasher cards (Tech 31 model) for existing Solar Powered Obstruction lighting system Make : Avaids Technovators Pvt. Ltd.
Supply of Battery Charger (Pro star 30) for existing Solar Powered Obstruction lighting system Make : Avaids Technovators Pvt. Ltd.
Supply of Medium intensity light Unit ( AWL Model:TASS-MI-XLL) for existing Solar Powered Obstruction lighting system Make : Avaids Technovators Pvt. Ltd. suitable for operating at 12V D.C.
Supply of 12V/300Ah battery bank (6 No. x 2V VRLA battery) for existing Solar Powered Obstruction lighting system
Supply of 12V, 75 WP solar Modules for existing Solar Powered Obstruction lighting system Make : Avaids Technovators Pvt. Ltd.
Annual Maintenance of Fire hydrant & sprinkler system of Terminal Building by carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule, Special conditions of contract and Particular specifications etc. complete as required. The contractor shall engage minimum man power per day as per the particular specifications.
Comprehensive Maintenance contract of the intelligent addressable type Fire Detection and Alarm system alongwith all its associated accessories installed at MSSR building at yarada hills, by carrying out complete comprehensive maintenance, providing spares etc., & carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule & OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required. i. Quick Start Fire alarm panel - 1 no. ii. Smoke detector - 40 nos. iii. Heat detector - 2 nos. iv. Manual call point - 5 nos. v. Hooter - 5 Nos. a) 1st year
Comprehensive Maintenance contract of the intelligent addressable type Fire Detection and Alarm system alongwith all its associated accessories installed at MSSR building at yarada hills, by carrying out complete comprehensive maintenance, providing spares etc., & carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule & OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required. i. Quick Start Fire alarm panel - 1 no. ii. Smoke detector - 40 nos. iii. Heat detector - 2 nos. iv. Manual call point - 5 nos. v. Hooter - 5 Nos. b) 2nd year
Comprehensive Maintenance contract of the conventional type panel with auto dialler, Fire Detection and Alarm system alongwith all its associated accessories installed at various locations viz., CNS equipment rooms, Power house locations by carrying out complete comprehensive maintenance, providing spares etc., & carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule & OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required. No. of devices connected to each individual control panel are detailed in Particular Specifications. a) 1st year
Comprehensive Maintenance contract of the conventional type panel with auto dialler, Fire Detection and Alarm system alongwith all its associated accessories installed at various locations viz., CNS equipment rooms, Power house locations by carrying out complete comprehensive maintenance, providing spares etc., & carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule & OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required. No. of devices connected to each individual control panel are detailed in Particular Specifications. b) 2nd year
DSR 2018 item for Rs. 2,00,000/- per year. [Note : The rate may be quoted in the following manner - (i) If quoted rate is Rs. 1,78,580/- then the percentage will considered as 0% above / below DSR 2018. (against Rs. 2,00,000/-) (ii) If quoted rate is Rs. 1,60,722/- then the percentage will considered as 10% below DSR 2018.(against Rs. 2,00,000/-) (iii) If quoted rate is Rs. 1,96,438/- then the percentage will considered as 10% above DSR 2018.(against Rs. 2,00,000/-) a) 1st year
DSR 2018 item for Rs. 2,00,000/- per year. [Note : The rate may be quoted in the following manner - (i) If quoted rate is Rs. 1,78,580/- then the percentage will considered as 0% above / below DSR 2018. (against Rs. 2,00,000/-) (ii) If quoted rate is Rs. 1,60,722/- then the percentage will considered as 10% below DSR 2018. (against Rs. 2,00,000/-) (iii) If quoted rate is Rs. 1,96,438/- then the percentage will considered as 10% above DSR 2018. (against Rs. 2,00,000/-) b) 2nd year
SHRADDHA ENGINEERING AND FACILITY SERVICES
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
CHENNAI ENGINEERING SERVICES
PAN POLAR ENGINEERS PVT. LTD.
JAI ENTERPRISES
ABHISHEK ASSOCIATES
DElite System Engineering (India) Pvt. Ltd.
VOLTAS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.08 MB
TenderDocumentmssr.pdf
Tender Documents • 7.07 MB
BOQ_44751.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .