| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC NEW AZAD NAGAR IDGAH MOHALLA BISHUNPUR B POLYTECHNIC DHANBAD DHANBAD 828130 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828130 | ₹5.2 L | L1 | Accepted-AOC AOC ACCEPTED |
| 2 | L2₹5.3 L+₹9,841.20 (1.89%)Rejected-Finance | ₹5.3 L+₹9,841.20 (1.89%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹5.6 L+₹34,443.62 (6.60%)Rejected-Finance ANGARPATHA KATRASGARH DHANBAD | DHANBAD | DHANBAD | JHARKHAND | 828113 | ₹5.6 L+₹34,443.62 (6.60%) | L3 | Rejected-Finance REJECTED |
Tender Value
₹4.9 L
EMD Value
₹6,200
Closing Date
27 Mar 2026, 6:00 pmClosed
AM (EnM), PB AREA
PB AREA, PUTKI
Rectification and Maintenance of G.T feeder 11 KV O/H line, main feeder from 132 KV S/S 11 KV O/H line, 4-Pit Central Balihari LT, Shifting of S/S, Store work and 3.3 KV O/H line maintenance.
2026_BCCL_356949_1
BCCL/PBA/AM(EnM)/2025-26/122 DATED-17.03.2026
Open Tender
Electrical and Maintenance Works
Percentage
7 days
KB 5/6 PIT (HMP) COLLIERY
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,200
6 Apr 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
27 Mar 2026
17 Mar 2026
17 Mar 2026 - 20 Mar 2026
Item Description/ Heading
A) FOR 4-Pit Central Balihari LT O/H line maintenance - Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Dismantle of pole (CPWD SOR' 2012, P-40, 12.42)
Transportation of dismantled pole from site to store
Transportation of pole from store to site
Erection of metallic pole of 8 to 10 metre length (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply & Erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
B) FOR G.T feeder 11 KV O/H line maintenance -Transportation of Pole at site
Erection of metallic pole of 10 to 12 metre length (CPWD SOR' 2012, P-36, 11.3.4)
Fabrication & erection of bracket & clamps
Supply and erection of MS Nut & Bolts
Supply & erection of 11 KV Disc insulator (CPWD SOR' 2012, P-42, 13.11)
Supply & erection of 11 KV Pin insulator (CPWD SOR' 2012, P - 42, 13.10)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
Making new jumper with O/H line for back feed to Patch-B
Dismantle of jumper from O/H line
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Transportation of cable 240 sq mm 30 mtrs from Regional store
Laying/Hanging of two nos PVC insulated power cable of 240 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2) 30 + 150 = 180 mtrs
Supplying and making straight through cable jointing with cast resin compound (CPWD SOR' 2012, P-34, 10.3.3)
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 240 sq mm size (CPWD SOR' 2012, P-34, 10.2.3)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete (CPWD SOR' 2012, P-35, 10.5.3)
Opening jumper for searching faults & after megguring re-jumpering
Jumper dismantle of BCW for Patch-B power supply
Tree & branches cutting below O/H line (Semi Skilled)
Damage & weak jumper repairing with binding wire etc.
Opening burnt cable jumper from O/H line
Taking down of one no. PVC insulated power cable of 11 KV grade of 185 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Excavation of one no. PVC insulated and PVC sheated/XLPE power cable of 11 KV grade of 185 sq mm from ground (CPWD SOR' 2012, P-28, 8.1.2)
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185 sq mm size (CPWD SOR' 2012, P-34, 10.2.3)
Laying/Hanging of one no. PVC insulated power cable of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Jumpering above cable after pole mounting with O/H line
Opening jumper for changing of faulty Disc insulator
Making jumper after changing faulty Disc
C) FOR main feeder from 132 KV S/S 11 KV O/H line maintenance - Erection of cradle guard with 8 no. G.I wire
Opening jumper for searching faults & after megguring re-jumpering
Opening jumper for changing of faulty Disc insulator
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Supply & erection of 11 KV Disc insulator (CPWD SOR' 2012, P-42, 13.11)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making jumper after changing of faulty Disc
Damage & weak jumper repairing with binding wire etc.
Tree & branches cutting below O/H line (Semi Skilled)
D) FOR Shifting of S/S work - Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication and erection of bracket & clamps
Supply and erection of MS Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators (CPWD SOR' 2012, P-39, 12.17)
Supplying and erection of Stay set complete (galvanised) (CPWD SOR' 2012, P-41, 13.1)
Erection of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Road cutting for laying pipe to pass cable from the pipe with hilty machine fair
Tree & branches cutting below O/H line (Semi Skilled)
Laying/Hanging of three nos PVC insulated power cable of 240 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2) 40 + 40 + 40 = 120 mtrs
Supply & making indoor cable end jointing including lugs and other jointing materials for 240 sq mm (CPWD SOR' 2012, P-34, 10.1.3)
Laying/Hanging of three nos PVC insulated power cable of 11 KV grade of 120 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.1) 30 + 30 + 30 = 90 mtrs
Laying/Hanging of two nos PVC insulated power cable of 11 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.1) 40 + 30 = 70 mtrs
Supply & making indoor cable end jointing including lugs and other jointing materials for 70 sq mm (CPWD SOR' 2012, P-34, 10.1.1)
Electrical cable joint with lugs, HT Tape & other jointing materials
E) FOR Store work - Transportation of Dog conductor (1000 + 1000 + 500 mtrs in 3 days) from Regional Store 5 heads * 3 days = 15 heads
Iron cutting by grinder for making bracket & clamps
Transportation of 40 mtrs 240 sq mm cable from regional store
F) FOR 3.3 KV Office O/H line maintenance - Damage & weak jumper repairing with binding wire etc.
Tree & branches cutting below O/H line (Semi Skilled)
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.71 MB
BOQ_369813.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .