| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹25.3 L+₹29,793 (1.19%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹25.3 L+₹36,238 (1.45%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹25.9 L+₹92,709 (3.72%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹28.7 L+₹3.7 L (14.9%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Feb 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR/MAINTENANCE OF HT OVER HEAD LINE AND POLES OF 33 KV AND 11 KV POWER AND DISTRIBUTION TRANSFORMERS, HT PANELS, EARTHING AND OTHER CONNECTED WORKS AT NAGTALAO UNDER GE BANAR
2023_MES_575980_1
82223/87/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE BANAR
₹60,000
Yes
8 Apr 2023
19 Jan 2023
18 Feb 2023
19 Jan 2023
16 Feb 2023
3 Feb 2023
20 Jan 2023 - 2 Feb 2023
Amount
S&F in repair straight through joint, heat shrinkable type suitable for 11 KV, 3 core, PVC /XLPE cable of cross sectional area 120 Sqmm to 185 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, out door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, out door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, in door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, in door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, in door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV grade, out door termination, heat shrink type, complete with jointing material and accessories suitable for 3 core, XLPE armoured, Aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified and directed
M&L for checking, tightening and replacement of jumpers, clamps connectors of 33 KV, bus bar for the power transformer in the yard/sub station complete all as specified and directed
M&L for resagging of overhead conductor section of 33 KV including binding/re-binding of conductor with suitable size of wire and providing of jumpers at the ends as per site requirements complete all as specified and directed
M&L for replacement of rusted/broken GI earth wire of 4 mm dia for guard on overhead line by providing reels and clamps and any other items required for fixing as per site requirement complete all as specified and directed
Dismantling and taking down HT pole of old ACSR conductor complete all as specified and directed
M&L for Replacement of old ACSR conductor with new ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified and directed
Fixing and restringing of old serviceable (ACSR) conductor obtained from items No 10 here in before including binding complete all as specified and directed.
Taking out old unserviceable 33 KV pin insulator and taking out 33 KV OH ACSR conductor and supply and fix 33 KV pin type, porcelain, vitreous, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for fixing of insulator on HT pole including refixing the OH ACSR conductor at the same place and binding the conductor to insulator with new binding wire complete all as directed.
M&L for replacement of defective/damaged Disc insulators suitable for 33 KV overhead conductors including removing/providing jumpers with line conductors as per required at site complete all as specified and directed.
M&L for straightening of cross arms with clamps including tightening of nut bolts, washers complete all as specified and directed
M&L for Servicing, testing the functioning of all the existing 33 KV panels, Indoor/Outdoor VCBs & all other connected accessories and carrying out necessary maintenance such as applying grease, gel etc., including calibration of VCBs, carrying out necessary repairs along with making arrangements for testing of equipment and necessary instruments required for testing of relays installed over the panels all as specified and as directed by Engr-in-charge. Note: Spare parts shall be measured and paid separately under relevent schedule items.
M&L for Servicing, testing the functioning of all the existing 11 KV panels, VCBs & all other connected accessories and carrying out necessary maintenance such as applying grease, gel etc., including calibration of VCBs, carrying out necessary repairs along with making arrangements for testing of equipment, and necessary instruments required for testing of relays installed over the panels all as specified and as directed by Engr-in-charge Note: Spare parts shall be measured and paid separately under relevent schedule items
S$F Over Current and Earth fault protection relay suitable for 33/11 KV, VCB Panel complete all as specified and directed by Engr-in-Charge
S&F Master Trip relay operating voltage 110V, AC and 24V, DC suitable as per existing make for 33/11 KV, VCB Panel complete all as specified and directed
S&F annunciator panel, 12 window type as per existing make and capacity complete all as specified and directed
S&F in repair Buch, WTI , OTI Trip relay of existing size for 33/11 KV VCB Panel complete all as specified and directed
S&F in repair Digital Volt meter suitable for HT VCB Panel complete all as specified and directed
S&F in repair Digital Ammeter suitable for HT VCB Panel complete all as specified and directed
S&F in repair Auxiliary relay for Buch, WTI, OTI Alarm suitable for HT VCB Panel complete all as specified and directed
Supply, fixing and testing in replacement of 12V, 2Ah battery, 55 Nos for output 110 V, DC ( 55 Nos battery for 2 Ah in series connection installed on iron rack suitable for battery holding in three compartment) maintenance free battery complete connected to existing HT, VCB Panel of 33/11 KV complete all as specified and directed
Taking out old unserviceable stay assembly and S&F stay assembly complete comprising of MS galvanized stay plate 30cm x30cmx6mm, MS galvanized stay rod 20 mm dia with nut 180 cm long, MS galvanized stay bow 40cm long with 2 Nos galvanized thimbles with and including all fittings complete all as specified and as directed. Note:- Excavation, PCC for foundation (PCC 1:3:6), loop type insulator, shackle & clamp shall be measured and paid separately under relevant schedule items
Taking out old stay strand wire and S&F GI stay strand wire of size 7/4mm complete all as specified and directed
Supply and topping of transformer oil with adequate dielectric strength as mentioned in relevant IS as and when required to top up as replacement /evaporation, leakage complete all as specified and directed
Dehydration of Transformer oil (mounted on platform/ poles etc) with the help of filtering and drying plant by mechanical machine of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by EIC. Note : a) The filtration of the transformer oil is to be carried out at different sub station in AGE E/M Nagtalao and also at Main receiving sub Station. (b) The report along with sample of oil before filtration & after filtration to be submitted by contractor for approval by GE (c) The filtration is to be carried out on load i.e. without switching off supply. (d) Transformer oil for topping up will be paid separately under relevant item of Sch 'A'.
Taking out Old unserviceable indicator lamp from 11 KV VCB Panel and S&F new phase indicating lamp, neon type 24DCV/110DCV complete all as per existing make and size with contact block & holder assembly of RYB Colour complete all as directed
M&L cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nut/bolts washers, welding, bending, cold or hot drilling holes for bolts of any shape and size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking out old unserviceable complete all as directed.
Supply, fixing and connecting and testing single pole, zinc oxide (gap less surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 30 KV (rms) discharge current 65 KA insulation level 35/75 KV/KVP (Peak) suitable for rated system voltage of 33 KV supply system with maximum continuous operating voltage (MCOV) not less than17.05 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base insulators and suitable terminals for ground connections and pressure relieving arrangement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arrester on two pole/four pole structure as per recommendations of manufactures.
Dismantling old unserviceable LA and S&F lightening arrestor 11000 volts, non linear resistor type conforming to IS-3070 Part I complete, line discharge class-2 nominal discharge current 10 KA & high discharge 65 KA assembly suitable for 11 KV including all clamps, nuts, bolts & washers & connecting to earth with GI earth wire complete all as specified and directed
Dismantling of existing defective HT 11 KV Gang operated air break switch and Supply and installation, commissioning and testing of HT, 11 KV, outdoor type. triple pole, gang operated air-break switch suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed
Dismantling of existing defective HT 33 KV Gang operated air break switch and Supply and installation, commissioning and testing of HT, 33 KV, outdoor type, triple pole, gang operated air-break switch double stack type suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed
Taking out old silica gel breather and S&F new Silica Gel breather having threaded bore as per site required complete all as specified and as directed.
Taking out old Moisturised silica gel from breather and Supply & filling new silica Gel in the breathers in crystals complete all as specified and as directed.
Taking out old unserviceable PG Clamp and S&F new PG clamp in repair complete all as specified and as directed.
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armourred electric power cable (Heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 sqmm 3 core suitable for 11KV earthed systems complete all as specified and directed.
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armourred electric power cable (Heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 120 sqmm 3 core suitable for 11KV earthed systems complete all as specified and directed.
Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armourred electric power cable (Heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 240 sqmm 3 core suitable for 11KV earthed systems complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth for taking out cable and cable cover etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated materials not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to PVC/ XLPE cables with low grade sand and punning to provide required cover to UG cables complete all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as directed at site by Engineer-in-Charge.
M&L for laying / topping up of 40 mm stone aggregate in switch yard/electric installations/ two pole/ four pole structure and all as directed at site by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm and getting out in any type of soil including cutting, cleaning and removing of bushes/branches/vegetation complete from the site all as directed by Engineer-in- Charge.
Dismantling of existing PCC/Steel Pole and S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-64 (12 meters long) complete all as directed by Engineer-in- Charge.
Dismantling of existing Air termination and S&F Air termination, single pointed aluminium rod of 12 mm dia and 300 mm long complete all as specified and directed by Engr-in-charge
Dismantling of existing GI pipe and S&F GI pipe of 40 mm bore light grade not less than 1.0 mtr to provide height to the air termination rod along with suitable size of stand to fix on the top of pole complete all as specified and directed by Engr-in-charge.
Dismantling of existing aluminium strip and S&F aluminium strip 25X3.15 mm with saddles / porcelain insulator is to be tightened with pole by using suitable size of GI wire for pole and down conductors on the top of pole up to test point complete all as specified and directed by Engr-in-Charge.
Dismantling of existing test point and S&F test point terminal block made of Gun metal or phosphorus bronze size 75X75X25 mm drilled and screwed including 3 nos of 8 mm dia 25 mm long hex head screw complete all as specified and directed by Engr-in-charge.
Dismantling of existing earthing and M&L for plate earthing complete with Copper plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm in alternate layers on all sides and including Copper earth strip 20x3mm bolted (with brass nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to elect pole/main switch board / Neutral of transformer/ body of transformer at the other, earth strip protected by and including GI pipe 40 mm dia (medium grade) from top of electrode to connecting point with equipment and also including watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No 5 of SSR Part I.
Dismantling of existing earthing and M&L for GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts and washers of galvanised iron , earth lead wire protected by means of 15 mm bore dia light grade GI pipe up to switch board / panel board all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:2:4 type C1 in chamber, RCC 1:2:4 type C1 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoal dust, salt, funnel for watering complete as shown on electrical plate No 2 of SSR Part I. all as specified and as directed.
Dismantling of existing copper strip and Supply & laid copper strip in repairs of size 25 mm X 3.15 mm as a ring conductor network buried in ground 1 mtr below from surface complete all as directed at site by Engineer-in -charge
M&L for cutting the branches/trees near the HT OH line up to clearance area 5mtr around OH line by cutting the branches and removing the wastage from site to disposal area and all as specified and directed, Note :- (i) The necessary man power tool and plant, cutting tools and JCB if required for cutting/ punning of branches is deemed to including in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only.
Dismantling of existing GI earthing and M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm in alternate layers on all sides and including GI earth strip of 32x 6 mm as earth electrode bolted with GI nuts, bolts & check nuts and riveted to earth (Plate) electrode at one end and connected to Panel at the other, earth strip protected by and including GI pipe 40 mm dia (medium grade) from top of electrode to Panel and also including watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No 3 of SSR Part I.
Dismantling of existing earth continuity and M&L for earth continuity conductor or main earthing lead fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit/pipe for loop earthing etc. as required 32x6mm galvanized strip complete all as specified and as directed by EIC.
Preventive maintenance /servicing and testing of power transformer 2.0 MVA of 33/11KV at MRSS Ralawas, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength
Preventive maintenance /servicing and testing for power transformer 1.0 MVA of 33/11KV at MRSS Ralawas, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength
Preventive maintenance /servicing and testing of distribution transformer of various capacity up to 500 KVA at Ralawas, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength
Racking out and Servicing for HT switch gear VCB of capacity 400-630, 33 KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the wiring and tripping mechanism, replacement of damaged minor parts such as control wiring ferrules, HRC fuse, calibration of IDMT/Microprocessor numerical/ digital relay existing on panels with secondary injection kit and setting the relay of earth fault, short circuit to over current time delay setting as per existing load of feeder and all as specified and directed by Engr-in-charge at 33 MRS Note: Spare parts shall be measured and paid separately under relevent schedule items
Racking and Servicing for HT switch gear VCB of capacity 400-630, 11 KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the wiring and tripping mechanism, replacement of damaged minor parts such as control wiring ferrules, HRC fuse, calibration of IDMT/Microprocessor numerical/ digital relay existing on panels with secondary injection kit and setting the relay of earth fault, short circuit to over current time delay setting as per existing load of feeder and all as specified and directed by Engr-in-charge at 33 MRS Note: Spare parts shall be measured and paid separately under relevent schedule items
S&F in repair Spring charging Motor, 230V AC/Dc universal type for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Gear assembly Big size for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Gear assembly small size for existing 11 KV VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Trip holding Shaft for existing 11KV VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Trip coil for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Close holding shaft for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Close coil for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Charging Spring for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Drum Switch for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Anti Pumping device 24V, DC for existing VCB complete all as specified and directed by Engr-in-Charge
S&F in repair Limit switch complete all as specified and directed by Engr-in-Charge
S&F in repair Insulating rubber matting ISI mark for 11KV, 2.50mm thickness of matt confirming to IS:15652-2006 complete fixing on floor with suitable pasting material complete as per specification as directed
S&F TNC switch for 11 KV VCB breaker as per existing make and specification and directed
S&F Local remote switch for VCB breaker as per existing make and specification and directed
S&F in repair 11 KV VCB trolley gear having 9 teeth complete all as specified and directed
S&F in repair Service position switch for existing 11 KV VCB complete all as specified and directed
S&F in repair Vacuum interrupter for existing VCB complete all as specified and directed
S&F in repair Local remote switch for existing 11 KV VCB complete all as specified and directed
S&F in repair Dual Core CT Indoor type suitable for 11000 volts for existing VCB complete all as specified and directed
S&F in repair 11 KV PT resin cast ration 11KV /110V 25VA class 0.2 for existing VCB complete all as specified and directed
M&L for preparation of steel surfaces and applying two coats of aluminium paint to Tower poles 12 mts height (14 Nos) including horizontal arms, other structures all clamps, bars, iron items inside the yard of 33 KV MRS complete all as specified and as directed
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent slabs not exceeding 10 mm for 33KV yard/sub station protection for aggregate complete all as specified and directed
S&F PVC insulated multicore FR PVC sheathed multistranded cables with bright annealed electrolytic bare copper conductor 1100V, 2.5 sqmm, 12 core conforming to IS-694:2010 complete all as specified and directed
S&F PVC insulated multicore FR PVC sheathed multistranded cables with bright annealed electrolytic bare copper conductor 1100V, 2.5 sqmm, 4 core conforming to IS-694:2010 complete all as specified and directed
M&L for Cleaning of Power transformer, distribution transformer, VCB outdoor body by cleaning agent, removing the dust by blower, remove corrosion etc after taking proper shut down complete all as specified and directed
M&L for cleaning of power transformer/distribution transformer body by properly scrap, clean and then apply two coats of synthetic enamel paint of existing colour of transformer over a coat of red oxide primer complete using spray gun for shining complete all as specified and directed
M&L for cleaning rust on iron like cross arms, bracing supports clamps, MS sheet from structural steel sections including steel poles and mud clay on RCC pole (2 Pole & 4 Pole also including) and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. Note :- The item included in the painting 3 Nos 30 cm wide bands black & White synthetic enamel paint in alternate layer up to 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of Black colour with HT as per direction of Engr-in-Charge.
S&F in repair 33 KV SRBP tube only for dropout fuses complete all as specified and as directed
S&F in repair 33 KV Fibre glass tube only for dropout fuses as specified and directed
S&F in repair 33 KV Fibre tube with metal fitting on both ends only for dropout fuses as specified and directed
S&F in repair 11 KV SRBP tube only for dropout fuses as specified and directed
S&F in repair 11 KV Fibre glass tube only for dropout fuses as specified and directed
S&F in repair 11 KV Fibre tube with metal fitting on both ends only for dropout fuses as specified and directed
S&F in repair 33 KV Male contact/moving contact blade as specified and directed
S&F in repair 33 KV Female contact/fix contact jaw as specified and directed
S&F in repair 33 KV Tinned copper flexible jumper 200A/400A as specified and directed
S&F in repair 33 KV MS Jumper carrier as specified and directed
S&F in repair 11 KV Male contact/moving contact blade as specified and directed
S&F in repair 11 KV Female contact/fix contact jaw as specified and directed
S&F in repair 11 KV, Tinned copper flexible jumper 200A/400A as specified and directed
S&F in repair 11 KV, MS Jumper carrier as specified and directed
S&F in repair 12KV/250 Amp H.V brass set stem complete set as per IS-3347/1967 as specified and directed
S&F in repair 1.1 KV/250 Amp L.V brass bushing set stem complete set as per IS-3347/1967 as specified and directed
S&F in repair 1.1 KV/400 Amp L.V brass bushing set stem complete set as per IS-3347/1967 as specified and directed
S&F in repair 1.1 KV/630 Amp L.V brass bushing set stem complete set as per IS-3347/1967 as specified and directed
Dismantling of chain link fencing wire mesh any type any size complete all as specified and as directed
S&F MS angle iron as in fencing posts and struts in fencing including cutting tops to shape, drilling holes, cut to length, bent to shape, notching for wire etc conforming to Fe-310 complete all as specified and as directed.
S&F MS work as in FI fillets for securing chain link fencing angle iron horns, posts etc., cut to length bent to shape with necessary cuts, drilling holes, etc., confirming to Fe 310-O complete all as specified and directed
S&F Chain link fencing with mild steel GI wire 3mm dia, , 225 x 150mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and as directed
S&F Mild steel round bar, 10mm dia confirming to Fe-290 gde E-165 as line wire for chain link fencing type including cutting to length, bend to shape required as per site, welding, binding with MS wire complete all as specified and as directed
S&F Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exceeding 5cm but not exceeding 10cm long and dia of shank 11 to 15mm complete all as specified and as directed
M&L for cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in sub base, foundation/flooring etc., complete all as specified and directed
M&L for stone masonry, squared rubble walling in jodhpur type brought up to course well bonded bedded and solidly hearted built in cement mortar 1:4 complete all as per specified and as directed
M&L for rendering 10mm thick cement plaster 1:4 on stone wall/surface complete all as specified and as directed
M&L for preparation of newly plastered wall surface and applying two coats of white wash complete all as specified as directed
M&L for PCC 1:2:4, type B2 using 20 mm graded stone aggregate as in platform, sub base for foundation etc. with quick setting cement complete all as specified and directed
S&F in replacement of 3 Pole 12 Amp contractor confirming to IEC-60947-4-1 complete all as specified as directed
S&F in replacement of 3 Pole 12 Amp overload protection relay confirming to IEC-60947-4-1 complete all as specified as directed
S&F in replacement of Electronic timer 03-30 sec, 415V 50Hz with mounting kit suitable for as per site requirement complete all as specified as directed
S&F in repair expulsion fuse (drop out fuse) mounted on 2 Nos of HT insulators, single pole, up to 50 Amps, 11 KV with spring mechanism complete in all respects and connection as directed.
S&F in repair loop insulator, vitreous porcelain white, brown, green large size of overall dimension 90mmx140mm clearance of hole 25.5mm complete all as per specification and as directed
Supply, fixing and testing maximum demand controller input voltage 50-520VAC, 240 vots for 33 CT ratio 1/5A tripping 1 sec aux supply 80-300 VAC/DC complete with wiring all as per specification and directed
M/s Bajrang Electricals
Anil Builders
LOKESH ELECTRICAL WORKS CONTRACTOR
M/S SHREE AAINATH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .