| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹92.6 LAccepted-AOC | ₹92.6 L | L-1 | Accepted-AOC Lowest Bid |
| 2 | L-2₹94.8 L+₹2.3 L (2.47%)Rejected-Finance | ₹94.8 L+₹2.3 L (2.47%) | L-2 | Rejected-Finance Not a lowest bid |
| 3 | L-3₹97.6 L+₹5.0 L (5.40%)Rejected-Finance | ₹97.6 L+₹5.0 L (5.40%) | L-3 | Rejected-Finance Not a lowest bid |
| 4 | L-4₹99.1 L+₹6.5 L (7.01%)Rejected-Finance 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹99.1 L+₹6.5 L (7.01%) | L-4 | Rejected-Finance Not a lowest bid |
| 5 | L-5₹99.5 L+₹6.9 L (7.45%)Rejected-Finance 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹99.5 L+₹6.9 L (7.45%) | L-5 | Rejected-Finance Not a lowest bid |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
30 Jun 2020, 6:00 pmClosed
AGM EE
E and M Workshop complex, Dumas Road, Civil Aerodrome, Surat- 394550
Holistic Development of Surat Airport Including Extension of Apron and Terminal Building and construction of Parallel Taxi Track. SH Apron flood lights and associated works
2020_AAI_41740_1
AAI/SRT/Engg (E)/ Apron ext/AFL/2019-20
Open Tender
Electrical Works
Item Rate
300 days
Surat Airport
As per NIT
16 documents required · 16 mandatory
₹1,180
AIRPORTS AUTHORITY OF INDIA
₹2.6 L
Yes
3 Nov 2020
1 Jun 2020
15 Jul 2020
1 Jun 2020
30 Jun 2020
1 Jun 2020
1 Jun 2020 - 22 Jun 2020
Amount
High Mast
Design, supply, Installation, Erection, Testing and commissioning of 30 m flood light high mast fabricated in three telescopic sections(MS), hot Dip galvanised finish totally on externally and internally etc (with base plate welded to the bottom sections ) and suitable for wind velocity as per IS 875 part 3 (latest) and holdings suitable for installation of flood lighting luminaries including erection of mast & other assemblies as required with following accessories etc as per the tender specifications.
Lantern carriage fabricated and galvanized suitable to hold 6 Nos.or more as per illumination design 350& 500 watt LED flood light fittings and 2 Nos. LED type Single dome aviation obstruction lights(i/c supply of 2nos LED Type single dome aviation light) and to accommodate control gear boxes(as required), Supply and fixing of 20/21 way terminal block suitable for interconnection of flood light fixtures (Qty. 2 Nos.for each high mast) and have self balance including junction box, Heavy guage hot dip galvanized lightening arrester finial.
Electrically operated raising and lowering mechanism consisting of suitable double drum winch assembly, head frame assembly on top with self lubricating bearing, Stainless steel shaft, noncorrosive pulley and stainless steel wire ropes(2 nos one for each drum) of minimum 6mm dia (7/19) etc. and designed to operate with electric driven power tool and also suitable for manual operation including connector, integral power tool motor, manual handle, trailing cable,junction box etc.
Providing & laying required length & appropriate rating of 1.1 KV grade 2 runs of 5 core x 2.5 sq mm copper conductor trailing (EPR insulated PCP sheathed cable for power supply from the top carraige of mast to bottom distribution box / feeder pillar/coupler/connector i/c wiring to the individual fittings & also providing G.I. flexible pipe for protection if required at site.
Supply of foundation bolts manufactured from special steel along with nuts, washer, suitable size anchor plates and template etc as required.
Design & construction of suitable shallow foundation (RCC) with 1:2:4 M20 grade concrete for the highmast considering the safe soil bearing capacity at site at 2 metre depth with all materials and labour. Concrete foundation required for the mast shall be designed based on the soil bearing capacity of site as per relevant IS standards and shall got vetted from the IIT/SVNIT or other reputed institutions to validate the foundation design
Erection of the high mast with the help of suitable equipments and wiring of luminaires with all wiring materials and labour i/c testing & commissioning etc. Complete as required as per site requirement.
Supply & installation of following LED fixture complete with LED, driver & all accessories pre wired upto terminal block operating on 100 -277 volts & 50 Hz with CRI>70% & IP66 protection & IK08 capable to operate from -10o C to 45o C ambient temp. Driver shall be with THD less than 10% and power factor shall not be less than 0.95 & other specifications as per tender.
350W (Maximum system wattage) flood light fixture with beam angle 33O + 10% and made of pressure die cast with fin aluminum alloy duly powder coated housing with clear toughend glass and cradle for mounting giving minimum system output of 35000+ 10% Lumens and 5700K+ 300 CCT
500W (Maximum system wattage) flood light fixture with beam angle of 22O + 10% and made of pressure die cast with fin aluminum alloy duly powder coated housing with clear toughend glass and cradle for mounting giving minimum system output of 60000+ 10% Lumens and 5700K+ 300 CCT
Supply of following Size. XLPE insulated, PVC sheathed Al. conductor armoured power cable of 1.1 KV grade conforming to IS:7098 Part-I with upto date amendment etc. complete as required.
4 core x 35 Sq. mm
3.5 core x 300 Sq. mm
Supply of following size XLPE insulated PVC inner sheathed copper stranded conductor armoured LT control cable of 650/1100 v grade conforming to IS:7098 Part-I(1988) with up to date amendment etc. complete as required.
19 core x 1.5 Sq. mm
10 core x 1.5 Sq. mm
Supply and Laying of 120 mm dia (OD-120 mm & ID-103 mm nominal) sizes DWC HDPE pipe ISI marked conforming to IS 16205 PART 24 (formerly known as IS 14930 Part II) along with all accessories like socket, bend, couplers etc complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation & refilling the trench with same excavated earth.
Supply and Laying of 120 mm dia (OD-120 mm & ID-103 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 16205 PART 24 (formerly known as IS 14930 Part II) complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
Supplying and making end termination with brass compression gland and Aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
3.5x300Sq.mm
4 x 35 Sq.mm
10 /19 core 1.5 Sq.mm (copper)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/PVC pipe as required
Upto 35 sq. mm
above 95 sq. mm upto 185 sq mm
Supplying and installation of cubicle type totally enclosed free standing, dust & vermin proof and water proof (IP-55) outdoor double door type feeder pillar(openable on front & back) of suitable size suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system fabricated out of 2mm thick CRCA sheet duly powder coated of approved shade,3mm thick detachable gland plates at bottom with 2 Nos. earth stud, including angle iron frame work at bottom with legs of minimum 600 mm height made out of 75x75x5 mm MS angle iron including all civil works like excavation, PCC, brick work pedestal, plastering, refilling etc as required. The control wiring shall be of minimum 2.5 sq mm size FRLS , PVC insulated and feeder pillar shall have the following switch gears as per the approved drawing.
INCOMER
2 Nos-100A,25KA, 4 pole MCCB with thermal release & adjustable O/L setting 0.8-1.0xln and RYB, ON,OFF & trip indicator with control MCB Make- L&T Cat no: DN0-100C or equi. approved
BUSCOUPLER
1 No-100A,25KA, 4 pole MCCB with thermal release ON & OFF indicator with control MCB Make- L&T Cat no: DN0-100C or equi. approved
Busbar
1 Set of 100 Amp(Minimum) TPN busbars of high conductivity electrolytic grade aluminium with heat shrinkable colour sleeves & DMC/SMC supports
Outgoing
2 Nos-100A,25KA, 4 pole MCCB with thermal release & adjustable O/L setting 0.8-1.0xln and RYB, ON,OFF & trip indicator with control MCB Make- L&T Cat no: DN0-100C or equi. approved
8 nos.- 32 Amp, 4P, 10KA MCB with suitable size connector & copper flexiable wire
Other Accessories
Internal connections, industrial connectors for cables to be provided.There shall be electrical & mechanical interlocking between incommers & bus coupler and 50x6 mm AL common Earth & any other accessories etc as required. Control wiring shall be done with minimum 2.5 sqmm copper FRLS flexible wire.
Earthing with GI earth pipe (B-Class) 4.5 mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providng and laying 6 SWG dia. GI wire on surface or in recess for loop earthing along with the existing cable on surface/recessed/in cable trench or in pipes etc. complete as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
M/s. Shree Gokulesh Electric and Engg CO
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
Bajaj Electricals Limited
SARASWAT ENGINEERING SERVICES
GAYATRI ELECTRICAL
J D ELECTRIC WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .