Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹48.0 L+₹78,752.47 (1.67%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹50.3 L+₹3.0 L (6.40%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹50.5 L+₹3.2 L (6.85%)Rejected-Finance 17 NO TIKIA MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PGS KOLKATA 700120 WB | KOLKATA | 24 PGS | WB | 700120 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹52.0 L+₹4.8 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
3 Dec 2022, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata 700120
ADDN/ ALTN TO ANNEXE OF BLDG NO. 04, BLDG NO. K-131, SPECIAL REPAIR TO BLDG NO. T-11 AND UG CABLE, POLES AND CONNECTED ACCESSORIES AT VARIOUS LOCATION AT BARRACKPORE UNDER GE BARRACKPORE
2022_MES_562053_1
8721/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹87,000
Yes
19 Jan 2023
9 Nov 2022
5 Dec 2022
9 Nov 2022
3 Dec 2022
26 Nov 2022
Amount
PART-I Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and removing from site completed all as specified and directed.
Taking down of shutters of any description not exceeding 1 Sqm each and removing from site completed all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and refixing in same opening after easing and adjusting completed all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work ((reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes of 100 mm dia (internal), jointed in cement mortar and taking out of trenches complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes of 75 mm dia (internal), jointed in cement mortar and taking out of trenches complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete etc all as specified and directed.
Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete in sunken floor complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in brick, concrete wall for fixing of hold fast and like etc including necessary form work complete all as specified and directed.
M&L for RCC (1:1.5:3) (nominal mix) type A1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (1:1.5:3)(nominal mix) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for RCC (1:1.5:3) (nominal mix) type A1 (using 20mm graded crushed stone aggregates) as in chajjas complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for 25mm thick damp proof course to horizontal surface including necessary form work in cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
M&L for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
S&F of 35 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
M&L for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F in repairs of 25mm dia aluminium, powder coated (wood colour finished), single curtain rails (wall thickness of curtain rails not less than 1mm) including funnels etc complete all as specified and directed.
S&F of MS bracket (heavy duty), powder coated of best quality as approved by GE suitable for fixing 25mm bore curtain rails fixed in wall complete all as specified and directed.
S&F in repairs of continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 40mm complete all as specified and directed.
S&F in repairs of 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, brass polished finished complete all as specified and as directed.
S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed.
S&F of 100 mm mortice lock vertical type of brass with 4 lever completed all as specified and directed.
S&F of aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg as fixed complete all as specified and directed.
S&F of TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of rolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F of mild steel hold fast made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 290-0 Gde-E-165 complete all as specified and as directed.
M&L of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F of steel windows (factory made) with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive wiremesh complete all as specified and directed.
S&F for mild steel work in tubular trusses and purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including preparation of steel surfaces and painted with one shop coat zinc chrome primer paint complete all as specified and directed.
S&F of anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including 4mm thick non asbestos fibre building board fixed and laid on aluminium frame work as per SSR 2009 (Part-I), clause No. 10.38.1 of page No. 227 including three coats of white wash after preparation of surfaces complete all as specified and as directed.
S&F of Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc conforming to Fe-410-W (Gde-E-250) quality -B complete all as specified and directed.
S&F of 1.25mm thick mild steel plain black perforated sheet of holes in dia 50mm in wall cladding , steel gates and similar works complete all as specified and directed.
S&F for mild steel screw bolts (machine made) 11 to 15mm with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolt exc. 100mm but not 150mm complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminum frame (powder coated) for doors , windows, ventilators with one or more rebates (sliding & fixed type) including jointing cleat for fixing etc after and including taking down of existing old unserviceable frame complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller after and including taking down of existing old unserviceable shutter complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium double leaf window and ventilator shutters, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat ofindustrial bitument 85/25 @ 1.2Kg /Sqm over it all as per manufacturer's instructions including taking down old unserviceable treatment complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M& L for applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and as directed.
S&F for 18/19 mm thick veneered finish prelaminated particle board fixed in cupboard shelves & shutter exterior grade, prelaminated in both side with decorative choice lamination, fixed with screw complete all as specified and directed.
M&L for 12 mm thick medium density fibre board, exterior grade, fixed with screw/beading to aluminium frame work complete all as specified and directed.
M&L for providing 12mm thick gypsum board false ceiling fixed with standard GI frame work with and including plaster of paris decorative type cornice all around at the junction of wall and ceiling, etc. GI primeter channel 0.55mm thickness with to unequal flages of 20mm x 30mm and web 27mm fixed for the primeter of the wall/ partition using nylin sleeves and screws at 450mm, etc. intermidiate channel 0.9mm thickness with two equal flanges of 15mm each andweb 45mm suspended from the soffit 120mm c/c with ceiling hangers with GI cleat, ceiling section 0.55mm thickness with two equal flange 26mm thick & web of 50mm fixed a cross of the intermediated channel @ 457mm c/c with connecting clips to hold the boards ceiling hanger 0.50mm thickness with two unequal flanges of 10mm & 25mm used to suspended intermediate channel from soffit cleat @ 1220mm centre, connecting clip 2.64mm dia it is used to hold the ceiling section to the intermediate channel soffit cleat 0.55mm thickness with two uequal flanges 37mm & 25mm and web of 25mm used at 1220mm c/c to the rwal plug to suspended ceiling hanger, rwal plug of 12.7mm dia used @ 1220mm c/c in both directions, screws self drilling and tapping screws with under head cutter 25mm and 35mm long used to fixed board to the metal frame @ 200mm c/c (12mm away from the edge and 40mm from the corners) complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove, dust etc complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath, floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & hard standing including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof padding complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B-2 (using 12.5mm graded crushed stone aggregate) as in floor, finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
All as per Item No.81.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 25mm thick screed bed of cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid over and including 10mm cement plastering in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20 mm thick granite slab (of any type with table rubbed and polishet) in steps, jambs, pillars, win?dow-cills, cooking plat?forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing complete all as specified and directed.
M&L for vitrified light shade (shade as approved) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set over and including 15mm screed bed in cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
Round chamfering, to the edges of granite not exceeding 15mm wide on granite stone shelves complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling/ chajja/ projected slab, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on sunken floor surfaces in cement mortar (1:3) mixing with WPC @ 200ml/ 50kg of cement or as per manufacturer's instructions, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 15 mm thick on RCC roof surfaces in cement mortar (1:4) mixing with WPC @ 200ml/ 50kg of cement or as per manufacturer's instructions, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for 20 mm thick screed bed with cement mortar (1:4) mixied with water proofing compound @ 200ml/ 50kg of cement or as per manufacturer's instructions on roof surfaces over roof padding surface shall be finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface used smart painting technic complete all as specified and directed.
M&L for applying one coat of white wash on old wall surface including preparation of old surface used smart painting technic complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface used smart painting technic complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces used smart painting technic complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces of walls used smart painting technic complete all as specified and as directed.
Material & Labour for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (as approved by AO) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including preparation of new plastered surfaces used smart painting technic complete all as specified and as directed.
Material & Labour for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (as approved by AO) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including complete removal of existing treatment and preparation of plastered surfaces used smart painting technic complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint after preparation of steel surfaces of any description over 10cm width or girth used smart painting technic complete all as specified and directed. (Note:- Priming coat already covered under item No. 59.00 here-in-before.)
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth used smart painting technic complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, not otherwise described, over 10cm in width or girth used smart painting technic complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width used smart painting technic complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth used smart painting technic complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane including hacking out old brorken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 3mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane including hacking out old brorken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 5.5mm thick sheet glass panes, ordinary quality and glazing fixed with aluminium bead and gasket suitable for aluminium frames pins in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F for 5.5mm thick sheet glass panes, ordinary quality and glazing fixed with aluminium bead and gasket suitable for aluminum frame pins in squares exceeding 0.50 sqm in each pane complete all as specified and directed.
Disconnecting existing water tanks of (exceeding 250 & not exceeding 500 litres in capacity), setting aside (or lowering if required) and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in position with required fittings complete all as specified and directed. (NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank)
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F in repairs of 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F in repairs of 15 mm bore stop valve/angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F of 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes fixed complete all as specified and directed.
S&F of 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs of 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F of 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F in repairs of vitreous china wash basin, white, flat back, size 580 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand including chromium plated 32mm bore bruss waste fittings for glazed ware basins with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F in repairs of vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 110mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal provided with access door complete all as specified and directed.
S&F of 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal provided with access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs of sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall, ceilings or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F in repairs of 50 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall, ceilings or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F of 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
M&L for PVC (SWR) 'P’ trap of 110mm bore complete as complete all as specified and directed.
PART-II Taking down unserviceable submain wiring aluminium etc and making good the disturbed surfaces of walls/floor etc matching with the existing surface.
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One light point controlled by two-way switches .
One ceiling fan/exhaust fan point controlled by one switch .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One 3 pin 5 amps socket point controlled by one 5/6 amps switch on independent board .
All as per Item No.146.00 here-in-before but point wiring with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm for one 6pin, 6/16Amps socket outlet point controlled by one 16Amp switch on independent board complete all as specified and directed.
All as per Item No.146.00 here-in-before but point wiring with 4.0 sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4.0 sqmm for one 3 pin, 15/16Amps socket outlet point controlled by one 15/16Amp switch on independent board complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular bell push, 6Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete all as specified and directed.
S&F of modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16 Amps, 6 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 for tubes /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size other fixing accessories complete all as specified and directed.
S&F of LED luminaire 600 mm x 600 mm, 35/36 watts, 220 Volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete all as specified and directed. (Make- CG cat No. LCTLRNE-36-FO-CDL or equivalent of Havells/Bajaj/Philips or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F MCBs SP, 6 to 32A mps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F MCBs SPN 32 Amps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F MCBs SPN 40 Amps, 240 Volts, 50Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs all as specified and as directed by EIC.
S&F of MCB, four pole, 40 to 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete as in repair all as specified and directed.
S&F of MCB, four pole, 63 to 100 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete as in repair all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note for item No. : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / L&T Cat No. DBTPN004GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of PVC conduit of heavy duty of size not less than 20mm dia from looping box to street light connector holding with MS clamp of size 25mm x 2mm thick at every 1m used in each pole 04 Nos. of clamp with necessary nuts, bolts & washers, etc. and inclding 1100 Volts grade heavy duty cable PVC sheathed three core multistranded copper conductor in street light connection from pole junction box at bottom to street light fixed on swaged pole of cable of size 1.5 Sqmm including making all necessary connection complete including taking down old unserviceable cable complete all as specified and as directed.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 75 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 115mm x .75mm laid dry flat complete all as specified and directed .
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for 40 mm bore GI pipe (medium grade) fixed with wall with maximum span of 4.0 meters suitable for hanging of ceiling fan of 1200 mm sweep with and including necessary cutting hole in brick/stone wall and making good the same with PCC (1:2:4) type B-1 as required at complete all as specified and directed.
Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed.
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 32mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of LED street light fitting 70-75 Watts 230 Volts, AC, Out door type with made up of pressure die cast aluminium housing with polycarbonate cover and high power LEDs and seconadary lenses with IP-66 protection, uotp 10 KV SPD included with impact and corrosion resistant complete with driver and lamp complete including taking down old unserviceable light fitting complete all as specified and directed. (Make : Crompton Greaves Cat No LST-70-CDL-M/ Bajaj Cat No BRTFG 72 W LED/Havells Cat No. ENDURAOMNIPLUSSL70WLED757SASYTOPC or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of LED aviation light fittings with 20 Watts dependent sensor light, IP65 protection with all fixing accessories including all electric connection and control switch complete including taking down old unserviceable light fitting complete all as specified and directed.
Supply, fixing and commissioning water heater storage type, eletric operated, capacity 25 Litres, BEE 5 Star rated, copper inner tank, complete with all connected accessories suitable for AC supply, 240 volts, 50 Hz including connecting with water supply pipe line and all water and electrical connection complete with necessary PVC connection pipe all as specified and directed.
S&F of ceiling fan of size 1400 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, BEE 5 Star rated as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F of FRP looping box 2mm thick suitable for three phase 415 volts AC supply with 04 Nos aluminium bus bar rating 63 amps with one No MCB 6 Amps , SP having size 400X300X190mm complete including MS flat iron clamps of size 25mm x 5mm thick, 2 Nos, nuts, bolts & washer and other fixing accessories to fixed with swaged pole including taking down old unserviceable box complete all as specified and directed. (Make- Sintex/Hansel/ National/ Star electric Eng Co./Universal switch gear control or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI strip of size 32X6mm as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable earthing complete all as specified and directed. (Note: Galvanised iron strip of size 32X6mm upto 7.5m long including testing is deemed to be included with quoted rate).
Material and labour for painting to steel tubular pole of any type/ size/length with complete removing of existing paint by using wire brush and using emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI bracket, cross arms etc. and applying two coats of synthetic enamel paints upto 1.2mtr height in black and yellow strips (as directed by Engr-in-Charge) colour and remaining portion shall be silver colour over two coats of red oxide chrome primer on steel surface with smooth finish and painting work to be carried out with safety equipments and tools will be own arrangement complete all as specified and as directed.
Taking down old unserviceable flush mounting steel enclosure clad plug any type and capacity complete all as specified and directed.
Taking down old unserviceable 40mm dia GI tubing complete all as specified and directed.
Taking down old unserviceable distribution board any type and capacity complete all as specified and directed.
Taking down old unserviceable GI bracket complete all as specified and directed.
Taking down old unserviceable GI wire earthing complete all as specified and directed.
PRASAD ENTERPRISE
PIONEER TRADING
B N ENTERPRISE
N C DUTTA
SENCO
SWAPAN CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .