Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | ₹7.9 L Quoted ₹8.1 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹10.2 L+₹2.2 L (26.6%)Rejected-Finance | ₹10.2 L+₹2.2 L (26.6%) | L2 | Rejected-Finance Other than L1 Bidder |
| 3 | L3₹12.5 L+₹4.4 L (54.6%)Rejected-Finance | ₹12.5 L+₹4.4 L (54.6%) | L3 | Rejected-Finance Other than L1 Bidder |
| Sl No | Description | Qty | Unit | KRISHNA ENGINEERING ENTERPRISES L1 | ARORA ENTERPRISES L2 | M/S AKHILESHWAR ASSOCIATES L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for descaling and cleaning of shell and tube water cooled/air cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with chemical, suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, in every 03 months etc complete all as directed by Engr-in-Charge.Note:- Cost of transportation and all petty spares required/from dismantling to recommisioning deemed to be included in the quoted rates.
(a) 12.5 x 4 TR (50 TR)capacity at U/G Signal Central AC Plant | 8 | Per Unit | 10,500 ₹84,000 | 10,000 ₹80,000 Lowest | 11,500 ₹92,000 |
| 2.00 | M& L for servicing along with chemicals for pahar pur cooling tower of 40 TR capacity all as specified and as directed. | 2 | Each Job | 7,000 ₹14,000 Lowest | 10,000 ₹20,000 | 11,500 ₹23,000 |
| 3.00 | M&L for complete servicing of 01 AHU of 40 TR including chemical cleaning of cooling coils, filters etc. including cost of all chemicals and consumable materials required at site all as specified and as directed. | 4 | Each Job | 9,000 ₹36,000 Lowest | 10,000 ₹40,000 | 11,500 ₹46,000 |
| 4.00 | M&L in complete servicing of Y strainers of 2 chilled water and 2 condenser water pumps including replacement of strainer mesh whenever required all as specified and as directed. | 3 | Each Job | 5,500 ₹16,500 | 2,000 ₹6,000 Lowest | 2,750 ₹8,250 |
| 5.00 | S&F in replacement of sprinkler and spray nozzles high pressure assembly for cooling tower as per site all as specified and directed. | 4 | Each Job | 6,000 ₹24,000 | 5,000 ₹20,000 Lowest | 5,240 ₹20,960 |
| 6.00 | S&F in replacement of air filters of ahu of 40 TR, complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | 3,000 ₹12,000 | 1,000 ₹4,000 Lowest | 1,350 ₹5,400 |
| 7.00 | M & L for servicing to condensor coil assembly including pressure test with nitrogen gas and soldering to leakage with copper soldering machine complete all as specified and as directed | 4 | Each | 5,200 ₹20,800 | 2,000 ₹8,000 Lowest | 2,250 ₹9,000 |
| 8.00 | M&L in replacement of PLC controller for compressor of make bluestar, complete all as specified and directed. | 4 | Each | 8,500 ₹34,000 Lowest | 10,000 ₹40,000 | 9,500 ₹38,000 |
| 9.00 | Supply and fix in replacement Pressure transducer control device differantial type all as specified and as directed. | 2 | Each | 8,000 ₹16,000 | 3,000 ₹6,000 Lowest | 3,650 ₹7,300 |
| 10.00 | S&F in repair Hp/Lp switch as per site requirement complete all as specified and directed. | 2 | Each | 2,500 ₹5,000 Lowest | 3,000 ₹6,000 | 3,250 ₹6,500 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Jun 2026, 6:00 pmClosed
CWE Rajouri
HQ CWE RAJOURI
REPAIR OF CENTRAL AC PLANT AND CONNECTED ITEMS AT RJOURI UNDER GE 862 EWS
2026_MES_752067_3
CWE/RAJ-95/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAJOURI
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 862 EWS
₹30,000
Yes
3 Sept 2026
1 Jun 2026
22 Jun 2026
1 Jun 2026
15 Jun 2026
8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for descaling and cleaning of shell and tube water cooled/air cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with chemical, suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, in every 03 months etc complete all as directed by Engr-in-Charge.Note:- Cost of transportation and all petty spares required/from dismantling to recommisioning deemed to be included in the quoted rates.
(a) 12.5 x 4 TR (50 TR)capacity at U/G Signal Central AC Plant | 8 | Per Unit | - | - |
| 2 | M& L for servicing along with chemicals for pahar pur cooling tower of 40 TR capacity all as specified and as directed. | 2 | Each Job | - | - |
| 3 | M&L for complete servicing of 01 AHU of 40 TR including chemical cleaning of cooling coils, filters etc. including cost of all chemicals and consumable materials required at site all as specified and as directed. | 4 | Each Job | - | - |
| 4 | M&L in complete servicing of Y strainers of 2 chilled water and 2 condenser water pumps including replacement of strainer mesh whenever required all as specified and as directed. | 3 | Each Job | - | - |
| 5 | S&F in replacement of sprinkler and spray nozzles high pressure assembly for cooling tower as per site all as specified and directed. | 4 | Each Job | - | - |
| 6 | S&F in replacement of air filters of ahu of 40 TR, complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | - | - |
| 7 | M & L for servicing to condensor coil assembly including pressure test with nitrogen gas and soldering to leakage with copper soldering machine complete all as specified and as directed | 4 | Each | - | - |
| 8 | M&L in replacement of PLC controller for compressor of make bluestar, complete all as specified and directed. | 4 | Each | - | - |
| 9 | Supply and fix in replacement Pressure transducer control device differantial type all as specified and as directed. | 2 | Each | - | - |
| 10 | S&F in repair Hp/Lp switch as per site requirement complete all as specified and directed. | 2 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tender95.pdf
Tender Documents • 1.09 MB
BOQ_861240.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .