Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAdmitted-Finance FIRST DAR COMPLEX MALA BAGH NEAR JK BANK SRINAGAR SRINAGAR JAMMU AND KASHMIR 190006 | SRINAGAR | JAMMU AND KASHMIR | 190006 | L1 | Admitted-Finance | |
| 2 | L2₹14.5 L+₹51,820 (3.71%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HARMUKH INFRASTRUCTURE PRIVATE LIMITED L1 | DREAMSGROUP L2 |
|---|---|---|---|---|---|
| 1.01 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15] | 70 | Nos | 9,44,930 ₹9,44,930 Lowest | 10,08,000 ₹10,08,000 |
| 1.02 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor | 3.3 | KM | 2,31,000 ₹2,31,000 | 1,48,500 ₹1,48,500 Lowest |
| 1.03 | Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) | 70 | Nos | 14,000 ₹14,000 Lowest | 28,000 ₹28,000 |
| 1.04 | Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes. | 90 | Kgs | 10,800 ₹10,800 Lowest | 12,240 ₹12,240 |
| 1.05 | Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr) | 70 | No | 1,26,000 ₹1,26,000 Lowest | 1,61,000 ₹1,61,000 |
| 1.06 | Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm | 70 | No | 34,930 ₹34,930 Lowest | 40,600 ₹40,600 |
| 1.07 | Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT | 210 | No | 4,200 ₹4,200 Lowest | 8,400 ₹8,400 |
| 1.08 | Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm | 210 | No | 31,500 ₹31,500 Lowest | 42,000 ₹42,000 |
| 1.09 | Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification:
1.The Dimension of the Stensil should be not less than 21"x9" per pole.
2.The following details are to be recorded on each pole with the Spray paint.
a). Name of the Work
b)Year
c). Name of the Contractor
d). SR of the pole
The said Stensil should be approved by EDV Ganderbal | 70 | No | 700 ₹700 Lowest | 1,050 ₹1,050 |
| 1.10 | Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book and autocad single line diagram= 10JOB | 1 | Job | 10 ₹10 Lowest | 100 ₹100 |
Tender Value
₹14.8 L
EMD Value
₹29,600
Closing Date
21 Sept 2026, 4:00 pmClosed
Ex Engineer ED Ganderbal
Office of the Ex Engineer ED Ganderbal
Improvement of HT/LT Network of ED Ganderbal
2026_PDD_321288_1
EDG/V/070 OF 2026-27
Open Tender
Electrical Works
Lump-sum
20 days
GANDERBAL
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Ex Engineer ED Ganderbal
₹29,600
22 Sept 2026
18 Aug 2026
22 Sept 2026
18 Aug 2026
21 Sept 2026
18 Aug 2026
18 Aug 2026 - 19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15] | 70 | Nos | - | - |
| 1.02 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor | 3.3 | KM | - | - |
| 1.03 | Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) | 70 | Nos | - | - |
| 1.04 | Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes. | 90 | Kgs | - | - |
| 1.05 | Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr) | 70 | No | - | - |
| 1.06 | Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm | 70 | No | - | - |
| 1.07 | Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT | 210 | No | - | - |
| 1.08 | Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm | 210 | No | - | - |
| 1.09 | Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification:
1.The Dimension of the Stensil should be not less than 21"x9" per pole.
2.The following details are to be recorded on each pole with the Spray paint.
a). Name of the Work
b)Year
c). Name of the Contractor
d). SR of the pole
The said Stensil should be approved by EDV Ganderbal | 70 | No | - | - |
| 1.1 | Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book and autocad single line diagram= 10JOB | 1 | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
SBD070.pdf
Tender Documents • 0.43 MB
TECH001.pdf
Tender Documents • 13.74 MB
BQ_070.xls
Tender Documents • 0.32 MB
BOQ_1072275.xls
BOQ • 0.32 MB
Extension0702.pdf
PDF • 0.24 MB
Extension070.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .