Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹45.5 L+₹3.5 L (8.41%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹45.8 L+₹3.9 L (9.23%)Rejected-AOC | L3 | Rejected-AOC Rejected being not L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Jul 2022, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
PROVN OF 400 METERS OF BOUNDARY WALL AT SUPPLY DEPOT AND PROVN OF KOTA STONE AT 20 X STAIRS OF JCOS OR MD ACCN BLDG NO. P-56 TO 71, P-74 TO P-89 AND P-230 TO 252 AT DOGRA LINE OF 6 GRENADIERS IN THE AREA OF AGE BR-II UNDER GE ROORKEE
2022_MES_527610_1
8392/183/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹96,000
Yes
6 Oct 2022
31 May 2022
4 Jul 2022
1 Jun 2022
2 Jul 2022
15 Jun 2022
Amount
Surface excavation in soft and loose soil not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Excavating in trenches in Soft/loose soil , not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in soft and disintegrated in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed .
Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
Form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete (Design Mix), M 25 (using 20mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (reinforcement to be measured and paid separately)
M & L Reinforced cement concrete (design mix) M 25 ( using 20mm graded stone aggregates) as in columns, pillars, posts & struts complete all as specified and directed . (reinforcement to be measured and paid separately)
M & L Reinforced cement concrete (design mix) M 25 ( using 20mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed . (reinforcement to be measured and paid separately)
M & L for brick work in CM 1:6 using Sub class ‘B’ Bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M & L TMT bars 10 mm dia and over cut to length, bent to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per item No 13 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
S & F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming to FE 410W (Gde E-250) complete all as specified and directed .
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing & straining and fixed to any type of standard rail incl securing or tying at crossing with and provision of galvanised MS wire staple or steel pins including dismantling Barbed wire any description complete all as specified and directed by Engr- In - Charge.
Material and Labour for rendering 15 mm thick cement plaster in cement mortar (1:6) on other than fair faces faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement complete all as specified and directed.
Material and Labour for rendering 15 mm thick cement plaster in cement mortar (1:6) on fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali-resistant primer complete all as specified and as directed.
M&L framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike; framed guard bars and similar work conforming to Fe 290 Ggde E-165 complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and directed.
Taking down cement or cement lime plaster on brick walls or concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for machine cut Kota stone slab 20-25 mm thick, laid over and including 20mm thick screed bed in cement mortar (1:6) using coarse sand as in flooring, set & jointed in neat grey cement slurry and ponted in white cement mixed with pigment to match including grinding and polishing to granite finish complete all as specified and directed.
M&L for machine cut Kota stone slab 20-25 mm thick, laid over and including 10mm thick backing coat in cement mortar (1:4) as in vertical surfaces, set & jointed in neat grey cement slurry and ponted in white cement mixed with pigment to match including grinding and polishing to granite finish complete all as specified and directed.
M&L for providing 25 mm thick cement concrete type B-0 1:2:4 (12.5 mm graded stone aggregate) as in floor complete all as specified and directed.
M & L Preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, mass and efflorescent salts and trading oil and greasy spots and apply one coat of white wash complete all as specified and directed.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 meter openable length (total length 90 m), having 50 nos round per 6 metre length, up to 3 m height of wall with existing angle iron „Y‟ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R. B. T. reinforced barbed wire, stud tied with G. I. staples and G. I. clips to retain horizontal, including necessary bolts or G. I. barbed wire tied to angle iron, with reinforced barbed tape (R.B.T.)/ Spring core (2.5 mm thick) wire of high tensile strength of 165kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately). complete all as specified and directed.
AK Construction Co
Krishana Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .