| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED L1 | |
| 2 | L2₹30.4 L+₹18,070.50 (0.60%)Rejected-Finance 18 MOTI BAGH BABYAL ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being rejected L2 | |
| 3 | L3₹31.3 L+₹1.1 L (3.64%)Rejected-Finance | L3 | Rejected-Finance Being rejected L3 | |
| 4 | L4₹34.6 L+₹4.3 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Being rejected L4 | |
| 5 | L5₹38.1 L+₹7.9 L (26.1%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L5 | Rejected-Finance Being rejected L5 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
21 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI ABHINANDAN KUMAR MISHRA EE IDSE
GE SOUTH AMBALA CANTT
CA NO GE SOUTH AMB 64 2022 2023 COMPREHENSIVE REPAIR AT MARRIED ACCN OF KE LINE, PIRU SINGH LINE, ICC LINE AND ML LINE AT AGE BR II UNDER GE SOUTH AMBALA CANTT
2022_MES_571142_1
GE(SOUTH)/AMB-64/2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AMBALA CANTT
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH AMBALA CANTT
₹1 L
Yes
1 Feb 2023
24 Dec 2022
23 Jan 2023
24 Dec 2022
21 Jan 2023
7 Jan 2023
24 Dec 2022 - 6 Jan 2023
Amount
Supply and fixing of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa tensile strength as in roof covering/cladding to wall, fixed with self tapping screws or J type hooks including rubber washer etc complete including dismantling asbestos cement corrugated or semi-corrugated sheets etc; complete all as specified and as directed.
Supply and fixing of pre-painted galvalume aluminium zinc coating GI based galvanised plain mild steel sheeting 0.50 mm thick of any colour, having 550 Mpa tensile strength as in roof covering/ ridges and fixed with self tapping screws or J type hooks including rubber washer etc complete including dismantling asbestos cement corrugated or semi-corrugated sheets etc; complete all as specified and as directed.
Supply and fixing of rolled mild steel works as in bands, straps, wind ties, angle cleats and similar small articles etc conforming to Fe-290 Gde E-165 including dismantling existing mild steel complete all as specified and as directed.
Material and labour for brick work with sub class ‘B’ bricks, straight or curved on plain exceeding 6 metre mean radius in cement mortar (1:6) including demolition of brick work built in cement mortar including demolition of old brick/stone masonry built in cement mortar of any description including all quoins, archs, pillars etc complete all as specified and directed.
Taking down cement plaster of any description and in any position including raking out joints, hacking for key, scrubbing down with water etc of any thickness complete all as specified and as directed.
Material and labour for rough cast plaster with and including 15mm thick rendering in CM 1:3 on brick wall or concrete surface as specified in clause 14.22 of SSR Part-I complete all as specified and directed. Note:-(i) After applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. (ii) The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered. (Upto height 15 mtrs)
Material and labour for 15mm thick rendering in cement mortar (1:4) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 15mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of exposed brick wall surface by cleaning the surface wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ratio of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. NOTE : - Further treatment over the surface so achieved will be carried out only after approved of the same by GE.
Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with hand roller, over a coat of alkaline resistant primer over a coat of wall care putty not less than 1mm thick as per manufacturer's instruction complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer on walls complete all as specified and directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by washing rubbing and applying one coat of cement base paint complete all as specified and as directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by washing rubbing and applying one coat of oil bound distemper complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed.
Dismantling timber scantling 40 Sq. cm and over in section, in any position of unframed/ framed work complete all as specified and as directed.
Supply and fixing of mild steel, rolled sections as in main or cross beams, hip and jack rafters, purlin where connected to comman rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates conforming to grade Fe-410(Gde 250), complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for cutting holes into or through brick walls built in cement mortar exc. half brick and not exceeding full brick for inserting hold fasts,, MS work etc and making good disturbed portion in cement mortar 1:3 or PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, complete all as specified and as directed.
Material and labour for taking down ceiling fan, sealing cable end, dismantling blades and removing fan from site and keeping in safe custody for reuse and hanging same ceiling fan complete of any sweep and connecting up including provision of three core PVC insulated and unsheathed copper conductor cable of size 0.5 Sqmm from ceiling rose or connector to fan complete all as directed.
Supply and fixing of semi perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 475 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge including dismantling existing asbestos sheet false ceiling textile coverings including frames (if any) and cover fillets complete all as specified and directed.
Supply and fixing of PVC false ceiling consisting of 600 mm x 600 mm, 5mm (+ 0.25) thick plain embossed PVC sheet of density 600 Kg/Cbm manufactured by an ISO-9001-2015 certified company, used as panel insert in a frame work made using anodised aluminium T-section of sizes 1" x 1" (25 mm x 25 mm, 1 mm thick) in square pattern of grid sizes of 2' x 2' (600 mm x 600 mm). The aluminium framework is supported from the ceiling with the help of 'J' hook and G.I. wire / 4mm MS rods of required sizes to maintain proper level etc. The aluminium frame work is supported on the side wall with the use of aliminium L- Section of size 1"X1" (25mmX25mm, 1mm thick) Angles etc. complete as per direction of Engineer - In- Charge, Manufacturer's specification and drawing including taking down existing ceiling boards (fibre, pulp, insulation etc) or insulation boards/slab etc ant thickness including cover fillets of any description complete all as specified and directed.
Supply and fixing of false ceiling at all heights of perforated with fleece 595 mm x 595 mm x 0.5 mm TEGULAR EDGE TILES in global white powder quoted with 60-70 micron front coating and including regular 24 mm wide T-section flange colour white having rotary stitching on the main runner with web height 26 mm, exposed grid system including frame work comprises of main runner spaced at 1200 mm max (centre to centre), hangers (GI wire of 4 mm dia) to be fixed by hiliti consisting of HLS sleeve anchor fastencer of thread size 6.5 mm x 25/5 with soffit cleat made of galvinised steel of size 27 mm x 37mm x 25mm x 1.6mm and level clip in dimensions of 85mmx30mm 0.8mm at 600x1200 intervals. The last hanger at the end of each main runner shoud not be greater than 450 mm from the adjacent wall. Flush fitting 1200 mm long cross tees (with double stiching) to be interlocked between main runner at 600 mm shall be 'T'shape section with single rotary stitching made of GS sheet and of size 15 mmx32mm and 3000mm long, crosssed runner shall be 'T' shaped with double rotary stiching made of GS sheet and size 15 mmx 32mm x 1200 mm long and perimeter wall angle shall be made from GS sheet and of size 19mm x 19mm and 3000mm long, colour white, centre to form 600 mm x 600 mm modules, cut cross tees longer than 600 mm to be supported independently, 600mm x 600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be wall angles of size 3000x22x22mm, secured to walls at 450mm max (centre to centre), complete including taking down existing ceiling boards (fibre, pulp, insulation etc) or insulation boards/slab etc ant thickness including cover fillets of any description complete all as specified and directed. .
Material and labour for re-securing/ adjusting existing false ceiling grid any type and making required tightning to remove sag portion/ depression in false ceiling grid including replacement of missing sections / suspenders etc complete all as specified and directed.
Supply and fixing of steel tube 50 mm bore, medium grade galvanized, ISI marked, fixed to walls as in additional support of ceiling, etc including cutting & chasing in wall and making good with PCC to old existing surface complete all as specified and directed.
Matrerial and labour for cutting or uprooting with of grass/vegetation over roof surfaces and roughning old brick tile/concrete surfaces by picking, sweeping clean with wire brusing and washing down with water to remove dust etc, including flushing & filling damaged/open joints junction of parapets in CM 1:3 and applying neat cement slurry 3.0 Kg/sqm complete all as specified and directed.
Matrerial and labour for 40mm thick average thickness PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in levelling course / padding over roof surface with and including water proofing compound @ 2% by the weight of cement, surface to be finished even and smooth with using extra cement to receive APP membrane etc complete all specified and directed.
Material and labour for APP polymeric water proofing treatement to roof using membrane minimum 3 mm thick and weighting not less than 3.6 kg/sqm , black finish reinforced with non-woven polyster matt (Weight not less than 150 gms/Sqm) with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, by the same membrane manufacturer of density 0.87 to 0.89 kg/ltr at 25' C temprature and viscosity 70-160 cps over the primer coat, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side and 150 mm at the ends and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm below APP and two coats water proofing paint with aluminium finish on top of laid APP surfaces including preparation of surface complete all as specified and directed. NOTES : - (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor' risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. Contractor's quoted rate for this item shall deemed to be inclusive of this aspect.
Material and labour for plain cement concrete 1:2:4 type B-1 (using 20 mm graded mechanically crushed stone aggregate) as roof kerbs or mud stops and the like, rounded or chamfered on edges complete including demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Cleaning and removing all scale and dirt, etc from existing water storage tanks of capacity exceeding 250 litres and not exceeding 500 litres by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from tank including cleaning from mouths of circulating pipes, to entire satisfaction of Engr-in–charge of cleaning, including writing date of cleaning with oil paint of of visible colour in font size not less than 100 mm high complete all as specified and directed. (The rates includes for disconnecting of existing water tank, lowering if required and hoisting, reconnecting and refixing in same position after cleaning ) NOTE: - (i) The whole process of disconnecting, reconnecting and refixing in same position after cleaning shall be done on the same day, if failing so, Rs. 100/- shall be deducted for each tank per day from the contractor due. (ii) A separate register to be maintained by contractor for cleaning and occupant signature with date to be obtained in it.
Cleaning and removing all scale and dirt, etc from existing water storage tanks of capacity exceeding 500 litres and not exceeding 1000 litres by emptying, drying and cleaning the tank by scrubbing the dust with wire brush from tank including cleaning from mouths of circulating pipes, to entire satisfaction of Engr-in–charge of cleaning, including writing date of cleaning with oil paint of of visible colour in font size not less than 100 mm high complete all as specified and directed. (The rates includes for disconnecting of existing water tank, lowering if required and hoisting, reconnecting and refixing in same position after cleaning ) NOTE: - (i) The whole process of disconnecting, reconnecting and refixing in same position after cleaning shall be done on the same day, if failing so, Rs. 100/- shall be deducted for each tank per day from the contractor due. (ii) A separate register to be maintained by contractor for cleaning and occupant signature with date to be obtained in it.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, 8 to 9 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, 7 to 8 mm thick as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:3) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in levelling course etc including demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed or layer in cement mortar (1:4) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles, area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, 7 to 8 mm thick as in vertical surfaces such as dado, skirting, set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in white or coloured cement to match the surface over and including 10 mm thick rendering in cement mortar (1:3) including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for premium quality glazed ceramic coloured tiles of size 350x250mm/450x300mm x 7mm thick gloosy/mat finish as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry @ 3.00 kg/square metre and pointed in coloured cement to match with and including 10 mm thick rendering in cement mortar 1:3 finished rough surface to receive tiles including dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for 75mm thick PCC 1:2:4 type B2 using 40mm graded mechanically crushed stone aggregate as in hardstanding/paths, finishing the concrete surface even and smooth without using extra cement including forming joints and filling with mixture of bitumen and sand in ratio (1:1) by weight including necessary formwork etc and including demolition of existing old cement concrete in ground floors and pavings n.exc 15cm thickness (below or above) ground level complete all as specified and directed.
Material and labour for 100mm thick PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone as in sub base of floor / hard standing finished, complete all as specified and directed.
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; etc including dismantling of existing tiles etc including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
NOTE:- Amount of credit of Rs. 94,900.00 for retrieved materials is mentioned in Schedule of Credit Page No 19(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
Gupta Enterprises
Parveen Kumar
m/s parmod kamar
A N BUILDERS
M/s R.K.Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .