Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹21.2 L+₹44,435 (2.14%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹22.7 L+₹1.9 L (9.10%)Rejected-Finance 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹24.0 L+₹3.2 L (15.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹24.5 L+₹3.7 L (17.8%)Rejected-Finance 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
16 Jun 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_444845_1
GE MAINT EZHIMALA 8383
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹60,000
Yes
14 Jul 2021
21 May 2021
18 Jun 2021
21 May 2021
16 Jun 2021
4 Jun 2021
22 May 2021 - 29 May 2021
Amount
M&L for submain wiring using 2 runs of 2.5 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through concealed/open conduit along with 1 run of 2.5 sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
All as per item No.01 above but in PVC casing and caping of suitable size complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring using 2 runs of 4 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing caping along with 1 run of 4 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
All as per item No.03 above but in PVC conduit of suitable size complete all as specified and directed by Engineer-in-Charge.
All as per item No.03 above but in PVC conduit of suitable size and FRLS cable of 2 runs of 10 sqmm with earth wire 10 sqmm 1 run complete all as specified and directed by Engineer-in-Charge.
All as per item No.03 above but in PVC conduit of suitable size and FRLS cable of 2 runs of 6 sqmm with earth wire 6 sqmm 1 run complete all as specified and directed by Engineer-in-Charge. Note for Item No 1 to 6:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Three runs of cable and one run of conduit /cassing & capping with necessary accessories will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for submain wiring using 4 runs of 4 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing caping along with 2 runs of 4 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
All as per item No.07 above but in PVC conduit of suitable size complete all as specified and directed by Engineer-in-Charge.
All as per item No.07 above but in pvc conduit of suitable size 4 runs of 6 sqmm cable with earth wire 6 sqmm 2 run complete all as specified and directed by Engineer-in-Charge. Note for Item No 7 to 9:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Six runs of cable and one run of conduit /cassing & capping with necessary accessories will be measured as one unit length. (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
Supply and fix 3 phase static electronic energy meter accuracy class 1.0, 3x240V, 50Hz with back light LED display of rating from 10 to 60 Amps with special features like TOD tamper logging, optical communication port and display in absence of power complete all as specified and directed. Make:- L&T, HPL,Elmeasure or equivalent as approved by GE. Note:- Contractor has to deposit Old energy meters to MES for safe custody and it will be MES property and contractor has to submit the old meter Sl no, final reading of old meter, New meter Sl No, initial reading of the new meter for proper accounting of revenue.
Supply and fixing in repair MCB protected socket PVC plastic Base model with one single pole MCB, AC 240 Volts, 20/32 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB DB TPN 415V double door type 4 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail suitable for fixing existing space and model vertical or horizontal complete all as specified and directed by Engineer in charge.
S&F in repair MCB DB TPN double door for 8 way with 200 Amps rated bus bar 415 Volts complete all as specified and directed by Engineer in charge.
S&F in repair MCB DB TPN double door for 12 way Vertical Type with 200 Amps rated bus bar 415 Volts complete all as specified and directed by Engineer in charge.
S&F in repair VTPN MCCB DB 415V double door type 8 way with bus bar of appropriate current carrying capacity,isolated neutral link, earth bar suitable for fixing of MCCB four pole 100 A/ 125 A/ 160 Amp and din rail suitable for fixing existing space and model vertical complete all as specified and directed by Engineer in charge.
S&F in repair MCB TPN 415 Volts 40 Amps ,C series, 415 volts ,50 Hz, 10 Ka breaking capacity complete all as specified and directed by Engineer in charge.
S&F in repair MCB TPN 415 Volts 63 Amps C series, 415 volts ,50 Hz, 10 Ka breaking capacity complete all as specified and directed by Engineer in charge.
Supply and fixing in repair MCB TPN AC 415 Volts, 50 Hz , C series 10 kA breaking capacity, 25/32 Amps complete all as specified and directed by Engineer in charge.
S&F in repair MCB single pole 5 to 32 Amps capacity,C series 230 Volts 10 KA breaking capacity complete all as specified and directed by Engineer in charge.
S&F in repair MCB single pole and neutral 32 Amps capacity, C series, 10 KA, 50 Hz ,230 Volts complete all as specified and directed by Engineer in charge.
S&F in repair MCB single pole and neutral 40 Amps capacity, C series, 10 KA, 50 Hz ,230 Volts complete all as specified and directed by Engineer in charge.
S&F in repair RCBOs 4 pole 30m Amps,63 Amps,415 Volts complete all as specified and directed by Engineer in charge.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, MCB/ MCCB/ MCB DB/ earth plug and socket etc and making good matching to the existing colour to the disturbed surface complete all as specified and directed by Engineer in charge.
M&L color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size, concealed / semi concealed/open suitable size modular metal flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches or sockets regulators etc including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly all as specified for the following:- Note:- i. Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. ii. Same size wire shall be used for phase, neutral and earth conductor. iii. The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads.
(a) One Light/ fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amps on the same board with other switches
(c) 5 Amps socket point on independent board
M&L color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC Casing and caping of suitable size, suitable size modular metal flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FRLS 1.5 sqmm earth wire copper insulated connected to common earth dolly all as specified for the following:-
(a) One Light/ fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amps on the same board with other switches
(c) 5 Amps socket point on independent board
All as per item no 24 here in above but 2.5 sqmm for 5/15 Amps socket on independent board complete all as specified and directed by Engineer in charge.
All as per item no 25 here in above but 2.5 sqmm for 5/15 Amps socket on independent board complete all as specified and directed by Engineer in charge.
Supply and fix in repair lamp holder,PVC/Polycarbonate type with back plate suitable to batten fittings complete all as specified and directed by Engineer in charge.
S&F in repair calling bell, ding dong AC 230 Volts, single pole complete all as specified and directed by Engineer in charge.
S&F in repair ceiling rose 3 terminal/PVC/polycarbonate isolated body complete all as specified and directed by Engineer in charge.
S&F in repair modular switch one way 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in repair modular socket 6 Amps 2/3 pin 2 module complete all as specified and directed by Engineer in charge.
S&F in repair modular socket 6 Amps/16 Amps 3 pin 2 module multipurpose complete all as specified and directed by Engineer in charge.
S&F in repair modular switch one way 16 Amps 1 way 1 module complete all as specified and directed by Engineer in charge.
S&F in repair modular two way switch 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in repair modular bell push flush type 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in repair modular fan step regulator, 2 module complete all as specified and directed by Engineer in charge.
Supply and fixing in repair 6 Amps 3 pin Plug top complete all as specified and directed by Engineer in charge.
Supply and fixing in repair 16 Amps 3 pin Plug top complete all as specified and directed by Engineer in charge.
S&F in repair Switch socket combination 6 Amp with PVC box complete all as specified and directed by Engineer in charge.
S&F in repair Switch socket combination 16 Amp with PVC box complete all as specified and directed by Engineer in charge.
Supply and Fix in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed by Engineer in charge.
S&F in repair MCB DB SPN 230V double door type with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete of following size:-
Supply and fixing in repair Modular white cover plate with frame, 2 module complete all as specified and directed by Engineer in charge.
All as per item No.44 here in above but 3 module.
All as per item No.44 here in above but 4 module.
All as per item No.44 here in above but 6 module.
All as per item No.44 here in above but 8 module.
Supply and fix in repair modular box suitable for fixing 1/2 module all as specified and directed by Engineer in charge.
Supply and fix in repair modular box suitable for fixing 3 module all as specified and directed by Engineer in charge.
Supply and fix in repair modular box suitable for fixing 4 module all as specified and directed by Engineer in charge.
Supply and fix in repair modular box suitable for fixing 6 module all as specified and directed by Engineer in charge.
Supply and fix in repair modular box suitable for fixing 8/12 module all as specified and directed by Engineer in charge. Note for item No.49 to 53:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work of white wash /colur wash for matching with existing surface.
Supply and fix in repair thermostat for all type of geyser 2000 Watt as required at site complete all as specified and directed by Engineer in charge.
Supply and fix in repair geyser element 2000 Watt triangle type complete all as specified and directed by Engineer in charge.
Disconnect electric connections and taking down carefully unserviceable flood light/ Highbay light fittings of different capacities at URU tennies court /badmintion court etc.opening of cover and body for repair/ replacement of electrical items and refixing the same or fixing only new items /fittings including connecting/ testing complete all as specified and directed by Engineer in charge. Notes:- Fitting are fitted at 10 to 12 mtr height.The contractor shall arrange ladder/ scaffolding of required height at his own arrangement.The rates quoted are deemed to be included for the above provision.
Supply only Energy saving, enviormental friendly, long life, exclusive innovative die cast aluminium IP 66 flood light 150 W LED With 10 KV SPD complete all as specified and directed by Engineer in charge. Make:- Crompton Model Pluto Neo. cat part No LFLN-150-CDL/60-M or equivalent in Philips/ Wipro/Jaquar/Havells
S&F in replacement wall mounted 20 W LED 4ft batten output lumen > 100 lumen/watt ,CRI > 60,CCT >5500k ,internal surge protection up to 2 Kv , power factor > 0.93 having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cable suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make : Crompton cat No LDL 20 - CDL or equivalent in HAVELLS/ PHILIPS/WIPRO/JAGUAR
S&F spot light upto 7 watt WH/WW LED white body wall light for focusing wall complete all as specified and directed by Engineer in charge. Make : Luker Code No LSPO7 or equivalent in HAVELLS/ PHILIPS/WIPRO/JAGUAR
S&F in replacement wall mounted 10 W LED 2ft batten output lumen > 100 lumen/watt ,CRI > 80 ,CCT >5500 k , internal surge protection up to 2 Kv , power factor > 0.93 having extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver with all accessories pre-wired and including connecting up 3 core flexible copper conductor cablesuitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat No LDL 10 -CDL or equivalent in HAVELLS/PHILIPS/WIPRO/JAQUAR
Supply & Fix in replacement High efficacy 1x1 LED 18 watt surface full lit luminaire with glare free unifrom illumination with longer life and less maintenance and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals Luminous efficacy > 100/w, CCT .5500 k,CRI > 80,PF .0.95 all as specified and directed by Engineer in charge. Make:- Crompton LCDSPLN or equivalent in Havells, philips,Wipro, Jaquar
S&F in replacement of 18 W round surface mounted LED pannel, Pressurised Die cast Aluminium boHousing and high translucent frosted plastic diffuser with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make Crompton LCDSPLN-R-18-CDL Model Pearl Nios-R or equivalent in Philips/Wipro/Jaquar/Havells
S&F in replacement Decorative wall light (Globe Type ) fixture made up of poly carbonate suitable up to 1 x 10 W LED Bulb (B-22 base ) complete as specified and directed in replacement of existing CFL globe light fittings all as specified and directed by Engineer in charge. Make:- Havells code No. LHFOFUE1T21W012 or equivalent in Philips/ Crompton as approved by GE.
S&F in replacement of 18W round recess mounted LED, Pressurised Die cast Aluminium Housing and high translucent frosted plastic diffuser with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat No LSCRM-18-CDL Model Pearl Nios-R or equivalent in Philips/Wipro/Jaquar/Havelld
S&F in replacement Recess mounted down lighter 15W with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCRM-15W-CDL or equivalent in Havells,Wipro, Philips, Jaquar
S&F in replacement Recess mounted down lighter 12W with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCRM-12W-CDL or equivalent in Havells,Wipro, Philips, Jaquar
S&F in replacement Recess mounted down lighter 18W,warm white with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCRM-18-WW or equivalent in Havells,Wipro, Philips, Jaquar
S&F in replacement Recess mounted down lighter 12W ,warm white with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCRM-12W-WW or equivalent in Havells,Wipro, Philips, Jaquar
S&F in replacement Recess mounted down lighter 12W,warm white with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCSM-12W-WW or equivalent in Havells,Wipro, Philips, Jaquar
S&F in replacement Recess mounted down lighter 18W, with pressure diecast aluminium heat sink & PC diffucerin white powder coated finish withintegrated driver and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Crompton cat part No LSCSM-18W-CDL or equivalent in Havells,Wipro, Philips, Jaquar
S&F slim design LED 12W recessed square poly carbonate housing down lighter with superior light output integral driver. Efficacy 100 lm /w all as specified and directed by Engineer in charge. Make:- CG model QUARTZ+S cat part No LSDEP- 12-CDL or equivalent in Wipro/Philips/Jaquar.
S&F slim design LED 9W recessed square poly carbonate housing down lighter with superior light output integral driver. Efficacy 100 lm /w all as specified and directed by Engineer in charge. Make:- CG model QUARTZ+S cat part No LSDEP- 09-CDL or equivalent in Wipro/Philips/Jaquar.
S&F slim design LED 9W recessed Circular poly carbonate housing down lighter with superior light output integral driver. Efficacy 100 lm /w all as specified and directed by Engineer in charge. Make:- CG model QUARTZ+S cat part No LCDEP- 09-NW or equivalent in Wipro/Philips/Jaquar.
S&F slim design LED 9W recessed square poly carbonate housing down lighter with superior light output integral driver. Efficacy 100 lm /w all as specified and directed by Engineer in charge. Make:- CG model QUARTZ+S cat part No LSDEP- 09-NW or equivalent in Wipro/Philips/Jaquar.
S&F in replacement Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10 W with opal diffuser with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals all as specified and directed by Engineer in charge. Make:- Jaquar Cat part No LBL01x010xC or equivalent in philips, CG,Wipro
Supply & Fix in replacement 18 Watt High efficacy 1x1 LED flat panel with CRCA housing and high brightness LED for glare-free homogenous illumination all as specified and directed by Engineer in charge. Make:- Crompton Cat NO LCTLSNE-18-FO-CDL/ or equivalent in Philips/Wipro/Jaquar.
S&F surface/ ceiling mounted LED batten fitting 20W (4 feet) warm white extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver including taking down of old fittings all as specified and directed by Engineer in charge. Make:- Crompton TRIM LINE cat part No LDL-20 -WW or equivalent in Jaquar/Havells/ Philips/Wipro.
S&F surface/ ceiling mounted LED batten fitting 10W(2 feet) warm white extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver including taking down of old fittings all as specified and directed by Engineer in charge. Make:- Crompton TRIM LINE cat part No LDL-10 -WW or equivalent in Jaquar/Havells/ Philips/Wipro.
S&F in replacement Recess full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 W (2 ' x 2 ') in MS housing with opal diffuser with colour temp 6000K, Luminous efficacy-> 100/watt,CCT> 5500 k,CRI- 80,Power factor >0. 95,THD < 10 with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/ connection terminals including aluminium frame for fitting the same all as specified and directed by Engineer in charge. Make:- Havells/Crompton/Philips/Wipro/Jaquar.
Supply and fixing in repair capacitors 4 mfd, AC 440 Volts suitable for exhaust fan all as specified and directed by Engineer in charge.
Supply and fixing capacitors 2.5mfd, AC 440 Volts suitable for celling fan/exhaust fan all as specified and directed by Engineer in charge.
S&F 9 W LED lamp with base B22 complete all as specified and directed by Engineer in charge.
S&F 9 W LED lamp warm white with base B22 complete all as specified and directed by Engineer in charge.
S&F 9 W LED lamp warm white with base E27 omplete all as specified and directed by Engineer in charge.
S&F hylam sheet 3mm thick suitable for switch board etc complete all as specified and as directed by Engineer in charge.
Supply and fixing in repair MCCB four pole 100 Amps 16/18 kA 415 Volts, 50 Hz suitable for existing busbar all as specified and directed by Engineer in charge.
Supply and fixing MCCB four pole 160 Amps 25 kA 415 Volts, 50 Hz suitable for existing busbar all as specified and directed by Engineer in charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground, earth pit not less than 2.25 meter deep below ground level, connected to 4 mm size galvanized wire as earthing lead by means of bolts, nuts, check nuts, and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including provn of necessary excavation and earthwork in any type of soil, PCC pit, RCC cover and 20 mm bore medium grade watering pipe, water funnel with GI wire mesh, 15 mm bore medium grade protection pipe, common salt, charcoal dust, returning filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion all as specified and as directed.
Notes for all items of BOQ:- 1. The contractor has to (a) replace the items on complaint basis only. (b) depute one electrician and one helper to attend the day to day complaint during the entire contract period. (c) to provide his own arrangement to shift the materials (d) provide necessary tools and plants for attending the complaints (e) attend and complete the complaint within 24 Hrs. (f) Incase of Electrician and helper fails to attend the complaints a sum of Rs 1200/per day will deduct from payments. 2. The rates for which are deemed to be included in quoted rates.
Sreekrupa Enterprises
Benchmark Engineers and Contractors
CREATIVE BUILDERS
OM Enterprises
General Engineering and Constructions
ZOOM ENTERPRISES
pk janardhanan
PADMANABHAN. K.V
JEETH CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .