GEMC-511687794336712
Awarded to SOHAM IMPEX
₹2.0 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| AIR PLSMA CUTTING MACHINE 25MM | SI-APC-25 | - | 1 NOS | ₹2.0 L | 198,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.0 LQualified Make: SOHAM
Model: SI-APC-25 PROP SOHAM IMPEX SOHAM 7 BACK BONE PARK B H BALAJI HALL 150 FEET RING ROAD RAJKOT GUJARAT 360002 | RAJKOT | GUJARAT | 360002 | Make: SOHAM
Model: SI-APC-25 | L1 | Qualified | |
| 2 | L2₹2.0 L+₹500 (0.25%)Qualified Make: J K
Model: JK-APC-25 8 MAVADI PLOT NEAR SURAJ BESAN RAJKOT CITY GUJARAT 360004 | RAJKOT | GUJARAT | 360004 | Make: J K
Model: JK-APC-25 | L2 | Qualified | |
| 3 | L3₹2.0 L+₹2,000 (1.01%)Qualified Make: DUO
Model: DMC-APC-25 OPP BALAJI HALL RAJKOT RAJKOT GUJARAT 360005 | RAJKOT | GUJARAT | 360005 | Make: DUO
Model: DMC-APC-25 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Jul 2018, 10:00 amClosed
plasma air cutting machine Plasma Air Cutting Machine ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Performance Parameters Power Sources IGBT Based IGBT Based
Transformer Based Type of metal which can be cut All (MS
SS
Brass
Copper
Aluminium) Stainless Steel
Alumini um
All (MS
Aluminium)
Mild Steel Material Removing rate (Kg/Hr) 25 Current Range (in Amp) 10-100 10-40
10-55
10-100
20- 150 Max open circuit Voltage in (Volt) 280-320 - Current Rating of Power Source at 100% Duty cycle in ampere 100 Current Rating of Power Source at 60% Duty cycle in ampere 60 Current Rating of Cutting Torch at 100% Duty cycle in ampere 100 1/5 Current Rating of Cutting Torch at 60% duty cycle in ampere 60 Efficiency of Machine (%) 85 80
85
90 Insulation Class H - Type of Air Compressor Reciprocating Type Reciprocating Type
Centrifugal Type Make of Air Compressor - - Type of Gas Supply to Power Source - - Motor Power for Air Compressor (Single Phase ) in HP 5 - Air Flow Rate
Maximum (in kg/cm2) - - Type of Cooling Forced Air - Type of Torch Hand Held Based - Maximum Clean Cut Thickness (in mm) 25 6
12
25
50 Output Current Range
DC Amp 80-100 35-40
45-55
80-100
12 0-150 Rated input Range kVA (KVA) 15-20 5-7
7-10
15-20
25-35 Cutting speed in mm/minute 150 50
100
150
200
250
30 0 Input Supply (V
Phase
& Hz) "415V+/-10
3Ph
50/60Hz" - Tank Capacity in Litres 68 - Pressure Kg/cm2 Bar (Must be in between 5-10 bar) 5 - Protection Class IP
Min 23 - The system components provide the electrical energy
ionization capability and process control to produce high quality cuts Yes - The plasma arc cutting system complete with a power supply
an arc starting circuit and a torch Yes - IGBT based plasma Yes - 2/5 cutter having power factor more than 0.9 and high efficiency
light weight and portable to be used In Transformer based cutting machine
the transformer to be a heavy duty
sturdy
Copper- double wounded conventional type. NA for IGBT - The transformer based cutting machine to be supplied with trolley NA for IGBT - Input copper cable for connecting power source to main supply (01 No.) - - Length of Torch Cable (in mm) 50 Warranty (Years) 1 1
2
3
4
5 Dimensional Parameters Dimensions of the machine in (mm x mm x mm) - - Weight of the machine (kg) 45 - Additional Accessories Air hose with accessories -(01 No) to be supplied yes - Work connecting cable with earth clamp-01 No to be supplied yes - Air filter cum regulator 01 no to be supplied Yes - Consumable Spares: a) Electrodes & Tip = 25 set each to be supplied Yes - Consumable Spares: b).Outer Nozzle = 25 Nos. Yes - Machine shall comply with all electrical safety regulations for machine/operators YES - Installation and Demonstartion YES - 1 set of Tool Box for day to day Yes - 3/5 maintenance work for plasma cutting machine and air compressor to be supplied Black Glass Goggles Confirming to 4 DIN specially used for Plasma cutting machine (2 in nos) to be supplied false - Fire Proof Dress to be supplied false Hand Gloves to be supplied false CNC Interface to be supplied false Storage Case for Torch and Cables to be supplied Yes - Operating and Instruction Manuals Yes - On/Off Switch on Torch true - Reports Availability of Type Test Report covering complete test parameters
from any ILAC/NABL accredited/Central Gov LAB Yes - Test certificate No - - Test Report Date - - Name and address of the Lab where test Conducted. - - Copies of certificates to be provided to buyer on demand at the time of supplies Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shantilal T C 673016
Govindrapuram P O Calicut 1 15 4/5
395399
GEM/2018/B/55965
GeM Contract
plasma air cutting machine
GeM Contract
15 days
Kerala; Kozhikode
PRODUCT
Awarded to SOHAM IMPEX
₹2.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| AIR PLSMA CUTTING MACHINE 25MM | SI-APC-25 | - | 1 NOS | ₹2.0 L | 198,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| plasma air cutting machine Plasma Air Cutting Machine ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Performance Parameters Power Sources IGBT Based IGBT Based | - | - | - |
| Transformer Based Type of metal which can be cut All (MS | - | - | - |
| SS | - | - | - |
| Brass | - | - | - |
| Copper | - | - | - |
| Aluminium) Stainless Steel | - | - | - |
| Alumini um | - | - | - |
| All (MS | - | - | - |
| Aluminium) | - | - | - |
| Mild Steel Material Removing rate (Kg/Hr) 25 Current Range (in Amp) 10-100 10-40 | - | - | - |
| 10-55 | - | - | - |
| 10-100 | - | - | - |
| 20- 150 Max open circuit Voltage in (Volt) 280-320 - Current Rating of Power Source at 100% Duty cycle in ampere 100 Current Rating of Power Source at 60% Duty cycle in ampere 60 Current Rating of Cutting Torch at 100% Duty cycle in ampere 100 1/5 Current Rating of Cutting Torch at 60% duty cycle in ampere 60 Efficiency of Machine (%) 85 80 | - | - | - |
| 85 | - | - | - |
| 90 Insulation Class H - Type of Air Compressor Reciprocating Type Reciprocating Type | - | - | - |
| Centrifugal Type Make of Air Compressor - - Type of Gas Supply to Power Source - - Motor Power for Air Compressor (Single Phase ) in HP 5 - Air Flow Rate | - | - | - |
| Maximum (in kg/cm2) - - Type of Cooling Forced Air - Type of Torch Hand Held Based - Maximum Clean Cut Thickness (in mm) 25 6 | - | - | - |
| 12 | - | - | - |
| 25 | - | - | - |
| 50 Output Current Range | - | - | - |
| DC Amp 80-100 35-40 | - | - | - |
| 45-55 | - | - | - |
| 80-100 | - | - | - |
| 12 0-150 Rated input Range kVA (KVA) 15-20 5-7 | - | - | - |
| 7-10 | - | - | - |
| 15-20 | - | - | - |
| 25-35 Cutting speed in mm/minute 150 50 | - | - | - |
| 100 | - | - | - |
| 150 | - | - | - |
| 200 | - | - | - |
| 250 | - | - | - |
| 30 0 Input Supply (V | - | - | - |
| Phase | - | - | - |
| & Hz) "415V+/-10 | - | - | - |
| 3Ph | - | - | - |
| 50/60Hz" - Tank Capacity in Litres 68 - Pressure Kg/cm2 Bar (Must be in between 5-10 bar) 5 - Protection Class IP | - | - | - |
| Min 23 - The system components provide the electrical energy | - | - | - |
| ionization capability and process control to produce high quality cuts Yes - The plasma arc cutting system complete with a power supply | - | - | - |
| an arc starting circuit and a torch Yes - IGBT based plasma Yes - 2/5 cutter having power factor more than 0.9 and high efficiency | - | - | - |
| light weight and portable to be used In Transformer based cutting machine | - | - | - |
| the transformer to be a heavy duty | - | - | - |
| sturdy | - | - | - |
| Copper- double wounded conventional type. NA for IGBT - The transformer based cutting machine to be supplied with trolley NA for IGBT - Input copper cable for connecting power source to main supply (01 No.) - - Length of Torch Cable (in mm) 50 Warranty (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Dimensional Parameters Dimensions of the machine in (mm x mm x mm) - - Weight of the machine (kg) 45 - Additional Accessories Air hose with accessories -(01 No) to be supplied yes - Work connecting cable with earth clamp-01 No to be supplied yes - Air filter cum regulator 01 no to be supplied Yes - Consumable Spares: a) Electrodes & Tip = 25 set each to be supplied Yes - Consumable Spares: b).Outer Nozzle = 25 Nos. Yes - Machine shall comply with all electrical safety regulations for machine/operators YES - Installation and Demonstartion YES - 1 set of Tool Box for day to day Yes - 3/5 maintenance work for plasma cutting machine and air compressor to be supplied Black Glass Goggles Confirming to 4 DIN specially used for Plasma cutting machine (2 in nos) to be supplied false - Fire Proof Dress to be supplied false Hand Gloves to be supplied false CNC Interface to be supplied false Storage Case for Torch and Cables to be supplied Yes - Operating and Instruction Manuals Yes - On/Off Switch on Torch true - Reports Availability of Type Test Report covering complete test parameters | - | - | - |
| from any ILAC/NABL accredited/Central Gov LAB Yes - Test certificate No - - Test Report Date - - Name and address of the Lab where test Conducted. - - Copies of certificates to be provided to buyer on demand at the time of supplies Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shantilal T C 673016 | - | - | - |
| Govindrapuram P O Calicut 1 15 4/5 | - | - | - |
Exempted
3 Aug 2018
27 Jul 2018
contract_GEMC-511687794336712.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_395399.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .