Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 CrAccepted-Finance | ₹7.4 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹8.9 CrRejected-Finance | ₹8.9 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹10.1 CrRejected-Finance | ₹10.1 Cr | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Alchem Industries L2 | VIJAYAN ENTERPRISES L3 | M A JAMES, Mannasseril L1 |
|---|---|---|---|---|---|---|
| 1.00Supply erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams of Alappuzha, Kottayam and Pathanamthitta district with the specifications listed below: Suitable for handling saline and silty water with rpm 1000 (Syn) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel, impeller, shaft, shaft sleeve, fastener and suction pipe shall be of SS 304. Delivery pipe should be in SS 304 with minimum thickness 6 mm and of suitable length (varies from 4-10 m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starter of reputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal over load protection relay, earth fault relay, voltmeter, ammeter, fault indication start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50mm x 50mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc. | ||||||
| 1.01 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):266
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):15 | 6 | Nos | 56,77,500 ₹56,77,500 | 70,49,970 ₹70,49,970 | 48,90,000 ₹48,90,000 |
| 1.02 | Duty point head (m) : 2
Minimum discharge at Duty point head (lps):532
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):20 | 2 | Nos | 21,29,400 ₹21,29,400 | 25,29,990 ₹25,29,990 | 19,00,000 ₹19,00,000 |
| 1.03 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):354
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):20 | 22 | Nos | 2,09,48,400 ₹2,09,48,400 | 2,69,49,890 ₹2,69,49,890 | 2,02,40,000 ₹2,02,40,000 |
| 1.04 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):443
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):25 | 10 | Nos | 1,02,99,000 ₹1,02,99,000 | 1,34,99,950 ₹1,34,99,950 | 94,50,000 ₹94,50,000 |
| 1.05 | Duty point head (m) :3
Minimum discharge at Duty point head (lps):532
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):30 | 5 | Nos | 54,31,000 ₹54,31,000 | 61,24,975 ₹61,24,975 | 52,45,000 ₹52,45,000 |
| 1.06 | Duty point head (m) :2
Minimum discharge at Duty point head (lps):1064
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):40 | 1 | Nos | 18,84,990 ₹18,84,990 | 18,44,995 ₹18,44,995 | 13,80,000 ₹13,80,000 |
| 1.07 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):709
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):40 | 4 | Nos | 59,93,600 ₹59,93,600 | 69,39,980 ₹69,39,980 | 52,00,000 ₹52,00,000 |
| 1.08 | Duty point head (m) : 2
Minimum discharge at Duty point head (lps):1330
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):50 | 6 | Nos | 1,31,81,280 ₹1,31,81,280 | 1,21,19,970 ₹1,21,19,970 | 87,00,000 ₹87,00,000 |
| 1.09 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):886
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):50 | 9 | Nos | 1,63,76,220 ₹1,63,76,220 | 1,70,99,955 ₹1,70,99,955 | 1,27,35,000 ₹1,27,35,000 |
Tender Value
Refer Docs
EMD Value
₹9.8 L
Closing Date
20 Sept 2025, 3:00 pmClosed
Director of Agriculture
The Director of Agriculture Agriculture Development and Farmers Welfare Department Vikas Bhavan Thiruvananthapuram 695033
Supply, installation, trial run, and commissioning of Vertical Axial Flow Non-Submersible Pump Sets under NABARD RIDF XXX Replacement of Petty Para with Energy-Efficient Pump Sets for dewatering paddy fields in Alappuzha, Kottayam, and Pathanamthit
2025_AGRI_783862_1
ADFW/9457/2023-TG-II(2)/2/NS
Open Tender
Equipments
365 days
Kuttanadu area
Please refer Tender documents.
12 documents required · 12 mandatory
₹2.0 L
₹9.8 L
Yes
30 Jun 2026
20 Aug 2025
22 Sept 2025
20 Aug 2025
20 Sept 2025
27 Aug 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams of Alappuzha, Kottayam and Pathanamthitta district with the specifications listed below: Suitable for handling saline and silty water with rpm 1000 (Syn) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel, impeller, shaft, shaft sleeve, fastener and suction pipe shall be of SS 304. Delivery pipe should be in SS 304 with minimum thickness 6 mm and of suitable length (varies from 4-10 m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starter of reputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal over load protection relay, earth fault relay, voltmeter, ammeter, fault indication start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate. Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards. Screen with 6mm GI welded mesh with 50mm x 50mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level. Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc. | |||||
| 1.01 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):266
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):15 | 6 | Nos | - | - |
| 1.02 | Duty point head (m) : 2
Minimum discharge at Duty point head (lps):532
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):20 | 2 | Nos | - | - |
| 1.03 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):354
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):20 | 22 | Nos | - | - |
| 1.04 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):443
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):25 | 10 | Nos | - | - |
| 1.05 | Duty point head (m) :3
Minimum discharge at Duty point head (lps):532
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):30 | 5 | Nos | - | - |
| 1.06 | Duty point head (m) :2
Minimum discharge at Duty point head (lps):1064
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):40 | 1 | Nos | - | - |
| 1.07 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):709
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):40 | 4 | Nos | - | - |
| 1.08 | Duty point head (m) : 2
Minimum discharge at Duty point head (lps):1330
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):50 | 6 | Nos | - | - |
| 1.09 | Duty point head (m) : 3
Minimum discharge at Duty point head (lps):886
Working head range m:1 to 4.5
Minimum Overall efficiency (%) at duty point head:70
Available connected load (hp):50 | 9 | Nos | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.