Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.5 L+₹3.5 L (8.80%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.2 L+₹5.2 L (13.0%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹46.5 L+₹6.5 L (16.3%)Rejected-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹46.5 L+₹6.5 L (16.4%)Rejected-AOC BYPASS ROAD BESIDE YUG BAJAJ SHOWROOM GARIBICHOK PORBANDAR 360577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
13 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
ADDITION/ALTERATION TO MI ROOM AT CGDHQ NO-1 PORBANDAR UNDER GE I CG PORBANDAR
2022_MES_519532_1
8749
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹79,000
Yes
25 May 2022
23 Apr 2022
14 May 2022
23 Apr 2022
13 May 2022
7 May 2022
23 Apr 2022 - 6 May 2022
60 days
Amount
SCHEDULE 'A'
Demolition of cement concrete( reinforced( reinforcement cut as required to faciliate demolition) of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L Reinforced cement concrete type A1 1:1.5:3 (20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface
Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc.
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.
-ditto- all as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders
M&L for 40 mm thick Plain Cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in sub base of floors and over a roof slab all as specified
M&L for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds complete all as specified and as directed.
M & L Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth wiithout using extra cement.
M&L Rendering on ceiling 5 mm thick in CM 1:3 on brick work or concrete surfaces finished fair and even without using extra cement.
M&L Two coats of OBD on new plastered surfaces of wall over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L Two coats of OBD on new plastered surfaces of ceiling over a coat of chalk white primer including preparation of newly plastered surfaces complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof acrylic exterior emulsion paint over a coat of acrylic primer all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
Writing letters or figures (Block, Roman, Italic or Indian) exc 30 cm but not exc 45 cm high with stainless steel incl chiselling for letters on granite surfaces.
M&L 20mm thick cement plaster in cement mortar 1:4 mixed with 2% of water proofing compound as in roof treatment when conc is green complete all as specified and directed.
M&L APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
M & L for powder coated Aluminium frame and shutter for sliding & openable, door, windows, partation & ventilators (movable louvers type) with one or more rebates including joining cleats for fixing etc. Rubber gasketting all round the panels / shutters to fix glass, PVC gasketting in all channels, locking arrangement, (minimum thickness of powder coating 60 micron for windows, door, partation and ventilators with natutal matt fininsh) complete all as specified and directed. [Note :- (i) Glass to be measured and paid separately under respective of work. (ii) Items shall be paid as per weight of aluminium section. (iii) The quoted rate shall be inclusive of rubber gasket/ PVC gasket, glazing clips, screws etc as required which shall not be measured for arriving the weight. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel arround contacting surface of aluminium work]
S & F Aluminium anodised grill (thickness of anodising minumum 15 micron) with and including suitable aluminium anodized 'F'/ 'H' section frame 23.40 x 15.30 x 1.40 mm thick with aluminium rebated/ screwed attachment complete all as specified and directed in following situation :- (Note : (i) Aluminium grill shall be of 'Deco grill' of M/s ELESAR FOCCHI Ltd as per Design No. DG102, 7.50 mm x 6 mm and weight shall not be less than 3.131 Kg/ Sqm or approved design in M/s Royal Grill/ National Grill/ Alumigrille of M/s Alumi Profiles Pvt. Ltd, Chandramukhi Basement, Nariman point, mumbai.
S&F Float glass 5.5mm thick plain provided to aluminium frame for door/window/partition with necessary aluminium powder coated snap beading and rubber gasket/packing complete all as specified and directed by Engr-in-Charge
S & F 4mm thick both side aluminuium decoretive sheet laminated partation pannel for door shutter / Partation with necessary aluminium powder coated snap beading and rubber gasket/packing complete all as specified and directed by Engr-in-Charge
S&F Aluminium xpm wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beads complete as specified and directed by EIC.
M&L Virified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and hite or coloured cement to match not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match as in floor including dismantling complete all as specified and as directed by the Engineer-in-Charge. Make:- Somani ,Orient Bell, kajaria.
All as item above but over screed bed or bedding layer 10mm thick 1:4 on vertical surfaces/skirting complete all as specified and as directed
M & L Glazed ceramic tiles in vertical surfaces 300x450mmx7mm thick including over 10mm thick rendering of cement mortar (1:4) for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge. Make:- Somani ,Orient Bell, kajaria.
S&F Stainless steel pipe of grade 316, of any dia for railling / balusters over existing parapet including base, collars, caps, head caps and anyother specials etc including necessary welding, polishing and drilling in masonary and filling with epoxy grout etc including taking out old SS railing and removing to store complete all as specified and directed by Engineer in charge.
M&L for Polished granite stone slab 16 to 18mm thick (table rubbed and polished) in steps, jambs, pillar, window cills, cooking platform and like in cement mortar 1:4 incl pointing in white cement 1:2 using marble dust with admixture pigment to match with shade of granite including moulding at front edge all as specified and as directed as in platforms Note : Quality of granite all as approved by GE .
S&F aluminium decorative type powder coated brackets suitable for 20mm dia curtain rod or similar articles and completed all as specified and directed.
S&F 20mm dia aluminium decorative type powder coated curtain rod or similar articles and completed all as specified and directed by Engineer in charge.
S&F door stopper aluminium anodized white dale 40mmx40mm and 2mm thick dia 150mm having rubber bash 25mm dia long (high) at end the sheet/fixed to door shutter with steel cadmium places scrrew all as specified
M&L for 12mm thick Gypsum Board seamless Ceiling as in curved, sunken or raised surface of any design as approved and finishing the surface fair by filling the joint with POP and inlcuding GI frame work for curved, sunken or raised for any design as approved as in ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre fixed with hanger of GI channel made out of GI channel used in ceiling as above upto 1200 mm length in roof slabs by means of ceiling cleats complete all as specified and directed by Engr-in-charge Note :- Flat area will be measured.
M&L for 12mm thick Gypsum Board seamless Ceiling as in flat surface, finishing the surface fair by filling the joint with POP and inlcuding GI frame work as flat surface approved as in ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre fixed with hanger of GI channel made out of GI channel used in ceiling as above upto 1200 mm length in roof slabs by means of ceiling cleats complete all as specified and directed by Engr-in-charge
M & L Preparing new/old plastered / decorated surface of wall including cornices etc by brooming down and applying two coats of oil bound distemper including a wherever requred of wall putty including smooth roller finish complete all as specified and directed by Engineer in Charge. (Note after painting cleaning of all floors,glass & furniture by own arrangement).
M & L Preparing new/old plastered / decorated surface of ceillingl including cornices etc by brooming down and applying two coats of oil bound distemper including a layer of wall putty including smooth roller finish complete all as specified and directed by Engineer in Charge. (Note after painting cleaning of all floors,glass & furniture by own arrangement).
Disconnecting existing PVC tanks, Exc 1000 & n exc 2000 lit capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position at hight up to 4mt (Cleaning repairing etc. measured separately).
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20 mm dia complete all as specified and as directed by Engr-in-Charge
Supply and laying of CPVC pipes, of 25mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia ) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all asper manufacturers recommendations and complete all as specified and as directed by Engr-in-Charge
Taking down carefully aluminium/copper point wiring (light,fan,socket or power) concealed and casing caping complete including fittings and fixtures such as switches,ceiling roses,pendants,regulators,sockets light fittings and making good the disturbed surfaces of walls/ceiling/floor etc.
Disconnecting of unserviceable sub main wiring of any size and accessories & removing from site and making good the disturbed surfaces.
Disconnecting electric connections and taking down old unserviceable MCB SPN/SP/TP and DB's of any capacity.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty (minimum 20 mm dia external ) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate, frame and modular switch mounting plate of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- Make RR Cables/ Anchor/Polycab
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
One bell/ buzzer point controlled by one push button on the same board with other switches or independent
One light point controlled by two two way switch
M&L for Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit concealed conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate, frame and modular switch mounting plate of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- Make RR Cables/ Anchor/Polycab
Point wiring complete with 4 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed oncealed/recessed in wall or ceiling etc including 4.0 Sq mm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire including modular metal flsuh box with cover plate and frame of required moudule for mounting of modular switches, sockets, switch sockets one 3 pin 15 or 16 Amps socket outlet on independent board as specified. with required modules all as specified etc for:-
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed Make /Legrend/ Berkar/L&T
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make /Legrend/ Berkar /L&T
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make /Legrend/ Berkar /L&T
Supply & fix modular switch 1 way2 Modular switch 2 way 6A, 1 module (ISI marked).complete all as specified and as directed Make /Legrend/ Berkar/L&T
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make /Legrend/ Berkar/L&T
Supply & fix Bell Multi Music type 230 Volt complete all as specified and as directed Make /Legrend/ Berkar/L&T
Supply & fix modular Modular Bell push 6A 1 module complete all as specifed and as directed Make /Legrend/ Berkar/L&T
Supply & fix modular fan regulator, 120 watt, 2 moduler (ISI marked).complete all as specified and as directed. Make /Legrend/ Berkar/L&T
Supply & fix ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked) complete all as specified and as directed Make /Legrend/ Berkar/L&T
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro cat Part No LL20-281-XXX65AL1** /GE
S & F in of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-111-XXX-65NE3* or equivalent to Bajaj/Havells
Supply & fix LED down lighter, Mollis (LD 06 ) Luminaries of 18 W CCT 5700(K) 230 Volt including connecting with flexible cable connection to fiitings connector complete all as specifed and as directed Make Cat Ref NO LD 06X-221-XXX-57-XX** of Wipro/Philips/GE
Supply and fixing LED Bldg Security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete Make LR 02-291-XXX-57-XX Wipro/ GE/Philips
S&F LED universal mounted 60 cm X 60 cm luminaire,240V, 50Hz, Nominal Lumen output 3000 lm, THD<20%, PF>0.95 Square in shape, complete all as specified and as directed by Engr-in-Charge, fixed in repair by replacing any type of fitting. Make: Philips/ Wipro/GE
S & F BEE BLDC energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: CG/Orient/USHA
Supply and fix Exhaust fan 300 mm sweep 240 V AC metal body fixed as per maufacturers instruction, connecting with and including 2 core x 0.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete or equivalent. Make Orient,/CG /Usha
M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit exsisitng/ Provision with new conduit with all accessories, PVC insulated 4 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Make Polycab/ RR Cables/ ANCHOR Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L for sub main wiring with two single core 6 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit exsisitng/ Provision with new conduit with all accessories, PVC insulated 6 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Make Polycab/ RR Cables/ ANCHOR Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L for sub main wiring with two single core 10 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit exsisitng/ Provision with new conduit with all accessories, PVC insulated 10 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Make RR Cables/ Anchor/Polycab Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
S & F single pole & neutral DB (double door), conforming to IEC 61439- 3, suitable for flush mounting with 100 A insulated & shrouded copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wire set and cable ties for cable management, IP 43 & IK 09 protection with provision for DP RCBO as incomer and SP MCBs as outgoing, all complete as specified and directed.as per following
Single Pole & Neutral DB, 12 Way
Single Pole & Neutral DB, 8 Way
S&F DB VTPN, 4Way, Double Door, IP43 protection with connected accessories like insulated bus bars, insulated IP2X neutral bars and earth Bars, blanking plates, cable management kit, incoming as MCCB and outgoing SP/TP MCB all as specified and directed. Make Legrend/ ABB/C&S
Supply and fixing MCCB 3 Pole .415 V. fixed type, 125 Amps with breaking capacity 16 KA complete all as specified and as direced Make Legrend/ ABB/C&S
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.Make Legrend/ ABB/C&S
MCB SPN 63 Amp
MCB SPN 40 Amp
MCB SP 63 Amp
MCB SP 40 Amp
MCB SP 6 TO 32 Amp
Supply and fix 20 Amps power unit with four module plate 20 Amps socket including flush metal GI Box complete all as specified and directed. Make : Legrand/ L&T/ ABB/Havells
M&L Earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, buried directly and preferable vertically in ground with top edge not less than 1.25 metres below gound level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No 2 to the earthing test point all as specified and indicated including testing on completion all as specified and directed. Note : Cost of earth GI pipe for protection of eath strip deemed to be included in unit rate upto 7.5 meter.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
M & L for taking down indoor and outdoor unit of split type ac 1.5 Ton capacity and window ac 1.5 ton capacity from location and refixing on same location complete all as specified and as directed Note : For Split top up of refrigerant and other accessories such as nut bolt screw indoor and outdor unit fixing new frame and new stand , insulation copper pipe for inlet and outlet is deemed tobe included in unit rate.
S&F 19mm dia Rigid non-metallic PVC conduit inclusive of junction boxes (1 to 4 way), medium duty, including all Tees, bends, elbows, reducers, bell mouth tube ends, and fixing couplers, lock nuts, saddles, pipe hooks etc, fixed in repairs
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches with all fittings of OD 32 mm dia complete all as specified. Make
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
S & F CPVC ball valve of size of 32 mm dia with iron complete all as specified and directed.Make
M & L for cutting of existing DI/CI Pipe in position for inserting CI Tee complete with 50 mm dia union, nipple, etc all as directed for taking 32 mm CPVC branch line
M & L for Construction of new valve chamber of size 600 X 600 X 600 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works & two coats of white wash on all plastered surfaces of valve chambers complete all as specified and directed.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 70 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed.Make Havells/ Polycab/ RR Cables
S & F of GI steel tubing light grade 80 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc all as specified and directed. Make - Tata/Jindal/Surya Prakash
Supply and lay 63 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.Make Gemini/Rex/Poly
M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
M/S. P.M GODHANIYA
SURAJ ENTERPRISE
K B N TRADERS
M/S Unicon Engineering co
Vijay Construction Co
SANVI ASSOCIATES
RAJ ENTERPRISE
Gatral Construction Co.
roxy enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .