SCHEDULE -B ABSTRACT SHEET
Schedule No. Description of Work Amount Put to Tender
Schedule- B1 Compund Wall
Schedule- B2 Shed For Cows
Schedule- B3 Site Development
Schedule- B4 Plantation
Schedule- B5 Electrification
TOTAL TENDER COST IN (Rs.)
Estimated Amount
Rs………………………. Sub total amount put to the
Rs………………………. Sub total amount put to the
Sub total amount put to the tender
Sub total amount put to the tender
Deduct…………. % below Rs………………………. Add…………. % above
Net Rs………………………. Net
Note-1 All work shall be carried out as per public works department hand book
and other specifications as per tender or as directed by Engineer in
Note-2 Rates quoted include clearance of site (Prior commencement of work and
at its close) in all respects and hold good for work under all conditions,
site, moisture, weather etc.
Signature of Contractor with Stamp SURENDRANAGAR MUNICIPAL CORPORATION
DEVELOPMENT OF GAUSHAL (PANJARAPOLE) AT SURENDRANAGAR
Sr. No. Description Total Qty Unit Rate Amount
Excavation for foundation up to 1.5 M Depth including sorting out and stacking of useful materials and
1 disposing of the excavated stuff up to 50 meter lead 350.00 cum 117.08
(A) Loose or soft soil >0.00 mt. to 1.50 mt. Depth
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone
2 aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation 31.41 cu.m 2956.23
Providing and laying controlled cement concrete M.250 and curing complete including the cost of
3 formwork and including reinforcement for reinforced concrete work in (A) Foundations, footings, Base 20.00 cum 4494.60
of columns and Mass concrete. (upto 10 ton)
Providing and laying controlled cement concrete M.250 and curing complete including the cost of
formwork and excluding the cost of reinforcement for reinforced concrete work in (D) Columns upto
floor two level. (upto 10 ton) including surface dressing and excavation for beams and its PCC.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of
5 formwork and excluding reinforcement for reinforced concrete work in (C) Beams upto floor two level. 67.50 cu.m 6147.45
Providing TMT Bars FE 500D reinforcement for R.C.C work including Bending, Binding and Placing in
position complete up to floor two level.(upto 10 ton)
Filling available excavated earth (excluding rock) in trenches ,plinth, sides of foundations etc.in layers
7 not exceeding 20cm in depth consolidating each deposited layer by ramming & watering. 311.91 cu.m 130.39
Brick Work using Common Burnt Clay Building Bricks having crushing strength not less than 35 kg / Sq.
8 cm. in foundation and plinth. In Cement Mortar 1:6 (1 Cement : 6 Fine Sand) (B) Conventional Extra for 41.41 cu.m 4021.02
brick work in superstructure above plinth level upto floor two level
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of
9 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1- 619.60 Sqm 326.11
cement : 1-sand) etc. complete.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required
10 shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose 619.60 Sqm 114.53
powdered materials.etc complete
Providing and fixing MS grills of required patterns to wooden frames of windows etc. with M.S. flats at
11 equired spacings and frame alround, square or round bars with round headed bolts and nuts or by 5000.00 KG 153.20
screws. (B) ORNAMENTAL GRILL
Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all
lead and lift. (i) R.C.C. work
Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In Cement Mortar
Total Tender Cost in (Rs)
Contractor's Signature With Stamp
DEVELOPMENT OF GAUSHAL (PANJARAPOLE) AT SURENDRANAGAR
Taluka : Surendranagar District : Surendranagar
Sr. No. Description Total Qty Unit Rate Amount
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a
1 priming coat of red lead paint. (A)In beams and joists, channels angles Tees, flats, with connecting plates or angle 83.41 Nos 9047.87
cleats as in main and cross beams. Hip and jack rafters, purlins conneted to common rafters and the like
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a
priming coat of red lead paint. (D) In trussses and trussed purlins, upto 25 M. span and 15 M. ovarall height.
Supplying and fixing side cladding using colour coated Galvanized Iron (GI) sheet of approved make and shade
(RAL-9002), 0.5 mm thick, fixed over structural framing with self-drilling screws with neoprene washers at
required spacing, including overlaps, cutting, wastage, scaffolding, and all necessary accessories to complete the
job in all respects as per manufacturer specifications.The sheet shall have an effective cover width as per profile,
and minimum yield strength of 240 MPa, with zinc coating not less than 120 gsm (Z-120). Work shall be carried
out as per the site conditions and as per the instructions given by the Engineer-in-Charge.
Providing corrugated G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts 8mm
4 diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete excluding 2055.60 Cmt 727.13
the cost of purlins, Rafters and Trusses.(1) 0.80 mm thick sheet.
Providing and fixing of Ridge flashing for roof panel shall be made out of 0.5 mm thick pre coated GI sheet . The
Precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc
coating of minimum 120 gsm as per IS:277:1992 , 5-7 microns epoxy primer on both side of the sheet and
polyester top coat 15-18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns
to avoid scratches during transportation. The ridge shall be fixed to the steel members by pop rivet or self
drilling/self stitching fastners @ maximum 450 mm c/c along length of capping/flashing etc complete .
Providing and fixing factory-made Transparent Polycarbonate Roofing Sheets (Skylight Sheets) of 2.0 mm
thickness in required profile (matching the adjacent roofing sheet profile), of approved make and quality, fixed
with self-drilling screws with EPDM washers, including necessary overlaps, sealing, scaffolding, cutting to
6 required size, and wastage, etc., complete in all respects.The sheet shall be UV-resistant, fire-retardant, and 945.50 Sqm 90.90
impact-resistant with a minimum light transmission of 85%, and shall conform to relevant IS standards or
international equivalent. The work shall be carried out as per site condition and as per the instructions of Engineer-
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint, brushing,
7 interior to give an even shade, including cleaning the surface an even shade including cleanicn the surface of all 3225.20 Cmt 87.81
dirt, dust and other foreign matter.
Total Tender Cost in (Rs)
Contractor's Signature With Stamp
DEVELOPMENT OF GAUSHAL (PANJARAPOLE) AT SURENDRANAGAR
Taluka : Surendranagar District : Surendranagar
Sr. No. Description Total Qty Unit Rate Amount
Providing, planting and developing ground covers with the approved variety of plants including
excavating the existing soil to a maximum depth of about 300 mm, removal of excavated earth to
1 directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture, 5000 Sqm 311.30
planting approved quality grass, including weeding out and removal of foreign matter, watering etc
c/c distance as per carpet effect
Supplying and planting of shade, ornamental, fruit, flowering trees, small, medium and large specimens
suitable for region, adaptable to low water, as per under noted varieties, with ht. as specified in
drawings including excavation of pit of size 0.9 m x 0.9 m x 0.9 m filling the pit with soil mixture etc. as
per specifications and as directed complete in all respect including, Sweet Soil, watering and nurturing
for 6 month. The trees may be planted individually in rows or in cluster as per direction in drg. and all
plant material and its sizes and height/girth and crown should be shown to the landscape architect/
Project Manager & written approval to be sought before planting.
300 mm polybag size; 3000 mm height; c/c distance as per drawing
Total Tender Cost in (Rs)
Contractor's Signature With Stamp
DEVELOPMENT OF GAUSHAL (PANJARAPOLE) AT SURENDRANAGAR
Sr. No. Description Total Qty Unit Rate Amount
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates
mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height
2 and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line 2500.00 Rmt 361.64
and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of
concrete M300 pnumatic compressed / vibrated mechanically and as per approved design Confirming to IS
: 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per
guidlines of IRC : SP 63-2018 etc. Complete.
Total Tender Cost in (Rs)
Contractor's Signature With Stamp
DEVELOPMENT OF GAUSHAL (PANJARAPOLE) AT SURENDRANAGAR
Sr. No. Description Total Qty Unit Rate Amount
Part-3 Internal Electrical
Providing & erecting Weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel
board having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick
CRC M.S. sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling,
welding, riveting with internal partitions & instruction of engineer-in-charge with erection of Supplied switch
gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aliminium strips, rubber
grommets, rib, Bakelite control fuses for measuring instruments, earth bus & earth bolts, sufficient nos. of hinged
doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy
powder coating.
( The rates excludes the cost of switchgears , bus bars, inter connecting mains & Copper Aluminium strips,
meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with
following approved manufacturers with following size.
The standard companies switchgear shall be used and only manufactures at CPRI approved factory and shall be
certified by used after fabrication for beneficial use
With 350 mm depth ,0.8 x 0.8 mtr
DISTRIBUTION BOARD
2 Note :- Enclosure should be used of same company of MCB or MCBDP or ELCB Half / One Module Blanking 18.00 Nos 8.08
Plate of Standerd Size.
Supplying & erecting Sheet Steel powder coated Cable and termination Box to be mounted on Trip or Bottom of
3 the MCB Distribution Box for housing / covering Extra wires & Cables, suitable for following size of MCB DB 31.00 Nos 242.40
Providing and erecting Sheet Steel powder coated MCB distribution board - Flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, confirming to IS:13032 and BS-5486-1986 without MCB to house
appropriate nos. of MCB's (The DBs should be used of same company of MCB to be used)
Three Phase 6 way Single door for single phase outgoing horizontal box.
MOULDED CASE CIRCUIT BREAKERS
Approved make Four Pole moulded case circuit breaker having breaking capacity ICU of 35 K.A. at 415V, having
5 normal current & rating up to 200A., with veriable thermal & magnetic release suitable to work on A.C. supply 1.00 Nos 13635.00
50 cys. With all internal connections & complete erected in 16 G.M.S. Housing on angle frame. ICS= 100% of
ICS only. Cat-II
MINIATURE CIRCUIT BREAKERS.
Miniature circuit breaker Single Pole 6 A to 32 A suitable to operate on 240 V A. C. system and having overload
and short circuit tripping elements and breaking capacity 10 KA to be erected in existing M. S. Box confirming to
IS 8828/1996 with ISI mark. Cat-III
Providing & erecting 230 V. MCB Two Pole switch for Motor & inductive Load ( C Curve) having 10 KA
7 breaking capacity & confirms to IS: 8828 in existing box having following capacity 61.00 Nos 308.05
A) 6 to 32 Amp. Cat-II ( For Incomer of DB of Individual Home & Outgoing of Floor LDB)
Providing & erecting 415 V. MCB Four Pole switch for Motor & inductive Load ( C Curve) having 10 KA
8 breaking capacity & confirms to IS: 8828 in existing box having following capacity 25.00 Nos 616.10
A) 6 to 32 Amp. Cat-II
1. For Point wiring above 10 mtr of length, additional length will be added at rate of mains.
2. For point wiring in bathroom ,W/C and Wash basin area in residential quarters reduce overall rate by 50% of
point wiring for light.
Point wiring in Copper
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in existing pipe duly erected complete with
earth continuity and necessary connection with primary light with accessories erected on polished wooden
9 block/Metal/ PVC box covered with 3 mm thick laminated sheet for open / concealed wiring. 1200.00 Nos 404.00
Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for Secondary Point.
Point wiring in Copper (Modular)
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multistrand copper wires, in existing pipe duly erected complete with 6A
Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic
box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected
(a) with medium class Rigid PVC pipe and accessories Cat-II
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multistrand copper wires, in existing pipe duly erected complete with 6A Modular type
switch and hum free EME four or more step type electronic fan regulator with separately mounted and
accessories with earth continuity of following type erected on PVC / Metallic box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe erected.
(a) with medium class Rigid PVC pipe and accessories Cat-II
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires, in existing pipe duly erected complete with Modular type switch
& 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of accessories.-CAT II
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories Cat-II
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box covered
12 with appropriate front plate modules erected on / in wall / ceiling with following type accssories 240.00 Nss 222.20
B) Single mounting base-frame & Textured / Metallic front plates. Cat-II
Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate
front plate modules erected with necessary connection. As desired by Engineer Incharge
13 (3) Two Pin / RJ-11 Telephone Socket with Top Cat-II 240.00 Nos 131.30
[A] For One Gang
14 (4) TV Co-axial Socket outlet Cat-II 210.00 Nos 141.40
15 (11) Bell Push Cat-II 210.00 Nos 111.10
Conduits & Pipes
Providing and erecting 1.5 mm thick FIA approved and ISI mark ( embossed) RIGID PVC PIPES of following
size complete erected with necessary PVC fittings and Junction boxes fixed with adhesive solution and Clamps
16 with following type of erection. 1500.00 Mtr 32.32
(2) For erection concealed in wall / slab along with continuous fish wire to draw mains, laid in approved manner
with Plastering by cement mortar & finishing the surface to match the wall / ceiling.
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts
17 etc. complete of following sizes. 1200.00 Mtr 25.25
Supplying & erecting PVC trunking (PVC Casing-n-Caping) having double-locking arrangement with grooves,
trunking of size not below 12.5 mm in height as per IS with accessories of PVC/Resin polypropylene not below
1.8 mm thick duly sealed in joint & erected on wall / ceiling of following size .
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of
pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size
(a) with medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm
22 (a) 1 wire 1.5 sq. mm for Earthing ( Qty as per above ) 2100.00 Mtr 30.30
23 Approved Make CFL Non-Retrofit Light 13/15/18 watt erected if required cat ll 90.00 Nos 141.40
Approved Make Energy Meter 230 V,50 c/s, AC Up to 20A erected as directed with three year replacement
24 guarantee 14.00 Nos 1060.50
TELEPHONE WIRING
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation
twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket
suitable for telephone wiring & confirming to C-DOT erected in existing pipe.of following size of conductors &
nos.of pairs. With necessary connections. Conductor Size 0.5 mm
Providing and erecting Sheet Steel powder coated MCB distribution board - Flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, confirming to IS:13032 and BS-5486-1986 without MCB to house
appropriate No.s. of MCB's (The DBs should be used of same company of MCB to be used) Three Phase
way Single door for single phase outgoing horizontal box.
MINIATURE CIRCUIT BREAKERS.
Providing & erecting 415 V. MCB Four Pole switch for Motor & inductive Load ( C Curve) having 10 KA
breaking capacity & confirms to IS: 8828 in existing box having following capacity
A) 6 to 32 Amp. Cat-II
Approved make energy meter 3 phase 4 wire unbalanced load 500 V,10 A to 60 A complete erected as directed
28 with necessary earth wire, 1.00 Nos 3120.90
UNARMOURED COPPER CABLES.
Supplying and erecting XLPE(IS:7098)(I)-88 ISI marked unarmoured Copper cable for 1.1 KV grade to be
29 erected as directed of following size. 301.00 Mtr. 199.98
F) 3 Core 4 Sq.mm.
Total Tender Cost in (Rs)
Contractor's Signature With Stamp
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Document
Document
Document
Document
03.Item Wise Specification (Civil Work).pdf
04.Item Wise Specification (Plantation Work).pdf
05.Item Wise Specification (Electrical Work ).pdf
06.Building-Specification.pdf
07.MORTH Specification Book.pdf
08.Price Bid.pdf
09.Schedule B.pdf
10. Drawings.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .