Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.5 CrAccepted-AOC JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | ₹1.5 Cr | L-1 | Accepted-AOC AOC |
| 2 | L-2₹1.6 Cr+₹7.0 L (4.60%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | ₹1.6 Cr+₹7.0 L (4.60%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹1.7 Cr+₹18.7 L (12.3%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹1.7 Cr+₹18.7 L (12.3%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹1.8 Cr+₹25.1 L (16.5%)Rejected-Finance | ₹1.8 Cr+₹25.1 L (16.5%) | L-4 | Rejected-Finance Being L4 |
| 5 | L-5₹1.8 Cr+₹32.6 L (21.4%)Rejected-Finance OPP GOLAI HOTEL RANCHHOD LANE JUBILEE ROAD PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | ₹1.8 Cr+₹32.6 L (21.4%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
13 Jan 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
PROVISION OF INFRASTRUCTURE FOR INSTALLATION OF SHORE BASED SURFACE SURVEILLANCE RADAR AT NAVAL COASTAL BATTERY, PORBANDAR
2023_MES_631453_1
8911/E8
Open Tender
Civil Works
Lump-sum
270 days
PORBANDAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NAVY) PORBANDAR
₹2.4 L
Yes
14 Feb 2024
7 Dec 2023
15 Jan 2024
7 Dec 2023
13 Jan 2024
6 Jan 2024
Amount
SCH 'A' PART-I : "(BUILDING & STRUCTURES)" brought forwarded from Serial Page No. 19
SCH 'A' PART-II : "EXCAVATION , SITE CLEARANCE, & EARTHWORK" Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 21 (R)
SCH 'A' PART-III : "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 23(R)
SCH 'A' PART-IV : "INTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 27 (R)
SCH 'A' PART-V "LIGHTENING PROTECTION" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 28
SCH 'A' PART-VI"AIR CONDITIONING AND REFRIGERATION" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 29
SCH 'A' PART-VII "FIRE FIGHTING" Total of Schedule 'A' Part-VII brought forwarded from Serial Page No. 32 (R)
SCH 'A' PART-VIII "ROAD/PATH" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No.33 (R)
SCH 'A' PART-IX "SEWAGE DISPOSAL" Total of Schedule 'A' Part-IX brought forwarded from Serial Page No. 34
SCH 'A' PART-X "AREA DRAINAGE" Total of Schedule 'A' Part-X brought forwarded from Serial Page No. 35
SCH 'A' PART-XI "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-XI brought forwarded from Serial Page No 36
SCH 'A' PART-XII "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-XII brought forwarded from Serial Page No.38 (R)
SCH 'A' PART-XIII"MISC WORKS"
" INTERNAL ELECTRIFICATION"
Supply and fixing LED light fitting surface mounted 1'x1 ' of capacity 15Watt of 240V Environment friendly High quality LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination complete with all connected accessories.
S&F DLP U PVC trunking system Plastic adoptable type 150x50mm with two compartment duly covered installed with suitable support joints including all accessories complete all as specified and as directed.
Supply and fixing TP&N distribution board with double door vertical type TPN DB made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating,suitable for MCCB for capacity 100Amp, 16 KA, Incomer 4 ways 415 Volts made up of CRCA sheet with busbar rating 200 Amps Adjustable thermal (70% to 100%) & Fixed magnetic setting type including grouting in the wall, cutting & chasing etccomplete all as specified . Make: Havells/ L&T/ABB
M & L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth lead wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
" LIGHTENING PROTECTION"
Supply & fix porcelain insulator for laying of ligtning strip on the roof/ wall for maintain distance from suface and strip of suitable size and distance between two insulator minimum 1mtr complete all as specified and directed.
Supply and fixing Earthing conductors connecting junction box with copper plate as suitable size and connected to separate copper cable to equipement etc complete all as specified and as directed.
Supply and fixing of single dome LED aviation obstruction light comprising of aluminium housing with polycarbonate enclosure with accessories, complete all as specified and directed. Make : Bajaj/Crompton or equivalent
" FIRE FIGHTING"
Supply, installation, testing and comissioning of ISI Marked 2 core x 1.5 Sqmm, multistranded Copper Conductor, FRLS Armoured cable, RED in Colour, laid on surface with GI saddle-spacers every 0.3 meters complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling complete all as specified and directed.
S & F GI slotted type cable trays of the following sizes using MS angle, channels, flats etc. All MS supports used shall be given one coat of red oxide primer & 2 coats of synthetic enamel paint of approved colour of size 100 x 50 mm x 2mm complete all as specified and directed.
S & F Fire extinguisher water CO2/stored pressure type 9 ltr capacity (IS:940/6234) complete all as specified and directed.
S & F Fire extinguisher Dry chemical powder type (ABC), 5 Kg (IS: 2171/13849) capacity complete all as specified and directed.
S & F Fire Exit sign board made up of acrylic sheet of suitable size and standard font for indicating fire exit complete all as specified and directed.
"SEWAGE DISPOSAL"
M&L for walling of Porbandar stone masonry uncoursed well bonded and solidly hearted built in CM 1:6 brought up to courses complete all as specified and directed.
"AREA DRAINAGE"
M&L for walling of Porbandar stone masonry uncoursed well bonded and solidly hearted built in CM 1:6 brought up to courses complete all as specified .
"ROAD/PATH"
M&L for walling of Porbandar stone masonry uncoursed well bonded and solidly hearted built in CM 1:6 brought up to courses complete all as specified and directed.
"EXTERNAL WATER SUPPLY"
Supply and Fix DOL Starter suitable for 3 ph, 415V, 50M head and Discharge minimum 400LPM capacity submersible pump set of 5 HP complete all as specified and directed.
Supply and fixing of submersible pump set suitable for 415 V ,3 phase system having capacity discharge rate minimum 400 LPM , Head is 50 mtr, 5 HP, copper wounded, cast iron material having 50mm Delivery size, 3000RPM complete all as specified and directed.
"EXTERNAL ELECTRIC SUPPLY"
Supply and fix LT cable route indicator PCC with embossing LT cable with height not less than 600 mm , situated on PCC base all as per standard specification and as directed.
"REFRIGERATION & AIRCONDITIONING"
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% suitable upto 2 Tonne Acs and water cooler complete all as specified and directed.
"DG Set"
Supply, installation, testing and commisioning of silent Diesel Engine driven generating set of capacity 40 KVA 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and complete foundation etc. (A) Diesel Engine:- The engines are rated at 1500 RPM BHP not less than 200 BHP and conform to ISO 8528 specifications, radiator cooled, four stroke and multi cylinder, confirming to BS 5514 / ISO 3046 with the following accessories:- (a) Elecrical starter motor 12 V DC - 01 Nos (b) Battery charger 12V DC - 01 No (c) MICO fuel system with mechnical governor (d) Dual spin on fuel filter (e) Spin on full flow lub oil filter (f) Residential silencer (g) Dry type air cleaner (h) Recovery bottle (j) Shut off coil with safeties for LLOP / HWT (k) Fly wheel and flywheel housing (l) first fill of lube oil and coolant (B) Alternator:- Brushless type, scren protected, revolving filed, self excited, self regulated through an AVR. The alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lagging) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000/IS 4722. The alternator has the following features:- (a) + 1.0% Voltage regulation (max) in static condition. (b) IP:23 Enclosure (c) Permissible overload of 10% for one hour in 12 hours operation (d) Mounting Arrangement:- The Engine and alternator are mounted on a common MS fabricated base frame with AVM pads Note: Foundation for DG set deemed to be included in quoted rate. (e) DG Set must comply emission limit as per CPCB-II norms
AADESH CONSTRUCTION
RAJ ENTERPRISE
J J ENTERPRISES
Shree Ashapura Construction Co
shree chamunda enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .