| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.9 L+₹62,125.67 (6.67%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹10.9 L+₹1.6 L (17.5%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
31 Dec 2024, 6:00 pmClosed
Harikesh Meena EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2024_MES_686303_1
8830
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BARODA
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE ARMY BARODA
₹20,000
Yes
1 Mar 2025
29 Nov 2024
5 Jan 2025
29 Nov 2024
31 Dec 2024
13 Dec 2024
30 Nov 2024 - 7 Dec 2024
Amount
Taking out LT cable from trenches / pole etc, aluminium conductor of size 16 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 25 sqmm 4 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 35 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 50 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 70 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 185 sqmm 3.5 core all as specified and directed.
Taking out LT cable from trenches / pole etc, aluminium conductor of size 240 sqmm 3.5 core all as specified and directed. No.1.00 to 9.00) Excavation and earth work and taking out old cable cover will be measured and paid separately.
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 16 sqmm 4 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 1 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 25 sqmm 4 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 2 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 35 sqmm 3.5 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 3 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 50 sqmm 3.5 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 4 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 70 sqmm 3.5 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 5 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 95 sqmm 3.5 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 6 above shall be reused
Laying only old LT cable in trenches / pole etc, aluminium conductor of size 120 sqmm 3.5 core all as specified and directed. Note:- Serviceable Cable retrieved from item No 7 above shall be reused
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 185 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 240 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 300 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Excavation ii trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for laying / taking out of cables and for erecting of poles and getting out in soft / loose soil ( removing and replacing Inter loking tiles if necessary shall be measured and paid as excavation in soft/ loose soil) all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning below and above underground cable, thickness as specified in SSR including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be considered.
Taking out old PCC cable cover of any type / any size from trenches all as specified and directed.
Laying only PCC cable cover for LT UG cable, of any description , all as specified and directed by Engr-in-Charge. Note:- Serviceable Cable cover retrieved from item No 31 above shall be reused
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat, size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
Supply and laying in trenches, in road cutting GI tubing 40 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings including cutting road if required and making good with PCC work including taking down old tubing complete all as specified and directed.
Supply and laying in trenches, in road cutting and along with GI tubing 80 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings ncluding cutting floor/path/road if required and making good with PCC work including taking down old tubing complete all as specified and directed.
M&L in replacment of MCCB, 4 pole, 415 Volts, 63 Amps, 16 KA, 50 Hz, AC fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.Make:HAVELLS/L&K/Legrand
M&L in replacment of MCCB, 4 pole, 415 Volts, 100 Amps, 16 KA, 50 Hz, AC fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.Make:HAVELLS/L&K/Legrand
M&L in replacment of MCCB, 4 pole, 415 Volts, 125 Amps, 16 KA, 50 Hz, AC fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.Make:HAVELLS/L&K/Legrand
M&L in replacment of MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC adjustable in existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed.Make:HAVELLS/STANDARDB
M&L in replacment of MCCB, 4 pole, 415 Volts, 200 Amps, 35 KA, 50 Hz, AC Adjustable in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacment of MCCB, 4 pole, 415 Volts, 250 Amps, 35 KA, 50 Hz, AC Adjustable in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
Disconnecting existing LT Panel & raising the panel of any size by providingPCC 1:3:6 type C1 of existing matching size upto the hight of 1.2 mtr from GL,and connected complete duly welding work painting of LT panel inner portion and outer portion including necessary lubrication should be made and complete all as specified and directed by Engineer-in- Charge.Note:- (i) All items reqd for raising the panel viz angle iron/cement /aggregate/sand/bricks welding work etc is deemed to be incuded in the rate quoted. (ii) Any LT UG cable required wil be measured and paid separatel.
cutting vegetation on and around existing LT Panel board upto 1 mtr distance of surrounding area complete including making LT panel doors serviceable by welding work if any required all as specifed and directed by Engr-in-charge. Note:- All existing panel to be maintained properly as directed by JE/AGE.
S&F in repair LT cable jointing kit for 1.1 KV grade cable for staright through joint complete with jointing material(Epoxy based) and accessories suitable for 3 .5 Core XLPE armoured Al cable of size as under : Note: (a) Excavation and earth work required for cable joint and refilling is deemed to be incuded in the quoted rate.
25 to 50 Sqmm
25 to 50 Sqmm
70 to 95 Sqmm
120 to 185 Sqmm
(Note: Item no 1 to 45 If any above LT cables and connected itms become breakdown, the contractor shall loacate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault and rectified within 24 to 48 Hours , failing which an amount of Rs 200 /- per hour will be recovered as penal recovery from any payment due to the contractor after expiry of 48 hours.)
PATELS (BID ID -3193009)
P K SHETH (BID ID -3201025)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .