University Engineer
Repair, Renovation, Restoration work and other miscellaneous work at different pumping stations of the university campus.
290803
8/9 of 2025-26
Open
Miscellaneous Works
Vadodara
17 documents required · 15 mandatory · 2 optional
₹3,600
The Registrar, The M.S. University of Baroda
₹2.1 L
27 Mar 2026
27 Mar 2026
27 Mar 2026
17 Apr 2026
27 Mar 2026
DESCRIPTION UNIT QTY RATE AMOUNT
Removing of existing pipeline incl. removal of
specials, valves jointing material including
carting and stacking of removed material from
site of work to the department store as directed
excl. excavation and refilling. 100mm Dia DI
Pipe. Rmt. 955.00 23.00
1.1 150mm Dia DI Pipe Rmt. 285.00 28.75
1.2 250mm Dia DI Pipe Rmt. 100.00 64.40
Providing and fixing flanged D.I.D.F. / Class K-9
pipes vertically for RCC Reservoir incl. providing
clamps at every 3 mt incl. jointing materials such
as nuts, bolts, rubber packing, hydraulic testing
and necessary scaffolding etc. complete.
100mm Dia. DIDF Rmt. 540.00 2684.10
2.1 150mm Dia DIDF Rmt. 150.00 3934.15
2.2 250mm Dia DIDF Rmt. 50.00 6694.15
Providing and supplying D. I. K-9 grade pipes for
following nominal bore diameter with internal
cement mortar lining including all taxes,
insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to departmental stores, stacking
etc. complete. (IS 8329-2000). 100mm Dia.
Providing and supplying ISI mark G. I. pipes with
Couplings of following class and diameter
including all taxes, insurance, transportation,
freight charges, octroi, inspection charges,
loading, unloading, conveyance to departmental
stores, stacking etc. complete. (IS -1239) (Not
for well/tube well column pipe). Heavy Duty
Supplying of following size of HEAVY UPVC
5.0 column pipe with coupler and wire lock. 100 mm
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and supplying in standard length ISI
mark rigid unplasticised PVC pipes suitable for
potable water with ring fit joint including cost of
rings, as per IS specification no. 4985/1988
including all local and central taxes,
transportation, freight charges, octroi, inspection
charges, loading, unloading, conveyance to the
departmental stores and including cost of
jointing meterial etc. complete. Note : 1.One
coupler / ring shall be provided with each full
length pipe cost of which is included in rates
below. 2. 3% (Three) Discounted rate to be
consider for Coupler jointed pipe. 110mm Dia
Providing, laying and jointing in true line and
level 160 diametre U.P.V.C (Type B) conforming
to IS 13592-1992 with one end plain and other
end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp
of the size 160 mm diametre x 210 mm length x
196 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends,
shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement
including cost of all materials.
Providing, laying and jointing in true line and
level 110 diametre U.P.V.C (Type B) conforming
to IS 13592-1992 with one end plain and other
end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make
for drainage system pipe line, pipe shall be
jointed with each other with rubber lubricant,
pipe shall be fixed on wall using of PVC clamp
of the size 110 mm diametre x 149 mm length x
145 mm heigh at every 2000 mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends,
shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement
including cost of all materials.
DESCRIPTION UNIT QTY RATE AMOUNT
Manufacture, Supply & Delivery of Ductile Iron
Flange socket spigot bends, tees, reducers or
any other specials as per BS-EN-545/1995
Class-A series K12 suitable for use with D.I.
Pipes manufactured as per IS:8329/1994
delivery of specials is to be made to GWSSB
9.0 store or site of works any where in Gujarat
including all taxes, loading, unloading, carting,
stacking, insurance, inspection charges, octroi
etc. complete. With external bitumen & zinc
coating & internal cement mortar lining. Socket
& Spigot Type. 80 to 300mm dia.
9.1 Flanged ended - 80 to 300mm dia. Kgs. 965.00 155.00
Providing & Supplying ISI Marked PVC
Specials. Tee, Bend, Reducer etc. Job 1.00 19350.00
Providing and supplying ISI mark CI D/F Sluice
valves, butterfly valves & Reflux valves of
following class and diameter including all taxes,
insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading,
11.0 conveyance to departmental stores, stacking
etc. complete. Sluice valves as per IS - 780 &
2906 / 1984. Sluice Valve ISI Mark only. PN-1.6
With hand/wheel cap operated. (Alt-1 type long
body). 100mm Dia Sluice Valve
11.1 150mm Dia Sluice Valve No 15.00 6545.00
11.2 250mm Dia Sluice Valve No 4.00 18009.00
Providing and supplying ISI mark CI D/F Reflux
Valves as per IS:5312 (Latest Edition) of
following class and diameter including all taxes,
insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to departmental stores, stacking
etc. complete. Reflux valves PN 1.6 IS
with ISI mark. 100mm Dia. No 5.00 5563.00
Excavation for pipe line trenches for water
supply, sewerage line, manhole etc. all with
shoring and struting if required as per required
gradient and line including safety provisions
13.0 using site rails and stacking excavated stuff
including up to all required lead cleaning the site
etc. complete for all lifts and strata as specified.
In all sort of soil and soft murrum. Upto 1.50 Mt.
Depth. Cmt. 917.00 102.35
13.1 For CC 1:2:4 or Asphalt Road Cmt. 30.00 427.80
Lowering, laying and jointing C. I. S & S Spun
pipes suitable for Tyton joints / Mortar lined D.I.
Pipes of various classes with CI / MS specials of
14.0 following diameters in proper position, grade
and alignment as directed by Engineer-in-charge
including hydraulic testing etc. comp. For
14.1 For 150mm Dia Pipe Rmt. 320.00 87.40
DESCRIPTION UNIT QTY RATE AMOUNT
14.2 For 250mm Dia Pipe Rmt. 100.00 146.05
Lowering, laying and jointing G. I. pipes with G.I.
specials of following diameters in proper
position, grade and alignment as directed by
Engineer-in-charge including conveyance from
stores to site of work, labour, giving hydraulic
testing, etc. comple. 50mm Dia Rmt. 25.00 20.70
Lowering, laying, fixing and jointing
PVC/uPVC/cPVC pipes and specials of
following class and diameter including cost of
16.0 conveyance from stores to site of works
including cost of labour, material, cement
solvent, giving satisfactory hydraulic testing as
per ISI code. For 110mm Dia PVC Pipes. Rmt. 100.00 21.85
16.1 For 160mm Dia PVC Pipes Rmt. 50.00 32.20
Lowering, laying and jointing in position
following C. I. / D/F Reflux valves, Butterfly
valves, Sluice valves and Air valves including
17.0 cost of all labour, jointing material, including nut
bolts and giving satisfactory hydraulic testing,
etc. complete. 100mm Dia. No 32.00 504.85
Providing and casting in situ C.C. in grade M-20
(proportions as per mix design or as per table
of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm
to 20 mm for RCC work, including scaffolding
centering, formwork, needle vibrated
18.0 consolidation, curing complete up to 6 meter
depth or height (excluding cost of reinforcement
and neat finishing) with centering and
shuttering/deshuttering etc. complete for
structure other than water retaining (Below G.L)
For Thrust Block.
Providing and cast in situ C.C. in grade M-25
proportions of ingredients as per mix design by
weigh batching using granite, quartzite trap
metal of size 12 mm to 20 mm and or 6 mm to
12 mm including scaffolding centering formwork,
19.0 needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of
reinforcement) with centering and
shuttering/deshuttering etc. comp. up to 6 meter
height /depth Av. G.L.for all water retaining
structures. Cmt. 20.00 7710.75
Refilling the pipeline trenches incl. ramming,
20.0 watering, consolidating desposal of surplus stuff
as directed within a radius of 3 km. Cmt. 779.00 25.30
DESCRIPTION UNIT QTY RATE AMOUNT
Supplying cutting, bending, binding and placing
in position steel as per plan and design and as
per ISS 2502 including cost of steel and binding
wire for reserviors/structures only including lift
up to 6 meter height or depth below G.L. for all
diameters. Do-Thermo mechanically Treated
(TMT) bars Fe-500 grade for all diameters.
Labour charges for Jointing on CI/DI pipeline/
Valves of following diameter at different places
including necessary excavation manually or by
machinery, removing of mud, dewatering,
cleaning of pipe, cutting of pipe, Jointing &
repairing using CID joints including CID joints,
rubber rings, nut bolts, hiring excavator, Hydra/
Crane, dewatering machine, fuel, operator etc
complete (including cost of jointing material but
excluding cost of pipe). For 100mm Dia Pipe or
22.1 For 150mm Dia Pipe or Valve No 27.00 2870.40
22.2 For 250mm Dia Pipe or Valve No 8.00 5315.30
Labour charges for Jointing in PVC pipeline of
folling dia meter at different places including
necessary excavation manually or by mechanise
excavation, dewatering removing of mud,
cleaning of pipe and leakage portion, cutting the
pipeline & removing piece of pipe from trench
with inclussive of mechanical devices JCB,
Hydra/Crain if necessary & labours required with
providing material such couplers, solution etc.
comp. (incl. all material but Exclu. cost of pipe)
For 110mm Dia Pipe.
23.1 For 150mm Dia Pipe No 12.00 1873.35
Supply and installation of MS fabricated
structure cabin @ site of work using 65 mm,
mm & 25 mm square pipes with cabin size
mtr x 1.5 mtr X 2.13 mtr including providing &
fitting of (1) backalite sheet 3.5 mm thick in
sides, (2) 20 guage MS sheet outer side for side
walls, (3) backalite sheet 3.5 mm thick sheet for
roof side, (4) 24 guage GI sheet out side with
mm plywood sandwitch fitting & flooring with
24.0 mm water proof plywood sheet and (5) shock
proof rubber mating. Job includes oil painting
two coats, door locking handle arrangement,
providing proper air ventilation and fuse box.
The meter & fuse box should be fitted on timber
hold fast for holding screw or nut bolts by semi
skilled labour as per detailed technical
specifications, drawings and instructions of the
Engineer-in-charge.
DESCRIPTION UNIT QTY RATE AMOUNT
Preparing structural design of RCC Under
Ground / Partially under ground / above high
ground level Reservoir of required capacity as
per relevant I.S. standards and constructing the
same, including excavation in all types of soil
strata (including rock) including shoring strutting
if required, for loose soil / to protect from
collapse, casting 100 mm thick P.C.C. levelling
course in M-15, Refilling the pit with proper soil
and disposing of the surplus stuff at all lead.
Including cement plaster in CM 1:2 with
approved water proofing compound to all over
inside container (i.e. walls, base, top slab/dome
bottom etc. all). Including all types of labour and
material charges of lowering, laying, erecting /
hosting and jointing of pipe assembly to inlet,
outlet overflow, washout and bye pass
arrangement as per hydraulic design.
Providing and fixing accessories, CI Manhole
frame and cover, water level indicator, adequate
cowl type ventilators or lantern type ventilator
with stainless steel jail. RCC chambers for
valves. Providing and applying three coats of
cement paint / snowcem to the out side face of
structure. It also includes satisfactory water
tightness test as per relevant I.S. code and
painting name of scheme and capacity on the
tank as per direction of engineer in charge.
B.B. Masonry Chambers for Valves. Providing
and applying three coats of cement paint /
snowcem to the out side face of structure. It also
includes satisfactory water tightness test as per
relevant I.S. code and painting name of scheme
and capacity on the tank as per direction of
engineer in charge.
List of Indian Standards for Design of GSR /
The structural design of GSR shall be in
accordance with provisions relevant I.S
(1) I.S. 3370 part I & II 2009 or Its latest revision
(1.1) I.S. 3370 part III & IV 1965 or Its latest
(2) I.S. 456 – 2000 or Its latest revision.
(3) I.S. 1893 – 2000 – 1984 or Its latest revision.
(4) I.S. 875, Part – 1 to 3, 1987 or Its latest
General Specifications:-
DESCRIPTION UNIT QTY RATE AMOUNT
(1) Water depth in container shall be adopted as
per data of tender. Capacity shall be calculated
excluding free board of the reservoir. If water
depth is not specified, the suitable water depth /
acceptable to field engineer in accordance with
hydraulic requirement (2) Shape of schoanltl
abine eard (oinp tpeladn f)o rs pceacpiaficeidty
.by in data shall be adopted in absence circular
shape shall be adopted.
(3) Size shall be fixed as per availability of
space (land area) at site / acceptable engineer
(4) Effect of overlapping of pressure bulbs on
soil due near by structure and proposed sump
should be considered.
(5) Care shall be taken that no damage should
occur to nearby existing structure.
Compensation shall be paid for the same by
(6) The minimum concrete grade for RCC shall
(7) HYSD Fe 415 / 500 grade reinforcing bars
confirming to I.S. 1786 / 1139 shall be
25.0 considered in design. CRS / TMT bars shall be
provided. In saline atmosphere corrosion
resistance stainless steel / HCR rebar shall be
provided. Any other steel can be used with
approval of C.E./ in situation of non availability in
market without extra cost.
(8) Minimum size (or thickness) of various
components shall be provided as per tender
criteria / specifications in absence as per I.S./
Std. practice of G.W.S.S.B. Minimum
dimensions specified for various components in
tender data / specifications shall be provided
(9) The safe bearing capacity (SBC) shall be
referred from SBC test report. In absence of
report it shall be referred from data sheet. If poor
soil is found / water table is met with during
excavation SBC shall be scientifically
ascertained and design shall be revise. No extra
shall be paid for increase in quantity.
(10) DI pipes and special shall only be used if
type is not specified in tender.
(11) The rate shall include cost of dewatering
during excavation making all arrangement when
water table meets within depth.
(12) The structure shall be designed properly to
resist uplift due to ground water table specified
in data or actual ground water table meets with
during excavation. If GWT / Uplift is mentioned
in tender and during excavation it dose not meet
7.5% rate shall be reduced.
DESCRIPTION UNIT QTY RATE AMOUNT
(13) SS pipes railing shall be provided over
sump perifery when sump height is ≥ 1.5 meter
above ground level.
(14.a) RCC staircase/RCC Steps should be
provided from GL to sump top slab based on the
height of the GSR above/below the ground.
(14.b) RCC Staircase with SS railing to be
provided inside reservoir container. BB Masonry
staircabin to be provided to cover the same with
MS safety door having locking arrangement.
(15) Appearance of structure should be
aesthetically good looking acceptable to
(16) Any change in size, shape, depth below GL,
height above GL, water depth, F.B., size of
member etc can be permitted in exceptional
case due to site condition or hydraulic design
requirement by C.E. No extra shall be paid for
(17) Any change in data, dimensions, shape,
water depth, reduction in size if permitted by
competent authority and if it reduces quantity
then payment shall be reduced prorate.
(18) When capacity of GSR / Sump is > 20 lakh
litres two or suitable compartments acceptable
to executive engineer shall be designed and
(19) Agency shall engage qualified (at least
graduate) consulting engineer for designing the
structure and he / she shall visit the site for
guidance of work.
(20) 75% part rate shall be payable for concrete,
reinforcement and plastering items of container
until satisfactory hydraulic testing for water
tightness is performed as per tender condition.
Till the work shall be treated as incomplete.
Above conditions / general specifications Sr. No.
1 to 20 are part and parcel of tender (contact)
and prevail over other provisions in tender.
As above with water table (Sub soil water
level below foundation).
Cost of 6.0 Lac.Liter Capaity. No 1.00 2257589.00
DESCRIPTION UNIT QTY RATE AMOUNT
Supply & Installation of Sintex SMC (GRP)
Panel Tank. Capacity 0.48 LL, Size 4.0 x 4.0 x
3.0 Mtr. Having Manhole Panel Assembly with
lockable Lid dia. 600mm, 50mm Dia PVC Air
Vent (1 No), FRP internal & External Ladder,
Inlet 50mm (2 No), Outlet 100mm Dia (2 No) etc.
26.0 Including Accessories like PVC Gasket/ Air vent,
Hot dip Galvanized Nuts & Bolts, PVC Roof
Support Pipe, External Support / External Top
Tie Rod required if height more than 1.0 mtr.,
FRP Pultrured / PVC pipes Internal Support.
etc. Complete. As Directed By Engineer In
Charge. KL 48.00 21000.00
Providing and supplying D. I. K-7 grade pipes for
following nominal bore diameter with internal
cement mortar lining including all taxes,
insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to departmental stores, stacking
etc. complete. (IS 8329-2000). 150mm Dia
Pipes. Rmt. 40.00 1477.00
Providing and fixing M.S. grills of required
pattern to wooden frames of windows etc. with
M.S. flats at required spacings and frame
alround, square or round bars with round
headed bolts and nuts or by screws (A) Plain
Providing and fixing 50 cm wide M.S. Ladder
fabricated from M.S. Flats 10 mm x 75 mm with
20 mm dia steel bar steps in double rows, @
29.0 cm C/C. The include stays of 10 mm x 50 mm
flats fixed at 3 meter C/C with welding anchoring
and 3 coats anticorrosive paint.
29.1 Safety Cage for MS Ladder Kg. 575.00 77.05
Gunniting the exterior surface in CM 1:2 having
thickness of 40 mm to 50 mm (Ave.) for beam,
braces, column and container slab incl.
chiselling and scraping loose concrete cleaning
the surface with water and air under pressure
and including providing and fixing in position
steel wires square mesh 75 mm x 75 mm as per
IS: 1966-1982 3.15 mm Wt/Sq. Mt. 1.64 Kg. with
spot welding wherever necessary with main
reinforcement incl. tying binding with wire incl.
scaffolding centering staging all equipment and
materials etc. complete incl. labour and testing
of the container.
DESCRIPTION UNIT QTY RATE AMOUNT
Providing the gunniting to interior surface of
cement / masonry / Water Tank of various
capacities as specified at various places with
cement mortar (1:2) in thickness of 40 mm
including chiselling and scraping loose concrete
and plaster incl. providing and fixing in position
mm dia. mild steel bars reinforcement at 15 cm
c/c both ways including fabricating and cost of
binding wires including centering, staging all
equipments etc. complete including scaffolding,
carting of all type of material and equipments to
site of work and giving hydraulic testing up to
satisfaction of engineer in – charge. --do-- for
Columns, braces and Shaft staging above 6m
Providing pressure grouting at 5.6 Kg/Sq.cm in
required row/zigzag fashion as specified at
m interval as per site conditions to stop
leakages from water retaining structures
32.0 including supply of cement and hardening
chemical, bringing equipments like compressor
and all scaffolding works to get smooth finishing
as directed by engineer in charge. To
Concrete/R.C.C Structure. Bag. 91.00 612.99
Drilling 40 mm Dia. Holes in masonry/concrete
structures with providing and fixing 500 mm long
GI Pipeline for pressure grouting including
supply of material, machineries and labour cost
Labour charges for cleaning of sump / GL
cistern including cleaning and removing algae,
calcinations, sludge, dirt deposition from bottom
and as well as from wall of container,
disinfection by bleaching powder with all
necessary tools and plants, labours and cost of
disinfectant etc complete. --do-- for 9.0 Lakhs
Liter Capacity. No 1.00 9684.15
34.1 --do-- for 1.25 Lakhs Liter Capacity. No 1.00 2617.40
Labour charges for cleaning of RCC ESR
including cleaning and removing algae,
calcinations, sludge, dirt deposition from bottom
and as well as from wall of container,
disinfection by bleaching powder with all
necessary scafolding, tools and plants, labours
and cost of disinfectant etc complete --do-- for
2.0 Lakhs Liter Capacity. No 1.00 3140.65
Cement plaster 20 mm thick in C.M. 1:2 using
36.0 water proofing compound of approved quality
including finishing etc. complete. Smt. 411.00 222.20
Applying any approve quality of cement paint in
37.0 three coats including cleaning washing etc.
complete. Smt. 2055.00 90.85
DESCRIPTION UNIT QTY RATE AMOUNT
Applying Anti corrosive Chemical treatment
Food Grade for Exposed Surfaces of M.S.
Structures / Pipe Grade for Exposed Surfaces of
38.0 M.S. Structures / Pipe and smooth and applying
treatment in two coats and smooth and applying
treatment in two coats.
Providing and fixing water level indicator or
depth gauge painted on TW plank 25mm/ MS
plate 4mm thick float, level indicator sliding wire
on standard pullies incl. necessary arrangement
to prevent the swinging etc. complete with
calibration uo to 5 mt height. No 4.00 6348.00
Finishing wall with water proofing cement paint
of on wall surfaces (Two coats) to give an
approved brand and manufacture and of
required shape even shade after thoroughly
brushing the surface to remove all dirt and
remains of loose powered materials. Smt. 2684.00 100.00
Supply & fixing factory finished cold formed
Light guage steel frame sections confirming to
SP:6 (5) 1980 at site or work including riveted,
bolted or welded in builtup for all type of
41.0 sections, in framed work, cutting, hoisting, fixing
in position and applying primer coat of approved
steel primer etc. complete as per structural
designs & directions of Engineer-in-charge.
Providing an fixing 25 mm x 5.2 mm MS railing
with three horizontal rows and posts of angle
iron of size 65 mm x 65 mm x 8 mm RCC
mm and 1.15 meter height and placed at 1.85 mt
/ c/c including painting two coats and anchorage
in CC etc. complete. Kg. 2151.00 88.55
Providing fusion bonded Epoxy coating not less
than 175 micron thickness and up to 300 micron
to reinforcement bars as per IS-13620-1993/
ASTM-775 M including testing of coating at plant
and all taxes (A) 10mm to 16mm dia bar.
Providing fusion bonded Epoxy coating not less
than 175 micron thickness and up to 300 micron
to reinforcement bars as per IS-13620-1993/
ASTM-775 M including testing of coating at plant
and all taxes (B) 20mm to 32 mm dia bar.
DESCRIPTION UNIT QTY RATE AMOUNT
Application of polymer modified mortar to the
damaged structure: Chip off loose weak
unsound concrete from the damaged structural
member upto the depth of sound concrete,
removal of corrosion scales on corroded
reinforcement after removal of corrosion scales
all exposed cone. surface shall be cleared.
Apply alkaline based rust converter in two coats
with a time interval between two coats, then
apply two coats of IPN coating to the exposed
corroded bars, apply CI (corrosion inhabitor) by
brush/ spray over the concrete (avoid coating on
steel). After spraying of inhibitor, bond coat of
epoxy-latex based polymer shall be brush
applied to the concrete as well as steel surface,
the subsequent 15 to 40 mm thick application of
polymer modified mortar must be applied before
the bonding coat is hardset. (the detail /
instructions of the methodology of work).
Demolition including stacking of serviceable
46.0 materilas and disposal of unserviceable
materials with all lead and lift. (i) R.C.C. work Cmt. 5.00 1056.58
Demolition of Brick work and stone masonry
including stacking of serviceable materilas and
disposal of unserviceable materials with all lead
and lift. (ii) In Cement Mortar. Cmt. 24.50 549.49
Dismentaling tiled of stone floors laid in mortar
including stacking of serviceable materilas and
disposal of unserviceable materials with all lead
and lift. Smt. 221.50 47.94
Dismentling steel work including distempering
49.0 and stacking the materials with all lead and lift.
For Rolling Shutters. Kgs. 300.00 3.76
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
architraves, holdfasts and other attachment etc.
complete and stacking them within all lead and
lift. (i) Not exceeding 3 Sq.M. in area.
Scraping oil paint from steel and other metal
51.0 surface and making the surface even (with Hand
Scraping.) Smt. 9.00 187.52
Removing dry or oil bound distemper by a
washing and scraping and sand papering the
wall surface smooth including necessary repairs
to scratches complete. Smt. 501.00 11.26
Excavation for Foundation upto 1.5 m. Depth
including sorting out and stacking of useful
materials and disposing of excavated stuff upto
50 Meter lead (A) (loose or soft soil) Cmt. 276.00 120.01
Excavation for Foundation from depth 1.5 m. to
3.0 m. including sorting out and stacking of
54.0 useful materials and disposing of excavated
stuff upto 50 Meter lead (A) (loose or soft soil).
For column. Cmt. 18.50 133.05
DESCRIPTION UNIT QTY RATE AMOUNT
Filling available excavated earth (excluding
Rock) in trenches. Plinth, sides of foundations
55.0 etc. in layers not exceeding 20cm. In depth
consolidating each disposited layer by ramming
and watering. Cmt. 258.00 133.65
Filling in foundation and plinth with murrum or
selected soil in layers of 20cm thickness
including watering, ramming and consolidating
etc. complete. Cmt. 119.50 296.29
Carring out plinth treatment to post construction
/ existing structure by spraying chemical solution
for termite control treatment including labour and
material consistment with I.S.I specification.
Using Chlordene and Chiorpurfiles 20 EC. As
Per 6131_paret-II Consentration Weight one
57.0 percent is recommended i.e one litre 20 EC
chemical emulsion with 19 liter give 1 %
concrentration inclusive of one litre chemical
emulsion appication at the rate of 5 Litre
chemical / Sqm of surface is recommended as
Providing and laying cement concrete 1:3:6 (1
Cement, 3 coarse sand, 6 crushed stone
58.0 aggregates 20mm nominal size) and curing
complete excluding cost of formwork in
Foundation and Plinth. Do For PCC. Cmt. 101.50 3080.90
Providing and laying controlled cement concrete
M-200 and curing complete including the cost of
59.0 formwork but Excluding the cost of
reinforcement for reinforced concrete work in
Mass Concrete/Flooring. Cmt. 7.00 4464.20
Providing and laying controlled cement concrete
M-250 and curing complete including the cost of
formwork and excluding the cost of
reinforcement of reinforced concrete work in --
do -- for R.C.C. Column Footing.
60.1 -- do -- for R.C.C. Column Up to G.L Cmt. 3.00 6338.76
60.2 -- do -- for Ground Beam Cmt. 9.50 5875.17
60.3 -- do -- for Grade Slab Cmt. 8.50 4525.81
60.4 -- do -- for R.C.C. Column Above G.L Cmt. 9.00 6497.33
60.5 -- do -- for Coping Cmt. 3.00 5148.98
60.6 -- do -- for R.C.C. Lintel Cmt. 3.75 7633.58
60.7 -- do -- for Chhajja Cmt. 1.50 7633.58
60.8 -- do -- for R.C.C. Beam Cmt. 14.50 5763.06
Providing ISI Mark TMT Bar Fe-500
Reinforcment for R.C.C work including bending,
binding and placing in position etc. complete for
all Floors. Kg. 12125.00 77.29
Providing and Laying brick work using common
burnt clay building bricks (Conventional) having
crushing strength not less than 35 Kg./Sq.Cm in
foundation and plinth in Cement Mortar. (1:6) (1
Cement : 6 fine sand) - (A) Conventional.
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and Laying brick work using common
burnt clay building bricks (Conventional) having
crushing strength not less than 35 Kg./Sq.Cm in
foundation and plinth in Cement Mortar. (1:6) (1
Cement : 6 fine sand) - (A) Conventional.
Providing and fixing 35 mm thick shutters for
Doors, windows and clerestory windows
including Indian teak wood frames 10 cm x
64.0 cm. size including anodized alluminium fixtures
and fastenings including primer coat of
approved quality and two coats of oil painting
etc, complete. (ii) Fully Panelled. Smt. 14.50 5338.30
Provoding and fixing 35 mm thick flush door
shutters, solid core construction with frame of
first class hardwood with cross board and face
veneer or plywood face panels, including
65.0 anodised alluminium butt hinges with necessary
screws. (B) Non-decorative type and block
board using bright finished M.S. piano hinges of
(A) Nickel plated piano hinges.
Providing and fixing window having extruded
aluminum Colour Powder Coated section frame
main outer size 63.50 x 38.10 x 1.95 mm, @ Wt
1.094 Kg / Rmt, horizontal two track member
size 61.85 mm x 31.75 mm x 1.20mm @ wt.of
0.695 Kg/mt, vertical member of size 61.85 mm
with sliding shutters of horizontal member size
vertical member of size 40mm x 18mm x
1.29mm @ wt.of 0.456Kg/mt with 5 mm thick
transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing to
frame as per details etc complete. for window.
Providing and fixing glazed louvered glass
windows and ventilators with teak wood frame
10cm. x 7cm. Size including 3 coats of oil
painting to wood work etc. complete. Rmt. 2.00 4202.12
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S. laths inter-
locked together through their entire length and
jointed together at the ends by end locks
mounted on specially designed pipe shaft with
68.0 bracket plates, guide channels and arragements
for inside and outside locking with push-pull
operation including the cost of hood cover and
spring etc. complete. (A) Shutters having width
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and fixing Fly proof galvanised M.S.
wire gauge of I.S.l gauge designation 85 G. with
69.0 wire of dia. 0.56 mm to windows and celevating
windows including 60 x 20mm beading of teak
wood. Smt. 36.00 685.91
Applying Priming Coat on new steel and other
metal surface by throughly cleaning, oil, grease
and scoured with brushes fine steel wood,
scrapers and sand paper with ready mixed
70.0 priming paint brushing red lead and Painting two
coats with synthetic enamel paint, brushing to
give an even shade including cleaning the
surface of all dirt, dust and other foreign matter.
Providing 15mm thick cement plaster in single
coat on brick/concrete wall for interior plastering
and finished even and smooth in cement mortar
1:4 (1 cement : 4 sand) and finishing with a
floating coat of neat cement slurry upto floor two
level. Smt. 282.00 220.61
Providing 10mm thick cement plaster in single
coat on ceilings and soffits of stairs for interior
plastering and finished even and smooth in.
Cement Mortar 1:4 ( 1 Cement : 4 Sand) and
finishing with a floating coat of neat cement
slurry for all floors. Smt. 202.50 203.97
20mm thick sand faced cement plaster on walls
upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M.
1:3 (1-cement : 3-sand) and 8mm thick finishing
coat of C.M. 1:1 (1-cement : 1-sand) etc.
complete. Smt. 655.50 337.52
Applying two coats of putty & two coats of
primer of approved brand and manufacture on
new wall surface to give an even shade
including thoroughly brushing the surface free
from mortar dropping and other foreign matter
and sand papered smooth. Smt. 832.00 40.59
Distempering (Three Coat) with oil bound
washable distemper of approved brand and
manufacture and of required shade on wall
surfaces to give and even shade over and
75.0 including a primer coat with alkali resistance
primer of approved brand after throughly
brushing the surface free from other foreign
matter and also including preparing the surface
even and sand papered smooth. Smt. 567.00 101.75
Distempering (Three Coat) with oil bound
washable distemper of approved brand and
manufacture and of required shade on Ceiling &
Sloping Roof surfaces to give and even shade
over and including a primer coat with alkali
resistance primer of approved brand after
throughly brushing the surface to give and free
from other foreign matter and also including
preparing the surface even and sand papered
smooth. Smt. 284.00 113.17
DESCRIPTION UNIT QTY RATE AMOUNT
Finishing wall with Weather Proof Acrylic
Exterior Emulsion Paint on wall surface (two
coats) to give and required shape even shade
77.0 and of approved brand and manufacturer after
throughly brushing the surface to remove all
dirts, and remians of loose powdered materials
etc. complete. Smt. 1323.50 117.40
Providing and laying polished Kota stone slab
flooring over 20mm (Average) thick base of
cement mortar 1:6 (1 - cement : 6 - coarse sand)
laid over and jointed with grey cement slurry
including rubbing and polishing etc. complete.
(B) 30 mm thick Smt 200.00 1069.62
Providing and laying polished Kota stone slab
flooring over 20mm (Average) thick base of
cement mortar 1:6 (1-cement : 6-coarse sand)
79.0 laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
(A) 25mm thick Smt 82.50 1001.14
Providing and laying polished kota stone slab
25mm thick in risers of steps, skirting Dedo and
pillars laid on 10mm thick cement mortar 1:3 (1-
80.0 Cement : 3 coarse sand) and jointed with gray
cement slury mixed with pigment to match the
shade of slab including rubbing and polishing
etc. complete. Smt 36.50 1149.52
P & L 24" x 24" vitrified 8 mm thick tile flooring
over 20 mm (average) base of cement mortar
1:6 ( 1 cement: 6 coarse sand) on new surface
or fixing on existing flooring by adhesive
81.0 material including dismentaling of existing
flooring and jointed with color cement slurry
including finised with flush pointing & cleaning
the surface etc. complete for antiskit.
Providing and laying white glazed tiles 6mm
thick in skrting risers of steps and dedo on
82.0 10mm thick cement plaster 1:3 (1-cement : 3-
coarse sand) and jointed with white cement
slurry. Smt 71.50 970.17
Providing and laying polished Granite tiles
mm thick in risers of steps, skirting Dedo and
pillars laid on 10 mm thick cement mortar 1 :
(1 cement : 3 course sand) and jointed with gray
cement slurry mixed with pigment to match the
shade of slab including rubbing, polishing,
Moulding etc. complete. For Flooring, Doors &
Windows Edges. Smt 32.50 1631.15
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
84.0 tempered to bring mortar creme out upto surface
using white cement including rounding off
junctions and extending them upto 15 cm along
the wall, clearing with water and oxalic acid etc.
as directed. Smt 198.50 765.97
Providing and laying cement concrete flooring
1:2:4 (1- cement : 2-coarse sand : 4-graded
85.0 stone aggregate 20mm nominal size) laid in one
layer and finished with a floating coat of neat
cement. (B) 50mm thick. Smt 50.00 339.14
Providing and supplying in standard length ISI
mark rigid unplasticised PVC pipes suitable for
potable water with ring fit joint including cost of
rings, as per IS Specification no. 4985/1988
including all local and central taxes,
transportation, freight charges, octroi, inspection
charges, loading, unloading, conveyance to the
departmental stores and including cost of
jointing material etc. complete.
Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in
below type of pipe erected with 6A Modular type
switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/ Wooden box, single mounting base
frame covered with textured/ metallic/ white
front plate modules erected on / in wall / ceiling
as per pipe erected, with necessary Lamp
holder/ ceiling rose / H.D. Connector as
directed. (a) with medium class Rigid PVC pipe
and accessories erected flushed on wall/ceiling
Point wiring for Tissino / Modular secondary light
point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper
wires, in below type of pipe to be erected
complete with earth continuity and necessary
connection with primary light with accessories
erected on Metal / PVC / wooden box covered
88.0 with 3 mm thick PC(Polycarbonate) / Acrylic
sheet for open / concealed wiring. with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed. Note:- Maximum up
to 6 mtrs length, excess will be considered as
Mains for Secondary Point. (f) with medium
class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete
DESCRIPTION UNIT QTY RATE AMOUNT
Point wiring for FAN with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in
below type of pipe erected with 6A Modular
type switch and hum free EME step type
electronic fan regulator mounted and
accessories with earth continuity of following
89.0 type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as
directed. (f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete
Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type
of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate
90.0 front plate modules erected on / in wall / ceiling
as per pipe erected with following type of
accessories. [I] For 6A Plug and 6 a switch with
2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board (f) with medium class
Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete.
[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board. (f) with
91.0 medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat.
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
92.0 base frame covered with textured / metallic/
white front plate modules erected on / in wall /
ceiling with following type accessories Cat. III
DESCRIPTION UNIT QTY RATE AMOUNT
Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq. mm
(green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires
erected in below type of pipe with 6A Modular
type switches and following type of accessories
erected on PVC / Metallic/ Wooden box, single
93.0 mounting base frame covered with textured /
metallic/ white front plate modules erected on /
in wall / ceiling as per pipe erected. with
necessary batten/ angle holder or ceiling rose or
H.D. Connector as directed. (f) with medium
class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete CAT. III
Providing following type of Modular Type
Accessories mounted with PVC / metallic
/Wooden box, single mounting base frame
covered with textured / metallic /white front
plate, modules erected with necessary
connections as per site situation directed by
Engineer In charge. (1) One No. SP 6 Amp.
Cat.III. Ea. 38.00 151.50
94.1 (2) One No 5 pin plug. Cat.III Ea. 23.00 151.50
94.2 (9) 16 Amp. SP one way switch. Cat.III Ea. 12.00 180.79
94.3 (10) 6/16Amp. Universal socket. Cat.III Ea. 12.00 199.98
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
95.0 necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b)
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe
to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A)
With medium class Rigid PVC pipe and
accessories. (a) 2 wire 1.5 sq. mm.
Supplying & erecting M.S. Box having 16 Gauge
painted with red oxide or Heavy duty PVC box
erected flushed on wall or concealed in wall with
necessary plastering & finishing as directed of
following size. (b) 175 mm x 100 mm x 75 mm(d)
DESCRIPTION UNIT QTY RATE AMOUNT
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge
dissipation suitable for following type of
applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test
certificate including value of earth resistance of
installation duly stamped and signed by agency
and officer Incharge has to ensure the value of
earthing resistane mentioned in test Certificate)
& having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017,
Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain
moisture for long time Necessary test report
must be submitted by Agency. (a) For Electrical
Installation up to 440V in normal soil. Length of
pipe - 1 Mtr. Back filling compound - 1 No Bag of
(b)For Electrical installation up to 11 KV in
Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of 25 Kg. Ea. 4.00 5760.03
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having
3blades with aluminium blades with, canopy &
30 cms. down rod erected with earthing. (Make
shall be approved by Engineer in charge)
Supplying and erecting 19 / 20 mm. nominal
bore Medium Class M.S. Pipe down rod erected
100.0 duly painted for fan complete with proper
insulation without leckage and earthing.
Supplying & erecting fan hook box of 10 mm
M.S. round bar bounded to the RCC bars up to
50mm length each side and pierced through a
16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with
necessary finishing. Ea. 12.00 108.07
Providing 2.5mm. thick laminated acrylic sheet
to cover the fan hook or Fan box. Ea 12.00 18.18
DESCRIPTION UNIT QTY RATE AMOUNT
Supplying & erecting approved make low noise
decorative exhaust fan having square frame
ABS body with inbuilt lowers & square frame.
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. &
corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more
than 0.95, THD < 15%, CCT 3000 K to 6500K,
104.0 Luminaire efficency> 85 lumens/ watt, LED LED
driver efficiency > 85 % (fitting required LM-79 &
LM-80 Certificates) (NOTE: Below description
have shown ranges of Wattage capacity of LED
fittings. The Engineer incharge may select any
wattage capacity between the ranges shown. (A)
Tube Light with integral driver. (v) 36-40 Watts,
Surge-2 KV, IP-20, conventional 4 feet.
Supplying and erecting led lamps with following
wattage capacity of 220 to 240 voltage,
minimum 15000 burning hours life, 500 V in built-
surge protection, Polycarbonate diffuser,
mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5. (A) LED Lamps integral type,
with PC diffuser suitable LAMP holder. (ii) 5 to
watts. Ea 14.00 112.11
Supplying and erecting LED street light / Flood
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name
engraved or embossed 160 to 270 V, Power
Factor more than 0.95, THD < 10 %, CCT
106.0 K to 5700K, Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %. (fittings required LM-79 & LM-
80 certificates) (NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings. The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV
integral and, Light must have 440VAC line
supply with over -voltage protection. above 36 to
106.1 (v) above 120 to 160 watts Ea 9.00 7875.98
DESCRIPTION UNIT QTY RATE AMOUNT
Providing and fixing wash down water closet
European type W.C. Pan with integral "P" or "S"
trap and PVC flushing cistern with a pair of
C.L.I. or Mild Steel Brackets, complete with
fittings such as lead value siphon, 15mm
nominal size brass ball value with polythene
float, C.P. Brass handle unions and couplings
for connections with inlet, outlet and over flow
107.0 pipes, 40 mm dia flush bend including cutting
holes in walls and making good the same
connecting the flush bend with cistern and
closet, Jet spray heavy duty with S.S. Braided
hose 60 cm long etc. comp. incl plastic sheet
cover including jointing trap with pipe in C.M. 1:1
( Cement : 1 fine sand) (a) Viterous China - (i) In
Providing and fixing gun metal chek or non
return fullway wheel valve. (A) 15 mm Dia. No 5.00 186.83
Providing and fixing Cast Iron (Spun nahni trap
of the 100mm. Inlet and 50mm. Dia outlet having
self cleaning design with C. I. Screwed down or
hinged grating and stainless steel jali at F.F.I.
Including cost of making cuts in walls slab floor
etc. and making them as per original testing etc.
complete as directed by Engineer-in-charge.
Providing and fixing S.W. gully trap with C.I.
grating brick masonry chamber and water tight
C.I. cover with frame of 300mm x300mm size
(inside) with standard weight. (i) Square
mouthtraps. (B) 150mm x 100mm size P or R
type No 5.00 1246.92
Providing and fixing Flat back washbasin
mm x 400 mm size in White Color with single
hole for pillar tape with C.I. or M.S. brackets
painted white including cutting holes and making
good the same but Including 15mm dia. pillar
tap, capstan head, screw down high pressure
with screws, shanks and back nuts, 15mm dia
brass screw down stop tap, 32mm CP Brass
Waste & M.I. Fisher Union for wash basin etc.
complete. No 5.00 2078.58
DESCRIPTION UNIT QTY RATE AMOUNT
Providing, laying and constructing brick masonry
chamber for underground C. I. Inspection
Chamber with Inside Dimension 600mm x
850mm x 450mm dedo for single pipe line with
bends having crushing strength not less than
35Kg./Cm2 on C. M. (1:5) (1 cement, 5 Sand) C.
I. Cover with frame (light duty) of 455mm x
610mm internal dimension total weight of cover
with frame to be not less than 38.00 Kgs. (Wt. of
112.0 Cover 23 Kgs. and wt. of Frame 15 Kgs.) with
R.C.C. top slab with 1:2:4 (1 cement, 2 Coarse
sand, 4 graded stone (Kapachi) ) foundation
concrete 1:5:10 (1 cement, 5 Coarse sand,
brick bats of 40mm nominal size) inside plaster
15mm. thick with C. M. 1:3 (1 cement, 3 Coarse
sand) finished smooth with a floating coat of
neat cement slurry on walls and bed concrete
including curing etc. complete as directed by
Engineer-in-charge.
Providing erecting and fixing double coated ISI
water tank of required capacity each with all
necessary fittings and connection etc. complete
on terrace. Lit. 1000.00 3.95
Providing and laying (To level or slopes) and
jointing with stiff mixture of cement mortar in
114.0 proportion 1 : 1 salt glazed stone ware pipes
including testing of pipes and joint complete. (B)
Providing, laying and jointing in true line and
level 25 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by Engineer
In Charge. Pipe shall be fixed on the wall with
the help of clamp at every two meter c/c. or shall
be concealed as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Providing, laying and jointing in true line and
level 15 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by Engineer
In Charge. Pipe shall be fixed on the wall with
the help of clamp at every two meter c/c. or shall
be concealed as directed including necessary
fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent,
including cost of all materials.
Drilling of 200 / 215 mm dia. bore well in over
burden rocky or loose collapsible / boulder strata
& lowering of 175 / 200 mm dia. UPVC / PVC /
ERW casing pipe above 12 meters and up to
meters depth by DTH rig etc. complete.
DESCRIPTION UNIT QTY RATE AMOUNT
Drilling of 250 mm dia. bore well in all strata
including dual over burden strata by
118.0 Combination DR / DTH rig including lowering
200 mm dia MS ERW pipes in bore hole as
suggested by Hydrologist. Rmt. 122.00 1258.00
Manufacture, supply and delivery of ISI marked
ERW MS pipes conforming to IS: 4270/2001
119.0 with latest amendment. Rates are exclusive of
GST. 200 mm dia. (Minimum 6.00 mm thick).
MS Specials with Fittings (Elbows, Nipple, Step
120.0 Nipple, Union, Plug, Tee, Coupling, Reducer).
Manufacture, supply & delivery of ISI marked
UPVC Casing pipe IS 12818 with latest
amendment. (Rates are exclusive of GST).
200.00 mm nominal dia. " CM " Type. Rmt. 122.00 1444.00
PVC Fittings (Elbows, Nipple, Step Nipple,
Union, Plug, Tee, Coupling, Reducer). LS 2.00 8808.40
Supplying of following size of HEAVY UPVC
123.0 column pipe with coupler and wire lock. For
100mm Dia Pipe. Rmt. 244.00 1119.00
Clamp made from M.S. Plate with 3 holes other
side with nuts & bolts of std. Make and suitable
size (d) 450 x 65 x 10 mm flat suitable to
100/125mm dia pipe. per pair 4.00 687.07
Supply of best quality of well sorted sevaliya
gravel of size 4mm to 6mm cmt 0.864 2029.00
Supply of following size of TOP & BOTTOM
accessories i.e. Adaptor set (CI) long, pump
guard set, starter pipe Rubber ring for
126.0 submersible pump & UPVC column pipe as
directed by Engineer - in - charge with
necessary plumbing as desired. 100 mm dia.
Geohydrological ground water investigation
including vehicle charges. No 4.00 3571.00
S.I.T.C. submersible pump set for bore of
mm. dia. or more having 3 phase motor capacity
about 25 H.P. and discharge capacity having.
128.0 Lifting and Lowering taken extra. (6 Stage)
to 800 L.P.M. discharge at the head 84 to
mtrs. suitable for 80 mm dia. delivery pipe.
S.I.T.C. submersible pump set for bore of
mm. dia. or more having 3 phase motor capacity
about 30 H.P. and discharge capacity having.
129.0 Lifting and Lowering taken extra. (D) ( 5 Stage )
1150 to 1400 L.P.M. discharge. at the head
to 85 mtrs. suitable for 100 mm dia. delivery
pipe. sets 2.00 75848.00
DESCRIPTION UNIT QTY RATE AMOUNT
Lowering of submersible motor pump set at the
depth of following, complete with required. No
and size of casing pipes erected by means of
proper chain pulley block & pipe wrenches after
checking of threads of each pipe with coupling
to take the load of the pump set and pipe
assembly filled up with water. Above 60 mtrs.
and Up to 120 mtrs. No 4.00 2568.43
Supplying and erecting approved make 3 phase
motor control panel (ATS) made from 16 G.
CRCA sheet duly painted with epoxy power
paint inside and outside with hinged doors and
locking arrangement, consisting, of suitable
switch of AC 23 duty with HRC fuses (Cat.III),
starting and running contactors, overload relay,
Automatic water level controller, Electronic timer
with master timer CT operated Ammeter with
131.0 selector switch, Voltmeter with selector switch,
phase indicating lamps, single phasing
preventer , water level guard, over load, start,
run and stop push buttons, air cooled auto
transformer with 60%, 70%, 80% tapping, Panel
to be erected on angle iron frame grouted on
wall as directed., contactors relays, timer etc.
shall be of L & T Siemens / Cutler Hammer
make. Suitable for 25 H.P..
Supplying and erecting approved make 3 phase
motor control panel (ATS) made from 16 G.
CRCA sheet duly painted with epoxy power
paint inside and outside with hinged doors and
locking arrangement, consisting, of suitable
switch of AC 23 duty with HRC fuses (Cat.III),
starting and running contactors, overload relay,
Automatic water level controller, Electronic timer
with master timer CT operated Ammeter with
132.0 selector switch, Voltmeter with selector switch,
phase indicating lamps, single phasing
preventer , water level guard, over load, start,
run and stop push buttons, air cooled auto
transformer with 60%, 70%, 80% tapping, Panel
to be erected on angle iron frame grouted on
wall as directed., contactors relays, timer etc.
shall be of L & T Siemens / Cutler Hammer
make. Suitable for 30 H.P..
Providing and erecting ISI marked PVC
insulated PVC Sheathed Flat flexible
Submersible copper cable approved make of
following Size. 1 R x 3 C x 16.0mm2. Mtr. 200.00 488.84
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp. Kg. 80.00 97.00
DESCRIPTION UNIT QTY RATE AMOUNT
Construction of chamber in brick or bela stone
masonry, locally available in C. M. 1:6.
Foundation concrete 150 mm thick in C. C. 1:4:8
of trap metal size 25 mm to 40 mm thick, inside
cement plaster in C. M. 1:3 and cement pointing
outside in C. M. 1:3 and top cover of precast
RCC slab 100 mm thick (with key hole in two
parts, each with handles or MS Bar etc.
complete as given size) Upto 1 Mt. depth from
G.L. to pipe invert level incl. complete civil works
but excl. cost of excavation and refilling, with
cast in situ RCC slab in one single piece with
fixing of CI-MH Frame and cover (excl. cost of
CI-MH Frame and cover) with 23 mm thick brick
masonry wall in C.M.1:6. With Precast Slab in
two parts 15 cm : Size of Chamber 0.90 x 0.90 x
Providing, supplying and delivery of CI Manhole
frame and cover incl. all taxes, loading,
unloading and carting upto departmental stores
etc. comp. Size 0.9 m. x 0.90 m. heavy duty -
ton capacity. All Type. CI Manhole Frame &
Cover. Kg. 200.00 58.00
Plywood designed with one side commercial and
other side teak finished 15mm. Thick Smt. 4.00 347.46
Box Cutting the road surface to proper slope
and camber for making a base for road work
139.0 including removing the excavated stuff and
depositing on the road side slope as directed
upto 50Mt. Lead. No 77.00 106.80
Providing and laying Controlled cement
concrete M 250 (1:1.5:3) and curing complete
excluding the cost of reinforcement for R.C.C
work in Road by Trimix method by providing and
Fixing 'C' channels of 75mm x 75mm as per
required level slope and thickness of concrete
road levelling of placed concrete with surface
140.0 vibrator finishing the surface with power floater
and trowel ligh brooming on the surface
including providing and filling expansion joint
having size 20mm x 20mm as per manufactures
specification and making construction joint 3mm
x 20mm by using concrete cutter machine etc.
complete as directed.
DESCRIPTION UNIT QTY RATE AMOUNT
Supply, installation, testing & commissioning of
Vertical Turbine pump motor set of specified
duty parameters & guaranteed efficiency of
following MOC with specified capacity vertical
solid shaft TEFC squirrel cage induction motor
(with minimum IE-3 efficiency class), working on
three phase AC supply with 50 Hz ± 3%, 415 V
± 10%, rated speed 1000 RPM along with
column and bowl assembly, discharge head,
base channel / RSJ etc. complete as per
relevant IS. M.O.C.: Impeller & Sealing Rings:
CF8M, Bowl & Suction Bell : Cast Steel WCB
Shaft with coupling: SS 410, Column Pipe: MS
ERW, Mechanical seal (above 30 kw), Base
Plate: MS, Line Bearing: Thordon, Suction
Strainer: S.S. - Polytechnic WW - 15 HP -
141.1 Ketki Baug WW - 15 HP - 11 KW Set 2.0 163658.00
141.2 Arts Faculty WW - 25 HP - 18.5 KW Set 2.0 275243.00
141.3 TKG Boys Hostel WW - 15 HP - 11 KW Set 2.0 163658.00
Providing & erecting open well horizontal mono
block pump set with cast iron body, complete for
three phase submersible motor having. [J] For
25 HP 3 phase open well horizontal mono block
pump set suitable for 1075 to 1850 LPM @ 36 to
60 MTR head suitable for 65 /80 mm dia
delivery pipe. Cat.II.
S.I.T.C. submersible pump set for bore of
mm. dia. or more having 3 phase motor capacity
about 25 H.P. and discharge capacity having .
143.0 Lifting and Lowering taken extra. (C) (6 Stage)
1000 to 800 L.P.M. discharge at the head 84 to
102 mtrs. suitable for 80 mm dia. delivery pipe.
Cat.III. Set 2.0 67344.00
S.I.T.C. submersible pump set for bore of
mm. dia. Or more having 3 phase motor capacity
about 20 H.P and discharge capacity having .
144.0 Lifting and Lowering taken extra.(B) (14 Stage)
650 to 550 LPM discharge at head 84 to
mtrs suitable for 65 mm dia. delivery pipe.
Cat.III. Set 2.0 60407.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BuildingSpecificationBooklet.pdf
All GR-merged (2).pdf
Tender notice No. 8.pdf
Form B -1 of T.No. 8-9.pdf
Schedule B 8-9.pdf
Special Terms and Conditions T.No. 8-9.pdf
Technical-Bid for 8-9 of 2026-27.pdf
Download all tender documents and submit your bid