Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | ₹13.7 L Quoted ₹13.9 L | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹18.1 L+₹4.2 L (30.1%)Rejected-AOC | ₹18.1 L+₹4.2 L (30.1%) | L2 | Rejected-AOC L2 Rejected |
Tender Value
Refer Docs
EMD Value
₹34,274
Closing Date
20 Sept 2023, 11:00 amClosed
MANAGING DIRECTOR
KSDP LTD, KALAVOOR P.O ALAPPUZHA
Additional Electrical Works For LVP/SVP/Ophthalmic production plant of KSDPL.
2023_ksdp_593925_2
KSDP/PRJ/ELE/AEW/16/23-24/88
Open Tender
Electrical Works
Item Rate
45 days
KSDP LTD, KALAVOOR P.O ALAPPUZHA
As per Tender Details
9 documents required · 9 mandatory
₹2,950
₹34,274
23 Nov 2023
2 Sept 2023
21 Sept 2023
2 Sept 2023
20 Sept 2023
2 Sept 2023
2 Sept 2023 - 20 Sept 2023
Additional Electrical Works For LVP/SVP/Ophthalmic production plant of KSDPL.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N
SS 304 enclosure for placing 200 A Switch fuse unit with handle,including 200 A fuse units for three phases
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing cable tray of 3.5 core 120 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm
SS 304 enclosure for placing 160A Switch fuse unit with handle TP&N SFU unit with HRC fuse of 160 A.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.<br>3 X 70 sq. mm (35mm)
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.120 sq. mm
Supplying of PVC insulated PVC sheathed flexible copper power cable of 1.1 KV grade of the following sizes. Single core 70 sqmm
Supplying of PVC insulated PVC sheathed flexible copper power cable of 1.1 KV grade of the following sizes. Single core 120 sqmm.
SS support rods of length 10 to 15 cm mountable on floor for SS cable tray
Supplying and erecting SS 304 cable tray with top cover,fully covered type and laying existing cables in it. 100mm width x 50 mm depth x1.6 mm thickness
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required200 Amp, 25 KA,TPMCCB
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing cable tray of 4 core 10 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
Testing, inspections and obtaining approval from all statutory bodies including electrical inspectorate, kerala state electricity board, and any other statutory bodies if required.And preparation of detailed electrical drawing and submission before electrical inspectorate and getting approval ( statutory fee paid will be reimbursed by KSDP)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing cable tray pipe as required.4 core 6 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4 + 24), Double door
Supply, installation, testing and commissioning of LT cubicle type PCGI Panel of thickness 2mm with Aluminium busbar of proper grading to accommodate 200 A incomer MCCB and 8 outgoings as MCCB rated below with all protective relays and indicators and. [Electrolytic grade Aluminium, suitable for three-phase, 4-core wire, insulated with heat-shrinkable PVC colour code sleeves. ] 1 No 200A 4P 25 kA MCCB as incomer.Outgoing- 1 No 100A 3P 16-25kA MCCB,2 No 63A 3P 16-25kA MCCB,5 No 32A 3P16-25kA MCCB .Connecting incoming and outgoing cables.Rotary handle, spreaders,3mm thick gland plate, hinged type door with neoprene gasket/PU etc.TPN bus bars of high conductivity electrolytic quality aluminium alloy and suitable size earthing conductor throughout the panel for its earthing. Include any additional items if necessary as per the electrical inspectorate standards.
GERESH ELECTRICALS PVT. LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .