Executive Engineer
Electrical Division HPPWD Palampur
Construction of Adarsh Gram Sukh Aashrya Parisar Village Luthan Tehsil Jawalmukhi District Kangra HP Sub Head Providing E I in Mahila Sadan100Pax therein
2025_PWD_117605_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹1.5 L
21 Oct 2025
13 Oct 2025
21 Oct 2025
13 Oct 2025
21 Oct 2025
13 Oct 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group - A Make:- Legrand(Myrius), Schiender(Livia), Anchor Roma( plus),L&T (Entice)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable in surface/ recessed PVC conduit heavy duty 2mm thickness, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required
Group - A Make:- Legrand(Myrius), Schiender(Livia), Anchor Roma( plus),L&T (Entice)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required Make: Plaza/L&T/Anchor
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 x 10 sq.mm + 1 x 6 sq.mm. earth wire
2 x 16 sq.mm + 1 x 6 sq.mm. earth wire
4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. Make:- Plaza/L&T/Anchor
3 X 1.5 sq. mm
3 X 2.5 sq. mm
3 X 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make- Legrand(Myrius), Schiender(Livia), Anchor Roma(Plus),L&T
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 5/6 amps,15/16 amps modular switch, connection etc. as required. Make- Legrand(Myrius), Schiender(Livia), Anchor Roma(Plus),L&T
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. Make- Legrand(Myrius), Schiender(Livia), Anchor Roma(Plus),L&T
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make- Legrand, Schiender, Anchor
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Make- Legrand, Schiender, Anchor
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make- Legrand(Myrius), Schiender(Livia), Anchor Roma(Plus),L&T
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing batten/angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.Make- Anchor,SSK,Goldmedal, L&T,Legrand,, Schiender.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing extra down rod of 60 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) . Make:- Jindal Hissar.Tata.
Providing and Fixing of Surface/Recess 600 mm X 600 mm LED fixture 36 W +/- 1W with HET Plastic diffuser with CRCA Powder Coated housing having minimum system lumen efficacy > 100lm/W with P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V , 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.Make:- Wipro,Philips,Panasonic
Providing and fixing industrial LED Batten Light of IP40 Led fixture 40 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with Extruded aluminium housing having minimum system lumen output 1000 lumens and system lumen efficacy of > 100 lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Wipro,Philips,Panasonic
Providing and Fixing of IP20 LED fixture of 18 watt +/- 1 W LED Surface/Recess Mounted Downlighter Round/Square Shape with minimum system lumen efficacy of > 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Wipro,Philips,Panasonic
Supply & Fixing of 12 W LED Wall Light Blub complete in all respect., PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, complete in all respect.Make:- Philips, Wipro, Phanasonic
Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of >100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 .The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Wipro,Philips,Panasonic
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make:- Bajaj, Usha, Anchor
Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: .Make:- Bajaj, Usha, Anchor
300mm EXHAUST FAN
Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). Make:- Legrand, Schiender, L&T
12 way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). Make:- Legrand, Schiender, L&T
8 way Double door
12 way Double door
Supplying and fixing following rating, pole, 240V/415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- Legrand, Schiender, L&T
63 amps DP MCB
63 amps 4P MCB
Supplying and fixing following rating, four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. Make:- Legrand, Schiender, L&T
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Legrand, Schiender, L&T
Single pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Make:- Legrand, Schiender, L&T
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. Make:- Legrand, Schiender, L&T
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.Make:- Legrand, Schiender, L&T
Supply installation testing & commissioning of LT panel Board for the extension of existing panel as per the following specification with proper copper earthing as recommended. The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. The panel should be suitable for seismic zone V. the panel should be approved/tested from the CPRI lab and should be Comfirm I.EC(61439 Part-1&2)(EVAPower system & control or approved make).Make of panel: L&T, ABB , Schneider & Hagger.
LT Outgoing should be IP 54 and should have switchgears as below. Make of LV switchgear : L&T (Lauritz & Knudsen), Schneider , ABB, Siemens & Hagger.
Building Panel Children Female
INCOMER:-
1 No 320 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity
1 No 125 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity
1 No 320 Amp. 4P Contractor
1 No 125 Amp. 4P Contractor
1 No 320 Amp. 4P ATS
2 No. Multi Function Meter.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
1 No. Over Voltage protection Microprocessor based,under voltage protection
BUS BARS:-
400 Amps. TP&N Copper bus bars (25 KA)
OUT GOINGS:-
7 Nos. 63 Amps. FP MCB
10 Nos. 32 Amps. FP MCB
1 Nos. 63 Amps. DP MCB
2 Nos. 32 Amps. DP MCB
2 Nos. Space & Spare
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, & providing masonry enclosure with cover plate having locking arrangement & watering pipe of 2.7 metre long etc. with charcoal/ coke & salt as required.
Supply, Erection, Installation and Commissioning of UniEarth Maintenance free chemical earthing system consisting of environment friendly ground enhancing compound ‘G.E.C’ 50 kg or as required at site having anticorrosive and hygroscopic properties to replace excavated soil. It should consist of “Uniearth” Copper bonded electrodes, as per site conditions and soil resistivity at various depth levels and different terrains. The electrodes should have coating of 250 microns of molecularly bonded pure electrolytic copper (99.9%) in 2 metre length, 17.2 mm diameter, Terminal joint 200x25x6mm GI Strip with exothermic welds. The electrode should be duly tested and certified by CPRI for 30 kA short time current test for 1 sec rms.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, Copper tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing Copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run).
Providing and fixing Copper tape
20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.Makes-ELCON Global,super cable tray Pvt. Ltd.
100 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.Makes-ELCON Global,super cable tray Pvt. Ltd.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.Makes-ELCON Global,super cable tray Pvt. Ltd.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:-
25 Liter capacity water heater (Cat-A)
Makes:-Usha,Crompton
Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
Makes: Anchor/Goldmedal.
Supplying and fixing of following sizes of heavy class FRLS PVC conduit having wall thickness 2.0mm along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required. (For CCTV, Fire Alarm & LAN System) Makes: Diplast/Polyplast.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.59 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
2.pdf
Tender Documents • 5.06 MB
DECLARATION.pdf
Additional Documents • 2.36 MB
BOQ_171999.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .