Superintending Engineer, P.H. Division, Saheed Nagar , Bhubaneswar-751007, Odisha, Phone (0674) 2540578
11KV line using 55 SQ.MM, XLPE AAA Covered conductor with 10mtr. PSC pole-0.3km, 100KVA DP Mounted DT using 11mtr. WPB Pole-1 no, LT Line using 4Cx150 Sqm Armoured Aluminium cable-XLPE insulated-0.07Km at PHD Colony, Ranapur, Gopalpur, Nayagarh
2026_PHEO_126373_1
SEPHBBSR-85/2025-26 DTD.20.02.2026
National Competitive Bid
Civil Works - Water Works
Percentage
30 days
Ranapur
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,000
₹23,250
Yes
7 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
24 Feb 2026 - 26 Feb 2026
11kV Line Length with 50 Mtr. Span using 55 SQ.MM. XLPE Insulated AAA Conductor
Materials for 11KV Cut point with 180 degree Angle
Straight Cross Arm 100X50X6mm, 9 56 KG/Mir., each Channel(G/) length 1-2 mtr., 2 no's Channe/(Gll reauired =(2x9.56x1.2)
Fish Plate(GI) 50x6 mm., 2.36 k9/Mtr.. each 0.280 mtr. ten;Hh, 8 no·s required= (8x2.36x0.280)
Straight Cross Arm 1OOX50X6mm, 9.56 KG/Mir., each Channel(GI) length O 306 mtr,, 2 no's Channel/Gil reauired =(2x9.56x0.306)
11 KV pin insulator Polymer
H W fittino/B&S) 70KN, 3Bolt
Disc insulator (B&Sl 70 KN polymer
NON METALLIC T/ES-11KV 55SQMM CVRD AMC
IPC for 55 sq.mm AAA conductor (For covered conductor)-11kV
GI Nut , Bolt & Washer of different sizes 13.55 Ka each Cut Pole)
Materials for 11KV Pin points with WPB
PSC POLE 10 METER LONG 330 KG.
PSC Pole Clamp(GI)
11 KV V cross Arm(Gl) (10.2 K.g.. Each)
Top bracket 100x50X6 mm GI Channel(GI) (2kg each)
Danger Plate, 1 no's. for each pole
Back Clamp for danger Plate 25X3 mm. F/at(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg, Per support
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
11 KV pin insulator polymer, 3 Nos. required for each support
Earthing to support( Coil Type)
No-8 GI wire (Dia 4:6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
GI Nut . Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
55 SQ.MM. AAAC XLPE Covered Conductor
Black Paint(GIS Numbering & Zebra Stripping)
Yellow Colour Paint(GIS Numbering & Zebra Stripping for Background
NON METALLIC TIES -11KV 55SQMM CVRD AAAC
Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in each Pole )
Civil & Services
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole)
100 KVA DP Mounted DSS No. of DP Mounted DSS (Ref. Drawing No.- TPCODUTCE/DTR/0001)
SUPPLY OF MATERIALS AND EQUIPMENTS
WPB (GI) Pole 160x152 (11Mtr. Long. 30.44KG/Mtr )-DP
9 Mir. Iona 300 Ka. PSC Pole
Pole clamp for EYE hook for {XLPE Aerial bunched Cable)
EYE hook for XLPE Aerial bunched Cable
Dead End Clamp suitable for messenaer XLPE Aerial bunched Cable
LT Cable raising Channel(GI) 75x40x4.8 mm GI Channel(GI) (1000 mm long)(7.14Kg /Mir., 3 No's) (Each 3x1.000x7.14= 21.42 Kal
Top Channel(GI) GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Ka)
Fish Plate(GI) 50x6 mm., 2.36 ka/Mtr.. each 0.280 mtr. lenath. 6 no's reauired = (6x2.36x0.280)
AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7,14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Ka)
AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 2 no's Channel{Gll reauired =/ 9.56x2x0.35l
Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr, each Channel(GI) length 0.8 Mtr., 1 no's Channel/GI\ reauired =( 7 14x0.8x1)
HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (3000 mm long)(7.14Kg./Mtr.. 2 No's.) /Each 2x3.000x7.14= 42.84 Kg)
Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) /Each 2x0.810x7.14= 11.57 Ka)
Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4 5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)
Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9,56Kg /Mir, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)
Transformer Base Support GI Channel(GI) 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)
Transformer Belting Angle(GI) 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kal
Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Ka)
LTDB Mounting Angle(GI) 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)
50x6mm Flat(GI) for earthing, _2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mir. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr for DTR Nutral. (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81Ka)
100 KVA. 11/ 0.4 KV (AL) Transformer BIS Eneray level II
LT Distribution Box with MCCB, Aluminium Busbar of 2 Bav with kit kat fuse for 100 KVA S/S
55mm2 ACSR - PVC Insulated (50 Mir Each Dtr.)
4 Cx 150 mm2 LT XLPE Cable/Armoured) - FOR 100 KVA Trf.
1.1kV, 4Core. 150 samm. XLPE insulation armoured-Aluminium UG cable from LTDB to Pole
AB Switch(11KV,200A.3pale 50Hz)
H.G.Fuse( 11KV.200A.3Polel
WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
POLYCARBONATE BIRD GUARD
Disc insulator (B&Sl70 KN polymer
H W fittina (B&S)70KN(3bolted)
Liahtnina Arrester(12KV.1OKA) Station Class 2
11KV pin insulator polymer
HT stay set comolete
HT stay Clamp (1.9Ka/pair)
HT stay insulator TYPE-C
7/1o SWG GI stay wire, Grade -2 (15Ka./ Set)
40 mm Nominal bore GI oiPe (medium aauae) earthina device with 3 mtr .Lona
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
GI Barbed wire/Anticlimbina device (3Ka /Pole)
Back Clamp for anticlimbing device 25X3 mm. Flat(GI). 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510l
Dancer elate 11kv
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510l
Name Plate
Structure Numbering and Marking
Yellow Colour Paint(GIS Numberina & Zebra StrioPinal for Backaround
Black Colour Paint{GIS Numbering & Zebra Stripping) for numberina
Civil and Services Works for 100 KVA DP Mounted DSS
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) (For WPBPole)
Coupina ratio 1:1.5:3(M-20 Gradel (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
PCC ratio 1:3:6(M-10 Gradel For DSS Area (5X3XO 1)= 1-5 Cu. mtr.
Fixing of stay set with a.scum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pioe .
Laving of 4 Cx 150 mm2 LT XLPE Cable
SITC and Erection of GI FencinQ with Gate
Suoolv and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) (For PSC Pole)
Supply of AL Lugs suitable for 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting include suoolv and erection of PVC Taoe as oer voltaQe eauirement.
Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 120- 185sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly Supply to be done as per TPCODL Spec and approved make dowells.
LT AB Cable Line Length with 33 Mtr. Span using - 4C X 150sq. mm. Armoured Aluminium Cable - XLPE Insulated
AB Cable LT Line Length In KM with 33 Mtr. Span (Ref. Drawing No.- TPCODL- )
Dead End·upto 70 sq. mm (91 KM)
Suspensfon upto 70 sq. mm (211 KM)
9 Mtr. long 300 Kg. PSC Pole
LT Slav set Comotete
7/12 SWG GI stay wire, Grade -2
LT stav Clamp / 1AOKoloair)
LT Stay insulator
LT Accessories with Eye hook and Clarno
Pole clamo for EYE hook for (XLPE Aerial bunched Cable)
EYE hook for XLPE Aerial bunched Cable
Dead End Ctamo suitable for messenaer XLPE Aerial bunched Cable
Suspension Clamp with EYE hook for ABC
4C X 1SOso. mm. Armoured Aluminium Cable - XLPE Insulated
4 WAY SERVICE Dlstb. Box with kit kat fuse and Aluminium bus bar.
Insulated oiercina connector.Tvoe-B-main 25 to 150 so.mm & Tao-6 to 35 so.mm
Coil Earthina
No-8 Gt wire (Dia 4.6mm) 0.131 KG/ Mir.- 2 Mir. For connectino oole with Coil earthino
Dancer otate <Ln
Back Clamp for danger Plate 25X3 mm. Flat(Gt), 0.59Kg/Mtr. Flat(Gt) of 0.51omtr length 1 no's = 1<1xD.59xD.51Dl
Gt barbed wire anticlimbina device 3 Ka. Per suooort
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.51Omtr length 4 no's= (4x0.59x0.51Dl
Gt Nut , Bolt & Washer of different sizes (0.5 Ko/ Pole)
Black Paint<GIS Numbering & Zebra Striooinal
Yellow Colour Paint(GIS Numberina & Zebra Striooinal for Backaround
Civil & Services
Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire S)Stay clamps with Nuts & bolts, including excvation, supply of a.scum cement concrete foundation 1:2:4 size (5DOmmx500mmx800mm) using 20mm BHG metal with all labour and material <Excavation of earth will be done of size 5DDX5DDX1500 mm.)
Concretin11 ratio 1:1.5:3(M-20 Grade) (50DmmXSOOmmX1500mm) = 0.375Cu.mtr(Per Pote)
11KV Line Length with 40 mtr Span using 55 SQ.MM. XLPE Insulated AAA Conductor
No. of cut point with 180 Degree Angle
Materials for 11KV cut point with 180 Degree angle
PSC POLE 10 METER LONG 330 KG.
PSC Pole Clamp(GI)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 2 no's Channel(GI) required =( 2x9.56x1.2)
Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr., 2 no's Channel(GI) required =( 2x9.56x0.306)
Danger Plate, 1 no's.
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg, Per support
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's=(4x0.59x0.510)
11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
Earthing of Support ( Coil Type )
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr, For connecting pole with Coil earthing
NON METALLIC TIES -11KV 55SQMM CVRD AAAC
IPC for 55 sq.mm AAA conductor (For covered conductor)-11 kV
Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in each Pole )
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)
Black Paint(GIS Numbering & Zebra Stripping)
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Civil & Services
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole)
No. of cut point with 90 Degree Angle
Materials for 11KV cut point with 90 Degree angle
PSC POLE 10 METER LONG 330 KG.
PSC Pole Clamp(GI)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 1.2 mtr., 2 no's Channel(GI) required =( 2x9.56x1.2)
Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 0.306 mtr., 2 no's Channel(GI) required =( 2x9.56x0.306)
Danger Plate, 1 no's.
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg, Per support
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's=(4x0.59x0.510)
11 KV pin insulator polymer
H W fitting(B&S) 70KN, 3Bolt
Disc insulator (B&S) 70 KN polymer
Earthing of Support ( Coil Type )
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr, For connecting pole with Coil earthing
NON METALLIC TIES -11KV 55SQMM CVRD AAAC
IPC for 55 sq.mm AAA conductor (For covered conductor)-11 kV
Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in each Pole )
H.T. Stay clamp, 50x8 mm. flat 3.14Kg/Mtr, 0.551 Mtr Length 2nos qty required ( 1pair)
H.T. Stay set (Complete )
H.T. Stay Insulator Type-C
7/10 SWG Stay Wire 15kg /stay
GI Nut . Bolt & Washer of different sizes (7.433kg each cut pole)
Black Paint(GIS Numbering & Zebra Stripping)
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Civil & Services
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole)
11 Kv Line Length in KM with 40Mtr. Span
Materials for 11KV pin points with WPB
PSC POLE 10 METER LONG 330 KG.
PSC Pole Clamp(GI)
11 KV V cross Arm(GI) (10 2 K.g. each )
Top bracket 100x50X6 mm GI Channel(GI) (2kg each)
Danger Plate, 1 no's. for each pole
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtF length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg. Per support
Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0,510mtr length 4 no's = (4x0.59x0.510)
11 KV pin insulator polymer, 3 Nos. required for each support
Earthing of Support ( Coil Type )
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
55 SQ.MM. AAAC XLPE Covered Conductor
Black Paint(GIS Numbering & Zebra Stripping) .
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
NON METALLIC TIES -11KV SSSQMM CVRD AAAC
Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in each Pole )
Civil & Services
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1667mm) = 0.42Cu.mtr(Per Pole)
25KVA WPB Pole Mounted DT
No. Of DP Mounted DSS (Ref. Drawing No. TPCODL/TCE/DTR/0001)
Materials for DP Mounted DSS Supply of Following Equipment & Materials (As per Technical Specification)
WPB(GI) pole 160X152 (11mtr long.30.44KG/Mtr.)-DP
Top channel(GI) GI 100 x 50 x 6mm (3000 mm long) (9.56 kg/mtr , 2 Nos) (Each 2 x 3.000 x9.56 = 57.36 kg)
Fish Plate 50 x 6 mm, 2.36 kg/mtr, each 0.280 mtr length, 6 nos required ( 6x 2.36x 0.280)
AB Switch Mounting Channel 75 x 40 x 4.8 mm (3000mm long) (7.14 kg /mtr, 2 Nos) (Each 2 x 3.000 x 7.14 = 42.84 kg)
AB Switch side support channel 100 x 50 x 6mm , 9.56 kg /mtr each channel length 0.35 mtr, 2 nos channel required =(9.56 x 2 x 0.35 )
Channel(GI) support for down pipe 75 x 40 x 4.8 mm ,7.14 kg/mtr each channel length 0.8 mtr 1 nos channel required =(7.14 x 0.8 x 1)
HG / DO Fuse mounting channel(GI) 75 x 40 x 4.8 mm GI Channel(3000 mm long (7.14 Kg/mtr , 2 Nos) (Each 2 x 3.000 x 7.14= 42.84 kg)
Cantilever support channel(GI) 75 x 40 x 4.8 mm GI channel (810 mm long , 2 nos) (7.14 kg /mtr, 2 Nos) (Each 2 x 0.810 x 7.14=11.57kg)
Cantilever support angle(GI) 50 x 50 x 6 mm GI (1282 mm long) (4.5 kg /mtr, 2 Nos)(Each 2 x1.282 x 4.5 = 11.54kg)
Transformer Base GI Channel(GI) 100 x 50 x 6mm (3000 mm long) (9.56 kg/mtr, 2 Nos) (Each 2 x 3.00 x 9.56 = 57.36kg)
Transformer Base support GI Channel(GI) 100 x 50 x 6mm (515 mm long) (9.56 kg/mtr, 2 Nos) (Each 2 x 0.515 x 9.56 = 9.85kg)
Transformer Belting Angle(GI) 50 x 50 x 6 mm GI (3000 mm long) (4.5 kg/mtr, 2 Nos) (Each 2 x 3 x 4.5kg)
Transformer Belting Support Angle(GI) 50 x 50 x 6 mm GI (580 mm long )(4.5 kg/mtr, 2 Nos) (Each 2 x 0.580 x 4.5 = kg)
LTDB Mounting Angle(GI) 50 x 50 x 6 mm GI (1000 mm long) (4.5 kg/mtr, 2 Nos) (Each 2x1x4.5kg)
50 x 6mm Flat(GI) for earthing, 2.36 kg/mtr., (2.5 x 7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 Mtr, for raising, 11 Mtr for AB switch, 2.8 mtr. For HG Fuse, 5 x 2Mtr. For DTR Neutral, (1.3 + 4.5) Mtr. For DTR body, 0.500 mtr. For LTDB & AB Switch operating handle, 3 mtr. for fencing ( Each 65.6 x 2.36 = 154.81 Kg)
25 KVA, 11 / 0.4 KV (AL) Transformer BIS Energy level II
LT Distribution Box with MCCB, Alluminium Busbar of single bay with kit kat fuse for 25 KVA S/S
55mm2 ACSR-PVC Insulated (50mtr Each Dtr.)
4 C x 35 mm2 LT XLPE Cable (Armoured) - For 25KVA Trf.
AB Switch (11 KV, 200 A 3 Pole, 50 Hz)
HG Fuse (11 KV, 200 A 3 Pole)
WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
POLYCARBONATE BIRD GUARD
Disc Insulator (B&S) 70 KN Polymer
H W Fitting (B&S) 70 KN (3 Bolted)
Lighting Arrester (12KV,10KA) Station Class 2
11KV Pin Insulator Polymer
HT Stay Set Complete
HT Stay Clamp (1.9Kg/Pair)
HT Stay Insulator TYPE-C
7/10 SWG GI Stay Wire, Grade-2 (15Kg./Set)
40 mm Nominal Bore GI Pipe (Medium Guage) earthing device with 3 Mtr. Long
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
GI Barbed Wire / Anti-Climbing device (3kg/Pole)
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)
Danger Plate 11KV
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)
Name Plate
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering
Civil & Services Works
Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450cu.mtr(per pole)(For WPB pole)
Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole)
PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)= 1.5 Cu. mtr.
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set . stay wire . stay insulator .
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI) around pipe .
Laying of 4 Cx 35 mm2 LT XLPE Cable
SITC and Erection of GI Fencing with Gate
Supply of AL Lugs suitable for 35 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 16-35sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
LT AB Cable line length with 33 mtr span using - 4c X 35 mm² (P) + 1C X 35mm²(M) + 1C X 18mm²(STREET LIGHT)
AB cable LT line length in KM with 33 mtr span
Dead end upto 70 sq mm(9/KM)
Suspension upto 70 sq mm(21/KM)
MATERIALS FOR LT AB CABLE LINE
9 Mtr long 300 kg PSC pole
LT stay set complete
7/12 SWG GI stay wire, Grade - 2
LT stay clamp (1.40 kg/pair)
LT stay insulator
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)
EYE hook for XLPE Aerial bunched Cable
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable
4Cx35 mm2 (P)+1Cx35 mm’(M)+1CX16 mm2(Street Light) (LT AB Cable)
CoiI Earthing
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting poÏe with Coil earthing
Danger plate (LT)
Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. FIat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
GI barbed wire anticlimbing device 3 Kg. Per support
Back clamp for anticlimbing device 25X3 mm. FIat(GI), 0.59Kg/Mtr. FIat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510)
GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)
Black Paint(GlS Numbering & Zebra Stripping)
Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
Civil & Services
Fixing of LT complete stay set includes 1) Turn buckle assembly 2) Stay rod & stay plate 3) Stay insulator 4) Stay wire 5) Stay clamps with nuts & bolts, including excavation, supply of 0.5 Cum cement concrete foundation 1:2:4 size (500mm X 500mm X 800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500 X 500 1500 mm)
Concreting ratio 1:1.5:3(M-20 Grade) (500 X 500 1500 mm) - 0.375 Cu.mtr (per pole)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 1.28 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.33 MB
DTCN.pdf
Tender Documents • 0.61 MB
BOQ_582186.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .