Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.2 Cr+₹1.2 Cr (57.0%)Rejected-Finance | ₹3.2 Cr+₹1.2 Cr (57.0%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹3.5 Cr+₹1.5 Cr (70.6%)Rejected-Finance | ₹3.5 Cr+₹1.5 Cr (70.6%) | L3 | Rejected-Finance Higher than lowest tender |
Tender Value
₹2.2 Cr
Closing Date
1 Feb 2022, 6:00 pmClosed
CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
PROVN OF CENTRALISED AC PLANT FOR OPERATION THEATRE AND X RAY UNDER GE BARRACKPORE
2021_MES_486904_1
89037/E8
Open Tender
Civil Works
Item Rate
365 days
BARRACKPORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (I) (P) KOLKATA
Exempted
23 Feb 2022
8 Nov 2021
8 Feb 2022
8 Nov 2021
1 Feb 2022
18 Jan 2022
Amount
Dismantling of Asbestos Cement (corrugated, semi-corrugated etc) sheets, in roof coverings including ridges, hips, valley gutters etc complete all as specified and as directed.
M&L Pre-Painted Galvalume aluminum zinc coating aluminium corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/ cladding to wall fixed with requisite Nos of self tapping screws and washers complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Taking up or down steel tubing and connection 15mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing and connection 20mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing and connection 25mm bore including cleaning for refixing or removal to store complete all as specified and as directed.
M&L for 15 mm dia GI Tubes medium grade, galvanised, with all fitting and fixed complete to walls and ceilings concealed type or laid in floors complete all as specified and as directed. .
All as per item no- 07 here in before but 20 mm bore.
All as per item no- 07 here in before but 25 mm bore.
Refixing 15 mm bore old steel tubing and connections in new or old position (wall, ceiling, floors etc) complete all as specified and as directed.
Refixing 20 mm bore old steel tubing and connections in new or old position (wall, ceiling, floors etc) complete all as specified and as directed..
Refixing 25 mm bore old steel tubing and connections in new or old position (wall, ceiling, floors etc) complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern of 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets including flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and as directed.
S& Fixed in repair For Vitreous china squatting pan , 'orissa' pattern, size 580 X 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, antisyphonage pipe, etc including concrete complete with all fittings includig making good to floor all as specified and directed.
S&F PVC (SWR) 'P' trap 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) 'S' trap 110 mm bore complete all as specified and as directed.
S&F in repair For Bib tap fancy type, chromium plated CP 15mm dia of bore complete all as specified and as directed.
S&F for brass CP Grating doom 125 mm dia with waste hole fancy type complete all as specified and as directed.
S&F white coloured toilet paper holder, vitreous China, (box type) fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
S&F 32 mm bore Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm complete all as specified and as directed.
S&F Shelf of PTMT fixed with & including CP brass screws & wooden / plastic cleats (min. weight 300gms) as in repair complete all as specified and as directed.
S&F in repair 15 mm bore fancy type stop valves, cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified complete all as specified and as directed.
S & F in repair Angle Stop valve Chromium plated , screwed down, high pressure fancy type long shank and cup (concealed type) 15 mm bore and fixed,complete all as specified and as directed.
S&F for PVC connection 15mm dia 450mm long with 02 Nos brass check nuts with washer etc complete all as specified and as directed.
S&F for towel rack 600mm long of CP fixed with and including chromium plated brass screws and wooden/plastic cleats as in repair complete all as specified and as directed.
S & F in repairs corner glass shelf 300 mm long complete all as specified and as directed.
S & F in repair PVC (SWR) Floor trap plain including jointing with solvent cement and removing old trap 75 mm dia of outlet and making good complete all as specified and as directed.
S&F in repairs viterous china wash hand basin, white or colour flat back Pedestal type including all fittings size 630 mm x 450 mm including brackets with waste pipe, including cutting for and pinning in ends of brackets or erecting stand with making good, fancy type complete all as specified and as directed.
S&F for Pillar Taps, cast copper alloy, Fancy type, chromium plated screwed, down high pressure with or without lettered Hot or cold with long screwed shanks and flynuts, screwed for iron pipe 15 mm dia and fixed complete all as specified and as directed.
M&L 32 mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S& fixed in repair Chromium plated Towel rail 20 mm dia, D type 60 cm long between flanges of complete all as specified and as directed.
S&F Fixed in repair of viterious china wash down water closet pan (padestal pattern), superior fancy type white (excl fixing bolt, flushing cistern and flush type) incl connection to drain (or outgoing pipe) and to flushing pipe, anti shyphonage etc with seat cover complete all as specified and as directed.
Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 Mtr mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed.
Taking down of cement plaster incl hacking out of joints, hacking for key, scrubbing down with water etc in any position complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of concrete/wall surfaces finished even and fair without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and smooth mixed with water proofing compound complete all as specified jand as directed. Note :- Water Proofing compound will be measured and paid as supply only under BOQ item Nos 41
M&L for 10mm thick rendering in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over a coat of 1.5mm thick wall care putty complete all as specified and as directed.
M & L for Preparation of old Distempered surfaces of walls by washing, rubbing down and complete removal, stopping nail holes, filling the Holes and cracks with wall care putty etc and applying two coats of ol bound distemper including one coat of primer on plastered surfaces complete all as specified.
M&L preparation of new plastered surface and applying three coats of white wash on ceiling surfaces all as directed.
M & L for Preparation of new surfaces of steel any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of zine chrome primer complete all as specified and directed .
M&L two coats of cement base paint over a coat of alkali resistant priming paint incl preparation of new plastered surfaces complete all as specified and as directed.
M&L for preparation of old plastered surface of plastered and applying two coat of cement base paint complete all as specified and as directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing unserviceable tiles to the low lying areas of defence land and rubbish off the premises complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 450X300X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to `match over and including 10 mm thick rendering on fair faces of brick work in cement mortar (1:4) complete all as specified and as directed.
S&F for joint free light shade double charged Vitrified ceramic tiles 10 mm thick (square/rectangular) polished, light shade, area of each tile not exceeding 0.36 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed
S&F for joint free light shade double charged Vitrified ceramic tiles 10 mm thick (square/rectangular) polished, light shade, area of each tile not exceeding 0.36 sqm, as in skirting, steps etc in vertical surfaces as in backing coat, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed
S&F for Non skid joint free Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc, set jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed
Taking down 100 mm bore Asbestos cement pressure pipes any class, including disconnecting pipe and fittingscomplete / PVC pipe including fittings etc to facilitate dismmentling old serviceable fittings/pipe laid in trenches floors or fixed to walls all as directed including earth work and demolition of PCC/Brick work and making good to match with existing surfaces complete all as specified and as directed
All as per item no- 53 here in before but 80/75 mm bore.
S&F PVC 110 mm bore (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors or fixed to walls complete all as specified and as directed.
All as per item no- 55 here in before but 75 mm bore.
S&F PVC (SWR) bends any radius 75mm bore with access door complete all as specified and as directed.
All as per item No-57 above but 110mm bore.
S&F For PVC bend 110mm dia complete all as specified and as directed.
All as per item No-59 above but 75 mm bore.
S&F PVC (SWR) branch piece, single (Single Y) /(Double Y) equal or unequal 75 mm bore with access door complete all as specified and as directed.
S&F PVC (SWR) branch piece, single (Single Y) /(Double Y) equal or unequal 110 bore with access door complete all as specified and as directed.
S&F PVC (SWR) junction single (Single T ) equal or unequal 75mm bore with access door complete all as specified and as directed.
All as per item No-63 above but 110mm bore complete all as specified and as directed.
S&F for PVC (SWR) Vent cowl 110mm bore complete all as specified and as directed.
S&F for PVC (SWR) Vent cowl 75 mm bore complete all as specified and as directed.
Disconnecting existing tanks of capacity 500 and n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting as required reconnecting and re-fixing in position complete all as specified and as directed.
Taking down Chowkhats with shutter or frame wooden / PVC or Aluminum n.exc 1.5 sqm each and refixing in same opening complete all as specified and as directed.
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) and removing to store complete all as specified and as directed.
S&F fiber glass reinforced plastic(FRP) door frames of cross section 90x45mm having single rebate of 30mmx15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be provided at the bottom to steady the frame complete all as specified and as directed.
S&F 30mm thick Fibre glass reinforced plastic(FRP) flush door shutter in different plain and wooden finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all round, with suitable wooden blocks inside at reqd places for fixing of fittings and polyurethane foam (PUF) Polystyrene foam to be used as filler material throughout the hollow palel casted monolithically with testing parameters of FRP laminate confirming to table of IS: 14856 complete all as specified and as directed.
Taking down Chowkat with shutter exc 1.5 Sqm and n.exc 4 sq.m each and removal to or from stores complete all as specified and as directed.
Taking down shutter only. exc 1.00 Sqm and n.exc 2 sq.m each and removal to or from stores complete all as specified and as directed.
Cutting holes into or through brick walls built in cement mortar or stone walls built in lime or cement mortar to a depth of embedded portion exc half brick but n exc one brick for inserting hold fast etc and making good dismantled portioin with cement concerete 1:2:4 type B1 complete all as specified and as directed.
S&F for Bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required: hooks (stay) , heavy, for large gates: hook and pintle hinges: large hasp and staples: chains: hand made sliding bolts: clamps: hold fasts: wall ties: hook for hanging fans : plain angle cleats for securing purlins to wood trusses or rafters: knee piece inserts: two way and three way straps, plate washers and similiar small article confirming to Fe 290 Gde - E -165 complete all as specified and as directed.
S&F for Aluminum anodised barrel tower bolts of extruded section and fixed. 150 mm long complete all as specified and as directed.
S&F for Aluminum anodised barrel tower bolts of extruded section and fixed. 200 mm long complete all as specified and as directed.
S&F For 100 mm butt hinges medium weight cold rolled mild steel, and fixed complete all as specified and as directed.
S&F For 150 mm long aluminum handles, fabricated type, anodised complete all as specified and as directed.
S&F in repair for aluminium alloy anodised ,sliding door bolt 250 mm long with hasp staples (bolt type) and fixing clip of sheet , cast or extruded section and fixing bolt and sliding bolt of extruded sections or cast alluminium alloy and fixed complete all as specified and as directed.
S&F for Powder coated anodised aluminum frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc. complete all as specified and as directed.
S&F Powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised alumnium snap beading, screws etc. complete all as specified and as directed.
S&F Powder coated anodised aluminium, double leaf, window and ventilator shutters, aluminium section weighing 0.55 kg /m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified and as directed.
S&F 5 mm thick sheet glass, ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F 5 mm thick sheet glass, ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares exceeding 0.5 sqm in each pane complete all as specified and as directed.
M&L for 12 mm thick medium density fibre board, exterior grade, fixed with screws/ beading to aluminum frame work complete all as specified and as directed.
S&F For Double action floor spring Hydraucally regulated made up of minimum 1.25 mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
S&F for Door closer hydraucally regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg Aluminum (extruded section body) complete all as specified and as directed.
S & F 3mm thick figured glass, Pin head type and glazing with oil putty in squares n.exc 0.5 sq.m in each complete all as specified and as directed.
S&F for Floor Door stopper of aluminum alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm long complete all as specified and as directed.
M&L 45 mm thick for MED PCGI Hinge double door of Size 1500x2100mm SS-304 ball bearing hinge, D-handle, Vision glass (300x300mm), Door closer, Tower bolt, Drope seal, Dead lock both side key operated & filling honeycomb complete all as specified and as directed.
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Dismantling of wall and ceiling boards or insulation boards any thickness including cover fillets etc complete all as specified and as directed.
S&F 6mm thick plain calcium silicate tiles false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections consisting of main "T" runner with suitably spaced joints to get required length and of size 24 x 38 mm made from 0.30 mm thick (minimum) sheet, spaced at1200mm center to center and cross 'T' of size 24 x 25mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200 x 600 mm and secondary cross "T" of length 600mm and size 24 x 25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200 x 600 mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smokedetectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all as complete for all heights as per specifications, drawings and as directed . Make : Ramco Hilux/ Aerolite /Armstrong.
Demolition of cement concrete (unreinforcement) as in ground floors or paving n. exc 15cm thick below or above ground level complete all as specified and as directed.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded Aggregate) as in plinth potection or all as specified. Finished cement concrete surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for Cement concrete in surfaces channels and drains type C2 1:3:6 (using 40 mm graded stone aggregate) complete all as specified and as directed.
M&L Providing cement concrete type C1 1:3:6 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
M&L for 25 mm thick Cement Concrete type B-1, 1:2:4 (using 20 mm graded aggregate) as in floor/pavings etc complete all as specified and as directed.
M&L for 50 mm thick Cement Concrete type B-1, 1:2:4 (using 12.5 mm graded aggregate) as in Roof padding/levelling course with wpc @ 200 ml per 50 kg cement bag etc complete all as specified and as directed. Note: WPC will be measured and paid in seprate item under relevent item of sch 'A' all as specified and directed.
M&L for forming construction joint 30 mm deep x 10 mm wide filled with 1:3 bitumen and sand complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of pipe 150 mm bore complete all as specified and as directed.
S&F for 15 mm dia, Brass, CP, Basin mixture, for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed.
Supply only two way stainless steel automatic, elbow and foot pedal operated Surgical Scrub Sink of 1400 x 500x 900 mm (standard size) of weight approx 100-120 kgs along with provn of soap dispenser complete all as specified and as directed.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S&F in repair white vitreous china laboratory sink size 600 x 450x200mm with plugs, washers and wastes; including beding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each and wastes pipe; including bedding in cm mortor on dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and as directed
Dismantling water tanks, capacity exc 500 & nexc 1000 Ltr and removing to store complete all as specified and as directed.
S&F rotational moulded polythylene water storage tanks(1000 Ltr) (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 25 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
M&L for forming jambs, etc. to openings (to foregoing items) including cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work, complete in cement mortar 1:6 complete all as specified and as directed.
S&F Chromium plated towel ring screwed down fixing to walls with screws complete all as specified and as directed.
M&L for Providing, cement concrete Type B0 1:2:4 (12.5 mm graded aggregate) in hold fast block,lintels upto 1.5 m clear span, cills, steps: seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones bed plates, kerbs not provided for water trough and the like including weathering, slightly rounded for chamfered angles and throating,complete all as specified and as directed.
S & F Stainless steel Curtain Rod 25 mm dia with fixing brackets,stops, etc fancy type complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone ,concrete, or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
M&L sheet glass ordinery quality 4 mm thick and glazing with oil putty or wooden beads n.exc 0.50 sqm in each panes complete all as specified and as directed.
S & F in repair health faucet chrome plated with push bottom flexible steel pipe with PVC lining of 1 mtr long suitable for 15mm pipe fancy type complete all as specified and as directed.
S&F for Joist, channel, flat iron, angle or tee sections, fixed independently, without connecting plates, etc (cut to ordinary length i.e within 20 mm of the length indicated) of Fe -410-W (Gde-E-250) quality A complete all as specified and as directed.
Excavation in Post holes ( or similar holes ) in soft loose soil, each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
S&F Rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-w (Gde-E250) quality A complete all as specified and as directed.
Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed.
M & L for writing letters or figures (Block, Roman, italic or Indian) after cleaning the existing surfaces n.exc 30 cm heigh complete all as specified and as directed.
M&L Cutting out cracks to V-section cleaning out, wetting, grouting with cement & sand slurry 1:3 complete all as specified and as directed.
M&L for 18-20mm thick mirrror polished Granite slabs (of any colour) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and as directed.
Demolition of Reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (below or above ground floors) (Reinforcement cut as required to facilitate demolition) cement concrete complete all as specified and as directed.
Use and waste of form work to the soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exceeding 200 mm thick (Horizontal or slopping) and making flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (nominal mix) as in slabs type B-1 (1:2:4) using 20 mm graded stone aggregate supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L Mild steel TMT bars in reinforcement 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
All as per item No. 129, but 6 to 8 mm dia for stirrups.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F framed work such as grills, gratings,etc.with end of bars shouldered and/ or riveted, or forged into spikes; framed guard bars ; barred iron doors; ladders; framed work of water tanks and similiar work confirming to FE.290.gde-E-165 Steel bar as in frame work sutch as grill gratings and guard bars and similar works complete all as specified and as directed.
Preparation of new surfaces of steel any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking down old bitumnious felt including vegetation and old plastered roof surface roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc disposed off to a distance complete all as specified and as directed.
Supply and laying of APP based modified polymeric membrane minimum 3mm thick reinforced with polyester non woven fabric 160 gms per Sqm over primed and prepared surface with transverse lap. Longitudinal lap and end lap fullu torching the joints and providing protecting layer all as per maufacturer's instruction and all the materials shall be of approved make and application shll be done by authorized applicators according to maufacturer's instruction complete over one coat of alumunum paint and including 20mm thick screed bed in cement mortar (1:4) including water proofing compound @ 3% by weight of cement or as per manufacturer instruction and also applying one coat of cold bitumunous primer over dried up surface of concrete including cleaning surface complete all as per particular specification and as directed. (Note : (i) WPC shall be measured and paid separately. (ii) Water proofing treatment shall be done by the approved authorised application. (iii) Net Area of polymeric membrane shall be considered for payment purpose.)
S&F Prelaminated particle board 18 /19 mm thick interior grade laminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work as in cup board or drawer or pelmat box complete all as specified and as directed.
S&F Mortice lock Brass, verticle type, size 75 mm with 4 leavers fixed with shutter and chowkats complete all as specified and as directed.
S&F Aluminium handle cast type for cup boards 75 mm length complete all as specified and as directed.
S&F Continuous (Piano) hinges, mild steel bright finished or electrogalvanised, width of flaps( when open) 30 mm complete all as specified and as directed.
S&F Ball catches with 8mm dia steel ball, catches with 8mm dia steel ball and brass body and striking plate including in and fixed complete all as specified and as directed.
S&F Hasp and staple, aluminum anodised, safety type with hinge pin including bolt of hinge plateand fixed with screws 100 mm long complete all as specified and as directed.
S&F for Steel rolling Shutters, with ball bearing (Refer claue No 10.23.1(b) of SSR Part I 2009) , as specified including top cover anchouring rod , hasp and staple and one shop coat of primer , erected in position as indicated, complete:gear operated type with chain wheel and hand chain thickness of laths in mm 1.25 mm complete all as specified and as directed.
M&L for Machine cut Kota stone slab flooring 20-25 mm thick over 15mm thick (1:6) cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Dismantling timber scantling 40 sq cm and over in section unframed work, in any position complete all as specified and as directed.
M&L 2nd class hard wood in scantlings clean sawn in timber scantlings timber framed and fixed to complete all as specified and as directed.
M & L for complete removal of existing paint finish and applying two coats of Plastic emulsion paint over a coat of cement primer over a coat of 1.5mm thick wall care putty complete all as specified and as directed.
M&L preparation of old painted steel surface of any description over 10cm width or girth otherwise described and applying one coat of synthetic enamel complete all as specified and as directed.
Removing excavated material/debris exc 1.50Km but n.exc 5 Km and depositing where directed complete all as specified.d.
M&L for cement concrete in foundations, filling and mass concrete type C2 1:3:6 (using 40 mm graded stone aggregate) complete all as specified and as directed.
Surface excavation n'exc 30cm deep and averaging 15cm deep and getting out soft/loose soil.
M&L hardcore of guage exc 63mm but n.exc 100mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
Supply and spreading of sand 50 mm thick as cushioning complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 grade with gray cement and no pigment complete all as specified and as directed.
Dismantling fencing wire mesh any type complete all as specified and as directed.
Dismantling , post or struts (wood, steel, or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and as directed.
Supply only chain link MS galvanised fencing any size or type complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and as directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and as directed. Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures shall be mejured and paid under separat items. The make of the accessories shall be of that switchs. Cost of cutting and chasing of any discraption shall be deemed to be included in quoted rates of this items.
All as per ser item No. 160 here-in- above but one light point controlled by one switch.
All as per ser item No. 160 here-in- above but one fan/exhaust fan/wall fan point controlled by one switch and one regulator.
All as per ser item No. 160 here-in- above but one 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per ser item No. 160 here-in- above but one 5 pin 6 amps socket point controlled by one 6 amps switch on same board
All as per ser item No. 160 here-in- above but one bell/buzzer point controlled by one bell push.
All as per ser item No. 160 here-in- above but one light point controlled by two 2 way switches.
All as per item No. 160 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:-
All as per ser item No. 167 here-in- above but one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
All as per ser item No. 167 here-in- above but one 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board.
All as per item No.160 above ,but point wiring with 4.0 sqmm and earth conductor of size 2.5 sqmm complete all as specified and as directed.
Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and as directed.
Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and as directed.
Supply & fixing modular type bell push 6 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and as directed.
Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and as directed.
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and as directed.
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and as directed.
Supply & fixing modular type step fan speed regulator 100/120W, 2 module,230volts,AC, 360 degree rotation 0 to 4 steps, ISI Marked complete all as specified and as directed.
Supply & fixing modular flush metal box 1/2 module complete all as specified and as directed.
Supply & fixing modular flush mental box 3 module complete all as specified and as directed.
Supply & fixing modular flush mental box 4 module complete all as specified and as directed.
Supply & fixing modular flush mental box 6 module complete all as specified and as directed.
Supply & fixing modular flush mental box 8 module complete all as specified and as directed.
Supply & fixing modular flush mental box 12 module complete all as specified and as directed.
Supply & fixing modular white cover plate with frame, 1 module complete all as specified and as directed.
Supply & fixing modular white cover plate with frame, 2 module complete all as specified and as directed.
Supply & fixing modular white cover plate with frame, 3 module complete all as specified and as directed.
Supply & fixing ,modular white cover plate with frame, 4 module complete all as specified and as directed.
Supply & fixing modular white cover plate with frame, 6 module complete all as specified and as directed.
Supply & fixing modular white cover plate with frame, 8 module complete all as specified and as directed.
Supply &fixing modular white cover plate with frame, 12 module complete all as specified and as directed.
Supply and fix call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and as directed.
Supply & fix angle lamp holder, insulated body with back plate for batten fittings including S F of LED lamp 10 watts complete all as specified and as directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and as directed
Supply and fixing LED lights fitting 1 x 16 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. all as specified and as directed.
Supply and fixing round shape 12 watt 230Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including removing old unserviceable item complete all as specified and as directed.
Supply & fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as speicifed and as directed.
Supply, installation, commissioning and testing of LED based ceiling suspended double dome operation theater light with provision only for Camera to be fitted inside the dome as and when required at later stage in complaince with medical device electric standard IEC-60601-2-41, with each dome consisting of minimum 30 LED's and maximum 120 LEDs housed in dome with diameter ranging between 500mm, suspended through a ceiling assembly with spring arm system to provide preceise positioning of the OT light as required during surgery complete with UPS including sealed maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring for hanging arrangements as per manufacturers guidelines with following specifications :- Make : Hospedia Medicare/ MARTIN/MEDITEC or equivalent, (Model-LED 50 Double Dome). Technical Specification :- Main Dome Satellite Dome Indensity @ 1 meter (Lux) 160000+10% 130000+10% Adjustable Field Diameter (cm) 14-38 14-38 Depth of Illumination L1+L2 (cm) > 100 > 100 Color Rendereing Index (CRI) (Ra) 95+3% 95+3% Colour Temperature (K) 4500+10% 4500+10% Intensity control(%) 25-100 25-100 Type of Field focusing control By Sterllizable handle By Sterllizable handle Type of Intensity control By control panel on lamp head By control panel on lamp head Electrical & Mechanical Specifications Power Supply Input Voltage (V) 220-230V 220-230V Power consumption (W) < 150 < 150 Frequency (Htz) 50/60 50/60 Dome Diameter 500-700mm 500-700mm LED service life (hrs) > 40000 > 40000
Supply & fix sheet metal enclosure with metal type AD/DD,415 volts AC,VTPN DB, 8 way+24 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bar and MCCB incomer,FP, and MCB SP /TP as outgoing and complete for IP54 DBs protection including taking down sheet metal enclosure and making good the disturbed surface with existing surface and colour shade complete all as specified and as directed. Make: Cat Part No.DHDLVDRWAOFO08 of Havells or equivalent in any approved make.
Supply & fix Triple pole and neutral double door 4 way 415 volt, sheet metal enclosures for DB's when MCBs to be used including making good the disturbed surfaces to match with existing surface and colour coatand including removing old unserviceable item complete all as specified and as directed.
Supply & fix SPN distribution board 12 way 240 volts double door Sheet metal enclosures for DB's when MCBs to be used and including making good the disturbed surfaces to match with existing surface and colour coat and including removing old unserviceable item complete all as specified and as directed.
Supply & fix SPN distribution board 8 way 240 volts double door Sheet metal enclosures for DB's when MCBs to be used and including making good the disturbed surfaces to match with existing surface and colour coat and including removing old unserviceable item complete all as specified and as directed.
Supply and fixing rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 to 32 AMPS and current carrying capacity in the MCB DB complete with connection testing and commissioning ISI marked complete all as specified and as directed.
Supply and fixing rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMPS and current carrying capacity in the MCB DB complete with connection testing and commissioning ISI marked complete all as specified and as directed.
Supply & fix MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA necessary lugs, thimbles, nuts, bolts and washers and including necessary neccessories complete all as specified and as directed.
Supply & fix MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA necessary lugs, thimbles, nuts, bolts and washers and including necessary neccessories complete all as specified and as directed.
Supply & fix MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KAwith necessary lugs, thimbles, nuts, bolts and washers and including necessary neccessories complete all as specified and as directed.
Supply & fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32A 415 V with earth plug suitable for three phase machineris complete all as specified and as directed.
Supply & fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN 20 Amps, 240 Volts suitable for AC's/Geysers complete all as specified and as directed.
S & F for sub main wiring complete with 4 X 10 + 2 X 6.0 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, of FRLS is PVC insulated copper conductor , single core cable in surface/ recessed concealed complete as required and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and as directed. Note : - Four run of 10 sqmm single core copper conductor cable and 02 run of 6.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
S & F for sub main wiring complete with 2 X 6.0 + 1 X 4.0 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, of FRLS is PVC insulated copper conductor , single core cable in surface/ recessed concealed complete as required and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and as directed. Note : - Two run of 6.0sqmm single core copper conductor cable and 01 run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
S & F for sub main wiring complete with 2 X 4.0 + 1 X 2.5 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, of FRLS is PVC insulated copper conductor , single core cable in surface/ recessed concealed complete as required and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and as directed. Note : - Two run of 4.0sqmm single core copper conductor cable and 01 run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Taking down Ceiling/Exhaust fan of any discription from its position and fan shall be deposited in MES store yard complete all as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F exhaust fan, steel body AC single phase, 230 V of size 300 mm sweep, with blades, and frame and louvers as approved colour and connecting of electrical connections and testing complete all as specified and as directed.
Supply and fix of water storage heater (Geyser) of 25 ltrs capacity, BEE 5 star, vertical type steel body with copper inner tank and heating element upto 2 KW,240 volts, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos,hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 nos, chromium plated brass stop cock 15 mm bore -01 No, safety valve and including necessary plumbing work, testing all as specified and as directed.
Supply and fix wall mounting fan 400 mm sweep, high speed, 240 volts AC, 50 Hz and fixing arrangement on wall including providing holes & fasteners 02 Nos complete all as specified and as directed.
Dismantling of old unserviceable Air Curtain Unit and shall be desposited to MES store yard complete all as directed.
Supply, install, commissioning and testing of Air curtain Unit having size 1500x230x212 single phase 220v/50Hz, 700Wnoise level 50-70db of make -DOLPHY, Model DACN009 or AIROTEK Make with complete fitting & accessories as required complete all as per manufacturer instrutions complete all as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised earth lead wire of size 4.0 mm dia from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,including excavation/earth work in any stage and returning filling, removal of surplus soil and testing for required value complete all as specified and as directed including testing on complete.
Supply & fix Earth continuity conductor or main earthing lead fix to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. (for additional eathing lead beyond 7.5 metres per earth, if so required at site) and interconnection of earth pits complete all as specified as directed.
Supply, erecting, testing and commissioning of silent (Sound proof enclosure) type Diesel Engine Driven Generating Set capable of delivering 200 KVA, (160 KW at 0.8 Power Factor) Water&Coolant cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ 1500 RPM complete with Automatic on Mains Failure (AMF) control panel. Noise levelas per CPCB norms-less than 75 dB, Fuel consumption at 100% load not more than 45.9Litres/Hour , at 75% load-34.4 Litres/Hour and at 50% load-25.2Litres/ Hour. Fuel tank capacity -460 Lts.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible copuling and mouted on common base frame and complete with control panel suitable for climatic conditions prevelanet at Barracpore, Kolkata with suitable derating factors as applicable and meeting specifications as elaborated here-in-after. (i) ENGINE (Prime Mover) : Diesel Engine 1500 RPM, direct injection, 6 cylinders, four stroke, confirming to IS 10002, ISO-3046, BS 5514, water and coolant cooled, naturally turbo charged, capable of giving adequate power to drive alternator capable of delivering 200 KVA at outdor atmospheric conditions at Kolkata, (.Taking all derating factor into consideration), 24 Volt battery(2*150 AH) electric start complete with fly wheel all standard fittings / fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system with electronic governor and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc.) fuel tank and first fill of lub oil and other consumables etc and self starting system incl batteries etc complete. (ii) ALTERNATOR : Brushless AC alternator, 3 phase, 415 Volt, 4 wire, rated for output of 200 KVA,(160 KW at 0.8 Power Factor) 1500 RPM. In SPDP enclosure, self-excited & self-regulated, floor mounted with ball or bearings on end shields. The alternator conforms to IS: 4722, BS EN 60034-1 & will be suitable for tropical condition. Automatic voltage regulator coupled through flexible coupling with and to match the above engine. Alternator efficiency at 100% load 0.8 pf-Minimum 93.7% and at 75% load 0.8 pf- Minimum-94.3%. and at 50% load & 0.8 PF - minimum 94.3%. (Time permitted to build up rated voltage at rated RPM-Maximum 5 sec provided engine reach the rated speed. Short circuit withstand time-3 times rated current for 10 secs. Overload withstand capacity-10% overload for one hour once in 12 hours) (iii) BASE PLATE : As per manufacturers recommended design/specifications. (iv) ACOUSTIC INSULATION : 1. Sound proofing of the enclosure done with quality Foam/Rock wool confirming to IS: 8183. 2. Acoustic form shall be fire retarded and fire resistant. 3. Attenuates are provided to control sound at entry and exit to and from the container. 4. Specially designed Residential Silencer is provided. (v) Foundation/Plinth/Base : Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the set and height of plinth shall not be less than 0.5M (vi) AMF Panel: Powder Coated Control Panel manufactured with CRCA sheet suitable for Automatic on Mainsfailure with auto load changer suitable capacity of MCCB and contactor of suitable rating with short circuit protection, controller with displays of voltage, current, KW , frequncy and KWH indicating lamps for "load-ON" and "set running". Current transformers of suitable rating, Aluminium Bus bars of suitable capacity with incoming and outgoing terminations and control fuses duly wired and ferruled complete on all respect. (vii) Earthing : (i) Provision of four numbers of Earth pit for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below normal ground level) with top edge of plate not less than 1.5 Meter below normal ground level connected to galvanized iron earth strip 32x6 mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, supplying and laying charcoal dust, common salt PCC 1:2:4 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed.(ii) AMF Panel shall be provided with 2 Nos Earth points with 4 mm GI wire as earthing leads and GI Plate earthings. (viii) MISC : Tool kit, operation and maintenance catalogue, spare part list, overhaulling manuals, guarantee card etc shall be provided as per manufacturer standard parctices. (ix) Fully automatic AC operated additional battery charger of suitable capacity incl suitable size twin core copper wires fixed with copper lugs shall be provided from charger to batteries for charging of batteries without extra cost. (x) to be added Make of Engine: - KOEL GREEN/ Cummins/Ashokleyland/Greaves Cotton. Make of Alternator- KOEL GREEN/Alstom/Crompton Greaves/Simens/ Bharat Bijalee/STAMFORD. Make of sound proof enclosure:- KOEL GREEN/Jackson/Sudhir/Cummins/Greaves Cotton/Ashok Leyland. (x) Controller shall be microprocessor based fully configured with garphical LCD display, monitoring features for all electrical parameters, lub oil parameters, Battery parameters and self diagnostics faeatures for all important parameters.
Supply, laying, testing LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 400 sqmm,3.5 core laid in trenches/through pipes/ ducts/walls/Boring and including cable connections with necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers including taking down unserviceable cable etc complete all as specified and directed.
Supply, laying, testing LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 70 sqmm,3.5 core laid in trenches/through pipes/ ducts/walls/Boring and including cable connections with necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers including taking down unserviceable cable etc complete all as specified and as directed.
Supply, laying, testing LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 50 sqmm,3.5 core laid in trenches/through pipes/ ducts/walls/Boring and including cable connections with necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers including taking down unserviceable cable etc complete all as specified and as directed.
Supply, laying, testing LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 16 sqmm,4.0 core laid in trenches/through pipes/ ducts/walls/Boring and including cable connections with necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers including taking down unserviceable cable etc complete all as specified and as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,including excavation/earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and as directed.
Supply & fix galvanised Iron strip 32x6mm burried in ground (for additional eathing lead beyond 7.5 metres per earth, if so required at site) and interconnection of earth pits complete all as specified and as directed.
Supply, installation, testing and commissioning of factory fabricated, CPRI approved with IP-54 Protection LT panel board of suitable for working on 3 phase, 4 wire,415volts,AC,50Hz, outdoor type, made out of 3.15 mm thick CRCA sheet including powder coated. Cubicle, floor mounted,free standing,dust and vermin proof, air ventilation .Panel board shall have front and rear opening with hinged doors and rubber gaskets,handles,industrial type locking arrangement, cable alleys, bus bar chamber and switch gear compartment, bottom cable entry holes for incoming and outgoing cables,earthing terminals,affixing danger notice plate, each compartment shall be numbered/lettered for indication, aluminium bus bar TPN 800 Amps capacity duly covered with heat shrinkable sleeves colour coaded duly fixed on DMC/SMCinsulators housed in a separate bus bar chamber and control wiring with PVC insulated, miltistranded flexible copper conductor cables of adequate size and length, protection fuses,MCBs, connectors,LED phase indication lamps(RYB)etc incoming and outgoing MCCBs shall have extended bus bar links and mounted on suitable size MS angle iron frame duly painted also including provision of PCC : 1:2:4 type B1 (using 20 mm graded stone aggregate) as in foundation/platform etc as per manufacturer designed subject to approval of GE to suit the site requirement, complete all as specified and directed including taking down old unserviceable LT Panel and comprising of following:- (i) On-Load Changeover switch 400 Amps, 4 pole, 415 volts, 50Hz.-01 No (Make :- Legrand/ ABB/ L&T) (ii) MCCB 400 A,4Pole,35/36KA,415volts,AC,50Hz -01 Nos.(Make :- Legrand/ ABB/ L&T) -Incomer (iii) MCCB 160A,4Pole,35/36KA,415volts,AC,50Hz -06 Nos.(Make :- Legrand/ ABB/ L&T) (iv) MCCB 100A,4Pole,25KA,415volts,AC,50Hz -1 Nos. (Make :- Legrand/ ABB/ L&T) (v) MCCB 63A,4Pole,16KA,415volts,AC,50Hz - 1 Nos .(Make :- Legrand/ ABB/ L&T) (vi) MCCB 32A,4Pole,16KA,415volts,AC,50Hz - 02 Nos. (Make :- Legrand/ ABB/ L&T) (vii) Aluminium bus bar TPN 800 Amps capacity - 1 set ( four Nos) (viii) Digital Voltmeter with VSS-01 No (ix) Digital Ammeter with CTs & ASS-01 No (x) LED indicator lamps RYB - 01 set (xi) Control wiring / fuses and relays for functioning requirements
M & L for brick sub class 'B' 250mm x 125mm x 75mm and laid in trenches as in protection of UG cable complete all as specified and as directed.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches upto 23 cm and punning to 18 cm complete all as specified and directed. Note: Punned thickess i.e 18 cm shall be measured for payment purpose.
M&L for making holes in road corossing, trenchless by mean of horizental direction drilling technology for inserting of 80mm bore GI pipe by specialist agency complete all as directed. Note:- The depth of hole shall be approximatly 1 meter below road level.
Material & labour for GI pipe 80 mm bore "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and as directed.
Material & labour for GI pipe 50 mm bore "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and as directed.
Material & labour for GI pipe 40mm bore "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and as directed.
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all as specified and as directed.
Returning, filling in soil including spreading, leveling,watering and well rammimg in layer n exc 25 cm complete all as specified and as directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed
Supply and fixing LED building security light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down of old unserviceable Street Light fitting complete all as specified and as directed.
Supply and fix GI bracket pipe of size 40 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate MS flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing any place of poles with nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and as directed.
M&L for synthetic insulation mat of 1 mtr x 2 mtr x 2 mm size for voltage upto 3.3 Kv for electrical purpose as per IS 15652-2006 suitable for electrical shock safety complete all as specified and as directed.
Supply and lay 3 layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls ceiling or in floors etc of size 50 mm dia complete all as specified and as directed.
Supply and lay 3 layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls ceiling or in floors etc of size 32mm dia complete all as specified and as directed.
S & F PP-R gate valve (Brass Insert) of 32mm bore complete all as specified and as directed.
S & F PP-R gate valve (Brass Insert) of 50mm bore complete all as specified and as directed.
Cutting of existing cast iron pipes 100 mm dia for taking up branch connections including insertion of new tees,leadjoint etc complete all as specified and directed. Note :- Earth work excavation shall be measured and paid separately.
Construction of valve chamber (for gate valves) 600mm x 600mm x 750mm with 200 mm thick solid concrete block masonary, block casted using PCC 1:3:6 type C-1mix built in cement and sand mortar 1:6, 15 mm plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement 15 mm thick,MS sheet cover including 40x40x3 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1, with 25x6 mm flat iron hold fast,handles,hinges with locking arrangments, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface including necessary excavation and earth work complete all as specified and as directed.
Dismantling of non CFC based old vintage central AC Plant of 3 x 17.5 TR capacity complete set with all connected items such as cooling tower, condenser, Blower motor, AHU, Old LT Panels, ducts etc and deposited to MES store yard for further disposal action complete all as specified and as directed.
Designing, Supply, Installation, Erecting, Testing and Commissioning of Micro- Computer / Micro-Processor controlled, water cooled, Energy-Efficient, Packaged Chilled water based, Central HVAC (Heating, Ventilating and Air-Conditioning) plant for operation theatre and X ray at Base Hospital Barrackpore, plan view of bldg as given by OIC of OT is attached as Appendix I and height is appx 14 ft up to false ceiling for rough idea but actual to be verified by contractor. Heat load of suitable Capacity to be worked out by the contractor based on his own Design calculations but not less than 75 TR (25 TR x 3 Units) two working one standby and not more than 100 TR suitable for 24 hours round the clock operation (Exact capacity to be worked out by the contractor, based on his own heat load calculations, refrigerant to be used, Standard configuration of packaged chillers available with stipulated reputed manufacturers and overall design) to meet inside design conditions, as specified in Annexure –I, with. Two units of 50% of full load capacity of heat-load as main operating units and One units of 50% of full load capacity of heat load as Standby unit, i.e. The plant shall have Three(03) Nos. of packaged water cooled Compact semi-hermetic screw compressor chiller package units with shell and tube type condensing units of 50% capacity each) complete in all respects with Three(03) Nos. of factory assembled Packaged Chilling Units (Each comprising of Energy Efficient Semi-hermetic Screw Compressor, Energy Efficient Electric Motor to drive the Compressor, Integral finned shell and tube type water condenser and base frame) along with 3 Nos of Cooling tower (induced draft FRP type)(TR to be greater than that of Chiller units i.e. greater than 25TR), 3 Nos of Condenser water circulating pumps (Two working and one standby) with condenser water pipe network, 1 No. of Chilled water tank of suitable capacity, Suitable Nos. of Chilled water Circulating pumps (including 33% standby) with chilled water insulated pipe networks, Suitable No of Hot Water Generator , Suitable Nos. of duct heater with connection ,suitable Nos. of Air handling unit(weather making chamber, with air- filters, HEPA filters wherever required, fresh air grills, Cooled air ducting, Air diffusers, fire dampers, with provisions of winter heating, humidifiers etc. with first charge of refrigerant and oil filling complete in all respect and as specified below with all control accessories, LT panel board necessary underground cables and electrical earthing including necessary civil work for foundation, all as specified and as described here-in-under and as per manufacturer instruction / recommendation along with vibration pad. NOTES FOR ITEM NO 250 ABOVE:
The above item shall be quoted and executed on ground based on Contractor’s own design on Turnkey execution and Performance Guarantee Basis. The Performance Guarantee is related to achieving the indoor conditions, within the air-conditioned space as stipulated at Annexure-I. The contractor shall be responsible that the HVAC system installed based on his own design results into meeting all the parameters of desired indoor conditions, as specified at Annexure-I, as long as outdoor conditions are within the range (as specified at Annexure-1) during all seasons i.e. Summer, Winters and Monsoons on 24 hours operation round the year basis. The Contractor shall also be responsible for desired operational efficacy and desired efficiency of the HVAC System during its life cycle of minimum fourteen years. The specifications of Sub Systems of HVAC Installations given-here-in after (in Appendix II) are on Minimum Basis. In case Contractors design requires quantities & specifications lower than those specified. The Specified quantities & specifications shall be followed. In case contractors design require higher quantities & specifications the same higher quantities and specification shall be followed.
There are various space constraints at site. The Contractor is advised to visit the site of work and familiarize himself with these constraints before quoting the rates. Site visit may be arranged with prior intimation to Garrison Engineer (I) (Project) Kolkata. Irrespective of the fact whether the contractor has visited the site or otherwise, no claims arising out of not being familiar with site constraints shall be entertained later.
The Contractors must specifically note that Plant room is to be setup in an existing building nearby (approximately 25 Meters away). The capacity of plants equipments etc must take into consideration the losses in temperature of Chilled/Hot water in recirculation system. The extra cost of laying insulated pipe line from Plant room to main building also needs to be taken into consideration. Also the cooling towers of the AC pant are to be erected on the roof top of an existing building. The Contractor is advised to take all these constraints into considerations.
The successful Contractor shall submit the following documents within Four weeks of placement of work order, for approval of Garrison Engineer.
(a) Heat Load Calculations, separately for Summers, Winters and Monsoons. The Contractor should work out heat load based on the outside conditions prevalent at Barrackpore, Kolkata and desired inside conditions as specified at Annexure-I, taking into considerations the building plan, height, as given in the tender and arrive at the plant capacity to achieve the indoor conditions as given in Annexure I. In case the plant capacity as per his own calculations works out to be less than 50 TR, HVAC System of 50 TR Shall be provided. In case the plant capacity as per his own calculations works out to be more than 70 TR, he should refer the matter back to Department with all calculations and should not quote for tender, till final decision is communicated. In case any parameter required for HVAC design is missing, the Contractor shall obtain the parameter by visiting the site, with prior appointment with Garrison Engineer (I) (P) Kolkata. Achieving energy efficiency and least life-cycle cost shall be the guiding factor in the heat load calculations and the overall design of the HVAC System. Unnecessary additions to heat load and the capacity of HVAC System shall be avoided. For achieving energy efficiency of HVAC System the worst conditions of ambient Dry Bulb Temperature and Wet Bulb Temperature occurring concurrently for less than 0.4 %, (Percentile hours) as defined and stipulated in IS 7896:2001 and National Building Code(NBC)-2016 shall be ignored. i.e. As per stipulation in IS:7896:2001 and NBC-2016, the worst outdoor ambient conditions occurring on an average for less than 35 hours in a year shall be ignored. However Safety margins of 10% shall be considered in design as elaborated in Annexure-I
(b) Plan depicting layout of all equipments and Sub-systems of the HVAC System. This shall be self contained and self explanatory representation of layout of equipments and sub-systems. The dimensioned drawing of the site of work clearly marked with the space to be air-conditioned, AC Plant room and the AHU Rooms are forming part of the tender. The Contractor is advised to use the same drawings, for making the layout plan of all equipments.
( c) Schematic Diagram of the Electrical system: This shall contain specifications, sizes, current, voltage and fault levels ratings of all cables, switch gears and instrumentation & control systems and all interlocking.
(d) Dimensioned drawing indicating the Duct layout. – One tentative layout of proposed ducting arrangement is enclosed with the Tender. This drawing is for reference only and indicating the structural opening etc as are provided in the building to suit this layout. The Contractor must however prepare his own ducting drawings to suit his design and to achieve the conditions stipulated at Annexure-1. The duct design drawings Shall contain material of construction, sizes, thickness etc of all ducts, insulation materials, air diffusers, fire dampers etc complete in all respect. All design calculations in support of the duct design shall also be enclosed. The duct design submitted by the contractor shall be approved by the department. Any additions/alterations carried out by the department, prior to communication of approved duct layout as well as during the execution of work shall be carried out by the contractor at no extra cost to the department. All such additions/alteration shall, however be confined. All such addition/ alteration shall however be confirmed to the duct layout in the air conditioned space specified in the tender only, no new areas, not to be air conditioned in the guise of amendments in duct layout. All Civil works for making opening and making good the disturbed surface shall also be within the scope of work of this tender.
(e) Yard stick for making interim payments: This document is required for regulating interim payments (Running Account Receipts (RARs)) to the contractor. This shall contain the important stages in execution of the project up to provisional completion (Phase-1 test) and corresponding percentage (%) of the total lump sum amount quoted by the contractor, totaling up to 95 % of the total lump sum quoted amount. An amount of 5% of the total lump sum amount shall be retained by the department for Phase -II tests. This shall be released on successful completion of Phase-II tests only. The yard stick submitted by the contractor shall be for suggestion/ indicative purposes only. This shall be approved by the department and communicated to the contractor, within one month of placement of work order for AC work.
(f) The design and other technical details mentioned above at Ser No 249.05 to 249.08 shall be got vetted by the Contractor from any of the Indian Institute of Technology (IITs)/ National Institute of Technology(NITs)/Government owned Engineering College having Refrigeration & Air-Conditioning as one of Engineering stream at Graduation/Post-Graduation level OR from Corporate Office/ Head Office/ of any one of the approved Original Equipment Manufacturers i.e. VOLTAS /DIAKIN /BLUE STAR /HITACHI.
(g) All the documents/ technical details mentioned above duly vetted as specified above shall be approved by Garrison Engineer (GE) within 15 days of submission. The GE may approve the documents as submitted by Contractor or may suggest modification/ alteration in documents/ technical specifications duly supported with reasons for the same. The work shall be executed based on the approved documents. In case of any dispute the matter shall be referred to Accepting Officer. The decision of Accepting Officer shall be Final and Binding.
The refrigerant to be used in the HVAC System shall be Non- CFC and Non-HCFC based (R-134 A or Superior) and shall be meeting all environmental safety stipulations as laid down by the Government of India as on date.
The Department shall be responsible for providing electric connection, at 415 Volts, 3 Phase, 4 Wire, 50 Hz, through a suitably rated electrical cable up to inside of AC Plant room and water connection, through a suitable size pipe, available in near vicinity of AC plant Room (up to a maximum distance of 5 Meters from the AC plant Room). All other works for the complete HVAC system shall be the responsibility of the contractor. The Unit rate quoted for this item shall be deemed to be inclusive of all items, sub systems, civil works and incidental works.
The contractor should get the plant installed only by any one of the original equipment manufacturers eg. VOLTAS/DIAKIN /BLUE STAR/ HITACHI with their own makes or with their recommended makes of complete components/items. Provision of combination of various items of different manufacturer of above or their recommended makes or any other makes is not acceptable. The contractor shall intimate the name of OEM namely Voltas/ DIAKIN/ BLUE STAR/ HITACHI and submit a certificate from the OEM confirming that the entire AC plant work shall be got executed with their recommended make through them/ their accredited agencies, within one month of placement of work order for AC on the contractor.
The capacity of plant capacity shall be based on manufactures design but it shall be of 3 units (2 working and 1 standby) each capable of meeting 50% of full load capacity of heat load independently.
The first fill of all consumable items including refrigerant, compressor oil, lubricant, etc shall be provided by the contractor. The contractor shall also be responsible for making up / replenishing these consumables during testing and the defect liability period of three year.
The design drawings and other technical details submitted by the successful contractor, along with all calculations, drawings, technical write ups etc shall become department property. Department may use these subsequently as deemed necessary. The contractor shall have no claim on these documents and their subsequent use by the department.
A tentative BOQ with minimal specification is given below, as APPENDIX II purely for facilitation of appreciation of Design methodology to be generally adopted by the Contractor and for preliminary estimation. The quantities given are approximate and are as assessed. The Contractor to specifically note that no financial adjustment for variation in quantities (Plus or Minus) shall be done. The Work shall be executed purely based on approved design as elaborated here-in-before.
MS SHRI B.C. DAS
SVC PROJECTS PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .